{"product_id":"32000-00-00-04-470-01-02-bently-nevada-proximity-probe-housing-assemblies","title":"32000-00-00-04-470-01-02 Bently Nevada Proximity Probe Housing Assemblies","description":"\u003cp\u003eConfigured for radially mounted proximity transducers and Keyphasor signals in Bently Nevada Machinery Monitoring Systems, the \u003cstrong\u003eBently Nevada 32000-00-00-04-470-01-02\u003c\/strong\u003e (\u003cstrong\u003e32000\u003c\/strong\u003e Proximity Probe Housing Assembly) provides direct physical mounting and external gap adjustment capabilities.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Field\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard proximity probe interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandoff Adapter Option\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eNo standoff adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFittings Option\u003c\/td\u003e\n\u003ctd\u003e04\u003c\/td\u003e\n\u003ctd\u003eFlexible conduit and fittings option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Penetration Option\u003c\/td\u003e\n\u003ctd\u003e470\u003c\/td\u003e\n\u003ctd\u003e47.0 in sleeve penetration length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitting Option\u003c\/td\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eSingle 3\/4-14 NPT conduit fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eMultiple hazardous area approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e32000-00-00-04-470-01-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eRadial mounting configuration with 47.0 in sleeve length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C (-62 deg F to +212 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive mechanical housing assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +105 deg C (-62 deg F to +221 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene sulfide (PPS) and stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrientation\u003c\/td\u003e\n\u003ctd\u003eRadial transducer mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eAPI 670 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTransducer Mounting and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 32000-00-00-04-470-01-02 assembly maintains mechanical alignment for proximity probes targeted at high-speed rotating shafts. Its external access design allows real-time gap voltage validation (-10 VDC nominal target) using calibrated digital multimeters without interrupting machine operation or dismantling outer casings. Rigid stainless steel sleeve integration ensures stable eddy-current probe scaling and prevents physical deflection, minimizing cross-talk suppression issues across adjacent X-Y radial channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the probe gap adjusted when using the 32000 housing assembly?\u003c\/p\u003e\n\u003cp\u003eA: Gap adjustments are performed externally by loosening the housing sleeve lock mechanism and threading the internal probe adapter until the desired DC voltage baseline (-10 VDC) is registered across the Proximitor output terminals.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protection standards does this assembly satisfy?\u003c\/p\u003e\n\u003cp\u003eA: Constructed from polyphenylene sulfide (PPS) and stainless steel, the assembly meets API 670 requirements for radial transducer installations in harsh industrial environments and supports intrinsically safe loop designs.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the PPS housing body and 47.0-inch stainless steel sleeve for physical defect before mounting onto the machine boss.\u003c\/li\u003e\n\u003cli\u003eApply anti-seize compound to external mounting threads and engage a minimum of 5 full 3\/4-14 NPT threads into the machine housing.\u003c\/li\u003e\n\u003cli\u003ePass the proximity probe and extension cable through the internal sleeve, ensuring the cable bend radius remains within specified limits.\u003c\/li\u003e\n\u003cli\u003eSet probe insertion depth to achieve the required -10 VDC gap voltage baseline prior to securing the outer compression nut.\u003c\/li\u003e\n\u003cli\u003eGround the conduit run according to site electrical practices and confirm the extension cable shield remains isolated from local machine chassis ground.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53211224506677,"sku":"32000-00-00-04-470-01-02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/32000-00-00-04-420-01-02_1ac007af-e426-4768-aa42-0f78f5498258.png?v=1784865334","url":"https:\/\/www.5gplc.com\/products\/32000-00-00-04-470-01-02-bently-nevada-proximity-probe-housing-assemblies","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}