{"product_id":"1492-aifm16-f-3-allen-bradley-analog-interface-fusion-module","title":"1492-AIFM16-F-3 | Allen Bradley Analog Interface Fusion Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1492-AIFM16-F-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density analog interface module designed to streamline the connection between field devices and PLC I\/O cards. This module manages 16 channels of analog signals, providing dedicated fusing for each circuit to protect sensitive controller inputs from overcurrent conditions. It incorporates a three-terminal-per-input architecture, which simplifies the wiring of 3-wire analog transmitters. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring your control system benefits from factory-spec protection and signal clarity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1492-AIFM16-F-3 utilizes a specialized layout to organize complex analog loops:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Interface (Fusible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–30V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminals per Input\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 (Signal, Power, Ground)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Monitoring\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBlown Fuse Indicators (LED)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DIN Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC Module \/ Rack Accessories\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.51 lbs (0.23 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 16 channels features an individual fuse. This isolation ensures that a fault in a single field transmitter does not compromise the entire I\/O card, preventing localized surges from damaging expensive PLC hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Diagnostic Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes integrated blown fuse indicators. These LEDs illuminate immediately upon fuse failure, allowing maintenance technicians to identify and resolve wiring faults without manual continuity testing across every terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined 3-Wire Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith 3 terminals provided per input, this module eliminates the need for external jumper bars or additional terminal blocks when wiring 3-wire sensors. This configuration reduces cabinet clutter and minimizes potential wiring errors during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignificant Labor Savings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing pre-wired cables (sold separately) to connect the 1492-AIFM16-F-3 to the PLC rack replaces hours of manual point-to-point wiring. This systematic approach accelerates panel assembly and ensures a professional, organized finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust DIN-Rail Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rugged mounting foot secures the module firmly to standard 35mm DIN rails. Its compact 0.51 lb design maintains a high strength-to-weight ratio, ensuring electrical connections remain secure even in high-vibration industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1492-AIFM16-F-3 include the fuses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStandard units typically ship with the required fuses installed. However, we recommend verifying your specific sensor current requirements to ensure the installed fuse ratings provide the optimal level of protection for your loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a 100% brand new Allen Bradley original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee that every 1492-AIFM16-F-3 we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein factory-sealed packaging. We do not provide used or refurbished interface hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for both 4-20mA and 0-10V signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module acts as a physical interface and protection barrier. It handles various analog signal types within the 10-30V DC range, provided the wiring follows the three-terminal per channel layout correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the blown fuse indicators?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn a complex control cabinet with hundreds of wires, identifying a single failed analog loop is time-consuming. The LED indicators provide a visual \"beacon,\" drastically reducing Mean Time to Repair (MTTR) by pointing technicians directly to the faulted circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562816565557,"sku":"1492-AIFM16-F-3","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1492-AIFM16-F-3.jpg?v=1776067969","url":"https:\/\/www.5gplc.com\/products\/1492-aifm16-f-3-allen-bradley-analog-interface-fusion-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}