{"product_id":"1791ds-ib16-allen-bradley-compactblock-guard-i-o-safety-input-module","title":"1791DS-IB16 | Allen Bradley | CompactBlock Guard I\/O Safety Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1791DS-IB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity safety input module within the CompactBlock™ Guard I\/O™ family. This module interfaces directly with DeviceNet™ Safety networks, providing 16 dedicated safety inputs for monitoring critical field devices such as E-stop buttons, light curtains, and safety gates. It distributes safety-rated digital input data to GuardLogix® or SmartGuard™ controllers. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring your safety circuits comply with the highest SIL and Cat. performance ratings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1791DS-IB16 utilizes a specialized hardware architecture to execute safety-critical logic:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Safety Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-Channel (Configurable for Dual-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDeviceNet Safety\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4–26.4V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 mA @ 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11V DC Minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V DC Maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 (Input Only Module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 lbs (0.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e612598336050\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 3 \/ PLe Rated Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1791DS-IB16 supports safety applications up to SIL 3 (IEC 61508) and PLe (ISO 13849-1). This allows for integration into high-risk machinery zones where functional safety is a mechanical and legal requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Safety Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes the CIP Safety™ protocol over DeviceNet. This enables the transmission of safety and standard control data over a single wire pair, significantly reducing wiring complexity and material costs in distributed safety architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-Board Pulse Testing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module generates test pulses to detect short circuits to external power sources or adjacent channels. This self-diagnostic capability ensures the system identifies wiring faults before they compromise the safety function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Block Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe space-saving design fits into shallow control cabinets. The integrated terminal blocks allow for direct field-device termination, eliminating the need for interposing terminal strips and simplifying the troubleshooting process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Input Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers configure the 16 inputs as individual single-channel points or as 8 dual-channel pairs for applications requiring redundant safety monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1791DS-IB16 require a safety controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This module acts as a remote safety I\/O device. It must communicate with a safety master, such as an Allen Bradley GuardLogix controller or a SmartGuard 600 controller, via a DeviceNet Safety network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product a brand new Allen Bradley original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We guarantee that every 1791DS-IB16 unit we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein original factory-sealed packaging. Each module meets the strict E-E-A-T industrial procurement standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 11V DC On-State voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 11V DC threshold defines the minimum voltage the module recognizes as a \"High\" signal. This specific tolerance ensures stable operation in environments with potential voltage sags, preventing nuisance safety trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor dual-channel light curtains with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can pair the inputs in the software configuration to support dual-channel safety devices. This configuration allows the module to perform cross-channel monitoring to detect discrepancies between the two signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562768658741,"sku":"1791DS-IB16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1791DS-IB16.jpg?v=1776065869","url":"https:\/\/www.5gplc.com\/products\/1791ds-ib16-allen-bradley-compactblock-guard-i-o-safety-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}