{"product_id":"216db61-hesg324063r100-abb-binary-input-and-tripping-unit","title":"216DB61 HESG324063R100 | ABB | Binary Input and Tripping Unit","description":"\u003cp\u003eConfigured for high-speed fault detection and protective action in Procontrol P13 excitation platforms, the \u003cstrong\u003eABB 216DB61 HESG324063R100\u003c\/strong\u003e (\u003cstrong\u003e216DB61\u003c\/strong\u003e Binary Input and Tripping Unit) provides direct physical\/electrical execution. The module captures field binary signals and drives six high-speed tripping relays with dual contact configurations to perform rapid, redundant fault isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e216DB61 (HESG324063R100)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBinary Input and Tripping Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.5 mm x 75 mm x 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal auxiliary burden dependent on active relay state\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Config\u003c\/td\u003e\n\u003ctd\u003eSix tripping relays with dual contact output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eIntegrated short-circuit protection and redundant power inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Networks and Backplane Bus Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with subrack backplane communication buses, maintaining low latency execution for high-speed tripping logic. Data frames pass via PROFINET and Modbus TCP\/IP industrial networks to central control processors without compromising local relay tripping response times. Integrated firmware flash compatibility guarantees continuous signal processing and rapid fault clearing across synchronized control racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual contact configuration on the tripping relays support fault isolation?\u003c\/p\u003e\n\u003cp\u003eA: The dual contact output arrangement allows parallel or series contact wiring to implement redundant tripping paths or dual-channel feedback validation, minimizing the risk of a single contact failure during critical trip events.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 216DB61 be replaced while the host system remains powered?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping limits depend on rack backplane architecture; field power to input circuits and high-voltage trip outputs must be isolated prior to removing or inserting the unit to prevent unintended tripping or arc flash transients.\u003c\/p\u003e\n\u003cp\u003eQ: What power redundancy features are supported on this module?\u003c\/p\u003e\n\u003cp\u003eA: The module includes dual power input circuitry to accept redundant DC supply feeds, preventing unit shutdown in the event of an auxiliary power supply drop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMounting and Physical Placement: Insert the module into the designated 22.5 mm rack seat or DIN rail socket, ensuring the locking mechanisms fully engage to maintain mechanical connection stability.\u003c\/li\u003e\n\u003cli\u003eSignal Cable Shielding: Terminate binary input and trip loop cable shields to the local earth ground bar using low-impedance ground clamps at the panel entry point to suppress electrical noise.\u003c\/li\u003e\n\u003cli\u003eAuxiliary Power Wiring: Connect primary and secondary DC power feeds to the dedicated redundant power terminals according to polarity markings.\u003c\/li\u003e\n\u003cli\u003eOutput Contact Isolation: Route high-speed tripping output lines separately from low-voltage digital communication cabling to eliminate inductive crosstalk during relay coil actuation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53257007104309,"sku":"216DB61 HESG324063R100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/216DB61HESG324063R100.png?v=1786068947","url":"https:\/\/www.5gplc.com\/products\/216db61-hesg324063r100-abb-binary-input-and-tripping-unit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}