{"product_id":"1c31113g05-emerson-analog-input-module","title":"1C31113G05 | Emerson | Analog Input Module","description":"\u003cp\u003eConfigured for high-precision process signal acquisition in Ovation platforms, the \u003cstrong\u003eEmerson 1C31113G05\u003c\/strong\u003e (\u003cstrong\u003e1C31113G05\u003c\/strong\u003e) provides direct physical execution of analog input monitoring within the control network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31113G05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ Westinghouse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer-defined\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSystem-standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe 1C31113G05 module is designed to interface directly with industrial transmitters via 4-20 mA HART loop protocol signaling. This implementation allows the Ovation controller to acquire primary process variables while simultaneously accessing secondary device diagnostics and configuration data without interrupting the control loop. The module architecture incorporates channel-to-channel isolation, preventing signal degradation due to common-mode noise or ground potential differences in the field wiring. The conversion circuitry supports accurate signal scaling for integration into Ovation DCS control algorithms, maintaining transparency across the instrumentation and control layers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 1C31113G05 module hot-swappable in an active I\/O rack?\u003c\/p\u003e\n\u003cp\u003eA: The module supports hot-swap installation. Before extraction, users must ensure the affected input points are inhibited in the control logic to prevent process disturbances or the generation of unexpected fault alarms.\u003c\/p\u003e\n\u003cp\u003eQ: Does this module require manual configuration via physical switches?\u003c\/p\u003e\n\u003cp\u003eA: No, the 1C31113G05 is software-configurable. All channel parameters and scaling settings are managed through the Ovation engineering workstation, ensuring consistent configuration across system nodes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the I\/O rack slot is prepared and the backplane connectors are clear of debris.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the chassis guide rails and apply steady force until the module is fully seated and locked into the backplane.\u003c\/li\u003e\n\u003cli\u003eTerminate signal conductors to the designated terminal block, ensuring shielded twisted-pair cables are utilized.\u003c\/li\u003e\n\u003cli\u003eVerify that the cable shield is bonded to the cabinet ground at a single common point to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003ePost-installation, perform a diagnostic check using the Ovation HMI to verify signal stability and communication status.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52953000739125,"sku":"1C31113G05","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1C31113G05.png?v=1780393636","url":"https:\/\/www.5gplc.com\/products\/1c31113g05-emerson-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}