{"product_id":"30731565-002-honeywell-power-supply-module","title":"30731565-002 | Honeywell | Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 30731565-002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e30731565\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for localized DC bus power conditioning within Honeywell control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30731565-002 (30731565)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.59 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial power chassis form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous 8.5 A AC input load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100-130 VAC (60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 A continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 30731565-002 power supply accepts single-phase AC utility input and delivers regulated 25 VDC at up to 20 A to backplane communication buses and field loop networks. Integrated line filtering suppresses transient voltage spikes and high-frequency electrical noise, providing isolated power rails that protect connected 4-20 mA HART loop protocol transmitters and I\/O interface electronics from grid disturbances. Built-in current limiting and thermal overload protection prevent output rail voltage collapses during momentary downstream field short circuits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 30731565-002 power supply module support parallel redundant wiring configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, multiple power supply units can be tied to a common DC distribution bus using external isolation diodes to provide seamless 1+1 redundant failover without voltage interruption to active controllers.\u003c\/p\u003e\n\u003cp\u003eQ: What protection mechanisms engage if the AC input voltage drops below 100 VAC?\u003c\/p\u003e\n\u003cp\u003eA: An internal brownout detection circuit triggers an under-voltage lockout, turning off the output stage to prevent unregulated voltage levels from reaching connected field modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Security\u003c\/strong\u003e: Secure the module chassis using all primary mounting hardware holes to support the heavy 21.59 kg static weight and minimize vibration transfer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance\u003c\/strong\u003e: Maintain a minimum 100 mm vertical ventilation gap above and below the supply housing to facilitate natural convection cooling and prevent thermal trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePE Wiring\u003c\/strong\u003e: Connect the main protective earth (PE) grounding conductor directly to the heavy-duty grounding terminal lug before energizing AC line power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Conductor Sizing\u003c\/strong\u003e: Size 25 VDC field output cabling according to maximum 20 A continuous current ratings to prevent excessive voltage drop over long wiring runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67654384648501,"sku":"30731565-002","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/30731565-002.png?v=1791438629","url":"https:\/\/www.5gplc.com\/products\/30731565-002-honeywell-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}