{"product_id":"1762-l40awa-allen-bradley-micrologix-1200-programmable-logic-controller","title":"1762-L40AWA | Allen-Bradley | MicroLogix 1200 Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, self-contained controller within the MicroLogix 1200 family. It provides 40 built-in I\/O points, making it a cornerstone for medium-scale industrial automation tasks where panel space remains a premium. This unit manages complex machine logic by utilizing 24 digital inputs and 16 robust relay outputs. We offer this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and factory-original\u003c\/strong\u003e, ensuring your control architecture benefits from the full lifespan of genuine hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1762-L40AWA optimizes performance through the following electrical and physical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Digital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Relay Contact Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V AC (Operating range 47-63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 mA at 5V DC \/ 500 mA at 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Off-State Leakage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.791 Nm (7.0 lb-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs (0.91 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density I\/O Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1762-L40AWA packs 40 I\/O points into a compact chassis. This configuration reduces the need for additional expansion modules, effectively lowering hardware costs and decreasing the overall footprint in crowded control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Power Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal power supply accommodates both 120V and 240V AC nominal inputs. This flexibility allows global deployment of machinery without requiring separate transformers or different regional SKU management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power for Peripherals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller provides dedicated 5V and 24V DC outputs. These power rails support expansion I\/O modules and external sensors directly from the PLC, simplifying field wiring and reducing the component count.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 relay contact outputs handle a mix of AC and DC loads. This feature allows the 1762-L40AWA to control various field devices such as solenoids, motor starters, and pilot lights without the need for interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1762-L40AWA require a separate battery for memory backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MicroLogix 1200 uses flash memory for program storage. While the unit maintains the program without power, we recommend using the optional 1747-BA battery if your application requires long-term retention of volatile data values during extended power-down periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I expand the I\/O beyond the 40 built-in points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can expand the controller’s capability by adding 1762 series expansion I\/O modules to the right side of the base unit. The 1762-L40AWA supports up to six expansion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the correct way to handle high inrush current during startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit draws up to 40 Amps of inrush current at 240V AC. Ensure your upstream circuit breakers and power distribution components account for this short-duration spike (4-8 ms) to prevent nuisance tripping during system initialization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre these units refurbished or new-old-stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee every 1762-L40AWA unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. These are original Allen-Bradley products in their factory packaging, ensuring the relay contacts and internal capacitors have zero prior operational wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52846708982069,"sku":"1762-L40AWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L40AWA.png?v=1778205702","url":"https:\/\/www.5gplc.com\/products\/1762-l40awa-allen-bradley-micrologix-1200-programmable-logic-controller","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}