{"product_id":"3300-xl-8-mm-330103-00-09-20-02-00-proximity-probes-bently-nevada","title":"3300 XL 8 mm | 330103-00-09-20-02-00 Proximity Probes | Bently Nevada","description":"\u003cp\u003eThe \u003cstrong\u003e330103-00-09-20-02-00\u003c\/strong\u003e is an 8 mm eddy-current proximity probe from the Bently Nevada 3300 XL series designed for non-contact vibration and relative position measurement in rotating machinery. This model features an M10 x 1 metric thread profile without outer armor, a 0 mm unthreaded length, a 90 mm overall case length, and a 2.0-meter total cable length. It is equipped with a miniature coaxial ClickLoc connector and operates without requiring specialized hazardous-area agency approvals.\u003c\/p\u003e\n\u003ch3\u003eMechanical Configuration and Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe base model 330103 designates the standard unarmored 3300 XL 8 mm proximity probe configuration. The initial -00 option specifies an unthreaded length of 0 mm, while the -09 option establishes a 90 mm overall case length for installation depth. The -20 code defines a total cable length of 2.0 meters (6.6 feet). The -02 option indicates a standard cable terminated with a miniature coaxial ClickLoc connector, and the final -00 code denotes standard agency approval without hazardous-area certification.\u003c\/p\u003e\n\u003ch3\u003eSignal Characteristics and System Integration\u003c\/h3\u003e\n\u003cp\u003eOperating on eddy-current principles, the probe senses the gap distance between its polyphenylene sulfide (PPS) tip and a conductive machine shaft, supporting standard -10 VDC gap voltage calibration. It yields a linear measurement range between 0.25 mm and 2.3 mm with a sensitivity of approximately 7.87 V\/mm (200 mV\/mil). The coaxial construction suppresses cross-talk and maintains stable rotor-dynamic signal transmission through industrial wiring pathways.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain straight routing of the 2.0-meter cable to preserve coaxial impedance.\u003c\/li\u003e\n\u003cli\u003eAlign the probe tip perpendicular to the rotor surface for accurate displacement measurement.\u003c\/li\u003e\n\u003cli\u003eAvoid tight bends near the ClickLoc connector to maintain coaxial geometry.\u003c\/li\u003e\n\u003cli\u003eGround shielding at the driver end only to prevent ground-loop interference.\u003c\/li\u003e\n\u003cli\u003eVerify gap voltage during commissioning to confirm correct mechanical positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-09-20-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 without armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length Option\u003c\/td\u003e\n\u003ctd\u003e0 mm (-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Case Length Option\u003c\/td\u003e\n\u003ctd\u003e90 mm (-09)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Length Option\u003c\/td\u003e\n\u003ctd\u003e2.0 metres (6.6 feet) (-20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector and Cable-Type Option\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector, standard cable (-02)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003eStandard (no hazardous-area certification) (-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 mm case; 2.0 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: Must the probe be paired with a specific extension cable length?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Eddy-current probes require exact cable length matching to maintain correct -10 VDC gap voltage calibration.\u003c\/p\u003e\n\u003cp\u003eQ: Can the probe be installed near high-current conductors?\u003c\/p\u003e\n\u003cp\u003eA: It is not recommended. Electromagnetic fields may distort the sensing field and affect measurement linearity.\u003c\/p\u003e\n\u003cp\u003eQ: Is the probe suitable for high-temperature bearing housings?\u003c\/p\u003e\n\u003cp\u003eA: The operating temperature range of -52 deg C to +177 deg C supports typical fluid-film bearing environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":68193643495733,"sku":"330103-00-09-20-02-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/330103-00-03-10-02-00_2357cff0-38a2-4736-849d-7f036eb95824.jpg?v=1794454834","url":"https:\/\/www.5gplc.com\/products\/3300-xl-8-mm-330103-00-09-20-02-00-proximity-probes-bently-nevada","provider":"High Five Auto Solution Limited","version":"1.0","type":"link"}