{"product_id":"1p00028g01-emerson-remote-node-transition-panel","title":"1P00028G01 | Emerson | Remote Node Transition Panel","description":"\u003cp\u003eConfigured for remote node signal management in Ovation DCS platforms, the \u003cstrong\u003eEmerson 1P00028G01\u003c\/strong\u003e (\u003cstrong\u003e1P00028G01\u003c\/strong\u003e Remote Node Transition Panel) provides direct physical execution of analog and digital signal interfacing. This hardware component functions as a signal transition interface to facilitate connectivity between field-side wiring and the internal Ovation system backplane architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1P00028G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e45 g (1.6 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.1 cm × 2.5 cm × 7.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit or 16-bit configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe transition panel maintains signal fidelity through high-resolution data conversion capabilities, supporting both 12-bit and 16-bit logic profiles. By consolidating multi-point I\/O terminations within the Ovation rack assembly, the module minimizes signal attenuation and potential ground loops that can compromise loop accuracy. The design ensures consistent voltage regulation for sensitive analog inputs while providing a deterministic path for digital state monitoring across the DCS network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1P00028G01 require specific backplane slot positioning within the Ovation rack?\u003c\/p\u003e\n\u003cp\u003eA: The panel must be mounted within a compatible Ovation chassis slot. Ensure that the backplane connector alignment is verified prior to seating to avoid pin deformation or intermittent connection to the system bus.\u003c\/p\u003e\n\u003cp\u003eQ: Is the resolution setting hardware-selectable on the module faceplate?\u003c\/p\u003e\n\u003cp\u003eA: Resolution (12-bit or 16-bit) is determined by the system configuration parameters defined in the Ovation controller software. The hardware supports both modes, but performance is dependent on the downstream input\/output card requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the transition panel into the designated rack or chassis space. Verify that the locking hardware is tightened to ensure mechanical stability during high-vibration operational cycles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Bond the panel chassis to the cabinet ground reference. Proper grounding is necessary to maintain signal integrity and to shield against electromagnetic interference from adjacent high-current cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Use shielded twisted-pair cabling for all analog signals to minimize noise pickup. Ensure cable shields are terminated at the designated grounding points and not at the signal terminals themselves to avoid ground loop current paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification\u003c\/strong\u003e: Check for correct 24 VDC power supply polarity before energizing the module. Monitor terminal strip contacts for signs of oxidation or looseness after initial installation and following the first thermal cycle.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52934242107701,"sku":"1P00028G01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1P00028G01_437c9588-d6b3-4870-8fdc-8deff425a022.png?v=1779957697","url":"https:\/\/www.5gplc.com\/products\/1p00028g01-emerson-remote-node-transition-panel","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}