{"product_id":"2mlr-e12p-honeywell-masterlogic-200-12-slot-extension-base","title":"2MLR-E12P Honeywell MasterLogic-200 12-Slot Extension Base","description":"\u003cp\u003eConfigured for multi-module expansion and localized I\/O backplane interconnectivity in MasterLogic-200 PLC networks, the \u003cstrong\u003eHoneywell 2MLR-E12P\u003c\/strong\u003e (\u003cstrong\u003e2MLR-E12P\u003c\/strong\u003e Extension Base) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100.068%; height: 235px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003cth style=\"width: 34.8841%; height: 19.5833px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 62.1586%; height: 19.5833px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003e2MLR-E12P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eSouth Korea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eApprox. 0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eApprox. 426 mm x 98 mm x 19 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003e-10 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eBackplane-driven passive chassis load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003e12 I\/O module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eBus Type\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eHigh-speed backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 34.8841%; height: 19.5833px;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd style=\"width: 62.1586%; height: 19.5833px;\"\u003eMasterLogic-200 PLC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe 2MLR-E12P expansion chassis incorporates high-speed backplane communication velocity pathways to maintain deterministic data update rates across all 12 expansion slots. Integrated noise-suppression traces prevent data packet corruption during high-density I\/O switching events. The structural backplane architecture maintains firmware flash compatibility across connected digital, analog, and special-function modules, ensuring full hardware synchronization without latency bottlenecks across the expansion bus interface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can I\/O modules be hot-swapped within the 12 expansion slots of the 2MLR-E12P during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Module removal or insertion requires isolation of the expansion base power source unless the specific system CPU and backplane power configuration explicitly supports live insertion to prevent backplane bus fault trips.\u003c\/p\u003e\n\u003cp\u003eQ: How does the backplane bus maintain signal integrity across all 12 slots?\u003c\/p\u003e\n\u003cp\u003eA: The base utilizes integrated termination impedance matching and multi-layer ground shielding to eliminate signal reflections and cross-talk during high-speed backplane communication.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the 2MLR-E12P extension base horizontally onto a standard DIN rail or directly to the panel enclosure backplate using mounting screws.\u003c\/li\u003e\n\u003cli\u003eVerify that all DIN rail locking levers or chassis mounting hardware are firmly secured to prevent mechanical displacement from vibration.\u003c\/li\u003e\n\u003cli\u003eConnect the expansion link cable from the primary CPU base or preceding expansion base to the dedicated bus interface port on the 2MLR-E12P.\u003c\/li\u003e\n\u003cli\u003eEstablish a direct low-impedance ground connection from the chassis ground terminal to the primary cabinet ground busbar using a short copper strap.\u003c\/li\u003e\n\u003cli\u003eInsert required MasterLogic-200 I\/O modules vertically into designated slots, pushing firmly until the top and bottom retaining clips snap into place before restoring system power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53595112341813,"sku":"2MLR-E12P","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2MLR-E12P_Cocoai.png?v=1789538174","url":"https:\/\/www.5gplc.com\/products\/2mlr-e12p-honeywell-masterlogic-200-12-slot-extension-base","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}