{"product_id":"2094-bm03-s-allen-bradley-kinetix-6000-400v-axis-module","title":"2094-BM03-S | Allen Bradley | Kinetix 6000 400V Axis Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 2094-BM03-S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core Axis Module (AM) for the Kinetix® 6000 multi-axis servo drive system. This 400V-class module provides high-performance motor control by converting DC bus power into precise AC waveforms for rotary and linear servo motors. It operates as part of a modular rail system, drawing power from an Integrated Axis Module (IAM) to drive independent motion axes. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, featuring the integrated \"S\" safety designation to ensure your machine meets modern functional safety requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BM03-S delivers high power density with industry-leading efficiency:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Class\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400V Class\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e650V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current (RMS)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.2 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current (Sine 0-Peak)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePeak Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e53.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Power Output (Nominal)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.5 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e98%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVelocity Loop Bandwidth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Loop Bandwidth\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1300 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Shunt Resistor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafe Torque Off (STO)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncluded\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12.94 lbs (5.87 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2094-BM03-S includes the Safe Torque Off (STO) feature. This hardware-based safety circuit prevents the drive from generating torque to the motor during emergency stops or gate entries, eliminating the need for bulky external power contactors and reducing wear on mechanical components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Performance Loop Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 1300 Hz current loop and 500 Hz velocity loop bandwidth, this module tracks motion profiles with extreme accuracy. This rapid response time minimizes following errors in high-speed applications like delta robotics, labeling, and vertical form-fill-seal (VFFS) machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExceptional Energy Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 98% efficiency rating minimizes heat dissipation within the control cabinet. This reduced thermal footprint allows for tighter module spacing on the Kinetix 6000 rail and lowers the overall cooling requirements for the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Regenerative Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal 115 Ohm shunt resistor manages regenerative energy during rapid motor deceleration. With a peak shunt power capability of 22.5 kW, the module protects the DC bus from overvoltage faults, ensuring stable operation during aggressive indexing cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Multi-Axis Modularly:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module mounts directly onto the 2094 power rail. This design eliminates complex internal wiring between the converter and inverter, simplifying cabinet assembly and allowing for rapid axis replacement or system expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 2094-BM03-S require a separate converter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. As an Axis Module (AM), it requires a Kinetix 6000 Integrated Axis Module (IAM) to provide the 650V DC bus power. It cannot operate as a standalone drive connected directly to AC mains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit a brand new Allen Bradley original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We guarantee that every 2094-BM03-S unit we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand arrives in its original factory packaging. Each module satisfies E-E-A-T industrial procurement standards for authenticity and quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"S\" in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S\" stands for \"Safe Torque Off.\" This specific version includes the safety header required to integrate the drive into a Category 3 or Category 4 safety circuit (ISO 13849-1), providing a certified path to disable motor torque.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to replace a 2094-BM03 (without the -S)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the power specifications are identical, the 2094-BM03-S requires a safety connection to enable the drive. If your existing system does not use safety circuits, you must jump the safety header or update your wiring to accommodate the STO feature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562771968309,"sku":"2094-BM03-S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2094-BM03-S.jpg?v=1776066537","url":"https:\/\/www.5gplc.com\/products\/2094-bm03-s-allen-bradley-kinetix-6000-400v-axis-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}