{"product_id":"1734-oe2v-allen-bradley-point-i-o-2-channel-0-10v-analog-output-module","title":"1734-OE2V | Allen-Bradley POINT I\/O | 2-Channel 0-10V Analog Output Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog output module designed for the Allen-Bradley POINT I\/O platform. This module provides two single-ended, non-isolated voltage outputs, typically used to drive Variable Frequency Drives (VFDs), pressure regulators, or proportional valves that require a standard 0–10V DC control signal. With its 14-bit resolution and rapid conversion rate, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers smooth, granular control for process loops where high-speed response and signal accuracy are critical. Its ultra-compact 12mm width makes it an ideal choice for distributed I\/O racks with limited space.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a high-speed digital-to-analog converter to translate PLC data into precise physical voltage levels.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Channels (Single-ended, Non-isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10 Volts DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e14-Bit (Unipolar)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital-to-Analog (D\/A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 microseconds per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStep Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 milliseconds to 99% of final value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 milliamps maximum per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal DC Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal (10–28.8V DC range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0 Watt maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.4 BTU\/hour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Format:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSigned Integer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.13 lbs (0.06 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSignal Integrity and Wiring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBecause the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures non-isolated, single-ended outputs, both channels share a common return path. To maintain the 14-bit signal integrity and prevent electrical noise from affecting the output, it is essential to use shielded twisted-pair cabling (such as Belden 8761). The shield should be grounded at only one end, typically at the POINT I\/O chassis ground, to avoid ground loops that could introduce offsets into the 0–10V signal.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation and Hardware Requirements\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a \"plug-in\" module that must be seated into a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emounting base. It requires a Removable Terminal Block (RTB), specifically the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-RTB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-RTBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(spring), to interface with field wiring. Before installation, the mechanical keying on the mounting base must be set to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePosition 4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure the module is correctly aligned and protected from mismatched voltage levels in the rack.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1734-OE2V be used for -10V to +10V bipolar signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific module is designed for unipolar 0–10V DC operation. For bipolar voltage applications, the 1734-OE2C or a specialized bipolar module would be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle the \"Signed Integer\" data format in my logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Studio 5000, the 0–10V output is typically represented by a value range of 0 to 10,000 (or 0 to 16,383 depending on scaling). Using \"Signed Integer\" allows the controller to handle the data with standard math instructions before sending the final value to the module's output register.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the 24V DC field power is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 24V DC field-side power (provided via the power bus in the mounting base) to generate the 0–10V signal. If field power is lost, the \"NODE\" or \"POINT\" status LED will typically flash red, and the outputs will drop to 0V.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457701966133,"sku":"1734-OE2V","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OE2V.jpg?v=1773987753","url":"https:\/\/www.5gplc.com\/products\/1734-oe2v-allen-bradley-point-i-o-2-channel-0-10v-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}