{"product_id":"1788-en2dnr-allen-bradley-1788-linking-device-ethernet-ip-to-devicenet-gateway","title":"1788-EN2DNR | Allen-Bradley 1788 Linking Device EtherNet\/IP to DeviceNet Gateway","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1788-EN2DNR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Allen-Bradley connects EtherNet\/IP networks directly to DeviceNet segments in industrial control systems. This linking device enables PLCs and controllers to access, monitor, and control up to 63 DeviceNet slave devices through standard Ethernet infrastructure.\u003c\/p\u003e\n\u003cp\u003eThis unit ships as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New original hardware\u003c\/strong\u003e, ensuring full lifecycle reliability and compatibility with modern automation architectures. The integrated web server allows engineers to configure diagnostics, monitor network status, and manage DeviceNet nodes without additional software tools.\u003c\/p\u003e\n\u003cp\u003eThe dual Ethernet ports support flexible network topologies such as linear and ring configurations, while deterministic communication maintains real-time data exchange between control layers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP to DeviceNet Linking Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1788 Linking Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1788-EN2DNR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 × RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet Ports\u003c\/td\u003e\n\u003ctd\u003e1 × Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax DeviceNet Nodes\u003c\/td\u003e\n\u003ctd\u003e63 Slaves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet Power\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connections\u003c\/td\u003e\n\u003ctd\u003e32 Class 0, 21 Class 1, 16 Class 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 lbs (0.26 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Wiring\u003c\/td\u003e\n\u003ctd\u003e0.25–2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDeviceNet Wiring\u003c\/td\u003e\n\u003ctd\u003e0.52 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Web Server\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1788-EN2DNR solves a common integration challenge: connecting legacy DeviceNet field devices to modern EtherNet\/IP control systems without replacing installed infrastructure.\u003c\/p\u003e\n\u003cp\u003eEngineers install the module directly on a DIN rail inside standard control cabinets. The compact open-type enclosure fits easily into space-constrained panels. Dual Ethernet ports allow daisy-chain wiring, reducing switch requirements and simplifying panel layout.\u003c\/p\u003e\n\u003cp\u003eThe device maintains stable communication under industrial electrical noise. It isolates DeviceNet and Ethernet segments, minimizing interference and improving signal integrity in high-EMI environments such as motor control centers and process plants.\u003c\/p\u003e\n\u003cp\u003eThe built-in web server accelerates commissioning. Engineers access diagnostics through a browser, identify node faults, and adjust parameters without dedicated configuration software. This reduces downtime during startup and maintenance.\u003c\/p\u003e\n\u003cp\u003eThe module supports multiple CIP connection classes, enabling real-time I\/O control, monitoring, and explicit messaging simultaneously. This flexibility supports both high-speed automation tasks and supervisory data exchange.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module replace older DeviceNet scanners?\u003c\/strong\u003e\u003cbr\u003eYes. The 1788-EN2DNR replaces traditional DeviceNet scanner modules by providing Ethernet-based control access while maintaining compatibility with existing DeviceNet devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many devices can I connect on the DeviceNet side?\u003c\/strong\u003e\u003cbr\u003eYou can connect up to 63 DeviceNet slave devices, depending on network power and topology constraints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the device require special configuration software?\u003c\/strong\u003e\u003cbr\u003eNo. The integrated web server allows direct configuration, diagnostics, and monitoring through a standard web browser.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What should I consider during installation?\u003c\/strong\u003e\u003cbr\u003eEnsure stable 24 V DC power supply, proper grounding, and correct DeviceNet termination. Maintain cable separation from high-power lines to reduce electromagnetic interference.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52768907788597,"sku":"1788-EN2DNR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1788-EN2DNR.jpg?v=1776752651","url":"https:\/\/www.5gplc.com\/products\/1788-en2dnr-allen-bradley-1788-linking-device-ethernet-ip-to-devicenet-gateway","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}