{"product_id":"1734-4iol-allen-bradley-point-i-o-4-channel-io-link-master-module","title":"1734-4IOL | Allen Bradley POINT I\/O 4-Channel IO-Link Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-4IOL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance IO-Link master module within the POINT I\/O family. This module bridges the gap between the controller and smart field devices, providing four dedicated channels for bidirectional communication. It enables users to harness advanced diagnostics and parameterization at the sensor\/actuator level. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring seamless integration into your EtherNet\/IP or DeviceNet distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-4IOL provides digitized field data and robust power distribution for smart factory applications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O (1734)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIO-Link Master\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIO-Link (Point-to-Point)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Handling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCyclic and Acyclic Data Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal or Vertical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 lbs (0.12 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Base Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-TB, 1734-TBS, 1734-TOP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-4IOL addresses the critical requirements of Industry 4.0 and complex machine diagnostics:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Device Health Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module extracts comprehensive diagnostic data from IO-Link enabled sensors. It detects conditions like lens soiling or internal temperature spikes before a failure occurs, shifting maintenance from reactive to predictive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Device Configuration (ADC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-4IOL stores the configuration parameters of connected sensors. When a technician replaces a damaged sensor, the master module automatically downloads the settings to the new device, eliminating manual setup errors and reducing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Wiring Simplification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes standard 3-wire unshielded cables for intelligent communication. This replaces expensive specialized cables and reduces the overall complexity and cost of the control cabinet wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Process Insights:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeyond simple On\/Off signals, the 1734-4IOL transmits precise process values (such as exact distance measurements or pressure levels) as digital data, preventing signal degradation caused by electromagnetic interference (EMI) in analog circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard digital sensors with the 1734-4IOL?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each channel on the 1734-4IOL supports standard I\/O (SIO) mode. You can connect traditional 24V DC digital sensors to any channel, providing a flexible migration path from standard I\/O to smart IO-Link technology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal base is best for the 1734-4IOL?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend the 1734-TB or 1734-TBS base. Ensure you utilize the 8-terminal configuration to provide adequate power distribution for both the module electronics and the connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support \"Removal and Insertion Under Power\" (RIUP)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like other POINT I\/O modules, the 1734-4IOL allows for replacement while the rest of the system remains operational. This feature is critical for continuous process industries where shutting down the entire I\/O rack is not an option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 1734-4IOL handle power to the sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws 24V DC from the POINT I\/O backplane power bus. It distributes this power to the connected IO-Link devices through the L+ and L- pins, supporting up to the maximum rated current per port as specified in the technical manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52767156994357,"sku":"1734-4IOL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-4IOL.jpg?v=1776736548","url":"https:\/\/www.5gplc.com\/products\/1734-4iol-allen-bradley-point-i-o-4-channel-io-link-master-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}