{"product_id":"1715-tasof8-redundant-i-o-8-channel-analog-output-module-allen-bradley","title":"1715-TASOF8 Redundant I\/O 8-Channel Analog Output Module | Allen Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1715-TASOF8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity, 8-channel analog output module specifically designed for the 1715 Redundant I\/O platform. This module provides critical control signals (0 to 24 mA) to field devices such as valve positioners and actuators in applications requiring non-stop operation. It supports fault-tolerant configurations, allowing the system to maintain control even during hardware transitions. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety-instrumented systems and critical control loops operate with OEM-certified precision.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1715-TASOF8 operates with the following electrical and physical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 24 mA per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Loop Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 to 32V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Power Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.6 W (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V (Continuous) Basic Insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Type Test\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500V AC for 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 to 16 AWG (0.33 to 1.5 mm²)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 Kg (0.57 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.4 cm x 13.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1715-TASOF8 resolves complex availability and signal interference challenges in heavy industry:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Availability Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module integrates into the 1715 redundant bus, allowing for \"Hot Swap\" replacements without dropping the field signal. This eliminates downtime in continuous process industries like oil and gas or chemical refining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Output Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0 to 24 mA capability provides additional headroom beyond the standard 4-20 mA range. This allows the controller to drive signals into over-range conditions for diagnostic purposes or specialized valve calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLow power dissipation (only 0.64 W per field loop) prevents heat buildup in high-density cabinets. This design maintains module longevity and prevents thermal-induced signal drift in high-ambient temperature environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module requires shielded signal ports (Wiring Category 2), which effectively isolates sensitive analog control signals from the electromagnetic noise generated by nearby variable frequency drives and high-voltage motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1715-TASOF8 is specifically built for the 1715 redundant I\/O system. When installed in pairs on a redundant adapter base, it ensures that your analog output signal continues uninterrupted if one module fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of wire should I use for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways use shielded copper wire rated for at least 85 °C (185°F). For optimal signal integrity and compliance with the module’s wiring category, utilize 22 to 16 AWG solid or stranded shielded cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs there isolation between the individual output channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1715-TASOF8 provides 50V continuous isolation between the I\/O ports and the backplane. However, no isolation exists between individual I\/O ports on the same module; therefore, you must ensure your field devices share a compatible common reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the \"Brand New\" status of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe deliver every 1715-TASOF8 in its original factory packaging. Each unit features the authentic Allen Bradley serial number and intact factory seals, ensuring the hardware has never been previously installed or refurbished.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52793183928629,"sku":"1715-TASOF8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1715-TASIF16_2e2a204b-be32-4662-8d67-d4bebcce4eb6.jpg?v=1777356675","url":"https:\/\/www.5gplc.com\/products\/1715-tasof8-redundant-i-o-8-channel-analog-output-module-allen-bradley","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}