{"product_id":"330104-01-02-50-02-02-bently-nevada-3300-xl-8-mm-probe","title":"330104-01-02-50-02-02 | Bently Nevada | 3300 XL 8 mm Probe","description":"\u003cp\u003eThe Bently Nevada \u003cstrong\u003e330104-01-02-50-02-02\u003c\/strong\u003e is an 8 mm eddy current proximity probe configured with an M10 x 1 threaded case and protective armor for non-contact vibration and position measurement on rotating equipment. Based on the provided specification record, this configuration includes a 5.0 m (16.4 ft) standard cable, a miniature coaxial ClickLoc connector, and a non-approved agency option, with conflicting length and suffix details documented in the editorial note below.\u003c\/p\u003e\n\u003ch3\u003eOrdering Configuration and Mechanical Features\u003c\/h3\u003e\n\u003cp\u003eThe base prefix \u003cstrong\u003e330104\u003c\/strong\u003e identifies the metric M10 x 1 threaded 3300 XL 8 mm proximity probe with protective armor over the coaxial cable. Adding protective armor shields the cable jacket against mechanical contact and abrasion during installation and routing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable and Connector\u003c\/strong\u003e: Terminates in a miniature coaxial ClickLoc connector (02) on standard coaxial cable with a stated total length of 5.0 m (16.4 ft).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approval\u003c\/strong\u003e: Listed as not required (02 in the source specification text) for applications without hazardous-area certification requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Function\u003c\/strong\u003e: Operates as a passive eddy current probe that detects distance changes to a conductive target surface when paired with a compatible Proximitor sensor and matched system cabling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-01-02-50-02-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1, with armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e100 mm (listed as option 01 in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd\u003e20 mm (listed as option 02 in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd\u003e5.0 m \/ 16.4 ft (listed under 50 in part number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector and Cable Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (option 02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eNot required (listed as option 02 in source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.323 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eU.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330104-01-02-50-02-02 output a direct voltage or 4-20 mA signal to a PLC or DCS?\u003c\/p\u003e\n\u003cp\u003eA: No. As an eddy current proximity probe, it must be connected to a compatible Proximitor sensor and matched system cable length to condition the gap signal into a usable output.\u003c\/p\u003e\n\u003cp\u003eQ: What should buyers verify before ordering the 330104-01-02-50-02-02?\u003c\/p\u003e\n\u003cp\u003eA: Verify the exact unthreaded length, overall case length, and agency approval suffix against the physical nameplate or original Bently Nevada ordering sheet, as the source specification contains conflicting option codes.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68464135799093,"sku":"330104-01-02-50-02-02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/330102-24-48-05-01-RU_f76658ef-4e89-446f-8e8b-021e948f0990.png?v=1795421070","url":"https:\/\/www.5gplc.com\/products\/330104-01-02-50-02-02-bently-nevada-3300-xl-8-mm-probe","provider":"High Five Auto Solution Limited","version":"1.0","type":"link"}