{"product_id":"3500-42-06-01-3500-42m-bently-nevada-proximitor-seismic-monitor-module","title":"3500\/42-06-01 3500\/42M  | Bently Nevada | Proximitor Seismic Monitor Module","description":"\u003cp\u003eThe \u003cstrong\u003e3500\/42-06-01\u003c\/strong\u003e is a 4-channel Proximitor Seismic Monitor assembly designed for the Bently Nevada 3500 Machinery Protection System. This specific part number configuration pairs the standard 3500\/42M monitor channel board with a specialized I\/O module featuring internal safety barriers and internal terminations for velocity sensors, alongside CSA\/NRTL\/C hazardous location agency approvals. It continuously conditions proximity and seismic transducer inputs to deliver reliable vibration and position tracking.\u003c\/p\u003e\n\u003ch3\u003eChannel Functions and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe module operates across four independent input channels programmed in pairs to execute multiple vibration and position measurements simultaneously. Using the 3500 Rack Configuration Software, channels can be configured for radial vibration, thrust position, differential expansion, eccentricity, or velocity parameters. It evaluates real-time inputs against user-defined Alert and Danger setpoints to ensure prompt machinery protection and alarm triggering.\u003c\/p\u003e\n\u003ch3\u003eI\/O Configuration and Hazardous Approvals\u003c\/h3\u003e\n\u003cp\u003eThe designated -06 rear I\/O module incorporates internal safety barriers tailored for direct connection with approved seismic transducers without requiring external barrier blocks. The -01 suffix designates compliance with CSA, NRTL, and C standards for operation within Class I, Division 2 hazardous environments. Front-panel coaxial connectors provide short-circuit-protected buffered outputs for diagnostic analysis.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/42-06-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500 \/ 3500\/42M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximitor Seismic Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 channels (proximity, velocity, or acceleration transducers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Option (-06)\u003c\/td\u003e\n\u003ctd\u003eInternal barriers and internal terminations (Velomitor \/ seismic compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option (-01)\u003c\/td\u003e\n\u003ctd\u003eCSA \/ NRTL \/ C (Class I, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA proportional to full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C (-22 deg F to +149 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What configuration does the -06 I\/O module option provide?\u003c\/p\u003e\n\u003cp\u003eA: The -06 designation indicates an I\/O module equipped with internal safety barriers and internal signal terminations designed for seismic and velocity transducers.\u003c\/p\u003e\n\u003cp\u003eQ: Can individual channel pairs run different monitoring functions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the four channels are programmed in pairs, allowing channels 1 and 2 to execute one monitoring function while channels 3 and 4 run the same or an independent function.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68019190399285,"sku":"3500\/42-06-01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/350042M128229-01_8d5e4ab1-ab25-4c98-a1a7-5e11d50d8974.jpg?v=1793604475","url":"https:\/\/www.5gplc.com\/products\/3500-42-06-01-3500-42m-bently-nevada-proximitor-seismic-monitor-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}