{"product_id":"22c-b024n103-allen-bradley-powerflex-400-adjustable-frequency-ac-drive","title":"22C-B024N103 | Allen-Bradley | PowerFlex 400 Adjustable Frequency AC Drive","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e22C-B024N103\u003c\/strong\u003e functions as a high-performance, adjustable frequency AC drive within the PowerFlex 400 manufacturing family. Engineers design this hardware speed controller primarily to regulate variable torque loads, such as heavy-duty industrial fan systems and centrifugal fluid pumps.\u003c\/p\u003e\n\u003cp\u003eThe device dynamically modulates voltage and frequency lines to match motor output with real-time operational demand, slashing facility energy overhead. We distribute this motor controller exclusively as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e, which guarantees intact copper bus bars, virgin IGBT power modules, uncompromised internal capacitor banks, and original factory-certified firmware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below displays the electrical parameters, input-output capacities, and mechanical metrics of the 22C-B024N103 variable frequency drive:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance \u0026amp; Industrial Power Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22C-B024N103\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUPC Barcode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e820919234040\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerFlex 400 Drive Platform\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Frequency AC Drive (VFD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Phase Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3-Phase Phase Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200V AC Minimum to 240V AC Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperational Supply Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Hz to 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.1 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0V to 230V AC (Three-Phase Adjustable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Capacity Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.5 kW (Kilowatts)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Apparent Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.9 kVA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDisplacement Power Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.98 (Highly Efficient Grid Power Draw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Hardware Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.00 lbs (3.63 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTrims Cabinet Footprint via Zero-Stack Side-by-Side Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe mechanical enclosure utilizes an efficient internal thermal cooling path that vents exhaust gases straight out the top of the chassis. This thermal flow allows installers to pack multiple drives adjacent to each other on a single backplate with zero structural space gaps, eliminating precious lateral inches inside tightly packed electrical enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Harmonic Current Disruption with an Efficiency Rating of 0.98:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal input rectifier circuit architecture delivers a robust 0.98 displacement power factor under full motor loads. This clean power draw prevents severe harmonic feedback from travelling backward onto the main plant transformers, protecting adjacent logic boards and sensitive weighing sensors from power-line noise errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplifies HVAC Integration with Embedded Automation Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe microprocessor features native, onboard industrial communication protocols right on the control terminals. This communication interface gives the drive the ability to interlock smoothly into building automation networks without requiring costly external communications cartridges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this drive operate a standard 3-phase AC motor if the local utility grid only supplies 1-phase power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 22C-B024N103 requires a balanced 3-phase input supply voltage between 200V and 240V AC to satisfy its internal phase monitoring hardware and handle the 26.1 Amp nominal input current requirement. Attempting to feed single-phase lines into this specific model triggers an immediate input phase-loss fault condition, locking out the output firing circuit to safeguard internal rectifiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat proper spacing guidelines ensure long-term thermal survival inside unventilated enclosures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the drive supports tight side-by-side positioning with adjacent PowerFlex units, field technicians must preserve minimum vertical clearance spaces to allow proper convection airflow. Maintain at least 4.7 inches (120 mm) of unobstructed space above and below the drive housing, and verify that the ambient temperature of the surrounding air stays under 50 degrees Celsius.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat shielding techniques block high-frequency output EMI from disrupting local analog signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must run a continuous, four-conductor shielded motor cable from the U, V, and W drive terminals straight to the motor terminal box. Ground the cable shield firmly at both the drive enclosure's internal chassis ground ground bar and the motor frame ground lug using heavy brass grounding clamps to safely drain away radio-frequency electrical noise before it interferes with surrounding low-voltage 4-20mA sensor circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52906374725941,"sku":"22C-B024N103","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/22C-D030N103_f776821d-d7c6-4b7d-93ec-f9bc7e52d19e.png?v=1779261590","url":"https:\/\/www.5gplc.com\/products\/22c-b024n103-allen-bradley-powerflex-400-adjustable-frequency-ac-drive","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}