{"product_id":"1492-tifm40f-24-2-allen-bradley-bulletin-1492-fused-output-interface-termination-module","title":"1492-TIFM40F-24-2 | Allen-Bradley | Bulletin 1492 Fused Output Interface Termination Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1492-TIFM40F-24-2 functions as a high-integrity fused output interface termination module (IFM) tailored for functional safety and emergency isolation networks. This specialized digital module acts as the secure physical and electrical bridge that channels signals from two independent ControlLogix 1756-OB16D diagnostic output cards down to terminal field loads. By cross-linking these outputs, the module enables the safety controller to execute dual-channel SIL2 (Safety Integrity Level 2) safety shutdown configurations.\u003c\/p\u003e\n\u003cp\u003eWe supply this component strictly as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee immaculate internal terminal pathways, pristine fuse housings, and uncompromised operation within critical emergency de-energization loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the precise hardware integration parameters, safety profiles, and architecture of this output termination module:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety \u0026amp; Hardware Specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1492-TIFM40F-24-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBulletin 1492 Digital Wiring Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDesigned for SIL2 (Safety Integrity Level 2) Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTarget I\/O Card Pairing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrates two (2) 1756-OB16D ControlLogix Diagnostic Output Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFused Digital Output Interface Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Loop Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 35mm DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnforces Dual-Channel SIL2 Output Interlocking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuit configuration cross-wires output lines from two distinct 1756-OB16D cards into a redundant voting matrix. This architecture allows the safety processor to successfully execute a plant-wide safety shutdown even if one individual output card suffers a frozen or welded transistor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolates Field Short Circuits with Dedicated Fuses:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual per-channel fuses guard each output line on the terminal block. When an actuator or solenoid short-circuits in the field, the corresponding module fuse blows immediately, isolating that specific fault path and preventing high-current surges from damaging the expensive upstream ControlLogix output circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCuts Custom Marshalling Wiring Enclosure Volume:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis integrated module consolidates multiple terminal strips, external fuse blocks, and complicated bridging wires into one compact footprint. Standardized 1492 multi-conductor cables plug directly from the 1756-OB16D cards into the module face, reducing point-to-point wiring time by up to 75% and removing human wiring errors during panel assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I pair this 1492-TIFM40F-24-2 module with standard 1756-OB16 or 1756-OB32 output cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This module features internal trace tracking and pinouts engineered explicitly to split and mirror signals for the dual 1756-OB16D diagnostic output modules required by SIL2 loops. Connecting non-diagnostic or different density cards alters the pin configuration, compromises the safety voting logic, and can cause configuration faults in the Logix safety controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting and orientation practices prevent localized heat spots around the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSnap the module horizontally onto a clean, unpainted 35mm DIN rail inside your Marshalling cabinet. Maintain a minimum of 50mm (2.0 inches) of vertical clearance above and below the module housing to allow natural air convection, which ensures that the heat generated by full-load output loops dissipates safely out of the module casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit contain internal diagnostic indicators to match the 1756-OB16D card capabilities?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module provides physical fuse protection and cross-channel safety routing, while the paired 1756-OB16D ControlLogix cards handle electronic diagnostic logging. The diagnostic output cards sense the open-circuit condition caused by a blown fuse on the 1492 module and report the precise channel fault directly back to the safety controller program.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52902867173685,"sku":"1492-TIFM40F-24-2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1492-TIFM40F-24-2.png?v=1779243325","url":"https:\/\/www.5gplc.com\/products\/1492-tifm40f-24-2-allen-bradley-bulletin-1492-fused-output-interface-termination-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}