{"product_id":"1715-tasib16d-allen-bradley-redundant-i-o-digital-input-simplex-termination-assembly","title":"1715-TASIB16D| Allen Bradley | Redundant I\/O Digital Input Simplex Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1715-TASIB16D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the essential electrical interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715 Redundant I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. This Simplex Digital Input Termination Assembly (TA) facilitates the secure connection between field wiring and the 1715-IB16D digital input module. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock, ensuring the signal integrity required for high-availability automation architectures where unplanned downtime is not an option.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1715 Redundant I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Assembly (TA) - Simplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Modules\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1715-IB16D (16-Point Digital Input)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 to 16 AWG (Solid or Stranded Copper)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 N-m (4.4 lb-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Watts (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.19 lbs (0.09 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Architecture Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1715-TASIB16D enables the integration of 1715-IB16D modules into a larger redundant framework. It ensures that the system maintains continuous operation even if a single I\/O module fails, provided the redundant pair remains active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Wiring Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis compact termination assembly utilizes a specialized terminal block that accommodates wire sizes from 22 to 16 AWG. This flexibility allows engineers to use standard industrial conductors without requiring bulky adapters or additional terminal strips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Mechanical Fastening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe assembly features terminal screws rated for a precise 0.5 N-m torque. This specific clamping force prevents wire loosening due to thermal expansion or mechanical vibration, a frequent cause of intermittent signal loss in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimized Thermal Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a maximum power dissipation of only 4 Watts, the 1715-TASIB16D generates negligible heat. This characteristic prevents the overheating of adjacent modules in high-density redundant I\/O racks, extending the total lifespan of the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1715-TASIB16D support duplex redundant configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"S\" in TASIB16D stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex\u003c\/strong\u003e. While it belongs to the 1715 Redundant I\/O family, this specific termination assembly supports a single 1715-IB16D module. For duplex (redundant pair) applications, you must use the corresponding Duplex Termination Assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich I\/O module is compatible with this termination assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit specifically supports the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1715-IB16D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-point digital input module. Do not attempt to seat other 1715 series modules into this assembly, as the pinouts differ.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended maintenance for the terminal screws?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuring commissioning, apply exactly 0.5 N-m of torque to each terminal. We recommend periodic inspections every 12 months to verify that thermal cycling has not affected the terminal tension.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a new or used part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that this item is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. It arrives in original Allen Bradley packaging with factory seals, ensuring you receive a part with zero previous service hours and full manufacturer-spec performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52531769344309,"sku":"1715-TASIB16D","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1715-TASIB16D.jpg?v=1775197521","url":"https:\/\/www.5gplc.com\/products\/1715-tasib16d-allen-bradley-redundant-i-o-digital-input-simplex-termination-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}