{"product_id":"1734-ow2-allen-bradley-point-i-o-2-point-relay-output-module","title":"1734-OW2 | Allen-Bradley | POINT I\/O 2-Point Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OW2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, electromechanical relay output solution within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O 1734\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. This module integrates two independent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eForm A (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelays, allowing the control of various AC and DC loads in a distributed I\/O architecture. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock. It bridges the gap between low-level PLC logic and high-power field devices like motor starters, solenoid valves, and indicators while minimizing panel space.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Normally Open (Form A) Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A per channel (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 W (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥ 100,000 operations @ rated load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 operation per 3 seconds (0.3 Hz max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–14 AWG (0.25–2.5 mm²) Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Mixed Loads:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-OW2 handles both AC and DC voltages up to 240V AC or 125V DC. This flexibility eliminates the need for separate interposing relays when controlling diverse field equipment, significantly reducing system complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"POINT\" architecture allows users to add precisely two relay points per module. This prevents the \"over-provisioning\" of I\/O commonly seen with 8 or 16-point cards, lowering the overall cost-per-point in small-scale automation skids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250V continuous isolation protects the sensitive backplane electronics from field-side voltage spikes and electrical noise. This barrier ensures that a catastrophic failure on the load side does not propagate to the PLC processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Maintenance Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a \"T-Base\" terminal system (sold separately), which allows for \"Removal and Insertion Under Power\" (RIUP). Maintenance teams can swap a 1734-OW2 module without disturbing the field wiring or shutting down the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Cold Start Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard commercial electronics, the 1734-OW2 operates down to -20°C. This makes it suitable for unheated enclosures in outdoor applications or cold storage facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1734-OW2 for high-speed switching applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The electromechanical design limits the switching frequency to 0.3 Hz (one operation every three seconds) at rated load. For high-speed PWM or rapid cycling, utilize a solid-state output module like the 1734-OB8.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must install the 1734-OW2 on a 1734-TB or 1734-TBS terminal base. The base provides the mechanical connection to the DIN rail and the electrical interface to the POINTBus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the contact health?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes a status LED for each output. If the LED illuminates but the field device does not activate, check the external fuse or the continuity of the electromechanical contact using a multimeter during a maintenance cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a factory-sealed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We ship only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Allen-Bradley boxes with intact serial numbers and factory documentation to ensure E-E-A-T compliance for industrial procurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52531796869429,"sku":"1734-OW2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OW2.jpg?v=1775198063","url":"https:\/\/www.5gplc.com\/products\/1734-ow2-allen-bradley-point-i-o-2-point-relay-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}