{"product_id":"1c31116g03-emerson-analog-input-module","title":"1C31116G03 | Emerson | Analog Input Module","description":"\u003cp\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eConfigured for high-density process signal acquisition in Ovation control platforms, the \u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eEmerson 1C31116G03\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e (\u003c\/span\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e1C31116G03\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e) provides direct physical execution of 0-20 mA analog input monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31116G03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 1C31116G03 module is engineered to interface with standard current-loop instrumentation. While the module is specified for a 0-20 mA range, it maintains inherent compatibility with 4-20 mA HART loop protocol signaling, allowing for the acquisition of primary process variables. The module design incorporates channel-to-channel isolation to prevent ground loops and common-mode signal interference, which is necessary for maintaining measurement accuracy in high-density I\/O racks. This isolation barrier protects the controller backplane from field-side voltage transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1C31116G03 module support hot-swap installation?\u003c\/p\u003e\n\u003cp\u003eA: The module supports hot-swapping within the Ovation I\/O chassis. Operators must inhibit the associated input points in the control logic prior to module extraction to prevent diagnostic error flags or erroneous process data entries.\u003c\/p\u003e\n\u003cp\u003eQ: Is field configuration of the input range required?\u003c\/p\u003e\n\u003cp\u003eA: The 1C31116G03 signal scaling is configured via the Ovation engineering workstation. There are no physical hardware jumpers on the module for manual range adjustment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the I\/O chassis slot is clear of debris and the backplane connectors are intact.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the cabinet guide rails and insert until the connector interface is fully seated.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the provided locking levers to maintain electrical contact and structural stability.\u003c\/li\u003e\n\u003cli\u003eTerminate signal conductors to the appropriate terminal block; ensure shielded twisted-pair cables are used and bonded to a single cabinet ground point.\u003c\/li\u003e\n\u003cli\u003eVerify signal validity and input status within the Ovation diagnostic database after system power-up.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52953041404213,"sku":"1C31116G03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1C31116G03.png?v=1780395705","url":"https:\/\/www.5gplc.com\/products\/1c31116g03-emerson-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}