{"product_id":"20-750-s1-allen-bradley-powerflex-750-series-safe-speed-monitor-option-module","title":"20-750-S1 | Allen Bradley | PowerFlex 750 Series Safe Speed Monitor Option Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen Bradley \u003cstrong\u003e20-750-S1\u003c\/strong\u003e functions as a Safe Speed Monitor Option Module specifically engineered for the PowerFlex 750-series and PowerFlex 755 AC drives. This hardware-based safety solution integrates directly into the drive's control pod to provide advanced safety functional capabilities. It monitors motor feedback to enforce programmed safe speed limits or speed locks, allowing operators to perform specific maintenance or manual tasks without removing power from the entire system. By implementing this module, engineers satisfy rigorous global safety standards, including SIL 3 and PLe requirements, within a compact drive footprint.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetailed Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20-750-S1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowerFlex 750 \/ 755\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Speed Monitoring \/ Speed Lock Enforcement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 °C to 50 °C (14 °F to 122 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 °C to 85 °C (-40 °F to 185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% RH, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Altitude\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000 m (6561 ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCoating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOEM Industrial Grade Coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Safety Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 20-750-S1 mounts directly inside the drive control pod. This internal installation eliminates the need for external safety relays or bulky third-party monitoring hardware, significantly reducing control cabinet space requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Machine Productivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports \"Safe Speed\" modes, allowing the machine to run at a reduced, monitored velocity during setup or troubleshooting. This prevents total system downtime while maintaining strict operator protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Feedback Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes safety-rated electronics and high-quality PCB housing to process motor feedback signals accurately. Its OEM industrial coating protects internal components from corrosive industrial atmospheres and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Altitude Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eValidated for operation up to 2000 meters, this module maintains safety integrity and cooling efficiency in diverse geographical locations without derating concerns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Drive Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned exclusively for the PowerFlex 750 and 755 series, the module communicates natively with the drive's internal logic, ensuring rapid response times for safety-trip events and reducing integration complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this 20-750-S1 module supplied as Brand New?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We provide this unit as 100% Brand New in its original factory packaging. Each module includes the necessary safety-rated components and OEM industrial coating required for mission-critical safety applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between Safe Torque Off (STO) and the 20-750-S1 functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard STO only removes power to the motor. The 20-750-S1 \"Safe Speed Monitor\" actively tracks motor velocity through feedback, allowing the drive to maintain torque and control while ensuring the speed never exceeds a pre-defined safety threshold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhere exactly do I install this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module installs into a dedicated slot within the PowerFlex 750\/755 drive control pod or a designated safety enclosure. Always follow the specific torque and mounting instructions provided in the Allen Bradley installation manual to ensure safety compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require special software for configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure the 20-750-S1 through the Studio 5000 Logix Designer environment or via the drive's Human Interface Module (HIM). Proper safety signature validation is required to finalize the safety configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52869682200885,"sku":"20-750-S1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/20-750-S1.png?v=1778637059","url":"https:\/\/www.5gplc.com\/products\/20-750-s1-allen-bradley-powerflex-750-series-safe-speed-monitor-option-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}