{"product_id":"yokogawa-f3yc08-0c-fa-m3-relay-output-module","title":"Yokogawa F3YC08-0C FA-M3 Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3YC08-0C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-capacity relay output interface for the FA-M3 multi-controller series. This module provides 8 independent relay output points to drive external loads such as solenoid valves, motor starters, and signaling lamps. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak mechanical endurance and electrical safety for your automated control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F3YC08-0C utilizes Single Pole Double Throw (SPDT) architecture to provide maximum flexibility for normally open (NO) and normally closed (NC) circuit requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Contact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPDT (Single Pole Double Throw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 V AC or 30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA (at 5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile SPDT Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard NO-only modules, the F3YC08-0C provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPDT contacts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor every channel. This allows engineers to control both \"power-to-open\" and \"power-to-close\" devices using a single module, simplifying wiring for interlocks and fail-safe hardware configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e. This prevents electrical interference between different output circuits, allowing you to control 250V AC loads and 30V DC signals simultaneously on the same module without risking cross-talk or ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel reliably switches up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 Amperes\u003c\/strong\u003e. This high current rating eliminates the need for interposing relays for many medium-sized solenoids and actuators, reducing both cabinet space requirements and overall system complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides secure, vibration-resistant connections. The clear terminal labeling allows for rapid identification of wiring points during commissioning or onsite troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the SPDT contact type on the F3YC08-0C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SPDT (Single Pole Double Throw) configuration gives you access to both Normally Open (NO) and Normally Closed (NC) contacts for every output. This versatility makes it much easier to design safety interlocks or switch between two different signals using one command.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC voltages on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the F3YC08-0C provides individual channel-to-channel isolation, you can switch 230V AC on one channel and 24V DC on another safely. Always ensure your wiring follows local electrical codes for separating high and low-voltage conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many operations can I expect from the internal relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile mechanical life depends on the specific load type (inductive vs. resistive), using this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule ensures you get the full rated mechanical life from the factory-calibrated relays. For highly inductive loads, we recommend using external surge suppressors to extend contact life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a refurbished or used unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa hardware. Each F3YC08-0C arrives in its original factory anti-static packaging with an intact serial number to guarantee authenticity and full manufacturer-rated performance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550719373621,"sku":"F3YC08-0C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3XC08-0C_e460e738-a356-4902-8b1c-4df83afda7f0.jpg?v=1775722867","url":"https:\/\/www.5gplc.com\/id\/products\/yokogawa-f3yc08-0c-fa-m3-relay-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}