{"product_id":"10313-1-1-fsc-termination-module-honeywell","title":"10313\/1\/1 FSC Termination Module | Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 10313\/1\/1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Termination Module within the Fail Safe Control (FSC) system architecture. This module facilitates the secure interface between field wiring and the internal controller I\/O bus. It provides the physical landing points for critical safety signals while maintaining electrical isolation. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eequipment, providing a vital replacement solution for plants operating legacy FSC infrastructure where the manufacturer has officially discontinued production.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 10313\/1\/1 features a ruggedized PCB design optimized for long-term signal stability in industrial environments:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10313\/1\/1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFSC (Fail Safe Control)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLCs \/ Machine Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 lbs (0.10 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard FSC Chassis \/ Rack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10313\/1\/1 utilizes high-grade terminal blocks that prevent contact resistance buildup. This ensures that low-voltage safety signals reach the I\/O processors without attenuation, eliminating the risk of \"false trips\" caused by signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module layout provides clear, accessible test points for every channel. This engineering choice allows technicians to perform loop checks and voltage measurements directly at the module, significantly reducing downtime during routine maintenance or fault diagnosis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s internal grounding plane effectively drains electromagnetic interference away from the signal path. This protection maintains system stability even when installed in cabinets adjacent to high-power motor control centers or variable frequency drives (VFDs).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its compact 0.22 lbs form factor, the 10313\/1\/1 manages heat dissipation efficiently through specialized copper traces. This prevents thermal stress on connected modules during high-density signal operations in unventilated enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Legacy Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAs a genuine FSC component, this module fits perfectly into existing rack slots. It maintains the exact impedance and electrical characteristics of the original design, removing the need for system re-calibration or safety re-certification after replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 10313\/1\/1 be used with newer Safety Manager systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 10313\/1\/1 specifically supports the legacy FSC (Fail Safe Control) series. While Honeywell Safety Manager evolved from FSC, you must verify the chassis and backplane compatibility in your technical manual, as modern systems often utilize different termination form factors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power to operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 10313\/1\/1 functions as a passive termination interface. It routes signals and power from the main bus and field-side wiring but does not consume additional logic power, simplifying your overall cabinet power budget.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify this is a \"Brand New\" unit if the model is discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery 10313\/1\/1 we ship remains in its original factory packaging with a verified serial number. Unlike refurbished units, our\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock features pristine contact surfaces and zero thermal wear on the PCB, meeting the strict requirements of SIL-rated safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre there specific torque requirements for the terminal screws?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. To ensure a gas-tight connection and prevent wire damage, we recommend following the torque specifications found in the FSC Hardware Installation Guide. Over-tightening can crack the housing, while under-tightening leads to intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52852856652085,"sku":"10313\/1\/1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/10313-1-1.jpg?v=1778316069","url":"https:\/\/www.5gplc.com\/products\/10313-1-1-fsc-termination-module-honeywell","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}