{"product_id":"16644993-001-honeywell-c300-controller-module","title":"16644993-001 Honeywell C300 Controller Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 16644993-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e16644993\u003c\/strong\u003e C300 Controller Module, operates as a dedicated hardware component for real-time control strategy execution and system diagnostics within Honeywell Experion PKS platforms. It handles direct execution of control logic and manages high-speed data exchanges across Fault Tolerant Ethernet (FTE) and I\/O Link networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16644993-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 to 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 chassis form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem chassis powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eC300 Controller Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eHigh-speed embedded processor for real-time control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS, Universal I\/O, Series 8 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eFault Tolerant Ethernet (FTE), I\/O Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eConfigurable redundant pairs with automatic failover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eChassis-mounted (e.g., FC-CPCHAS-0001) with keyed connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Instrumentation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 16644993-001 controller processes field data across I\/O Link backplane channels that support 4-20 mA HART loop protocol device passthrough. Interfacing with Series 8 and Universal I\/O subsystems, the module relies on channel-to-channel isolation at the I\/O rack level to eliminate ground loops and isolate common-mode voltage fluctuations. Temperature processing blocks within the controller's runtime environment evaluate cold junction compensation (CJC) metrics provided by thermocouple input modules. Built-in network drivers maintain deterministic connectivity to FOUNDATION Fieldbus and Profibus PA interface gateways through Fault Tolerant Ethernet (FTE) trunks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is dual-redundant tracking managed between paired 16644993-001 modules?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy is established by pairing two 16644993-001 modules on a C300 chassis. Memory tables, execution state, and clock cycles are mirrored over dedicated sync channels to allow seamless failover without interrupting controller output states.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical constraints when inserting the 16644993-001 into a C300 chassis?\u003c\/p\u003e\n\u003cp\u003eA: The module utilizes keyed connectors for tool-less chassis mounting (such as slot location FC-CPCHAS-0001), preventing physical misalignment during installation or hot-swap procedures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the target chassis slot on the C300 baseplate (e.g., FC-CPCHAS-0001) is clean and free of particulate debris before seating.\u003c\/li\u003e\n\u003cli\u003eAlign the module card edges with the chassis guide slots and apply steady, level pressure until the keyed connectors engage fully.\u003c\/li\u003e\n\u003cli\u003eLock retaining tabs onto the chassis frame to ensure structural stability against operational vibration.\u003c\/li\u003e\n\u003cli\u003eVerify that Fault Tolerant Ethernet (FTE) network cables (FTE A and FTE B trunks) are connected to the designated redundant ports on the chassis backplane.\u003c\/li\u003e\n\u003cli\u003eApply backplane power and observe onboard status LEDs to verify successful self-diagnostics and firmware loading prior to assigning controller execution tasks.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53188063363381,"sku":"16644993-001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/16644993-001.png?v=1784533270","url":"https:\/\/www.5gplc.com\/products\/16644993-001-honeywell-c300-controller-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}