{"product_id":"1444-tscx02-02rb-allen-bradley-dynamix-terminal-base-module","title":"1444-TSCX02-02RB | Allen Bradley Dynamix Terminal Base Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1444-TS\u003cimg\u003e\u003cimg\u003e\u003cimg\u003eCX02-02RB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the essential foundational interface for the Dynamix™ 1444 series monitoring system. This terminal base provides the physical mounting and electrical connection points required to host 1444-DYN dynamic measurement modules. It facilitates clean signal routing and ensures secure field wiring for high-precision vibration and condition monitoring applications. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, guaranteeing mechanical and electrical compatibility with your Allen Bradley architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1444-TSCX02-02RB features a design optimized for high-fidelity signal transmission:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Base Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDynamix 1444\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Clamp \/ Removable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN-35 Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen-style (IP20 when assembled)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Measurement Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnector Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Grade Copper Alloy\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFront-facing for easy access\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Hot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1444-TSCX02-02RB allows for the installation and removal of measurement modules without disturbing the field wiring. This design minimizes downtime during system upgrades or maintenance cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal bus architecture of the terminal base minimizes crosstalk and electromagnetic interference (EMI), which is critical when processing low-voltage analog signals from accelerometers or proximity probes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe heavy-duty screw clamps secure field conductors firmly, preventing signal loss or intermittent connectivity in high-vibration environments typical of industrial motor control centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Cabinet Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps directly onto standard 35mm DIN rails. Its compact width maximizes the number of monitoring channels you can deploy within a single enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClearly labeled terminal points and accessible test points allow technicians to verify field loops without disconnecting the primary wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1444-TSCX02-02RB include the measurement module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This part number refers specifically to the terminal base. You must purchase the 1444-DYN series modules separately to complete the assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the 02RB and other terminal bases?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1444-TSCX02-02RB is specifically keyed and wired to support the Dynamic Measurement modules. Using the correct base ensures that the internal power and communication pins align perfectly with the module's requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product a brand new Allen Bradley unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We only provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed units\u003c\/strong\u003e. This ensures your system maintains its manufacturer warranty and meets all E-E-A-T industrial safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this base with standard POINT I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. While they may appear similar, the Dynamix 1444 hardware utilizes a specific bus structure and physical keying that is incompatible with standard 1734 POINT I\/O terminal bases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562396152117,"sku":"1444-TSCX02-02RB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1444-TSCX02-02RB.jpg?v=1776051805","url":"https:\/\/www.5gplc.com\/products\/1444-tscx02-02rb-allen-bradley-dynamix-terminal-base-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}