{"product_id":"170180-02-00-bently-nevada-fieldmonitor-transducer-i-o-module","title":"170180-02-00 Bently Nevada FieldMonitor Transducer I\/O Module","description":"\u003cp\u003eConfigured for signal interfacing with 2-wire velocity transducers in FieldMonitor instrumentation platforms, the \u003cstrong\u003eBently Nevada 170180-02-00\u003c\/strong\u003e (\u003cstrong\u003e170180\u003c\/strong\u003e External Transducer I\/O Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Field\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Detail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Assembly\u003c\/td\u003e\n\u003ctd\u003e170180\u003c\/td\u003e\n\u003ctd\u003eFieldMonitor External Transducer I\/O Module base series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Option\u003c\/td\u003e\n\u003ctd\u003e02\u003c\/td\u003e\n\u003ctd\u003eExternal 2-wire velocity transducer interface configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard uncertified configuration \/ baseline option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e170180-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.62 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FieldMonitor external I\/O form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-34 deg C to +85 deg C (-30 deg F to +185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via FieldMonitor system backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Type\u003c\/td\u003e\n\u003ctd\u003e2-wire seismic velocity sensors \/ transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eIntegrates velocity signal to displacement or processes peak velocity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003eDual-channel dynamic velocity signal interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDynamic Signal Integration and Rotor Dynamics Analysis\u003c\/h3\u003e\n\u003cp\u003eThe 170180-02-00 module interfaces directly with 2-wire velocity transducers to acquire low-frequency casing and bearing housing vibration measurements. Internal signal conditioning normalizes dynamic velocity signals across both channels, suppressing cross-talk and noise interference across field wiring runs. By outputting accurate proportional voltage signals to the main FieldMonitor processor, the module enables real-time rotor dynamics tracking, casing vibration trending, and machine protection trip execution under harsh industrial operating conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary transducer types connect to the 170180-02-00 module?\u003c\/p\u003e\n\u003cp\u003eA: The Option 02 configuration is designed specifically for 2-wire moving-coil or piezoelectric velocity transducers used on rotating machinery casings.\u003c\/p\u003e\n\u003cp\u003eQ: How does this module differ from the 170180-01-00 variant?\u003c\/p\u003e\n\u003cp\u003eA: While the -01 option is optimized for -24 VDC Proximitor probes and accelerometers, the -02 variant conditions signals specifically from 2-wire velocity sensors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the FieldMonitor main rack or enclosure power supply is isolated before inserting or removing the I\/O module.\u003c\/li\u003e\n\u003cli\u003eAlign the 170180-02-00 module with the designated backplane slot and push firmly into place until fully seated.\u003c\/li\u003e\n\u003cli\u003eTighten the rear knurled hold-down screws to secure the module against vibration and ensure frame grounding.\u003c\/li\u003e\n\u003cli\u003eConnect 2-wire velocity transducer signal pairs to the assigned terminal blocks using shielded twisted-pair cabling.\u003c\/li\u003e\n\u003cli\u003eGround signal cable shields at a single point (typically at the monitor rack ground terminal) to prevent ground loops.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":53209262620981,"sku":"170180-02-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/170180-02-00.png?v=1784800554","url":"https:\/\/www.5gplc.com\/products\/170180-02-00-bently-nevada-fieldmonitor-transducer-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}