{"product_id":"2711p-rp2a-allen-bradley-panelview-plus-700-1500-ac-logic-module","title":"2711P-RP2A | Allen Bradley | PanelView Plus 700-1500 AC Logic Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2711P-RP2A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the central processing core for PanelView Plus 700, 1000, 1250, and 1500 graphic terminals. This AC-powered logic module manages the execution of FactoryTalk View Machine Edition (ME) runtime applications, coordinating data traffic between the display and the controller. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, original factory stock, ensuring the computational speed and memory integrity required for high-availability industrial monitoring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 2711P-RP2A utilizes a robust internal memory architecture and a wide-range AC power supply to support complex HMI graphics and data logging.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLogic Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePanelView Plus 700 to 1500 Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100–240V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 VA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.3A at 100V \/ 0.65A at 240V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128 MB RAM \/ 128 MB Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSoftware Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFactoryTalk ViewPoint Compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.05 lbs (0.93 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Field Upgradability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2711P-RP2A mounts directly to the back of existing PanelView Plus display modules. This modular design allows engineers to upgrade the processing power or replace a failed logic engine without discarding the functional display screen, significantly reducing maintenance costs and hardware waste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal AC Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal power supply handles a broad voltage range from 100V to 240V AC. This eliminates the need for external DC power supplies or step-down transformers, allowing direct integration into standard plant power grids globally.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eViewPoint Remote Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports FactoryTalk ViewPoint, enabling remote web-based browser access to the HMI screens. This capability allows plant managers and engineers to monitor real-time production data from a remote office or mobile device without installing additional software on the client machine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 128 MB RAM\/Flash configuration ensures rapid screen transitions and responsive alarm handling. The module processes complex graphical objects and historical trends efficiently, preventing the input lag often associated with underpowered legacy hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 2711P-RP2A with the newer PanelView Plus 6 or 7 displays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2711P-RP2A targets the original PanelView Plus series (700-1500). While it physically resembles newer versions, the firmware and hardware architecture specifically match the legacy PanelView Plus displays. Verify your display module's series compatibility before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this logic module support multiple concurrent applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 2711P-RP2A is a \"Single Application\" module. It runs one FactoryTalk View ME project at a time. If your operation requires multiple simultaneous projects or complex Windows-based background tasks, consult the technical data for the \"CE\" expanded versions of the logic modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should I take during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure you disconnect all AC power before seating the logic module onto the display. Tighten the mounting screws to the specified torque to maintain electrical contact and structural rigidity, especially in high-vibration environments like stamping or heavy machining areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I manage the memory limits of the 128 MB Flash?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 128 MB Flash stores the runtime application and local data logs. To maintain optimal performance, regularly clear historical alarm logs and optimize graphical assets within FactoryTalk View Studio to ensure the project remains well within the module's 128 MB capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52788483031349,"sku":"2711P-RP2A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2711P-RP2A.png?v=1777274598","url":"https:\/\/www.5gplc.com\/products\/2711p-rp2a-allen-bradley-panelview-plus-700-1500-ac-logic-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}