{"product_id":"1756-l73-controllogix-5573-allen-bradley-controller-module","title":"1756-L73 ControlLogix 5573 | Allen Bradley| Controller Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1756-L73\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance central processing unit within the ControlLogix 5570 family. This Logix5573 controller manages complex discrete, motion, and process applications with high-speed execution and expanded memory capacity. We offer this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Factory Original\u003c\/strong\u003e, ensuring your automation architecture benefits from the latest silicon revisions and full hardware longevity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1756-L73 provides significant computational overhead for data-intensive industrial environments:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlLogix 5573\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Memory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.98 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB 2.0 (Programming and Configuration)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eController Connections\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 Max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLocal I\/O Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e128,000 Digital \/ 4,000 Analog\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw (1.2 VDC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw (5.1 VDC)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e800 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVisual Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-Character Alpha\/Numeric Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.53 lbs (0.24 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Internal Batteries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1756-L73 utilizes energy storage modules (ESM) to power non-volatile memory during shutdowns. This removes the need for scheduled battery replacements and eliminates the risk of memory loss due to sudden battery failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Logix5573 architecture significantly reduces scan times compared to previous generations. It handles high-axis count motion control and complex PID loops simultaneously without degrading system responsiveness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Programming Access:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated USB 2.0 port provides a high-speed interface for logic downloads and online monitoring. This local port simplifies commissioning by allowing engineers to bypass complex network configurations for direct hardware access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced On-Module Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 4-character scrolling display provides real-time status codes and error messages. This allows maintenance teams to identify fault conditions or firmware mismatches immediately without connecting a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this 1756-L73 unit brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Every unit we supply is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the original manufacturer’s box. We do not provide refurbished or used surplus modules, guaranteeing the full integrity of the internal non-volatile memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this controller require a separate battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1756-L73 uses a Capacitor-based Energy Storage Module (ESM). This module charges while the rack has power and provides enough energy to write the project to internal flash memory during a power loss event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1756-L73 in a redundant chassis configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This controller supports high-availability redundancy. When paired with a 1756-RM2 Redundancy Module and an identical 1756-L73 in a secondary chassis, it provides seamless switchover capabilities for critical processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software version do I need for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1756-L73 requires Studio 5000 Logix Designer (or RSLogix 5000 version 20 and later). Always ensure your software version supports the firmware revision installed on the hardware for full feature compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52862512431413,"sku":"1756-L73","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1756-L73K__1_7494083a-5e02-40d9-b31d-a97839a6b6fb.jpg?v=1778466999","url":"https:\/\/www.5gplc.com\/products\/1756-l73-controllogix-5573-allen-bradley-controller-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}