{"product_id":"2094-bc04-m03-m-allen-bradley-kinetix-6200-integrated-axis-module","title":"2094-BC04-M03-M | Allen Bradley | Kinetix 6200 Integrated Axis Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley \u003cstrong\u003e2094-BC04-M03-M\u003c\/strong\u003e operates as a foundational Integrated Axis Module (IAM) for the Kinetix 6200 multi-axis servo drive platform. This heavy-duty 460V-class module consolidates both the rectifier stage and an inverter axis into a single physical unit. It rectifies incoming three-phase AC factory line power to provide a high-capacity 27.6 kW DC bus link that powers adjacent slotted follower axes across a shared power rail system.\u003c\/p\u003e\n\u003cp\u003eWe supply this component strictly as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto eliminate the mechanical and thermal fatigue vectors common in secondhand components, ensuring predictable performance on critical motion lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe electrical, protection, and installation requirements of the power module include the following parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering Rating \/ Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number \/ UPC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2094-BC04-M03-M \/ 884951147799\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKinetix 6200 Servo System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Module Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Axis Module (IAM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Input Grid Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e324…528V RMS, Three-Phase (360…480V Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Voltage Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e95…264V RMS, Single-Phase (110…240V Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Power Output to Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e27.6 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Output Current to Bus\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e41.5 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAxis Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 A (13 kW Wattage Rating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Overvoltage Trip Threshold\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e825 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBus Undervoltage Trip Threshold\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e275 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Bus Capacitance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8955 µF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation Window\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e94 - 255 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Envelope\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 50°C (32°F to 122°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.00 lbs (9.98 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStabilizes DC Rails Against Voltage Sags:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal 8955 µF capacitor bank absorbs massive load spikes during heavy multi-axis acceleration. This high capacitance prevents the DC bus voltage from dipping into the 275 VDC undervoltage fault zone, allowing continuous machine operation even on unstable regional grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlines High-Power Thermal Extraction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite an output of 27.6 kW to the shared bus, efficient power semiconductors restrict module heat loss to a maximum of 255 Watts. By enforcing a strict 50.8 mm (2.0 in.) vertical clearance zone during panel assembly, natural and forced cabinet airflow paths swiftly clear thermal energy away from sensitive control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Custom Power Backplane Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module drops into enclosures requiring a minimum depth of 272 mm (10.7 in.). It distribution rails plug directly into neighboring axes without long, shielded inter-axis cabling runs, eliminating electromagnetic interference (EMI) coupling and loop-noise issues that typically plague standalone drive architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat specific branch circuit overcurrent devices must engineers use to protect the control voltage inputs of the 2094-BC04-M03-M?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo comply with factory safety ratings, technicians must install Bussmann style FNQ-R-10 (10 A) or FNQ-R-7.5 (7.5 A) fuses on the control input power path. Alternatively, Allen Bradley 1492-SPM2D060 or 1492-SPM1D150 circuit breakers meet the upstream short-circuit protection requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the drive protect its internal inverter circuit if a field motor short-circuits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe drive firmware monitors current draw continuously at the output terminals. If the phase current spikes past safe limits, the module activates its internal overcurrent trip routine and isolates the output gate drivers within microseconds, shielding the central 13 kW power stage from destructive thermal surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module function without a standalone control card installed on its front face?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 2094-BC04-M03-M constitutes the raw power structure of the drive. The unit requires a front-mount Kinetix 6200 control module (such as an EtherNet\/IP control module) to execute control loops, manage safety functions, and process network communications. Always slide the control module firmly into place and engage the locking tabs before applying AC line voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52902569279797,"sku":"2094-BC04-M03-M","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/2094-BC04-M03-M.png?v=1779242320","url":"https:\/\/www.5gplc.com\/products\/2094-bc04-m03-m-allen-bradley-kinetix-6200-integrated-axis-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}