{"product_id":"1492-ifm40f-fs24-2-allen-bradley-1492-wiring-system-fusible-interface-module","title":"1492-IFM40F-FS24-2 | Allen-Bradley 1492 Wiring System Fusible Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1794-IFM40F-FS24-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-density pre-wired solution for industrial I\/O management. This Fusible Digital Interface Module (IFM) simplifies the connection between PLC I\/O cards and field devices by providing integrated circuit protection and clear diagnostic feedback. It specifically supports 16 output channels, each featuring individual fuse protection to prevent localized electrical faults from cascading into system-wide failures. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control cabinet benefits from factory-certified protection and optimal signal conductivity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1492-IFM40F-FS24-2 combines 40-pin header connectivity with robust field-side screw terminals.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFusible Digital Interface Module (IFM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Connector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40-Pin Male Header\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 30V AC\/DC (24V Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current per Module\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Amps Total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVisual Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRed LED for Blown Fuse Indication (per channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 to 12 AWG (0.34 to 4 \u003cspan class=\"math-inline\"\u003e$mm^2$\u003c\/span\u003e)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eField Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Terminals per Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstantaneous Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA dedicated red LED monitors each of the 16 channels. These indicators illuminate immediately upon a fuse blow, allowing maintenance personnel to locate faulted field circuits without manual testing or multimeter probing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Cabinet Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 40-pin header interface allows for a single-cable connection to the PLC I\/O module. This \"plug-and-play\" architecture eliminates hundreds of individual wire terminations, reducing labor costs and minimizing human error during panel assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware provides isolation between channels, preventing ground loops and protecting sensitive PLC electronics from field-side voltage spikes. This architecture ensures that a short circuit in one field device does not compromise the operational integrity of the remaining 15 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy-Duty Terminal Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe screw terminals accommodate wire sizes up to 12 AWG. This allows for the use of thicker gauge field wiring to minimize voltage drop over long cable runs, a critical requirement for high-current solenoid and actuator applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of cable should I use with the 1492-IFM40F-FS24-2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use a 1492-series pre-wired cable with a 40-pin female connector (such as the 1492-CABLE series). Ensure the cable length and pinout match your specific Allen-Bradley I\/O card to maintain signal mapping accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the fuses while the module is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the module allows for easy fuse access, always follow standard industrial safety protocols. We recommend de-energizing the specific field circuit before replacing the fuse to prevent arcing and ensure personnel safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both AC and DC voltages?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module operates within a 10 to 30V range for both AC and DC current. However, the LED indicators are specifically optimized for 24V nominal systems to ensure proper brightness for \"Blown Fuse\" alerts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle high-current loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach channel manages up to 2 Amps; however, you must ensure the total current across all 16 channels does not exceed the module's 12 Amp limit. Overshooting this total limit can lead to thermal stress on the internal busbars.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52587287904565,"sku":"1794-OA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1492-IFM40F-FS24-2.jpg?v=1776408713","url":"https:\/\/www.5gplc.com\/products\/1492-ifm40f-fs24-2-allen-bradley-1492-wiring-system-fusible-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}