{"title":"Yokogawa Other Series","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eYokogawa Other Series\u003c\/strong\u003e\u003cspan\u003e includes various industrial automation products beyond core PLCs and DCS systems. This category covers specialized modules, controllers, and I\/O devices that expand and maintain Yokogawa automation systems. These products provide reliable performance, scalable integration, and long-term operational stability in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"yokogawa-f3ad08-5r-high-performance-plc-module","title":"Yokogawa F3AD08-5R High-performance PLC Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Yokogawa \u003cstrong\u003eF3AD08-5R\u003c\/strong\u003e High-performance PLC Module is designed for FA-M3 PLC systems, enabling precise analog signal processing and reliable integration in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Yokogawa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Japan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e F3AD08-5R\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 8 analog channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Types:\u003c\/strong\u003e Voltage and current inputs (0–10 VDC, 4–20 mA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit ADC for fine measurement granularity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate:\u003c\/strong\u003e High-speed acquisition for real-time monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel isolation for safe operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;1 ms detection speed\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Fully integrated with Yokogawa FA-M3 PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24V DC ±10%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e Approx. 2.2 cm × 12.4 cm × 12.6 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePrecise Measurement:\u003c\/strong\u003e 16-bit ADC ensures accurate analog signal conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible Input:\u003c\/strong\u003e Supports both voltage and current signals for diverse applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial Reliability:\u003c\/strong\u003e Built for robust operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFast Response:\u003c\/strong\u003e Sub-millisecond detection for real-time monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNoise Reduction:\u003c\/strong\u003e Isolation minimizes interference between channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Seamless compatibility with Yokogawa FA-M3 PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Build:\u003c\/strong\u003e Lightweight and space-efficient for easy installation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eScalable Architecture:\u003c\/strong\u003e Expandable for larger automation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52077172130101,"sku":"F3AD08-5R","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3AD08-5R1__1.jpg?v=1766116657"},{"product_id":"f3ad08-4v-yokogawa-plc-analog-input-module-8-channel-4-20-ma","title":"F3AD08-4V | Yokogawa | PLC Analog Input Module 8-Channel 4–20 mA","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3AD08-4V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Yokogawa is a precision analog input module developed for industrial automation and PLC-based control systems. It provides eight differential input channels and supports both voltage and current signal ranges, ensuring accurate and stable data acquisition in demanding environments. The module’s compact design, high isolation performance, and fast conversion speed make it suitable for process monitoring and control applications requiring reliable analog input performance.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 differential inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–5 V DC, 1–5 V DC, ±10 V DC, 0–10 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–20 mA DC, 4–20 mA DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 MΩ (voltage input), 250 Ω (current input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V DC channel-to-system isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-bit A\/D conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% at 23°C ±2°C, ±0.2% between 0°C and 55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Cycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable from 50 µs to 100 ms per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh noise immunity and minimal drift under temperature variation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eElectrical \u0026amp; Environmental Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5%–95% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation between channels and system bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e28.9 mm (W) × 100 mm (H) × 106.2 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 200 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN-rail compatible design for easy installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3AD08-4V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePLC-based process and machine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous monitoring of industrial sensors and transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog data acquisition in manufacturing and utilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring accurate multi-channel analog inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What signal types are supported by the F3AD08-4V?\u003c\/strong\u003e\u003cbr\u003eA1: It supports both voltage (0–10 V, ±10 V) and current (0–20 mA, 4–20 mA) inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the module provide isolation?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it features 500 V DC electrical isolation between the analog input and the PLC system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the accuracy rating of this module?\u003c\/strong\u003e\u003cbr\u003eA3: ±0.1% under standard operating temperature, ±0.2% over the full range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How many channels are available?\u003c\/strong\u003e\u003cbr\u003eA4: The module provides 8 differential input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52144063447349,"sku":"F3AD08-4V","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3AD08-4V__1.jpg?v=1767754192"},{"product_id":"yokogawa-f3bu13-0n-13-slot-base-module-for-plc-systems","title":"Yokogawa | F3BU13-0N | 13-Slot Base Module for PLC Systems","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3BU13-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Yokogawa is a 13-slot base module designed for use in programmable logic controller (PLC) and distributed control systems (DCS). It serves as the primary mounting platform for CPU units, power supply modules, and I\/O modules, ensuring secure electrical and mechanical connections within the control rack. Engineered for high reliability, the module supports stable signal communication and modular system expansion in industrial automation environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3BU13-0N\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e13 slots for I\/O, CPU, and power modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Style:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRack-type installation with modular architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for Yokogawa F3 series and related PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in bus for backplane signal and power connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade construction for long-term durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNatural air convection, no external fan required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 75°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10% to 90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10% to 90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplies with standard industrial vibration ratings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndoor panel or control cabinet mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3BU13-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for use in a wide range of industrial automation and control systems, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePLC and DCS controller chassis assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation and machine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and utility automation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial monitoring and control racks requiring multiple I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main purpose of the F3BU13-0N base module?\u003c\/strong\u003e\u003cbr\u003eA1: It provides a 13-slot mounting platform for CPU, power, and I\/O modules in Yokogawa PLC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is it compatible with other F3 series components?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, the F3BU13-0N is fully compatible with Yokogawa’s F3 series modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it include integrated power distribution?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it includes an internal backplane bus for power and signal communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can it be used in high-humidity environments?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, within 10–90% relative humidity (non-condensing), it performs reliably.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52144269164853,"sku":"F3BU13-0N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3BU13-0N__1.jpg?v=1767754824"},{"product_id":"f3cx04-0n-yokogawa-temperature-monitoring-module-4-channel-fa-m3","title":"F3CX04-0N  Yokogawa Temperature Monitoring Module 4-Channel FA-M3","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3CX04-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a temperature monitoring module from Yokogawa’s FA-M3 Vitesse series, engineered for accurate and reliable temperature measurement in industrial automation systems. It supports both thermocouple and RTD sensors, offering flexibility across multiple process applications. Designed as a single-slot module for FA-M3 I\/O systems, it ensures stable performance, high isolation, and configurable alarm functionality for precise process supervision.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3CX04-0N\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFA-M3 Vitesse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 temperature input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermocouples and RTDs (Resistance Temperature Detectors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUniversal inputs supporting thermocouple, RTD, and DC voltage signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSampling Period:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 ms (for all four channels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Resolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1°C per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eElectrical isolation between input terminals and internal circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC isolation (between input and system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Functions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpper\/lower limit alarms, with four selectable alarm points per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-slot mounting design compatible with FA-M3 backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust industrial-grade components for long-term reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3CX04-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time temperature monitoring and control in production lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess temperature feedback in power generation, chemical, and semiconductor plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with Yokogawa FA-M3 PLC systems for advanced temperature diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-channel temperature supervision in distributed control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What sensor types are supported by the F3CX04-0N?\u003c\/strong\u003e\u003cbr\u003eA1: It supports both thermocouples and RTDs, as well as DC voltage signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many input channels does the module have?\u003c\/strong\u003e\u003cbr\u003eA2: The module provides 4 isolated temperature input channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it include built-in alarm functions?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, each channel offers four configurable alarm points for upper and lower temperature limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the sampling rate for all channels?\u003c\/strong\u003e\u003cbr\u003eA4: The module performs temperature data updates every 200 milliseconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52144374874421,"sku":"F3CX04-0N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3CX04-0N__1.jpg?v=1767755140"},{"product_id":"f3le12-0t-yokogawa-ethernet-interface-module-for-fa-m3-series","title":"F3LE12-0T | Yokogawa | Ethernet Interface Module for FA-M3 Series","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3LE12-0T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Ethernet interface module developed by Yokogawa for use with the FA-M3 Range-free Multi-controller system. It enables high-speed data communication between PLCs, supervisory systems, and external devices. Supporting both 10BASE-T and 100BASE-TX standards, the module provides flexible networking capabilities for real-time control and efficient system integration in industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eNetwork Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3LE12-0T\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Mbps \/ 100 Mbps auto-negotiation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10BASE-T, 100BASE-TX\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccess Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSMA\/CD (Carrier Sense Multiple Access with Collision Detection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBaseband signaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Cable Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 m between nodes (Cat5e or higher recommended)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Cascade Connection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100BASE-TX: up to 2 segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10BASE-T: up to 4 segments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTCP, UDP, IP, ICMP, ARP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eModule Compatibility\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable CPU Modules:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eF3SP05, F3SP08, F3SP21: up to 2 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eF3SP25, F3SP28, F3SP35, F3SP38, F3SP53, F3SP58, F3SP59: up to 6 modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Yokogawa FA-M3 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables remote programming, monitoring, and data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eElectrical \u0026amp; Physical Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Current Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA (5 V DC internal supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e28.9 mm (W) × 100 mm (H) × 83.2 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 130 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN-rail or chassis mounting (single-slot)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabling Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRJ-45 connector for twisted-pair Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3LE12-0T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting FA-M3 PLC systems to Ethernet-based industrial networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time data exchange between control and monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of distributed process controllers in manufacturing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpanding system communication capability for remote diagnostics and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which communication protocols are supported by the F3LE12-0T?\u003c\/strong\u003e\u003cbr\u003eA1: It supports TCP, UDP, IP, ICMP, and ARP for reliable Ethernet communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum number of Ethernet modules that can be installed?\u003c\/strong\u003e\u003cbr\u003eA2: Depending on the CPU model, up to six modules can be installed simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum communication distance?\u003c\/strong\u003e\u003cbr\u003eA3: Up to 100 meters between connected nodes using standard Cat5e Ethernet cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can the module be used with older FA-M3 CPUs?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it is backward-compatible with most Yokogawa FA-M3 CPU modules supporting Ethernet communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52144400630069,"sku":"F3LE12-0T","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3LE12-0T.jpg?v=1767755470"},{"product_id":"f3lr02-0n-yokogawa-fiber-optic-fa-bus-module-10-mbps-500-m","title":"F3LR02-0N Yokogawa Fiber-Optic FA-Bus Module 10 Mbps 500 m","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3LR02-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a fiber-optic FA-Bus communication module developed by Yokogawa for use in distributed control and automation systems. It provides high-speed and noise-resistant data transmission over long distances, ensuring stable communication between remote I\/O stations and controllers. Designed with a dual-port configuration and daisy-chain topology, it enables efficient and reliable networking in complex industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3LR02-0N\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFiber-Optic FA-Bus Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical fiber-based FA-Bus Type 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 Mbps high-speed data communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Transmission Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 500 meters per segment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePorts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 ports (Send and Receive) for daisy-chain configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Stations per System:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 32 stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh resistance to electromagnetic interference (EMI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated status LEDs for link and communication monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e460–500 mA (nominal at peak load)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFA-Bus Type 2 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDaisy-chain or ring topology supported\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-slot module compatible with Yokogawa FA-M3 system racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eElectrical \u0026amp; Physical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupplied via base unit bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e28.9 mm (W) × 100 mm (H) × 83.2 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical signal separation ensures galvanic isolation between devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNatural air convection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3LR02-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLong-distance communication between remote I\/O nodes in distributed control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control networks requiring noise-immune communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of FA-M3 PLCs in high-EMI industrial areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData transmission in oil \u0026amp; gas, chemical processing, and manufacturing environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What communication standard does the F3LR02-0N support?\u003c\/strong\u003e\u003cbr\u003eA1: It supports the FA-Bus Type 2 protocol over fiber-optic cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum transmission distance?\u003c\/strong\u003e\u003cbr\u003eA2: The module supports communication distances up to 500 meters per segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can multiple modules be linked together?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, the module supports up to 32 stations connected in a daisy-chain configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How does it handle electromagnetic interference?\u003c\/strong\u003e\u003cbr\u003eA4: Optical communication provides high immunity to electrical noise, ensuring stable operation in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52144426189109,"sku":"F3LR02-0N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3LR02-0N1__1.jpg?v=1767755791"},{"product_id":"f3pu30-0s-yokogawa-power-supply-module-100-240v-ac-5v-dc","title":"F3PU30-0S | Yokogawa | Power Supply Module 100–240V AC \/ 5V DC","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3PU30-0S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance power supply module developed by Yokogawa for use in industrial automation and control systems. It provides a stable 5 V DC output from an AC input range of 100–240 V, ensuring reliable operation of PLC and I\/O components. With its wide voltage tolerance, compact form factor, and strong resistance to transient fluctuations, the module is designed for continuous performance in demanding industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3PU30-0S\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100–240 V AC single-phase, 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Tolerance Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e85–264 V AC, 50\/60 Hz ±3 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 VA maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Output Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 V DC regulated output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides constant voltage under varying load conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e20 A maximum at 120 V AC (Ta = 25°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e45 A maximum at 240 V AC (Ta = 25°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMomentary Power Failure Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintains output for up to 20 ms during short power interruptions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOvercurrent and short-circuit protection included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCooling Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNatural convection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModular installation for Yokogawa PLC base units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +75°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10% to 90% RH (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 MΩ minimum at 500 V DC (between input and output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 kV AC for 1 minute between input and output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3PU30-0S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePowering Yokogawa FA-M3 PLC systems and I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial control panels and automation cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystems requiring regulated 5 V DC power from AC sources\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control and process monitoring equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What output voltage does the F3PU30-0S provide?\u003c\/strong\u003e\u003cbr\u003eA1: It provides a regulated 5 V DC output for PLC and module power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the module handle voltage fluctuations?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it operates within 85–264 V AC, maintaining stable output even with input variation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens during a brief power failure?\u003c\/strong\u003e\u003cbr\u003eA3: The module can sustain output for up to 20 milliseconds to prevent system resets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does it include inrush current protection?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it limits inrush current to 20 A (120 V AC) or 45 A (240 V AC) at 25°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52144431759669,"sku":"F3PU30-0S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3PU30-0S.jpg?v=1767756024"},{"product_id":"yokogawa-nfpw442-50-stardom-series-240vac-power-supply-module","title":"Yokogawa NFPW442-50 STARDOM Series 240VAC Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance power conversion module specifically engineered for the Yokogawa STARDOM autonomous controller series. This unit provides a stabilized +5.1 VDC output, essential for energizing backplane logic and CPU operations. Designed for mission-critical industrial applications, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures robust electrical isolation and sophisticated protection circuitry to ensure system availability during voltage transients or overcurrent events.\u003c\/p\u003e\n\u003cp\u003eThe module is optimized for global industrial standards, accepting a wide AC input range and providing a high peak current capacity to handle the startup demands of multiple I\/O modules. Its compact form factor and efficient thermal design allow for high-density installation in standard control cabinets.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated AC Input\u003c\/strong\u003e: 220 V to 240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Input Range\u003c\/strong\u003e: 170 V to 264 V AC (rms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 47 Hz to 66 Hz (50\/60 Hz nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: Maximum 0.7 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current Management\u003c\/strong\u003e: 90 A peak (duration ≤ 5 ms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Output Voltage\u003c\/strong\u003e: +5.1 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSteady State Current\u003c\/strong\u003e: 0 A to 7.8 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePeak Output Current\u003c\/strong\u003e: 11.8 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Power Rating\u003c\/strong\u003e: 40 W continuous (60 W peak capability)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActivation Time\u003c\/strong\u003e: Maximum 100 ms from power-on to stable output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtection and Isolation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage Limit\u003c\/strong\u003e: Automatic clamping at Max. 7 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvercurrent Logic\u003c\/strong\u003e: Shutdown initiates between 4 to 14 seconds when load exceeds 105%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e: 500 V AC for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e: 50 MΩ minimum at 500 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e: 49.7 mm (W) x 130 mm (H) x 146.5 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily utilized within the STARDOM FCN (Field Control Node) architecture. It is commonly found in upstream oil and gas wellhead control, renewable energy management systems, and water treatment facility automation where reliable logic-side power is non-negotiable for safety and data logging.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the overcurrent protection on the NFPW442-50 behave during a fault?\u003c\/strong\u003eThe module is designed with a delayed shutdown. If the current exceeds 105% of the rated capacity, the unit will continue to provide power for approximately 4 to 14 seconds before shutting down. This prevents nuisance trips caused by momentary surges while still protecting the hardware from sustained faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in a redundant power configuration?\u003c\/strong\u003eYes, in STARDOM FCN racks equipped with dual power slots, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits can be installed to provide a redundant power architecture, ensuring the controller remains active even if one power source or module fails.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52421858558261,"sku":"NFPW442-50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-501.jpg?v=1773115419"},{"product_id":"yokogawa-pw442-50-stardom-series-ac-power-supply-module","title":"Yokogawa PW442-50 STARDOM Series AC Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity power regulation module engineered for legacy Yokogawa control environments, specifically within the STARDOM and associated controller series. This unit functions as the primary energy converter for control nodes, transforming high-voltage AC input into the stabilized DC current required for CPU operation and I\/O backplane signaling. Although classified as a discontinued legacy component by the manufacturer, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW442-50 \u003c\/strong\u003eremains a critical spare part for maintaining existing industrial infrastructures that require 220-240V AC power distribution.\u003c\/p\u003e\n\u003cp\u003eConstructed for high-duty cycles, this power supply utilizes high-grade internal capacitors and magnetic components to ensure long-term stability and ripple-free output. It is designed to fit standard Yokogawa power supply nests, providing a secure electrical and mechanical interface for mission-critical automation hardware.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW442-50\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Input Voltage\u003c\/strong\u003e: 220 V to 240 V AC (nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: 50\/60 Hz Dual-frequency support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e: 0.7 A to 4.0 A (load dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e: Stabilized DC output for controller logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Status\u003c\/strong\u003e: Discontinued \/ Legacy Support Item\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e: 1.00 lbs (approximately 0.45 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e: Industrial AC\/DC Power Supply Unit (PSU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLegacy Support and Application\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW442-50-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for facilities utilizing older generations of Yokogawa distributed control hardware. It is commonly found in utility monitoring systems, small-to-medium scale process automation, and regional power substations where the original equipment manufacturer (OEM) hardware must be maintained for compliance and continuity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the S2 suffix in the part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW442-50-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation typically refers to a specific hardware revision or internal component sourcing standard used during its production cycle. It is vital to match this suffix during replacement to ensure 100% mechanical and electrical compatibility with the existing rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I handle the replacement of a discontinued PW442-50-S2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince this module is no longer in active production, it is recommended to maintain a localized stock of \"New Old Stock\" or professionally refurbished units. Before installation, the input voltage settings and fuse integrity should be verified against the specific cabinet schematic.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52421869666613,"sku":"PW442-50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/S9562FA_8589e7a8-2704-46fa-8f44-0b4b42212f91.jpg?v=1773121582"},{"product_id":"nfpw444-50-yokogawa-stardom-series-24v-dc-power-supply-module","title":"NFPW444-50 | Yokogawa STARDOM Series 24V DC Power Supply Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance DC-to-DC power conversion module specifically engineered for the Yokogawa STARDOM autonomous controller platform. This unit serves as the primary energy source for the Field Control Node (FCN) backplane, converting a standard 24 V DC industrial supply into a highly stabilized +5.1 V DC output required for CPU logic and internal bus communication. Designed for mission-critical reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW442-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic performance in environments where AC power is unavailable or where battery-backed DC systems are utilized for maximum uptime.\u003c\/p\u003e\n\u003cp\u003eAs a \"Standard Type\" (non-explosion protected) component, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis intended for general industrial areas. It features advanced voltage regulation to maintain consistent output even during supply fluctuations, protecting sensitive downstream I\/O modules from electrical stress and data corruption.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power Source\u003c\/strong\u003e: 24 V DC Nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Operating Range\u003c\/strong\u003e: 21.6 V to 31.2 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated Output Voltage\u003c\/strong\u003e: +5.1 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current Capacity\u003c\/strong\u003e: 0 to 7.8 A (Continuous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Management\u003c\/strong\u003e: Optimized for high-efficiency heat dissipation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Protection\u003c\/strong\u003e: Standard Type (Basic\/Non-Ex design)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Dimensions\u003c\/strong\u003e: 130 mm (H) x 49.7 mm (W) x 146.5 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Shipping Mass\u003c\/strong\u003e: 1.5 kg (including protective packaging)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eOperational Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily deployed in STARDOM FCN-RTU architectures found in remote oil and gas production sites, solar-powered monitoring stations, and maritime automation systems. It is the ideal choice for modular controller racks that require a direct DC interface to local battery arrays or DC UPS systems, ensuring a seamless power transition during primary utility failure.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NFPW444-50 handle voltage dips in the 24V supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module is rated for a wide input range down to 21.6 V DC. This tolerance allows the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain a stable +5.1 V DC logic supply even during moderate battery discharge or voltage drops caused by high-current loads elsewhere on the same DC loop.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with redundant power configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. In STARDOM FCN enclosures with dual power slots, two\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPW444-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules can be installed to operate in a parallel redundant mode. If one module or its power source fails, the secondary unit assumes the full load without causing a system reset or CPU interruption.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52422066503989,"sku":"NFPW444-50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-501_db7de919-68e9-4afa-81d4-73edfe23f9ef.jpg?v=1773122059"},{"product_id":"yokogawa-nfpw426-50-dc-power-supply-module-stardom-fcn-rtu","title":"Yokogawa NFPW426-50 DC Power Supply Module | STARDOM FCN-RTU","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eNFPW426-50\u003c\/strong\u003e is a compact DC power supply unit designed for Yokogawa STARDOM FCN-RTU low-power controllers. With its wide input range and rugged construction, it is well-suited for remote installations powered by solar arrays or battery systems. The \"-50\" designation identifies the standard version intended for non-hazardous environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e NFPW426-50\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 10–30 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C (industrial grade)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions (L × W × H):\u003c\/strong\u003e 130 × 142.5 × 65.8 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e 0.9 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCooling Method:\u003c\/strong\u003e Passive convection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-rail or panel installation compatible with FCN-RTU systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDesign Life:\u003c\/strong\u003e \u0026gt;100,000 hours MTBF (estimated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e Japan\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWide Input Range:\u003c\/strong\u003e Accepts diverse DC sources including solar panels and batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExtreme Temperature Tolerance:\u003c\/strong\u003e Reliable operation in harsh climates from arctic cold to desert heat\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e Space-efficient design for remote field enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStandard Type (-50):\u003c\/strong\u003e Optimized for general industrial use outside hazardous zones\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote oil and gas wellhead monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWater distribution and pumping stations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSolar-powered telemetry and RTU installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery-backed remote automation sites\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What distinguishes the \"-50\" suffix?\u003c\/strong\u003e  A: It indicates the basic, non-hazardous environment version of the module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can this unit operate in hazardous areas?\u003c\/strong\u003e  A: No, the NFPW426-50 is intended for safe-area installations. Hazardous-rated variants are available separately.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is it suitable for solar-powered sites?\u003c\/strong\u003e  A: Yes, its wide DC input range makes it ideal for solar and battery applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eComparison with Similar Models\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNFPW426-40:\u003c\/strong\u003e Hazardous-area certified version for explosive environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNFPW426-50:\u003c\/strong\u003e Standard model for general industrial use, compact and cost-effective\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52422087770421,"sku":"NFPW426-50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-501_0d4e7a41-0ea4-42d4-8660-991abded1011.jpg?v=1773122631"},{"product_id":"yokogawa-f3sp71-4s-fa-m3-sequence-cpu-module","title":"Yokogawa F3SP71-4S FA-M3 Sequence CPU Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3SP71-4S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the high-performance computational core for the FA-M3 Range-free multi-controller series. This Sequence CPU Module executes complex logic at ultra-high speeds, managing large-scale industrial processes with precision. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system benefits from the latest firmware and factory-certified hardware integrity.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F3SP71-4S utilizes a stored-program, repetitive operation mode to maintain consistent cycle times for critical logic.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eControl Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStored program, repetitive operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Control Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefreshing method \/ Direct I\/O instructions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming Language\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eObject ladder language\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstruction Set\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40 Basic \/ 445 Application instructions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB 2.0 (12 Mbps) \u0026amp; Ethernet Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExpansion Slot\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSD Memory Card (SDHC compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSelf-Diagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMemory, CPU, I\/O, and Syntax checking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis CPU processes 485 distinct instructions, allowing it to handle intricate mathematical calculations and rapid sequence logic simultaneously. The \"Refreshing method\" ensures the CPU updates all I\/O states systematically, maintaining predictable performance in high-speed manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Communication Hub:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe onboard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet and USB 2.0 ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeliminate the need for separate communication modules in many applications. This direct connectivity streamlines data acquisition for SCADA systems and simplifies local programming via standard PC interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Diagnostic Engine:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3SP71-4S constantly monitors its own hardware health. It detects memory errors, CPU malfunctions, and I\/O irregularities in real-time. This proactive error detection prevents the controller from executing corrupted logic, shielding downstream machinery from damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Data Storage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSDHC-compatible SD card slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates large-scale data logging and easy project backup. Maintenance engineers can update program versions or retrieve historical process data without a permanent PC connection, significantly reducing onsite troubleshooting time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat programming environment does the F3SP71-4S require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module utilizes Yokogawa's Object Ladder Language. You typically use the WideField3 programming software to develop, debug, and download logic to this CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this CPU support high-capacity SD cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The SD memory card slot is SDHC compatible. This allows you to use higher-capacity cards for storing extensive trend data, recipe files, or project documentation directly on the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I perform direct I\/O control with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. While it primarily uses the refreshing method for standard operations, it also supports \"Direct I\/O instructions.\" This allows the CPU to bypass the standard refresh cycle for time-critical inputs or outputs that require immediate action.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit a refurbished or used model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We offer only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa hardware. Each F3SP71-4S arrives in its original factory packaging, complete with a unique manufacturer serial number to guarantee its origin and service life\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550637027637,"sku":"F3SP71-4S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3SP71-4S.jpg?v=1775720823"},{"product_id":"yokogawa-fx1006-4-3-l-fx1000-paperless-recorder","title":"Yokogawa FX1006-4-3-L FX1000 Paperless Recorder","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FX1006-4-3-L\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebelongs to the high-performance FX1000 Daqstation series, designed for precision data acquisition and visualization. This 6-channel paperless recorder captures critical process variables with a high-speed measurement interval. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a secure and reliable digital recording solution for pharmaceutical, heat treatment, and environmental monitoring applications.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe FX1006 model code defines the specific hardware capabilities and regional settings:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFX1006:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6-channel input model, shortest measurement interval of 1 second.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with a CompactFlash (CF) card slot; includes a 512MB medium.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMulti-language support (English, Chinese, German, etc.) with Fahrenheit and DST settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-L:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced insulation; supports 400 VAC (50\/60 Hz) withstanding voltage for 1 minute.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption \/A1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides 2-point alarm relay outputs (C-contact).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption \/M1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdds advanced Mathematical functions and Report generation capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOption \/USB1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes a front-facing USB interface port for easy data retrieval.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis unit integrates robust input protection with flexible data management features.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eShortest interval: 1 Second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Storage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile flash memory\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Media\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e512MB CF Card (Included)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC between measuring input terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB 1-port, CF Card Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMath Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStatistical calculations, report functions (\/M1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Points, C-contact (\/A1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Signal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-L suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates superior insulation. The recorder withstands up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e400 VAC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween measuring terminals, protecting the internal circuitry from signal surges and ground loops in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSophisticated Data Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/M1 option\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransforms the recorder into a computational tool. It executes complex mathematical formulas in real-time and generates automated daily or monthly reports, eliminating the need for manual post-processing of data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure External Archiving:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCF card slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a stable, vibration-resistant medium for long-term data storage. Unlike standard consumer-grade media, the included 512MB industrial-grade card ensures data integrity in high-temperature or high-vibration control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultilingual Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-3 language option\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports ten major languages, including English and Chinese. This allows global operators to navigate menus and view alarm logs in their native tongue, reducing human error during critical process shifts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I retrieve data from the FX1006-4-3-L?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can retrieve data in two ways: by removing the CF card and reading it on a PC, or by connecting a USB drive to the front panel via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/USB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eport. The unit saves data in binary files to prevent tampering, which you can view using Yokogawa's free DAQStandard software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I monitor temperature and voltage simultaneously on different channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each of the 6 channels supports universal inputs. You can independently configure each channel to accept thermocouples (TC), resistance temperature detectors (RTD), DC voltage, or mA signals (with an external shunt resistor).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \/A1 Alarm Option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/A1 option\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides physical relay contacts. You can trigger external sirens, signal towers, or interlock circuits when a measured variable exceeds your pre-set safety limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this recorder factory-calibrated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. As a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit, it arrives with factory-standard calibration and a certificate of conformance. We deliver the product in its original Yokogawa protective packaging to ensure it reaches your facility in pristine condition.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550641746229,"sku":"FX1006-4-3-L","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FX1006-4-3-L.jpg?v=1775721036"},{"product_id":"yokogawa-f3xc08-0c-fa-m3-dry-contact-discrete-input-module","title":"Yokogawa F3XC08-0C FA-M3 Dry Contact Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3XC08-0C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance discrete input interface for the FA-M3 multi-controller platform. This module features 8 independent, fully isolated channels designed to monitor dry contacts and no-voltage discrete signals. We provide this hardware as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring absolute signal precision and hardware longevity for your mission-critical automation loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F3XC08-0C utilizes transformer-based isolation to maintain superior signal integrity across all 8 channels.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry Contact \/ No-Voltage Discrete Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransformer-based (Channel-to-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eON\/OFF Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eON ≤ 200 \u003cspan class=\"math-inline\"\u003e$\\Omega$\u003c\/span\u003e \/ OFF \u003cspan class=\"math-inline\"\u003e$\\ge$\u003c\/span\u003e 100 k$\\Omega$\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\ge$\u003c\/span\u003e 5 V DC, \u003cspan class=\"math-inline\"\u003e$\\ge$\u003c\/span\u003e 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Stages: 0 µs, 62.5 µs, 250 µs, 1 ms, 16 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 500 mA (Internal 5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.9 mm (W) × 100 mm (H) × 83.2 mm (D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-High-Speed Signal Capture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module offers a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 µs response setting\u003c\/strong\u003e. This allows the CPU to capture instantaneous triggers from high-speed mechanical limit switches or optical sensors without the typical lag associated with standard PLC input filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Ground Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard modules that share a common return, the F3XC08-0C provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseparate common terminal per channel\u003c\/strong\u003e. This full isolation allows the module to interface with multiple external systems operating at different ground potentials without risking cross-talk or equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior EMI Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor electrically noisy environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 ms selectable filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides robust debounce and noise rejection. This feature ensures stable monitoring of pushbuttons and heavy-duty relay contacts near high-frequency drives or large motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer-Based Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated transformer isolation provides a physical barrier against high-voltage transients. This hardware-level protection shields the FA-M3 backplane and CPU from external electrical faults on the field side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of \"Dry Contact\" inputs for my system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDry contact inputs do not require the field device to provide a voltage source. The F3XC08-0C provides the sensing voltage internally, simplifying your wiring and allowing you to monitor simple mechanical switches or relay contacts without adding external power supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I set different response times for each channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe response filter typically applies to the module as a whole. You should select the filter stage that matches the fastest signal requirement on the module or group signals with similar speed requirements onto the same F3XC08-0C unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module fit into any FA-M3 base unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The F3XC08-0C occupies a standard I\/O slot on any FA-M3 series base module. Its compact width of 28.9 mm allows for high-density I\/O configurations in space-constrained control cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm this unit is brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Yokogawa factory packaging. Each module carries a unique serial number and factory seal, ensuring it has never been installed or refurbished.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550700073269,"sku":"F3XC08-0C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3XC08-0C.jpg?v=1775722437"},{"product_id":"f3xd16-3f-yokogawafa-m3-dc-input-module","title":"F3XD16-3F | YokogawaFA-M3 DC Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3XD16-3F\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density discrete input interface for the FA-M3 multi-controller platform. This module captures digital signals from field devices such as limit switches, proximity sensors, and pushbuttons, converting them into logic levels for the CPU. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak signal integrity and hardware longevity for your automated production lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F3XD16-3F utilizes advanced optical isolation to protect the system backplane from field-side electrical noise.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Voltage (Supports both Sink and Source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 mA per point (at 24 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotocoupler Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Current Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e65 mA (at 5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Wiring Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSink and Source (NPN\/PNP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput types. This flexibility allows engineers to standardize on a single module part number regardless of the field sensor's polarity, simplifying inventory management and wiring schematics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephotocoupler isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecreates a physical light-based barrier between the 24V field circuits and the sensitive 5V logic of the FA-M3 backplane. This prevents ground loops and protects the CPU from high-voltage transients common in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Power Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDrawing only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e65mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the internal system power supply, the F3XD16-3F minimizes the heat load within the PLC rack. This low power consumption allows for higher module density without exceeding the power budget of the base unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for the FA-M3 \"Range-free\" architecture, the module ensures high-speed input refreshing. This capability proves critical for capturing instantaneous pulses from fast-moving machinery or high-frequency limit triggers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific polarity for the 24V DC inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The F3XD16-3F features a flexible circuit design that accepts both positive (Source) and negative (Sink) logic. You can adapt the wiring based on your specific sensor requirements and common-line configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the status indicators assist in troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe front panel includes LED indicators for all 16 channels. These lights allow maintenance technicians to verify signal presence at a glance, significantly reducing the time required to diagnose field-side wiring faults or sensor failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a defective F3XD16-3F without re-programming the PLC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Since this is a hardware-level I\/O module, replacing a failed unit with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eF3XD16-3F requires no software changes, provided the station configuration and slot assignment remain the same.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 24V DC rated voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 24V DC standard provides superior noise margin compared to lower voltage levels. This ensures the module accurately distinguishes between a \"High\" signal and background electrical interference, reducing the risk of false triggers in electrically \"noisy\" factory environments.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550715736373,"sku":"F3XD16-3F","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3XC08-0C_21ce2f24-f85c-4a3c-96f2-c5f107d1d582.jpg?v=1775722689"},{"product_id":"yokogawa-f3yc08-0c-fa-m3-relay-output-module","title":"Yokogawa F3YC08-0C FA-M3 Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3YC08-0C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-capacity relay output interface for the FA-M3 multi-controller series. This module provides 8 independent relay output points to drive external loads such as solenoid valves, motor starters, and signaling lamps. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak mechanical endurance and electrical safety for your automated control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F3YC08-0C utilizes Single Pole Double Throw (SPDT) architecture to provide maximum flexibility for normally open (NO) and normally closed (NC) circuit requirements.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Contact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPDT (Single Pole Double Throw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 V AC or 30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Switching Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mA (at 5 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Terminal Block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile SPDT Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard NO-only modules, the F3YC08-0C provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPDT contacts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor every channel. This allows engineers to control both \"power-to-open\" and \"power-to-close\" devices using a single module, simplifying wiring for interlocks and fail-safe hardware configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFull Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e. This prevents electrical interference between different output circuits, allowing you to control 250V AC loads and 30V DC signals simultaneously on the same module without risking cross-talk or ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel reliably switches up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 Amperes\u003c\/strong\u003e. This high current rating eliminates the need for interposing relays for many medium-sized solenoids and actuators, reducing both cabinet space requirements and overall system complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides secure, vibration-resistant connections. The clear terminal labeling allows for rapid identification of wiring points during commissioning or onsite troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the SPDT contact type on the F3YC08-0C?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe SPDT (Single Pole Double Throw) configuration gives you access to both Normally Open (NO) and Normally Closed (NC) contacts for every output. This versatility makes it much easier to design safety interlocks or switch between two different signals using one command.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix AC and DC voltages on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Because the F3YC08-0C provides individual channel-to-channel isolation, you can switch 230V AC on one channel and 24V DC on another safely. Always ensure your wiring follows local electrical codes for separating high and low-voltage conductors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow many operations can I expect from the internal relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile mechanical life depends on the specific load type (inductive vs. resistive), using this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule ensures you get the full rated mechanical life from the factory-calibrated relays. For highly inductive loads, we recommend using external surge suppressors to extend contact life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a refurbished or used unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa hardware. Each F3YC08-0C arrives in its original factory anti-static packaging with an intact serial number to guarantee authenticity and full manufacturer-rated performance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550719373621,"sku":"F3YC08-0C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3XC08-0C_e460e738-a356-4902-8b1c-4df83afda7f0.jpg?v=1775722867"},{"product_id":"acm12-yokogawa-fa-m3-rs-422-rs-485-communication-module","title":"ACM12 | Yokogawa FA-M3 RS-422\/RS-485 Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ACM12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized serial communication interface within the FA-M3 range-free multi-controller platform. This module enables high-speed data exchange between the PLC rack and external peripheral devices via industrial-standard serial protocols. Although the manufacturer has officially discontinued this series, we supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efactory-sealed stock, providing a critical replacement path for maintaining legacy automation infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ACM12 integrates seamlessly into standard FA-M3 racks to provide robust differential signaling capabilities.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSerial Communication Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-422 \/ RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Status LED Indicators\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.8 cm x 22.9 cm x 5.1 cm (7.0\" x 9.0\" x 2.0\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg (1 lbs 13.0 oz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Serial Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ACM12 supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-422 and RS-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocols. This flexibility allows engineers to establish point-to-point or multi-drop network topologies, facilitating communication with varied hardware such as HMI panels, variable frequency drives (VFDs), and analytical instruments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a differential signaling architecture to reject common-mode noise. This ensures reliable data transmission even in environments with heavy electromagnetic interference (EMI) from large motors or high-voltage switchgear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Diagnostic Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-facing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStatus LED Indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide real-time visibility into module health and data traffic. Maintenance teams can instantly identify communication faults or power issues without connecting external diagnostic software, significantly reducing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Mechanical Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003escrew terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field wiring. These connectors provide high vibration resistance and ensure low-contact resistance for long-term operational stability in harsh industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ACM12 compatible with modern FA-M3 backplanes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The ACM12 follows the standard FA-M3 rack-mount form factor. It installs directly into any compatible I\/O slot, allowing you to maintain or expand existing systems without upgrading the entire controller architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between RS-422 and RS-485 modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMode selection typically occurs through internal hardware jumper settings or specific software configuration parameters within the PLC project. Refer to the FA-M3 communication manual for exact pinout requirements for 2-wire vs. 4-wire configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I still obtain a new unit if the manufacturer has discontinued the model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. While Yokogawa has moved to newer generations, we specialize in providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal \"new-old-stock\" (NOS) units. These modules remain in their original factory packaging to guarantee they have never seen field service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable distance supported by the ACM12?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing high-quality shielded twisted-pair (STP) cable, the RS-422\/485 interface on the ACM12 typically supports distances up to 1,200 meters. For longer runs or extremely noisy paths, we recommend utilizing dedicated signal repeaters or optical isolators.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52550909460789,"sku":"ACM12","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ACM12.jpg?v=1775725754"},{"product_id":"yokogawa-nfsbt02-basic-modular-controller-cpu-unit","title":"Yokogawa NFSBT02 Basic Modular Controller CPU Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFSBT02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-efficiency Basic Modular Controller (CPU unit) designed to drive distributed control applications and independent process loops. This compact processing engine executes complex control logic while managing localized I\/O systems with high precision. We provide this hardware as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your remote I\/O stations and small-scale automation loops operate with factory-guaranteed stability and speed.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFSBT02 integrates a high-speed microprocessor and a robust memory architecture to maintain deterministic control performance.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControl Logic Execution and I\/O Management\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModular Controller \/ CPU Unit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed industrial grade\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile and Volatile memory integrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mm × 100 mm × 42 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDirect Backplane Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100% Brand New Original\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Distributed Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe NFSBT02 excels in remote I\/O station management. Its specialized architecture allows it to function as a standalone processing node, reducing the computational load on the central plant controller and minimizing network traffic by processing logic at the edge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint for High Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 42mm depth allows for installation in shallow cabinets and space-constrained field enclosures. Engineers maximize cabinet density by pairing this controller with high-density I\/O modules, significantly lowering the overall installation cost per point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal non-volatile and volatile memory configurations ensure that the controller maintains rapid cycle times. This hardware-level optimization guarantees that your process loops respond consistently to input changes, which is critical for maintaining product quality in chemical or thermal applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular design facilitates easy interfacing with various communication and I\/O modules. You can adapt the NFSBT02 to specific process needs by simply adding or changing modules on the backplane, providing a flexible migration path as your automation requirements evolve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Yokogawa NFSBT02 suitable for central control in large-scale plants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NFSBT02 operates as a \"Basic\" controller. It performs best in small-to-medium applications or as a distributed controller within a larger system. For centralized control of massive plant-wide networks, we recommend Yokogawa’s high-capacity duplexed CPU models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model support CPU redundancy (Duplexed mode)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. As a basic modular unit, the NFSBT02 does not support redundant or duplexed CPU configurations. It provides a cost-effective, high-performance solution for non-critical loops or distributed architectures where the higher-level system manages overall network availability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I install the NFSBT02 into my existing system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller integrates directly into the system's backplane. Ensure that the backplane pins are clean and that the unit is securely seated before applying power. The high-speed interface will automatically manage data flow between the processor and adjacent I\/O modules upon system initialization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify that the unit is new and original?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply every NFSBT02 as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand-new, original factory-sealed component\u003c\/strong\u003e. Each unit carries a unique manufacturer serial number and arrives in original anti-static packaging, guaranteeing that the hardware has never been used in a field environment.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551114621237,"sku":"NFSBT02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDR541-P002_3800ddbd-6429-44a7-b696-9786b3ab0b8c.png?v=1775728238"},{"product_id":"nfti3s-00-yokogawa-stardom-fcn-analog-input-module","title":"NFTI3S-00 | Yokogawa | STARDOM FCN Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFTI3S-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog input interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM FCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. This module integrates up to 16 channels, converting field sensor signals into precise digital data for real-time process monitoring. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains peak performance without the risks associated with refurbished hardware.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFTI3S series utilizes a modular suffix system to define specific hardware capabilities:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFTI3S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 16-Channel Analog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic configuration (No specialized explosion-proof coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFTI3S-00 offers high-speed data acquisition with the following technical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 non-isolated input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA \/ 1 to 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.2% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-bit A\/D conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Refresh Cycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 ms (Ideal for dynamic process loops)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 Ω (Power ON) \/ 300 kΩ (Power OFF)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation between input and system circuitry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10 to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e350 mA at 5 V DC \/ 500 mA at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFTI3S-00 solves specific field integration challenges through superior engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy packing 16 channels into a single 0.3 kg module, this unit maximizes I\/O density. Engineers reduce the total number of racks required, significantly lowering cabinet hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptical isolation protects your system logic from field-side electrical surges and noise. The module withstands 1000 V AC for one minute, preventing ground loops from damaging the central processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response Times:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 50 ms step response time and a 20 ms refresh cycle, the NFTI3S-00 tracks fast-changing variables like pressure spikes or flow fluctuations, enabling more precise PID control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Field Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports both pressure clamp terminals and MIL connector cables, allowing for rapid pre-wiring or traditional point-to-point field connections depending on the project scale.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both current and voltage inputs simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the NFTI3S-00 accepts both 4-20 mA and 1-5 V DC signals. However, ensure that the external wiring and software configuration match the specific signal type for each channel to maintain accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features high input impedance (300 kΩ) when powered off. This design prevents the module from loading down the remaining field loops or causing signal drops in multi-drop configurations during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a current-version product for the STARDOM series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. This is a 100% brand new, current-generation NFTI3S-00 module. It fully supports the latest FCN-500 and FCN-RTU controllers within the Yokogawa STARDOM architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551156269365,"sku":"NFTI3S-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDR541-P002_fdb7510f-cb8e-4f79-9ee1-68d1e19f7001.png?v=1775728716"},{"product_id":"yokogawa-nfai143-s50-stardom-16-channel-analog-input-module","title":"Yokogawa NFAI143-S50 STARDOM 16-Channel Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFAI143-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog input interface specifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller network. This module facilitates the precision monitoring of field instruments by converting standard current signals into digital data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your facility maintains peak measurement integrity without the failure risks of refurbished components.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFAI143\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 16-Channel Isolated Analog Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type for general industrial deployment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-performance hardware revision for STARDOM controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic configuration (No specialized conformal coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels (Individual Electrical Isolation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA \/ 0 to 20 mA DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa STARDOM FCN\/FCJ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e482 (W) x 210 (H) x 220 (D) mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-precision A\/D conversion for sensitive process variables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike non-isolated modules, the NFAI143-S50 isolates every input channel. This prevents ground loops and ensures that a surge on one sensor does not propagate to other channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePacking 16 isolated channels into a 0.3 kg module maximizes rack density, reducing the total number of sub-nodes required for large-scale deployments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI\/RFI Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module hardware employs advanced shielding to filter out electromagnetic interference common in high-voltage industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the NFAI143-S50 handle 0-20 mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports both 4-20 mA and 0-20 mA signal types, configured via the STARDOM controller software settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a separate external power supply for the loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Depending on your wiring configuration (2-wire vs. 4-wire transmitters), you may need to provide loop power via the baseplate or an external 24V DC supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the unit shipped in factory-sealed packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: We guarantee every NFAI143-S50 arrives in its original Yokogawa factory box with the manufacturer’s certificate of origin and security seal.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551663583541,"sku":"NFAI143-S50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-501_e4f9db74-ab0d-42f4-bba1-3d8abbdf8eb1.jpg?v=1775731563"},{"product_id":"yokogawa-nfap135-s50-pulse-input-module-stardom","title":"Yokogawa NFAP135-S50 Pulse Input Module | STARDOM","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFAP135-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance pulse input interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. This module captures frequency-based signals from flow meters, tachometers, and encoders, converting high-speed pulses into precise digital data. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing a factory-certified solution for mission-critical data acquisition where signal timing and isolation remain paramount.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFAP135 series utilizes a modular suffix system to define its hardware generation and functional compatibility:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFAP135\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 8-Channel Isolated Pulse Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type for industrial process applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-performance hardware revision for FCN\/FCJ controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic configuration (No specialized conformal coating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFAP135-S50 handles high-frequency inputs with superior electrical isolation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 isolated channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Frequency Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Refresh Cycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 2-wire (Contact ON\/OFF, voltage\/current pulse) and 3-wire (Voltage pulse)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimum detectable width of 40 μs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmitter Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelectable 12 V DC or 24 V DC output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V AC for 1 minute (Channel-to-channel and channel-to-system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure clamp terminal or MIL connector cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFAP135-S50 solves specific field integration challenges through robust electrical engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 500 V AC isolation between individual channels. This architecture prevents electrical noise or ground loops from affecting adjacent inputs, ensuring accurate frequency measurement even in environments with heavy motor interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Transmitter Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit eliminates the need for external power supplies for field sensors. By supplying selectable 12V or 24V DC directly to 2-wire or 3-wire transmitters, it simplifies cabinet wiring and reduces hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Chattering Filter Function:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe software-selectable filter eliminates mechanical contact bounce (chattering). This ensures the controller counts only valid pulses, preventing false data readings in systems utilizing relay or transistor switch inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Determinism:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA rapid 2 ms data refresh cycle ensures the STARDOM controller tracks instantaneous changes in flow rates or rotational speeds. This minimizes control lag in high-speed PID loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Termination Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can choose between pressure clamp terminals for direct wiring or MIL connector cables for rapid, pre-fabricated system assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the NFAP135-S50 supply power to a 4-20mA transmitter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. While this module provides 12\/24V DC power, it specifically captures pulse and frequency signals. For 4-20mA analog signals, you must use an analog input module like the NFAI143.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle high-frequency current pulses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The NFAP135-S50 internally converts current pulses into voltage signals. You can select the appropriate shunt resistance (OFF\/200\/500\/1000 Ω) to match the impedance requirements of your field sensor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The STARDOM FCN architecture supports hot-swapping of I\/O modules; however, you must ensure the baseplate configuration and software settings allow for online replacement to avoid process interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this a 100% original Yokogawa part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We guarantee every NFAP135-S50 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, shipped in the manufacturer’s factory-sealed packaging with full traceability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551670726965,"sku":"NFAP135-S50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-50_89fb36d3-9e7f-4529-a957-f67239290117.jpg?v=1775731808"},{"product_id":"nfar181-s50-yokogawa-stardom-rtd-input-module","title":"NFAR181-S50 | Yokogawa STARDOM RTD Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFAR181-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision RTD (Resistance Temperature Detector) input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. It interfaces directly with Pt100 sensors in a 3-wire configuration to provide accurate temperature monitoring across a vast thermal spectrum. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your process control system benefits from factory-certified calibration and high-integrity electrical isolation.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFAR181 series utilizes Yokogawa's modular suffix system to define hardware revision and compatibility:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFAR181\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 12-Channel Isolated RTD Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type for industrial process monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware Revision: Optimized for FCN\/FCJ controller backplanes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Option: Standard configuration without specialized coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFAR181-S50 delivers superior measurement performance for critical temperature loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 electrically isolated channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePt100 (3-wire configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-200°C to 800°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.15°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 second data refresh cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC for 1 minute (Input to System)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 mA (RTD excitation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Drift:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax. 30 ppm\/°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure clamp terminal or MIL connector cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFAR181-S50 addresses specialized thermal monitoring challenges through refined electrical design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Thermal Tracking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module achieves an accuracy of ±0.15°C, making it suitable for sensitive chemical reactions and cryogenic storage where minute temperature deviations compromise product quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC isolation protects the controller logic from field-side electrical surges. This architecture prevents ground loops and localized interference from affecting the accuracy of adjacent channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Burn-out Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable burn-out detection identifies sensor failures or broken lead wires within 60 seconds. This proactive diagnostic feature prevents the control system from acting on erroneous data during a hardware fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLead Wire Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 3-wire configuration automatically compensates for lead wire resistance. This ensures high-accuracy readings even when sensors sit at a significant distance from the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Input Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintaining 2 MΩ resistance regardless of power status ensures the module does not load the signal source, preserving measurement linearity throughout the entire temperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFAR181-S50 support 2-wire or 4-wire Pt100 sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module specifically utilizes a 3-wire configuration to optimize lead wire compensation. While you can wire a 2-wire sensor by shorting the appropriate terminals, we recommend 3-wire sensors to maintain the rated ±0.15°C accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module indicate a sensor failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module employs a configurable burn-out detection function. Upon detecting an open circuit (burn-out), the system triggers a diagnostic alarm within 60 seconds, allowing the controller to enter a pre-defined fail-safe mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module replace older STARDOM RTD modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \"S50\" suffix represents the current hardware revision. It typically maintains backward compatibility with STARDOM FCN\/FCJ controllers, but you should verify your existing software and baseplate version to ensure seamless integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the unit shipped with a factory calibration certificate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: We provide every NFAR181-S50 in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Yokogawa packaging. The factory seals ensure the module retains its original calibration and passes all manufacturer quality-control benchmarks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551672955189,"sku":"NFAR181-S50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-501_6dc917d6-8f85-487a-9bf9-f5208797aee3.jpg?v=1775731955"},{"product_id":"nfdv151-p60-yokogawa-stardom-digital-input-module","title":"NFDV151-P60 | Yokogawa STARDOM Digital Input Module","description":"\u003ch3\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eProduct Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV151-P60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density digital input interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. This module facilitates the acquisition of discrete signals from field devices such as limit switches, proximity sensors, and push buttons. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control architecture benefits from factory-certified timing accuracy and high-voltage isolation.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFDV151 configuration follows a specific hardware logic designed for industrial scalability:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV151\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 32-Channel Digital Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density Parallel type for standard I\/O processing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware Revision: Optimized for high-speed bus communication\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Option: Standard configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV151-P60 provides robust electrical characteristics for reliable signal detection:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 channels (Common minus side every 16 channels)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput ON Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18 to 26.4 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput OFF Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.0 VDC or less\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.1 mA ±20% per channel (at rated voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage (Signal to System):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2000 V AC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Response Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤ 8 ms (Status input mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum ON Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 ms (Push button mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA (5 V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 mm (W) x 30 mm (H) x 110 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV151-P60 optimizes field-to-controller communication through several key technical advantages:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy incorporating 32 channels into a compact 100mm wide footprint, this module significantly reduces the required rack space. Engineers can manage high-volume discrete I\/O without expanding the physical cabinet size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Dielectric Strength:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2000V AC withstanding voltage provides a robust barrier between field-side electrical surges and the sensitive system logic. This protection prevents catastrophic failure of the central processor during external ground faults or lightning strikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Mode Detection Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports both standard status monitoring and specialized push-button detection. The push-button mode utilizes a 20ms detection window to filter out mechanical contact chatter, ensuring the system registers only deliberate operator actions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Termination Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupport for both Pressure Clamp Terminals and MIL Connector Cables allows for rapid pre-wiring or traditional point-to-point field termination. This flexibility accelerates the commissioning phase during plant startups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the NFDV151-P60 handle 24V AC signals?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA: No. The module accepts only 24V DC rated input. Applying AC voltage will damage the internal optocouplers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the \"Common Minus\" configuration work for the 32 channels?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA: The module divides the 32 channels into two groups of 16. Each group shares a common negative terminal, allowing you to isolate different power sources for separate groups of field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum allowable voltage for this module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA: The unit withstands an instantaneous maximum of 30.0 VDC. Operating the module continuously above 26.4 VDC may cause overheating or premature failure of the input circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require external power for the system side?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA: No. The module draws its primary operating current (500 mA at 5V DC) directly from the STARDOM baseplate bus. However, you must provide the 24V DC field-side power for the input signals.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551675740469,"sku":"NFDV151-P60","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFPW442-50_48b0d4ce-3989-45fc-bdde-0150f480b2a8.jpg?v=1775732116"},{"product_id":"yokogawa-nflr121-s50-stardom-rs-422-rs-485-communication-module","title":"Yokogawa NFLR121-S50 STARDOM RS-422\/RS-485 Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFLR121-S50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-performance serial communication interface for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM FCN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. This module provides two independent ports for RS-422 or RS-485 connectivity, enabling seamless integration with third-party PLCs, motor drives, and field instruments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control network maintains high-speed data integrity and deterministic communication across industrial serial links.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFLR121 nomenclature follows the Yokogawa modular classification system for STARDOM I\/O and communication units:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFLR121\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: RS-422\/RS-485 Communication Module (2 Ports)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Type for general industrial automation environments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware Revision: Optimized for modern FCN controller backplanes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Option: Standard configuration without specialized coating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFLR121-S50 offers versatile configuration options for complex multipoint networks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePort Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 × RS-422\/RS-485 Ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHalf-duplex or Full-duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStart-stop (Asynchronous)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eASCII or Binary formats\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCharacter Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 or 8 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, or Odd\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStop Bits:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 or 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 1200 m (At lower baud rates)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFLR121-S50 optimizes multi-vendor system integration through robust serial engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Port Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo independent ports allow the controller to manage two separate serial networks simultaneously. This architecture permits an engineer to poll high-speed power meters on one port while communicating with legacy sensor arrays on the second.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Distance Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe RS-422\/RS-485 differential signaling supports cable runs up to 1200 meters. This capability eliminates the need for expensive repeaters when interfacing with remote field devices in large-scale plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Protocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting both ASCII and Binary transmission with configurable character lengths and parity, the NFLR121-S50 communicates with a vast range of Modbus-RTU and proprietary serial devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultipoint Network Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles complex multipoint connections effectively. Integrated circuitry manages the transceiver switching for half-duplex RS-485 loops, preventing data collisions and ensuring high network uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Level Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0.3 kg compact design withstands the vibrations found in standard industrial cabinets. The module integrates directly into the FCN baseplate, drawing power from the system bus and reducing external wiring complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use Port 1 for RS-422 and Port 2 for RS-485 simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each port functions independently. You can configure the hardware jumpers and software settings for each port to match the specific requirements of the connected field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFLR121-S50 require external termination resistors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For long-distance RS-485 communication or high baud rates, you must install a 120-ohm termination resistor at the end of the bus to prevent signal reflections. Consult the wiring diagram for specific terminal locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with the FCN-500 controller series?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The \"S50\" suffix represents the current hardware revision designed for the FCN-500 and FCN-RTU architectures within the STARDOM ecosystem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I verify the module's \"Brand New\" condition?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Every NFLR121-S50 arrives in its original factory box with the manufacturer’s seal intact. Each unit includes a unique serial number and a factory inspection certificate to ensure 100% authenticity.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551677641013,"sku":"NFLR121-S50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFAI135-S00_3638a41f-6ef7-49c1-866e-386cc8a9a434.png?v=1775732224"},{"product_id":"nfta4s-00-yokogawa-stardom-pressure-clamp-terminal-block","title":"NFTA4S-00 | Yokogawa STARDOM Pressure Clamp Terminal Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFTA4S-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity interface component within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller ecosystem. This pressure clamp terminal block provides the critical physical connection between field instrumentation and 16-channel analog I\/O modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains optimal signal continuity despite the manufacturer's discontinued status for this specific series.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFTA4S nomenclature defines the mechanical and functional characteristics of the terminal assembly:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFTA4S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: Pressure Clamp Terminal Block for Analog Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic Type: Standard hardware configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo specialized coating or custom options\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFTA4S-00 offers robust termination for high-density analog loops:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSTARDOM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically matches 16-Channel Analog I\/O Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure Clamp (Spring-loaded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel Accessories \/ Wiring Device\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.50 lbs (Approx. 0.23 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFTA4S-00 addresses high-density wiring challenges through specialized mechanical engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Proof Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pressure clamp mechanism maintains constant tension on the field wires. Unlike traditional screw terminals that loosen over time due to machine vibration, this spring-loaded design ensures a gas-tight connection that prevents signal intermittent faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Maintenance and Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTechnicians can detach the entire terminal block from the I\/O module without disconnecting individual field wires. This feature significantly reduces the Mean Time to Repair (MTTR) during module replacements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Marshalling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact footprint allows for high-density packing within marshalling cabinets. This solves the industrial pain point of limited enclosure space in offshore platforms or containerized control rooms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-Free Field Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pressure clamp design accepts standard ferrules and solid wires with minimal tool requirements. This accelerates the commissioning phase and minimizes labor costs during large-scale plant startups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the NFTA4S-00 with digital I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yokogawa designs this specific model for use with 16-channel analog modules. While the physical footprint may look similar to digital versions, the internal pin mapping and voltage ratings specifically support analog signal requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I secure the wires into the pressure clamp?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Insert a small flat-head screwdriver into the actuation slot to open the internal spring. Insert the stripped wire or ferrule, then remove the screwdriver to lock the wire in place. The clamp automatically applies the correct pressure for a secure contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Since the manufacturer has discontinued this model, is this a used part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. We source these from factory-sealed surplus inventory, providing you with unused, factory-standard hardware to maintain your legacy STARDOM systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this terminal block support 2-wire or 4-wire transmitters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The NFTA4S-00 facilitates the wiring for both types; however, you must follow the wiring diagram of the specific 16-channel analog module it attaches to, as the module dictates the power distribution for the loops.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551679050037,"sku":"NFTA4S-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFTB5S-00_77f8309d-a43a-461a-8ced-7e3d786ca3f5.png?v=1775732366"},{"product_id":"nfta4s-10-yokogawa-stardom-pressure-clamp-terminal-block","title":"NFTA4S-10 | Yokogawa STARDOM Pressure Clamp Terminal Block","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFTA4S-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density, spring-loaded interface component for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautonomous controller series. This pressure clamp terminal block facilitates the secure connection between field wiring and 16-channel analog or digital modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring advanced environmental protection to ensure signal integrity in demanding industrial process areas.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFTA4S-10 configuration incorporates specific environmental protection not found in basic models:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDefinition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFTA4S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: Pressure Clamp Terminal Block for 16-Channel Modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvanced Type: Features G3 Conformal Coating for corrosion resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard functional configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFTA4S-10 provides high-integrity termination for process-critical I\/O:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSTARDOM FCN\/FCJ\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure Clamp (Spring-terminal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 16-Channel I\/O Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA Standard G3 Conformal Coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWire Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with standard industrial ferrules and solid\/stranded wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.55 lbs (Approx. 0.25 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFTA4S-10 solves specific environmental and mechanical challenges in the field:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Atmosphere Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"-10\" version includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eISA G3 conformal coating\u003c\/strong\u003e. This protective layer prevents circuit board corrosion caused by harsh gases like hydrogen sulfide (H2S), making it the preferred choice for wastewater treatment, paper mills, and petrochemical refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Free Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pressure clamp mechanism eliminates the risk of \"screw creep.\" Unlike traditional screw terminals that require periodic re-torqueing, the spring-loaded clamp maintains constant pressure, ensuring a gas-tight seal that resists thermal expansion and vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReduced MTTR (Mean Time to Repair):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular design allows technicians to unplug the entire terminal block from the I\/O module without disturbing the field wiring. This permits rapid module replacement during maintenance windows, significantly reducing system downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-Vibration Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe spring-terminal architecture excels in environments with high mechanical vibration (such as near large pumps or compressors). It prevents signal intermittent faults that often plague screw-type connections in heavy industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the NFTA4S-10 differ from the NFTA4S-00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The NFTA4S-10 features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect against corrosive industrial gases, whereas the -00 is the basic type without this extra protection. Both share the same 16-channel pressure clamp functionality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this terminal block with both analog and digital STARDOM modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, as long as the module is a 16-channel version designed for the NFTA4S interface. Always verify the pin-out compatibility in your specific STARDOM hardware manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the pressure clamp require a special tool for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No special tool is necessary. You can actuate the spring-clamp using a standard small flat-head screwdriver to insert the wire. Once you release the spring, it automatically applies the correct clamping force.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this unit shipped in its original packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. We guarantee every NFTA4S-10 arrives as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Yokogawa product, complete with its factory-sealed box and serial number for full traceability.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52551680688437,"sku":"NFTA4S-10","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFTB5S-00_d4cd71a1-a9c6-41a3-b40b-fda0b59d00b1.png?v=1775732492"},{"product_id":"s9981de-02-yokogawa-stardom-network-interface-unit","title":"S9981DE-02 | Yokogawa STARDOM Network Interface Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa S9981DE-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance interface bridge for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSTARDOM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindustrial automation architecture. This module integrates field-level sensors directly into the control network, eliminating communication silos. It processes diverse inputs ranging from thermal data to digital logic, translating raw field signals into actionable data for the controller. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring maximum lifecycle longevity and factory-certified precision for your critical infrastructure.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes specific coding to denote the functional capabilities of the S9981 series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFunctional Significance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS9981\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Series for STARDOM Interface hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDE\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDesignated Digital\/Electronic processing architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-02\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision code indicating specific channel density or firmware version\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe S9981DE-02 features a slim, rack-mountable form factor designed for high-density control cabinets.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eS9981DE-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterface Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e44.5 cm x 13.3 cm x 2.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.9 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermocouples, RTDs, Voltage, Current, and Digital Signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeavy-duty industrial-grade housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe S9981DE-02 addresses specific technical bottlenecks in complex automation environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Signal Normalization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis unit eliminates the need for multiple disparate converters. By accepting RTD, Thermocouple, and Analog signals simultaneously, it simplifies the hardware BOM (Bill of Materials) and reduces cabinet wiring complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Interference (EMI) Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specialized housing design protects internal circuitry from high-frequency noise common in motor control centers. This ensures signal purity and prevents data corruption during transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow-Profile Space Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2.5 cm depth allows for installation in shallow enclosures or high-density racks where standard interface units fail to fit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Capabilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDepending on the STARDOM backplane configuration, this module supports rapid replacement protocols, significantly reducing Mean Time to Repair (MTTR) during maintenance cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the S9981DE-02 require specialized software for configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers configure the S9981DE-02 through the STARDOM Resource Configurator. The module automatically identifies itself to the network upon installation, requiring only specific parameter settings for the connected sensor types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit handle high-vibration environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Yokogawa designs the S9981DE-02 for heavy industrial use. The internal components utilize vibration-resistant mounting techniques to maintain electrical contact integrity even in proximity to heavy rotating machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the unit manage different signal types simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal microprocessor utilizes high-speed multiplexing and individual A\/D converters to isolate and process different signal types. This prevents cross-talk between high-voltage digital signals and sensitive millivolt thermocouple inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit compatible with third-party PLC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe S9981DE-02 primarily serves the Yokogawa STARDOM ecosystem. While it communicates via standard industrial protocols, it delivers the highest efficiency when paired with STARDOM Field Control Stations (FCS).\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52565484634421,"sku":"S9981DE-02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/S9981DE-02.jpg?v=1776131088"},{"product_id":"f3yd64-1p-yokogawa-fa-m3-transistor-output-module","title":"F3YD64-1P  | Yokogawa | FA-M3 Transistor Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3YD64-1P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital output solution for the FA-M3 range-free multi-controller series. This transistor output module manages 64 discrete points, allowing the PLC to drive extensive arrays of external relays, solenoids, and indicators simultaneously. By utilizing advanced photocoupler isolation, the module safeguards internal logic from field-side electrical surges. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring peak switching performance and long-term hardware availability for your automation rack.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P delivers high-density switching capabilities within a compact footprint, optimized for modern control cabinets.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eF3YD64-1P\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransistor Output (Sink\/Source depending on wiring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 Points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Line Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 points per common line\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePhotocoupler isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstanding Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V AC for one minute (external to internal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Load Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.2 to 26.4 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Current Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e275 mA at 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply Requirement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 to 24 V DC (95 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.13 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.89 cm x 8.32 cm x 10 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe F3YD64-1P solves critical spatial and electrical challenges in complex industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Space Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePacking 64 output points into a module less than 3 cm wide significantly reduces the required DIN rail space. This allows engineers to design smaller control cabinets or increase functionality within existing enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1500 V AC photocoupler isolation creates a robust barrier between field wiring and the PLC backplane. This prevents high-voltage transients from damaging the CPU, effectively minimizing system-wide downtime caused by field faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Wiring Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"8 points per common\" architecture balances high-density connectivity with ease of troubleshooting. Technicians can isolate specific groups of outputs for maintenance without disrupting the entire module's operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe low-power transistor design minimizes heat dissipation during high-frequency switching. This stability prevents localized hotspots in the I\/O nest, extending the lifespan of adjacent analog or communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I connect 64 points to such a small module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3YD64-1P utilizes high-density multi-pin connectors. You must use compatible Yokogawa signal cables and terminal blocks to break these points out for field wiring. This approach eliminates the bulk of traditional screw terminals on the module face.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module draws 275 mA from the PLC backplane for internal logic, the output circuits require an external 12 to 24 V DC power source (95 mA) to drive the field loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of photocoupler isolation over mechanical relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhotocouplers offer significantly faster switching speeds and infinite mechanical life. Unlike relays, transistors do not suffer from contact wear or arcing, making the F3YD64-1P ideal for high-cycle applications like pulse-width modulation (PWM) or rapid valve sequencing.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566004859189,"sku":"F3YD64-1P","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3YD64-1P.jpg?v=1776135488"},{"product_id":"nfdv151-p10-yokogawa-stardom-32-channel-digital-input-module","title":"NFDV151-P10 | Yokogawa STARDOM | 32-Channel Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV151-P10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital input interface for the STARDOM autonomous control system. This module captures 32 discrete signals from field devices such as limit switches, pushbuttons, and proximity sensors, translating them into actionable data for the controller. Engineered for Style S2 compatibility, it maintains signal integrity through sophisticated channel isolation. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-original performance even for components no longer in active production by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFDV151-P10 follows Yokogawa's structured coding for the STARDOM hardware platform:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV151\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: Digital Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure clamp terminal connection type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard signal processing speed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAlways \"0\" for this specific model configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStyle S2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenotes the second generation hardware design revision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV151-P10 provides multi-channel monitoring within a compact, lightweight footprint.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSTARDOM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input (DI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.1 mA (per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolated channels for circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Connection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure clamp terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.44 lbs (approx. 0.2 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Style:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStyle S2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV151-P10 addresses complex industrial requirements through specific hardware features:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes opto-isolation techniques to separate field-side electrical noise from the sensitive STARDOM backplane. This prevents high-voltage transients from damaging the CPU and ensures continuous operation in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Channel Layout:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting 32 channels in a single slot, this module reduces the total number of I\/O modules required. This minimizes rack space usage and lowers the overall cost per input point for large-scale automation projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Connections:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pressure clamp terminal design ensures a gas-tight, secure connection. Unlike traditional screw terminals, these clamps resist loosening caused by mechanical vibration, effectively eliminating intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Heat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDrawing only 4.1 mA per channel, the NFDV151-P10 maintains low internal temperatures. This thermal efficiency allows for dense module packing without exceeding the safe operating temperature of the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the NFDV151-P10 replace older Style S1 modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Style S2 modules maintain backward compatibility with STARDOM racks designed for Style S1. However, always verify that your system software revision recognizes the S2 hardware parameters to ensure full diagnostic capability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the benefits of the pressure clamp terminal over standard screw terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePressure clamps significantly accelerate the wiring process during commissioning. They provide consistent tension on the wire, which compensates for thermal expansion and contraction, preventing high-resistance connections over time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle a 24VDC power fluctuation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NFDV151-P10 operates within the standard industrial 24VDC tolerance range. Its internal regulation circuits filter minor ripples, ensuring the digital state (on\/off) remains accurate even if the field power supply experiences minor instability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566073540917,"sku":"NFDV151-P10","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDV151-P10.png?v=1776136752"},{"product_id":"yokogawa-nfdv161-p00-stardom-64-channel-isolated-digital-input-module","title":"Yokogawa NFDV161-P00 STARDOM 64-Channel Isolated Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV161-P00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density interface for large-scale industrial automation, specifically within the STARDOM and DCS ecosystems. This module consolidates 64 discrete digital signals into a single I\/O slot, allowing the central controller to monitor vast arrays of field switches, sensors, and status contacts. By utilizing galvanic isolation across all channels, it prevents field-side electrical surges from reaching the system backplane. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-original specifications and long-term hardware stability for your control architecture.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFDV161 series utilizes a structured suffix system to define connection methods and signal logic:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV161\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64-Channel Isolated Digital Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConnection Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure-clamp terminal block interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard hardware revision and signal threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV161-P00 delivers precision 24V DC signal detection with robust electrical separation.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 isolated discrete channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Thresholds:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eON: 20 to 26.4 V DC | OFF: ≤ 5.0 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.5 mA ± 20% (per channel at rated voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≤ 8 ms (Status input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation (Input-to-System):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV AC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation (Between Commons):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V AC for 1 minute (per 16-channel group)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e550 mA @ 5 V DC (System supply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure-clamp or MIL-connector cable options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV161-P00 addresses critical I\/O density and signal integrity challenges in modern plants:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Cabinet Space Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module processes 64 inputs in the footprint typically occupied by 16 or 32-channel units. This 4x density increase reduces the number of required I\/O racks and minimizes the total cabinet footprint, significantly lowering hardware and enclosure costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Tier Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features 2 kV AC isolation between field inputs and the system bus, plus 500 V AC isolation between 16-channel common groups. This \"staged\" isolation prevents ground loops and ensures that a localized electrical fault does not propagate across all 64 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn 8 ms response time enables real-time monitoring of high-speed process states. For human-machine interfaces, the module utilizes a 20 ms minimum detection time to capture momentary push-button presses accurately, even during high-traffic CPU cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Free Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe pressure-clamp terminal option eliminates the risk of terminal loosening caused by industrial vibration. These connectors maintain constant tension on the field wiring, preventing high-resistance connections and intermittent signal loss over years of continuous operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NFDV161-P00 handle high-voltage spikes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module tolerates instantaneous allowable input voltages up to 30.0 V DC. Beyond this, the 2 kV AC galvanic isolation protects the central controller by physically decoupling the field wiring from the internal system logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the 16-channel common groups?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 64 channels are divided into four 16-channel groups, each with its own isolated common. This architecture allows you to mix different power sources or signal segments within the same module while preventing electrical cross-talk between the groups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for high-frequency pulse counting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile optimized for status monitoring, the module supports a maximum ON\/OFF cycle of 25 Hz for push-button inputs. For applications requiring kilohertz-range counting, we recommend a dedicated high-speed counter module rather than a standard digital input.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566102606133,"sku":"NFDV161-P00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDV151-P102__2_a0e81556-56ae-4c35-a6a6-21f1971e138a.png?v=1776136921"},{"product_id":"yokogawa-nfdv161-p50-stardom-64-channel-isolated-digital-input-module","title":"Yokogawa NFDV161-P50 STARDOM 64-Channel Isolated Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV161-P50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized, ultra-high-density digital input module within the STARDOM autonomous control ecosystem. This module monitors 64 fully isolated discrete channels, making it a cornerstone for large-scale industrial deployments utilizing FCN-500, FCN-RTU, and FCJ controllers. Unlike standard input modules, the P50 variant features hardware-level pushbutton edge detection, allowing the system to capture momentary trigger events with extreme precision. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, ensuring factory-original reliability for critical infrastructure and process control.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFDV161 series utilizes suffix codes to define specific functional capabilities and connection interfaces:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV161\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64-Channel Isolated Digital Input Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInterface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePressure clamp terminal or MIL-connector compatible\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFunctionality\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePushbutton edge detection enabled\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral-purpose industrial type\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV161-P50 delivers robust signal processing across a wide thermal range, optimized for 24V DC logic.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 (fully isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 to 26.4 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput OFF Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 5.0 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.5 mA ±20% per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV AC (Input to System); 500 V AC (Between 16-channel commons)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Response Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 8 ms (Status input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum ON Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 ms (Pushbutton input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Current Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e550 mA @ 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV161-P50 addresses the rigorous demands of modern plant automation through several engineering innovations:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Edge Detection Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"-P50\" hardware enables edge detection for pushbutton inputs. This eliminates the risk of missing momentary contact closures that standard polling cycles might overlook, ensuring the controller captures every operator intervention or pulse signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Integrity via Multi-Stage Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 2 kV AC galvanic isolation from the system bus and 500 V AC isolation between each 16-channel common group. This architecture prevents ground loops and ensures that an electrical fault in one field segment does not propagate to the rest of the I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMassive Footprint Reduction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcessing 64 channels in a single slot drastically reduces the required number of I\/O nests and cabinets. This 0.3 kg module optimizes space in crowded offshore platforms or compact RTU enclosures, lowering overall installation costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Field Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports both MIL-connector cables for rapid pre-fab wiring and pressure clamp terminals for secure, vibration-resistant field connections. The pressure clamps accommodate wire gauges from AWG 20 to 14, providing mechanical stability in high-vibration environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the NFDV161-P50 differ from the P00 version?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NFDV161-P50 includes specialized circuitry for pushbutton edge detection. While the P00 version handles general status inputs, the P50 variant ensures the system captures rapid \"ON\" pulses (minimum 20 ms) specifically required for manual override buttons and pulse-type field sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the 500 V AC isolation between commons?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 64 channels occupy four groups of 16. The 500 V AC isolation between these groups allows you to utilize different 24V DC power sources for different sections of the module without risking cross-talk or circulating currents between the commons.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module operate in extreme outdoor environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. With an operating temperature range of -20°C to +60°C and a non-condensing humidity tolerance up to 95%, the NFDV161-P50 excels in field-mounted RTU cabinets and harsh industrial settings where temperature fluctuations are common.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabling is required for the MIL-connector option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor high-density wiring, we recommend using Yokogawa-standard MIL-connector cables that break out into terminal boards. This setup simplifies troubleshooting and significantly reduces the time required for loop checks during commissioning.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566111650101,"sku":"NFDV161-P50","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDV161-P50.png?v=1776137540"},{"product_id":"nfdv551-p10-yokogawa-stardom-32-channel-digital-output-module","title":"NFDV551-P10 | Yokogawa STARDOM 32-Channel Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV551-P10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital output interface for the STARDOM autonomous control system, including FCN-500 and FCN-RTU controllers. This module manages 32 isolated sink-type channels, driving field devices such as solenoids, relays, and indicators with precision. Designed for harsh industrial environments, the P10 variant features ISA G3 compliance for corrosion resistance and an integrated status display for real-time monitoring. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring factory-certified reliability for your critical process control sequences.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFDV551 series utilizes specific suffix codes to define hardware robustness and interface features:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Significance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV551\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 32-Channel Digital Output Module (Sink Type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Interface for MIL-connector or pressure clamp terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDenotes integrated status display functionality\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eISA G3 Compliant\u003c\/strong\u003e for corrosive gas environments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV551-P10 provides rapid switching capabilities and robust electrical separation.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 (Sink type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Output Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.4 to 26.4 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Load Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 mA per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 3 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV AC (Signal to System); 500 V AC (Between 16-channel groups)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFallback Modes:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHOLD, OFF, or NO (User-configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e700 mA @ 5 V DC (System); 60 mA @ 24 V DC (Field)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Standard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eISA G3 compliant (Corrosion resistance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV551-P10 addresses specific industrial challenges through advanced hardware engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Protection in Harsh Atmospheres:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ISA G3 compliance ensures the module survives in environments with elevated levels of hydrogen sulfide, chlorine, or other corrosive gases. This protects the internal circuitry from premature failure in refineries and chemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Switching Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA response time of less than 3 ms enables high-speed logic execution. This allows the controller to manage fast-acting solenoids and pulse-type equipment without introducing significant process lag.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Safety Fallback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features programmable fallback states (HOLD\/OFF\/NO). In the event of a communication loss between the CPU and the I\/O rack, the module automatically forces outputs to a pre-defined safe state, preventing hazardous process conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSegmented Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy providing 500 V AC isolation between each 16-channel group, the module prevents a localized ground fault from affecting the entire 32-channel block. This architecture simplifies troubleshooting and improves overall system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between a \"Sink Type\" and \"Source Type\" output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NFDV551-P10 is a sink-type module, meaning the module provides the ground path (negative) for the load. You must connect the positive side of your field device to the external 24 V DC power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different voltages across the 32 channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module operates on a 24 V DC rated system. While you have isolation between 16-channel groups, we recommend maintaining a consistent voltage across the entire module to ensure compliance with the rated operating range of 20.4 to 26.4 V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the -P10 suffix affect the installation method?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The -P10 refers to the standard type with a status display and G3 coating. It supports both MIL-connector cables for rapid cabinet wiring and pressure clamp terminals for traditional field-side termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the HOLD fallback mode function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf the controller loses communication with the NFDV551-P10, the \"HOLD\" setting maintains the last commanded state of each output. This is useful for processes where a sudden \"OFF\" state would cause mechanical stress or safety risks.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566147957045,"sku":"NFDV551-P10","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDV161-P50_f328d3ba-79fe-4b78-b7e0-50ffc47e9406.png?v=1776137755"},{"product_id":"nfdv561-p00-stardom-64-channel-digital-output-module-yokogawa","title":"NFDV561-P00 STARDOM 64-Channel Digital Output Module | Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV561-P00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density digital output solution within the STARDOM autonomous control system architecture. This module enables the central controller to drive up to 64 discrete field devices, such as solenoid valves, actuators, and signal lamps, from a single I\/O slot. By consolidating a high volume of output points, it optimizes rack space and simplifies complex wiring architectures in large-scale process automation. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring factory-certified performance and long-term durability for your control network.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes a standardized suffix system to identify connection styles and functional revisions for the NFDV series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Definition\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV561\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 64-Channel Digital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard interface for MIL-connector or pressure-clamp terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard hardware revision with sink-type output logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV561-P00 offers a lightweight yet robust design capable of managing dense I\/O loads.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYOKOGAWA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e64 Points (Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSink Type (Transistor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Load Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.4 to 26.4 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePhotocoupler isolation between internal logic and field signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 500 mA @ 5 V DC (Internal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV561-P00 addresses critical infrastructure needs through superior high-density engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnmatched Rack Space Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy packing 64 output channels into a slim 2.2 cm width, this module eliminates the need for multiple I\/O nests. This allows engineers to significantly reduce cabinet footprints or add extensive functionality to existing control rooms without physical expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated photocouplers physically separate the field-side electrical circuits from the sensitive internal system bus. This barrier prevents electrical surges, ground loops, and high-voltage transients from damaging the CPU, ensuring continuous operation in harsh industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe solid-state transistor outputs provide near-instantaneous response times compared to mechanical relays. This speed allows for precise timing in batch processes and high-frequency valve pulsing without the mechanical wear associated with traditional contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Termination Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports both MIL-connector cables for rapid pre-fabricated wiring and pressure-clamp terminals for secure field connections. The lightweight 0.1 kg build reduces mechanical stress on the backplane, even in high-vibration environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many field devices can I control with a single NFDV561-P00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module supports 64 independent digital output channels. You can control 64 separate 24V DC devices, provided the total current load remains within the specified limits for each 16-channel common group.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of a \"Sink Type\" output for my system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSink type (NPN) outputs simplify wiring when using a common positive power supply for your field devices. The module acts as the switch to the ground (negative), which is a standard configuration for many industrial solenoids and PLC-compatible relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the NFDV561-P00 to replace older 32-channel modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the NFDV561-P00 offers higher density, you must verify that your STARDOM system software and I\/O rack backplane support the 64-channel configuration. You will also need to update your wiring plan to accommodate the high-density MIL-connector or pressure-clamp interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external 24V DC power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module draws its logic power from the system bus, the transistor outputs require an external 24V DC field power source to drive the connected loads (actuators, relays, etc.).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566167617845,"sku":"NFDV561-P00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFDV561-P00.png?v=1776138016"},{"product_id":"yokogawa-nflr121-s00-stardom-rs-422-rs-485-serial-communication-module","title":"Yokogawa NFLR121-S00 STARDOM RS-422\/RS-485 Serial Communication Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFLR121-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-speed serial communication interface for FCN (Field Control Node) autonomous controllers. This module enables the STARDOM system to integrate with diverse third-party industrial hardware, including motor drives, power meters, and specialized analytical instruments. By supporting both RS-422 and RS-485 protocols, the NFLR121-S00 facilitates robust, multi-drop data exchange over long distances. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring factory-certified data integrity for your critical process control network.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes the following nomenclature for the NFLR121 series to specify communication standards and hardware revisions:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFLR121\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: Serial Communication Module (FCN compatible)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interface: RS-422\/RS-485 standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e00\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard hardware revision for universal industrial applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFLR121-S00 delivers high-bandwidth serial transmission with integrated electrical protection.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-422 \/ RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transfer Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 1.85 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransmission Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 1200 meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransformer isolation (Internal logic to field)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCharacter Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 or 8 bits (Configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParity Check:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNone, Even, or Odd\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eD-sub 9-pin (female) or Terminal block with M4 screw clamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFLR121-S00 solves complex integration challenges in distributed automation environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Long-Distance Link:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile standard serial links often struggle with speed over distance, this module maintains rates up to 1.85 Mbps. It extends your control network reach up to 1200 meters, allowing the FCN controller to manage remote field devices without signal repeaters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer-Based Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated transformer isolation physically decouples the communication line from the FCN backplane. This prevents ground loops and protects the central processor from high-voltage surges or electrical noise common in industrial motor control centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Physical Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports two distinct connection methods. The D-sub 9-pin connector allows for rapid plug-and-play integration with standard devices, while the M4 screw clamp terminal block provides a vibration-proof, high-torque connection for permanent field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Protocol Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThrough software settings, engineers define parity, stop bits, and character lengths. This flexibility ensures the NFLR121-S00 communicates seamlessly with legacy proprietary devices and modern Modbus-compatible hardware alike.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between RS-422 and RS-485 modes on the NFLR121-S00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module determines the communication mode based on your wiring configuration and software parameters within the STARDOM configuration tool. Ensure your cable termination matches the 4-wire (RS-422) or 2-wire (RS-485) requirements of your field device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external termination resistors for RS-485?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. For long-distance transmissions or high-speed links near 1.85 Mbps, you must install appropriate termination resistors (typically 120 ohms) at both ends of the segment. This prevents signal reflections that cause data corruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the NFLR121-S00 support multi-drop networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. In RS-485 mode, the module manages multi-drop configurations, allowing a single FCN controller to communicate with multiple slave devices on a single twisted-pair cable, significantly reducing wiring costs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of transformer isolation over optical isolation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTransformer isolation provides superior common-mode rejection and handles higher voltage transients more effectively in RS-422\/485 environments. This ensures the communication link remains stable even in the presence of heavy electromagnetic interference.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566180626741,"sku":"NFLR121-S00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFLR121-S00.png?v=1776138625"},{"product_id":"yokogawa-nftr85-10-high-density-32-ch-digital-input-module","title":"Yokogawa NFTR85-10 High-Density 32-Ch Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFTR85-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a vital high-density digital input interface within industrial automation platforms. This module monitors 32 discrete channels, translating signals from field devices into actionable data for the central control system. Engineered for high-speed signal acquisition, the NFTR85-10 facilitates real-time monitoring of process states in complex manufacturing environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring factory-certified performance and seamless integration into your existing Yokogawa architecture.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eYokogawa utilizes specific coding to define the functional capabilities of the NFTR series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Significance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFTR85\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: High-Density Digital Input Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-10\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard hardware revision for general-purpose industrial monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFTR85-10 features a robust construction optimized for consistent operation within industrial control cabinets.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNFTR85-10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReal-time monitoring of discrete field signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density, compact, and robust industrial build\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa automation and control platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eJapan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFTR85-10 addresses common industrial infrastructure challenges through precise hardware engineering:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Space Utilization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe high-density 32-channel layout allows for extensive I\/O expansion without increasing the physical footprint of the control rack. This compact design enables engineers to deploy complex monitoring systems within restricted cabinet spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Industrial Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa builds the NFTR85-10 with a robust chassis that withstands the thermal and mechanical stresses of factory floors. This durable design maintains signal integrity even in environments subject to constant low-frequency vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless System Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module interfaces natively with Yokogawa automation platforms, eliminating the need for complex third-party signal converters. This native compatibility ensures deterministic data throughput and simplifies the system configuration process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Signal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry processes multiple digital inputs simultaneously. This ensures the controller receives status changes from limit switches, pushbuttons, and sensors with minimal latency, which is critical for safety-related monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many field devices can I connect to the NFTR85-10?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports up to 32 independent digital input channels. This allows you to monitor 32 separate discrete field devices, such as pressure switches, motor status contacts, or proximity sensors, through a single module slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the NFTR85-10 compatible with older Yokogawa racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe NFTR85-10 maintains compatibility with standard Yokogawa automation hardware. However, we recommend verifying your specific backplane and system software version to ensure full driver support and optimal communication speeds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary applications for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEngineers typically deploy the NFTR85-10 in industrial process monitoring, factory automation, and environmental control systems. It excels in applications requiring high-density status tracking where reliability and signal speed are paramount.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566220144949,"sku":"NFTR85-10","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFTB5S-00_c423cb32-a135-4535-8185-62865d3695fe.png?v=1776138816"},{"product_id":"yokogawa-nfdv551-p60-stardom-32-channel-digital-output-module","title":"Yokogawa NFDV551-P60 STARDOM 32-Channel Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa NFDV551-P60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital output interface for the STARDOM autonomous control system. This module manages 32 isolated 24V DC channels, allowing the controller to drive field actuators, solenoid valves, and motor starters with high precision. Featuring an integrated status display, the P60 variant provides immediate visual feedback for each output state, simplifying local troubleshooting. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, ensuring factory-original performance and long-term hardware availability for your I\/O infrastructure.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe NFDV551-P60 utilizes Yokogawa's structured suffix logic to define connection types and protective features:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode Segment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Significance\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNFDV551\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model: 32-Channel Digital Output Module (24V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-P\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard interface supporting Pressure Clamp Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e6\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIncludes Status Display; No explosion protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic type hardware configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe NFDV551-P60 delivers robust switching capabilities with complete electrical separation from the system bus.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNFDV551-P60\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 (Isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Output Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard Digital Output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicator:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel LED status display per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePressure Clamp Terminal Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Level:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGeneral purpose (No explosion protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Style:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBasic Type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe NFDV551-P60 addresses the rigorous demands of modern control cabinets through superior design:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstant Visual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated status display allows maintenance personnel to verify output states at a glance. This local visibility drastically reduces the time required to identify loop failures or controller logic discrepancies without opening an engineering workstation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-integrity isolation barriers protect the STARDOM backplane from field-side electrical transients. This architecture prevents a localized short circuit in a field solenoid from damaging the central processor, maintaining overall system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Resistant Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports pressure clamp terminals, which maintain constant pressure on the field wiring. This design eliminates the risk of terminal loosening caused by thermal cycling or industrial vibration, ensuring a stable electrical path over years of service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified High-Density Wiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy consolidating 32 channels into a single module, the NFDV551-P60 minimizes the physical footprint required in the I\/O nest. This density allows for more compact control cabinets and reduces the total hardware cost per output point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the NFDV551-P60 support MIL-connector cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe P60 suffix specifically supports pressure clamp terminal connections for direct field wiring. If your system requires MIL-connector cable integration for rapid pre-fab wiring, please consult our technical team for the appropriate connector-type variant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the \"Basic Type\" designation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Basic Type\" (Suffix 0) refers to the standard functional configuration optimized for general-purpose industrial switching. It provides the core digital output performance required for most process automation tasks without the added complexity of specialized edge-detection or high-frequency pulse circuitry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this module in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The \"6\" suffix indicates that the unit provides no explosion protection. You must install the NFDV551-P60 in a non-hazardous, safe area or within a suitably certified purged enclosure if deployment near volatile environments is necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the isolation protect my controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module utilizes opto-couplers to physically separate the 24V DC field-side power from the 5V DC system-side logic. This prevents ground loops and blocks high-voltage surges from entering the FCN\/FCJ controller through the I\/O backplane.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566229582133,"sku":"NFTC5S-00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NFAI135-S00_4549a2f7-23a9-43e7-98c4-44a1ea96270b.png?v=1776138992"},{"product_id":"yokogawa-ec402-51-control-system-bus-coupler-module","title":"Yokogawa EC402-51 Control System Bus Coupler Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa EC402-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance Bus Coupler Module within Yokogawa’s industrial control architecture. This module facilitates critical data bridges between the central processing unit (CPU) and distributed I\/O nests, ensuring seamless, bidirectional communication. By managing high-speed synchronization across the network, the EC402-51 maintains the deterministic performance required for complex process automation. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original, guaranteeing factory-sealed integrity for your system expansion or maintenance needs.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe EC402-51 utilizes specialized circuitry to maintain stable data throughput across the system backplane.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEC402-51\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBus Coupler \/ Communication Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Exchange:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReal-time, bidirectional\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed proprietary industrial bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–20°C to 70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% RH (Non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModular rack-mount installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LED status indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe EC402-51 solves complex networking and environmental challenges in large-scale industrial plants:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Latency Jitter:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module hardware prioritizes real-time data packets, ensuring that I\/O signals reach the controller without the unpredictable delays common in standard networking hardware. This deterministic behavior allows for tighter control loop tuning in high-speed processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced EMI Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa engineers the EC402-51 with high noise immunity to withstand the intense electromagnetic interference found in power plants and heavy manufacturing zones. This prevents data corruption or communication drops when installed near high-voltage switchgear or large motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Fault Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LED indicators provide immediate visual feedback on communication health and module status. This allows maintenance teams to identify and resolve bus-level issues instantly, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable System Expansion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular rack-mount design enables engineers to add I\/O subsystems with minimal configuration overhead. The EC402-51 manages the increased bus load efficiently, allowing the control system to grow alongside your production requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat primary role does the EC402-51 play in a Yokogawa system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt acts as the essential interface between the controller and the I\/O racks. It converts and routes signals across the high-speed bus, ensuring that every connected I\/O module stays synchronized with the central control logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle electrical noise in a factory setting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe EC402-51 features a robust industrial design that adheres to strict EMI resistance standards. It utilizes filtered power inputs and shielded communication paths to maintain signal integrity even in environments with heavy electrical interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the EC402-51 require manual software addressing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module typically integrates into the Yokogawa control platform via standard hardware configuration tools. Once installed in the modular rack, the system recognizes the coupler and establishes the communication link based on the rack's physical slot and bus topology.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an existing bus coupler with the EC402-51?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your current system utilizes the EC402 series, the -51 revision provides a direct, high-performance replacement. Always verify your specific system firmware and rack compatibility before installation to ensure a seamless hardware transition.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566817767733,"sku":"SSC50D-F2524","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/EC402-51.png?v=1776149094"},{"product_id":"yokogawa-accc01-cable-connector-cover-for-control-module","title":"Yokogawa ACCC01 Cable Connector Cover for Control Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ACCC01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a specialized Cable Connector Cover designed to shield and secure the electrical interfaces of Yokogawa control modules. This protective component acts as a physical barrier against environmental contaminants, such as dust, moisture, and airborne particles, which can compromise signal integrity over time. Furthermore, the ACCC01 provides essential strain relief and mechanical support for connected field wiring, preventing accidental disconnections in high-vibration industrial settings. We offer this accessory as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original to ensure a precise fit and maximum protection for your DCS hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe ACCC01 utilizes high-grade industrial materials to maintain structural integrity in demanding plant conditions.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYokogawa Electric Corporation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eACCC01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCable Connector Cover \/ Terminal Shield\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlame-retardant, high-impact industrial polymer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecific Yokogawa I\/O and communication modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAttachment Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure snap-on or screw-mount (hardware dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecision-molded to match standard module profiles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 0.05 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New and Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe ACCC01 addresses critical maintenance and safety challenges within industrial control cabinets:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrevention of Signal Interference:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy sealing the gap between the cable and the module interface, the ACCC01 prevents the accumulation of conductive dust and metallic debris. This eliminates the risk of short circuits and intermittent signal \"jitter\" caused by particulate ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Cable Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cover secures the cable assembly firmly against the module body. This mechanical reinforcement prevents wires from pulling loose due to routine maintenance activities or the constant low-frequency vibrations typical of power plants and refineries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImproved Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe design allows for sufficient airflow around the connector while blocking direct heat radiation from adjacent high-power modules. This helps maintain stable operating temperatures at the connection point, reducing the risk of terminal oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProfessional Cabinet Organization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the ACCC01 results in a cleaner, more organized wiring architecture. It conceals exposed terminal pins and wire ferrules, providing a streamlined appearance that facilitates easier visual inspections and adheres to strict industrial safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ACCC01 compatible with all Yokogawa modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ACCC01 fits specific series of Yokogawa I\/O and communication modules. You should verify your specific module's model number against the compatibility list to ensure the connector spacing and mounting points align correctly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cover interfere with diagnostic LED visibility?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Yokogawa engineers the ACCC01 with precision cutouts or transparent sections that allow technicians to view status indicators and diagnostic LEDs without removing the protective cover.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this cover assist with EMI\/RFI protection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the cover is primarily a mechanical and environmental shield, its robust polymer construction helps maintain the intended shielding path of the cable. By securing the cable in its optimal position, it ensures that shielded ferrules maintain proper contact with the module's grounding points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the ACCC01 without disconnecting the existing wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn most configurations, the ACCC01 features a \"clamshell\" or \"slide-on\" design that allows for installation over existing connections. This enables you to upgrade your terminal protection without interrupting the process or performing a full system shutdown.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52566877864245,"sku":"ACCC01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ADV151-P03_417390f0-10a1-450c-a61e-e4c5bf789c23.png?v=1776149397"},{"product_id":"yokogawa-f3xd32-3f-fa-m3-dc-input-module","title":"Yokogawa F3XD32-3F FA-M3 DC Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3XD32-3F\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital interface for the FA-M3 multi-controller series. This DC input module facilitates the connection of up to 32 field devices, such as limit switches, sensors, and pushbuttons, directly to the PLC processor. Although the manufacturer has officially discontinued this series, we supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efactory stock. This ensures you maintain your existing machine control infrastructure without the need for expensive system migrations or software overhauls.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Input (Digital)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSink and Source (Bidirectional)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFA-M3 \/ Yushin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC Module \/ Machine Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 lbs (Approx. 0.25 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Logic Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 32-point architecture allows for significant I\/O expansion while occupying only a single slot on the FA-M3 backplane. This footprint optimization frees up rail space for additional communication or motion control modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Wiring Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3XD32-3F supports both Sink and Source wiring configurations. This versatility enables engineers to integrate various sensor types (NPN\/PNP) using the same hardware, simplifying spare parts inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response Scanning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module's internal circuitry filters input noise and debounces signals at high speeds. This ensures that the CPU receives clean, accurate data from field sensors even in high-speed manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstalling a brand new F3XD32-3F restores the reliability of aging machine control racks. By replacing worn components with original new stock, you prevent intermittent signal failures and extend the operational life of your facility's legacy automation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle different sensor polarities?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3XD32-3F features a flexible input circuit. By changing the common line (COM) wiring on the external terminal block, you switch the module between sink (NPN) and source (PNP) operation to match your field device requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between this and the 16-point versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3XD32-3F doubles the input capacity in the same physical module size. This requires a high-density connector (typically a 40-pin MIL type) rather than standard screw terminals, requiring appropriate pre-assembled cables or custom wiring looms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit a \"used\" part since it is discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. It originates from surplus factory-sealed inventory. It has never seen service and undergoes rigorous QC checks to ensure it meets original Yokogawa performance specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an F3XD32-3N with this 3F model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"3F\" suffix typically denotes specific hardware revisions or connector styles (like a FCN or MIL connector). Always verify your existing cable termination type before replacement to ensure the physical connector matches your current wiring harness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777360949557,"sku":"AEP7D-25","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3XD32-3F.png?v=1776915378"},{"product_id":"f3yd32-1p-fa-m3-yokogawa-transistor-output-module","title":"F3YD32-1P FA-M3 | Yokogawa | Transistor Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3YD32-1P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density Transistor Output Module for the FA-M3 multi-controller series. This module manages 32 digital output points, providing reliable switching for solenoids, relays, and other 12-24 VDC industrial loads. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-speed operation and stable signal switching for your automated machine control tasks.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF3YD32\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-Point Transistor Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard transistor output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecific hardware revision level\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommon Line Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 points per common\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotocoupler isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 V DC (Operating: 10.2 to 26.4 V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V AC for one minute (Terminal to Internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 mA (5 V DC internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.89 cm x 8.32 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module employs photocoupler isolation for every output channel. This prevents high-voltage spikes from the field devices (such as inductive solenoid kicks) from propagating back to the CPU backplane, protecting your controller's core processors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Common Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 8-point\/common architecture allows engineers to group outputs based on power source or voltage levels. This flexibility simplifies wiring in cabinets where mixed-voltage control loops coexist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 2.89 cm wide housing optimizes backplane slot density. It enables high-volume output deployment in standard FA-M3 racks, making it ideal for cabinets with limited space for bulky wiring harnesses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1500 V AC withstanding voltage rating ensures structural integrity against surge transients, maintaining consistent output states even in high-EMI environments like injection molding or automated welding stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply for the field side?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the module draws internal power from the backplane (160 mA), you must provide an external 12 to 24 V DC power source (95 mA requirement) to drive the output loads connected to the terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix 12V and 24V loads on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, provided you respect the 8-point\/common groupings. You can power one common group (8 points) with 12V and another group with 24V, allowing for mixed-voltage control on a single F3YD32-1P module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the output signal \"sink\" or \"source\" type?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3YD32-1P operates as a standard transistor output module. Verify your specific wiring diagram for the \"1P\" variant, as this model typically accommodates specific sinking or sourcing configurations depending on the common connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions are necessary during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways disconnect the external field power supply before performing any wiring changes. Use proper crimping tools for the terminal connectors to prevent loose contacts, which often lead to arcing or intermittent output states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777412788533,"sku":"F3YD32-1P","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3YD32-1P.png?v=1776915641"},{"product_id":"yokogawa-f3le11-1t-fa-m3-ethernet-communication-interface-module","title":"Yokogawa F3LE11-1T FA-M3 Ethernet Communication Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3LE11-1T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary gateway for connecting FA-M3 series PLCs to high-speed Ethernet networks. This module facilitates seamless data exchange between the controller and supervisory systems, supporting both 10BASE-T and 100BASE-TX standards. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automation architecture utilizes the latest factory-standard hardware for remote monitoring and industrial data logging.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Standards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEEE 802.3 Compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Mbps (10BASE-T) \/ 100 Mbps (100BASE-TX)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Stack\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTCP\/IP, SMTP, POP3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Segment Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccess Control\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSMA\/CD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330 mA maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.9 (W) × 100 (H) × 83.2 (D) mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Diagnostic Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3LE11-1T integrates SMTP and POP3 protocols, allowing the PLC to send automated email alerts regarding system status or alarm triggers. This functionality eliminates the need for constant manual oversight and speeds up response times for maintenance teams.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Speed Auto-Negotiation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports 10\/100 Mbps speeds, allowing it to interface with both legacy industrial hubs and modern high-speed switches. This versatility ensures stable performance regardless of the existing network infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Rack Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a width of only 28.9 mm and a weight of 100g, this module maintains a low physical footprint. It slides easily into standard FA-M3 PLC racks, preserving valuable slot space for additional I\/O or motion control modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Baseband Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware utilizes baseband transmission and CSMA\/CD access control to minimize data collisions. This ensures deterministic communication paths required for real-time remote monitoring and synchronized data logging systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support fiber optic connections?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the F3LE11-1T utilizes standard RJ-45 connectors for twisted-pair copper cabling. To transition to fiber, you must use an external media converter or an alternative Yokogawa fiber-specific interface module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the email notification feature?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou configure the SMTP server settings and recipient addresses within the FA-M3 programming environment. The module then triggers emails based on specific ladder logic conditions or register values defined by the user.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the F3LE11-1T compatible with all FA-M3 CPU types?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3LE11-1T works with most standard FA-M3 CPU modules. However, always verify that your specific CPU firmware version supports Ethernet communication functions to ensure full protocol transparency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of segments allowed in a cascade setup?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports up to 2 segments or up to 4 segments depending on your specific network topology and the type of switching equipment used. For maximum stability over 100 meters, we recommend using active industrial switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777440084277,"sku":"F3LE11-1T","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3LE11-1T.png?v=1776916219"},{"product_id":"f3cu04-1s-fa-m3-temperature-pid-control-module-yokogawa","title":"F3CU04-1S FA-M3 Temperature PID Control Module | Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3CU04-1S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Temperature PID Control module for the FA-M3 controller series. This module automates thermal regulation for critical industrial processes, maintaining setpoints through advanced PID logic. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring precise thermal response and stable alarm monitoring for your factory automation line.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF3CU04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature PID Control Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard PID hardware configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware revision level\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 outputs per loop (2 relays per loop)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eON-delay timing included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarm-up Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 minutes minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Ambient Change Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10°C\/h maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e470 mA (5 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 18-point terminal blocks (M3.5 screws)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Alarm Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3CU04-1S provides 4 alarm outputs per control loop. This granular alarm structure allows engineers to configure primary and secondary safety triggers (e.g., Warning and Shutdown) without requiring external relay logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Thermal Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features an \"Alarm ON-delay\" function. This capability filters out transient temperature spikes, preventing nuisance alarms in processes where minor, non-critical fluctuations occur during normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes two 18-point terminal blocks with M3.5 screws. This connection method ensures a high-torque mechanical grip on field wiring, preventing loose connections that often trigger signal drift in precision thermal applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for stable operation, the F3CU04-1S handles ambient temperature changes up to 10°C\/h without degrading PID control accuracy. This robustness keeps process variables steady, even in plant environments experiencing significant seasonal or daily temperature swings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"30-minute warm-up\" specification mean for my process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 30 minutes to stabilize its internal reference voltage and thermal sensor circuitry. Ensure you power on the module at least 30 minutes before enabling the active PID control loops to guarantee maximum accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older F3CU04 revision with the -1S model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3CU04-1S maintains backward compatibility with standard FA-M3 base units. However, always review your existing control program logic, as updated hardware revisions occasionally include minor register mapping changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the two input relays for alarms 1 and 2 operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach control loop provides two specific alarm inputs. You define these in the software to trigger based on deviation, absolute value, or rate-of-change, providing flexible safety interlocks for your specific thermal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the F3CU04-1S susceptible to interference from nearby motor controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa designs the F3CU04-1S with internal signal isolation. However, for maximum precision, route your temperature sensor leads (thermocouple or RTD) away from high-power cabling or AC motor drives to minimize electromagnetic noise pickup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777480323381,"sku":"F3CU04-1S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3CU04-1S.png?v=1776916486"},{"product_id":"yokogawa-f3ad0b-4w-fa-m3-analog-input-module","title":"Yokogawa F3AD0B-4W FA-M3 Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3AD0B-4W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision analog data acquisition interface for the FA-M3 range-free multi-controller. This module captures critical process variables from field transmitters and converts them into 16-bit digital values for the PLC processor. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring maximum signal integrity and system longevity for your automation infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Analog Input Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit A\/D Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal (Current)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 to 20 mA DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal (Voltage)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 to 5 V DC, \u003cspan class=\"math-inline\"\u003e$\\pm 10$\u003c\/span\u003e V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 0.1\\%$\u003c\/span\u003e of span\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Channel-to-ground\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan class=\"math-inline\"\u003e$\\leq 100$\u003c\/span\u003e ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 to 4 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 × 25 × 90 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3AD0B-4W features independent channel-to-channel isolation. This hardware architecture prevents ground loops and eliminates cross-talk between different field sensors, a critical requirement in facilities with heavy electrical equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Signal Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers configure each channel independently to accept current or voltage signals. This flexibility allows the F3AD0B-4W to interface with varied instrumentation, such as flow meters (4-20mA) and pressure transducers (±10V), on a single module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Fidelity Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution provides the granularity needed for sensitive chemical and pharmaceutical processes. This high bit-depth ensures the PLC detects even minute fluctuations in process variables, enabling tighter control loop performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Self-Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in fault detection logic continuously monitors the health of the A\/D converter and input circuitry. The module immediately reports hardware irregularities to the FA-M3 CPU, reducing mean time to repair (MTTR) during maintenance cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F3AD0B-4W require external power for the A\/D conversion?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module draws its operating power directly from the FA-M3 backplane. However, you must provide separate power to your field transmitters if they operate on a 2-wire current loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between voltage and current modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou select the input range and signal type through the PLC configuration software. Additionally, ensure you follow the terminal wiring diagram specific to current or voltage to avoid damaging the internal precision resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module replace older 12-bit analog input cards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3AD0B-4W fits standard FA-M3 base units and serves as a significant upgrade over lower-resolution modules. While the physical installation is compatible, you must update the scaling parameters in your ladder logic to account for the higher 16-bit resolution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should I take for the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 10$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eV DC input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways use shielded twisted-pair (STP) cabling for voltage signals. Ground the shield at a single point, preferably at the PLC rack side, to minimize electromagnetic interference (EMI) that could skew the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm 0.1\\%$\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eaccuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777493365045,"sku":"F3AD0B-4W","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3XD32-3F_8ef550fb-fdf7-49c0-a0d9-f432a735aa08.png?v=1776916688"},{"product_id":"yokogawa-f3da04-6r-fa-m3-high-resolution-analog-i-o-module","title":"Yokogawa F3DA04-6R FA-M3 High-Resolution Analog I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3DA04-6R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance analog interface for the FA-M3 multi-controller series. This module integrates high-resolution 16-bit Analog-to-Digital conversion to manage critical process variables with extreme precision. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the ultra-fast sampling speeds required for advanced machine control and high-speed data acquisition.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Bit High-Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 \u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 VDC, -10 to 10 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 20 mA, 4 to 20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePC Board PLC \/ Add-On Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3DA04-6R executes sampling at a rate of 50\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es per point. This speed allows the PLC to capture transient signal spikes and rapid process fluctuations that standard analog modules typically miss, making it ideal for high-speed pressure monitoring or motion feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior 16-Bit Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit ADC architecture provides 65,536 levels of quantization. This high granularity ensures the control system detects minute changes in sensor data, which directly improves the accuracy of PID loops and delicate chemical dosing processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Signal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module accepts multiple signal types, including bipolar voltage (-10 to 10 VDC) and standard process currents (4 to 20 mA). Engineers configure these ranges to match various field instruments without requiring external signal conditioners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"6R\" revision incorporates advanced filtering circuitry to mitigate electromagnetic interference (EMI). This hardware-level protection prevents data corruption in harsh plant environments where high-frequency noise from VFDs or heavy machinery often distorts sensitive analog signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F3DA04-6R require a specific base unit for installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3DA04-6R fits standard FA-M3 I\/O slots. However, to utilize the 50\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\mu$\u003c\/span\u003es sampling speed effectively, ensure your CPU module supports high-speed bus communication to prevent data bottlenecks at the processor level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I switch between voltage and current input modes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou select the input range and mode via the PLC configuration software. Additionally, ensure you wire the terminals according to the specific voltage or current diagram provided in the Yokogawa technical manual to engage the internal precision resistors for current loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module suitable for legacy system replacements?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We provide these units as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estock to replace failing or aging modules in existing FA-M3 racks. Replacing a worn module with a new F3DA04-6R restores factory-spec accuracy and system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use all 4 points for different signal ranges simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module allows independent configuration for its input points. This enables you to monitor a 4-20mA flow meter on one channel while simultaneously tracking a -10V to +10V position sensor on another.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777501262133,"sku":"F3DA04-6R","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3DA04-6R.png?v=1776916890"},{"product_id":"f3cu04-0s-yokogawa-fa-m3-temperature-control-and-pid-module","title":"F3CU04-0S Yokogawa | FA-M3 Temperature Control and PID Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3CU04-0S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a dedicated Temperature Control and PID Module within the FA-M3 multi-controller system. This module executes complex thermal algorithms independently of the main CPU, ensuring high-speed, localized process regulation. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, providing the precise mathematical modeling required for stable heating and cooling loops in plastic extrusion, chemical processing, and semiconductor manufacturing.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF3CU04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-loop Temperature Control and PID Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard feature set \/ Basic configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStyle S hardware revision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e460 mA at 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 points per loop (dedicated relays for Alarms 1 \u0026amp; 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFilter Logic\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Alarm Delay Timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarm-up Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 minutes minimum for precision stability\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Change Limit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10°C\/h maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOne 18-point terminal block (M3.5 screws)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Thermal Stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3CU04-0S enforces a 30-minute warm-up cycle to stabilize internal reference voltages. This protocol ensures that the module achieves its rated accuracy before the control loop begins active regulation, preventing early-cycle process drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransient Alarm Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated alarm delay timer prevents \"nuisance\" trips caused by momentary signal noise or thermal overshoot. This feature allows the process to fluctuate within narrow, safe tolerances without triggering an immediate system shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Mechanical Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 18-point terminal block utilizes M3.5 screws, providing higher torque capacity than standard spring-clamps. This design ensures that field wiring remains secure in environments prone to high-frequency mechanical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStrict Thermal Compensation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module regulates its internal compensation logic to handle ambient temperature shifts up to 10°C\/h. This capability maintains PID loop integrity even when control cabinets sit near fluctuating heat sources or drafty industrial zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F3CU04-0S support vertical mounting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware design strictly requires a vertical orientation within the rack. You must not mount this module in a horizontal or inverted position, as doing so disrupts the natural convection required to cool the internal PID processing circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use all four alarm points to trigger external hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module calculates four alarm points per loop; however, only Alarms 1 and 2 possess dedicated input relays for physical switching. You must process Alarms 3 and 4 via the internal PLC registers for software-level interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type best suits the M3.5 screw terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend using ring or spade-type crimp terminals for the 18-point block. This ensures maximum surface contact and prevents wire fraying, which is essential for maintaining the low-impedance path required for accurate thermocouple readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle sensor failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3CU04-0S includes burnout detection logic. If a sensor fails or a wire breaks, the PID algorithm immediately transitions to a pre-defined \"safe\" output value or triggers the Alarm 1 relay to signal a hardware fault to the operator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777509224757,"sku":"F3CU04-0S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3CU04-0S.png?v=1776923446"},{"product_id":"yokogawa-ycb111-m025-10base-5-v-net-er-bus-coaxial-cable","title":"Yokogawa YCB111-M025 10BASE-5 V net\/ER bus Coaxial Cable","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa YCB111-M025\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the heavy-duty communication backbone for Yokogawa Distributed Control Systems (DCS). This 25-meter industrial coaxial cable facilitates high-speed data transmission across V net and ER bus layers, linking system cabinets and remote I\/O nodes with deterministic precision. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your network maintains zero packet loss in environments characterized by severe electromagnetic interference.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eYCB111\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModel Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10BASE-5 Thick Coaxial Cable for DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-M025\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLength Suffix\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 Meters (approx. 82 feet) fixed length\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocol Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEEE 802.3 10BASE-5 (Thick Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 Meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV net, ER bus, ESB bus, RIO bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Design\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolderless connectors for M4 screw terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-density EMI\/RFI braid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm minimum (permanent installation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eJacket Material\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial-grade flame-retardant polymer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Backbone Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe YCB111-M025 utilizes 10BASE-5 \"Thick Ethernet\" technology, which offers significantly lower signal attenuation compared to the thinner YCB141 series. This makes it the superior choice for primary trunk lines between critical DCS nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolderless Termination Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable features integrated solderless connectors designed for M4 screw terminals. This engineering choice allows field technicians to secure connections rapidly without specialized soldering tools, effectively lowering the Mean Time to Repair (MTTR) during system maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA high-density EMI\/RFI braid encases the inner conductor, neutralizing the effects of magnetic fields generated by nearby high-voltage motors or switchgear. This shielding ensures that process data remains synchronized without jitter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flame-retardant outer jacket protects the core against chemical exposure and thermal stress. The specified 100 mm bend radius allows for clean routing through industrial cable trays while preventing internal dielectric deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the YCB111-M025 to replace a YCB141 cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe YCB111-M025 uses a 10BASE-5 standard, whereas the YCB141 typically follows 10BASE-2 (Thin Ethernet). While they serve similar network architectures like V net, they require different connector types (Screw terminal vs. BNC). Verify your hardware interface before switching models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this cable improve system reliability in high-vibration areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe solderless M4 screw terminal design provides a mechanical lock that resists loosening better than standard snap-on connectors. This ensures continuous contact in refinery or power plant environments where machinery vibration is constant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum distance supported by this cable type?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs a 10BASE-5 cable, it supports longer individual segments than thin coaxial alternatives. For runs exceeding 25 meters, you can interconnect multiple YCB111 segments using approved Yokogawa bus repeaters or joiners to maintain signal strength.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable suitable for ProSafe-RS safety networks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The YCB111-M025 provides the physical layer required for both Centum VP and ProSafe-RS safety instrumented systems (SIS), ensuring high-availability communication for safety-critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777601990965,"sku":"YCB141-M025","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/YCB301-C100_99075136-c116-4065-8143-1428cd3c54a2.png?v=1776924127"},{"product_id":"ycb141-m035-v-net-er-bus-coaxial-communication-cable-yokogawa","title":"YCB141-M035 V net\/ER Bus Coaxial Communication Cable | Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa YCB141-M035\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a high-integrity physical layer for Yokogawa’s proprietary Distributed Control System (DCS) networks. This 35-meter coaxial cable facilitates seamless data exchange across V net, ER bus, ESB bus, and RIO bus architectures. Engineered to the 10BASE-2 standard, it maintains deterministic communication between Field Control Stations (FCS) and I\/O nodes. We supply this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control network meets factory-spec attenuation and impedance requirements.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eYCB141\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10BASE-2 Coaxial Cable for DCS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-M035\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 Meters (approx. 115 feet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\/NL\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA Non-Incendive Instrumentation support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEEE 802.3 10BASE-2 (Thin Ethernet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFixed Length\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 Meters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTermination Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSolderless lug for M4 screw terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBend Radius\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 mm minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eV net, ER bus, ESB bus, RIO bus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCSA non-incendive (with \/NL option)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Signal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe YCB141-M035 features high-density shielding to repel electromagnetic interference (EMI) and radio frequency interference (RFI). This ensures that critical process data travels without packet loss in electrically noisy environments near high-voltage switchgear or variable frequency drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Installation Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a minimum bending radius of only 50 mm, this cable allows for efficient routing within crowded cable trays and tight cabinet enclosures. It prevents dielectric deformation during installation, maintaining the consistent impedance necessary for 10BASE-2 networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolderless Connection Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes solderless lugs compatible with M4 screw terminals. This design eliminates the failure points associated with cold solder joints and provides a vibration-resistant mechanical bond, essential for refineries and offshore platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specialized jacket material withstands temperature extremes from -20°C to +70°C. This prevents cracking in cold-start conditions and resists degradation in high-heat industrial zones, ensuring a long service life without signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the YCB141-M035 in hazardous areas?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, if you select the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/NL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix. This version supports CSA non-incendive instrumentation standards, allowing safe operation in specific hazardous locations where traditional cabling might pose a risk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable require specialized tools for termination?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The solderless lug design allows for direct mounting to M4 screw terminals. You only require a standard torque screwdriver to ensure a secure, low-resistance connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 35-meter length affect the total bus segment limit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must include the 35-meter length of the YCB141-M035 in your total 10BASE-2 segment calculation. Ensure the cumulative length of all cables and connectors in a single segment does not exceed the 185-meter maximum limit defined by Yokogawa system specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with the older YCB141-M030?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Both cables share identical electrical characteristics and 10BASE-2 compliance. The M035 version simply provides an additional 5 meters of length to accommodate larger cabinet-to-cabinet distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777611034933,"sku":"YCB141-M035","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/YCB301-C100_c3783af0-34e7-4632-9fc0-fb2850ba9643.png?v=1776924283"},{"product_id":"aip830-101-operation-keyboard-for-single-loop-control-yokogawa","title":"AIP830-101 Operation Keyboard for Single-Loop Control | Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AIP830-101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized flat-panel operation keyboard engineered for precise single-loop control within industrial automation environments. This high-integrity interface allows operators to monitor and adjust process variables directly from a central control station. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring seamless integration with your existing Yokogawa DCS infrastructure and Human Interface Stations (HIS).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlat-panel Operation Keyboard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePC Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x USB Type A Connectors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAudio\/Sound Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSB 1.1 (Full speed, bus powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5V ± 5% (Supplied via PC USB port)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.3 cm x 22.9 cm x 7.6 cm (8.0\" x 9.0\" x 3.0\")\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.3 kg (5 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5°C to 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20% to 80% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Tactile Response for Process Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flat-panel design provides immediate access to control parameters. It eliminates the complexities of standard commercial keyboards, allowing operators to execute rapid setpoint changes and alarm acknowledgments without navigating multiple software menus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play USB Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AIP830-101 utilizes dual USB Type A connectors for both data and power. This design removes the need for external power supplies and proprietary communication cards, simplifying cabinet wiring and reducing potential failure points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit weighs 2.3 kg and features a rugged chassis that resists the vibration and dust typical of control room environments. This heavy-duty build prevents the device from shifting during intensive operation periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Sound Functions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe keyboard supports USB-powered sound functions to provide audible feedback for keystrokes and system alerts. This secondary sensory input ensures operators confirm actions in high-noise industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AIP830-101 require an external power adapter?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The device draws all necessary power (5V DC) directly from the PC's USB port. It consumes a maximum of 1A, fitting within standard industrial PC power budgets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this keyboard with a standard Windows-based HIS?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The AIP830-101 interfaces via USB and functions within the Yokogawa CENTUM VP or CS 3000 software environment. Always verify that your specific HIS hardware supports high-power USB devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"101\" suffix in the model number?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe suffix denotes the specific hardware revision and regional layout. As a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit, the AIP830-101 meets the latest factory standards for compatibility and internal component longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the keyboard resistant to spills?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flat-panel surface offers better protection against debris and minor splashes compared to traditional mechanical keyboards. However, you should maintain the unit within the specified 20% to 80% non-condensing humidity range to protect the internal USB 1.1 circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777612771637,"sku":"AIP830-101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/AIP830-101.png?v=1776924541"},{"product_id":"yokogawa-f3lc11-1f-fa-m3-personal-computer-link-module","title":"Yokogawa F3LC11-1F FA-M3 Personal Computer Link Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3LC11-1F\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-speed communication gateway between FA-M3 series PLCs and external personal computers or workstations. This Personal Computer Link Module enables seamless data exchange, system monitoring, and parameter adjustment via the EIA RS-232-C standard. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains a stable, high-fidelity serial link without the timing inconsistencies of used or refurbished hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 99.9589%; height: 195.833px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eInterface Standard\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003eEIA RS-232-C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003e300 bps to 115.2 kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eTransmission Mode\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003eHalf-duplex\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eSynchronization\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003eStart-stop synchronization\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eDistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003e15 meters maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003eD-sub 9-pin (female), M2.6 screw\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eError Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003eParity check, checksum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003e320 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 40.1016%; height: 19.5833px;\"\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 57.4378%; height: 19.5833px;\"\u003e\u003cspan\u003e0.11 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Throughput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3LC11-1F supports transmission speeds up to 115.2 kbps. This capability allows for rapid data logging and real-time visualization on the host PC, minimizing the latency between field signal changes and operator screen updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Command Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module manages the RS-232-C control lines (RS\/ER) in an \"always on\" state. This simplifies the handshake configuration, allowing engineers to establish a stable connection with external devices using minimal cabling complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt only 2.89 cm wide, this module maximizes rack density within the FA-M3 chassis. The lightweight 0.11 kg design reduces mechanical stress on the backplane, making it ideal for mobile control skids or high-density enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Data Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated parity checks and checksum calculations verify every data packet. This internal error detection ensures that electromagnetic noise does not corrupt critical control parameters during transmission between the PLC and the PC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the F3LC11-1F operate in full-duplex mode?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. This module utilizes a half-duplex transmission mode. Ensure your host PC communication software supports half-duplex timing to prevent data collisions on the RS-232-C line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum cable length for a stable connection?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe EIA RS-232-C standard limits the transmission distance to 15 meters. For applications exceeding this range, you must use a signal repeater or convert the link to a different protocol such as RS-422 or Ethernet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide electrical isolation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3LC11-1F is a non-isolated module. To protect the PLC from ground potential differences or surges in harsh environments, we recommend using an external opto-isolator on the RS-232-C line.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the D-sub 9-pin connector compatible with standard PC serial cables?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features a female D-sub 9-pin connector with M2.6 screw threads. Verify that your cable uses the corresponding M2.6 screws rather than the standard UNC 4-40 screws typically found on office PC hardware to ensure a secure mechanical lock.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777615458613,"sku":"F3LC11-1F","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3LE11-1T_7bb8ffb7-110f-45ab-8771-b47ab7319734.png?v=1776924744"},{"product_id":"yokogawa-f3yd08-6a-fa-m3-transistor-output-module","title":"Yokogawa F3YD08-6A FA-M3 Transistor Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3YD08-6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity digital output interface for the FA-M3 multi-controller series. This module provides eight discrete transistor outputs to drive external solenoids, relays, and pilot lights in high-speed industrial environments. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control loops benefit from ultra-low leakage current and precision voltage switching.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF3YD08\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8-Point Transistor Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-6\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports standard 12-24 VDC industrial loads\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFeatures integrated Active Clamp protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTransistor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax ON Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax OFF Leakage Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eActive Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 mA (5 V DC internal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10-point terminal block with M3.5 screws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInductive Load Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3YD08-6A incorporates an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eActive Clamp\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecircuit. This protector suppresses back-EMF surges generated by inductive loads (like small motors or solenoid valves), preventing semiconductor failure and extending the lifespan of the module under high-frequency switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Data Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a maximum OFF-time leakage current of just\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.1 mA\u003c\/strong\u003e, the module prevents \"ghost\" signals or unintended activation of sensitive high-impedance inputs. This high-isolation characteristic ensures absolute binary states in critical safety interlocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM3.5 screw terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field wiring. These provide significantly higher pull-out resistance than push-in terminals, making the F3YD08-6A ideal for high-vibration machinery found in automotive assembly or textile manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe low\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaximum ON-voltage minimizes heat dissipation within the module during full-load operation. This efficiency maintains low cabinet temperatures, allowing for high-density rack configurations without the need for forced-air cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F3YD08-6A support sinking or sourcing wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module follows specific transistor output logic (typically sinking for \"6A\" variants). Always consult the wiring schematic for your specific FA-M3 rack to ensure the COM terminal matches your field power supply polarity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to switch 110V AC loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The F3YD08-6A operates strictly on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-24 V DC\u003c\/strong\u003e. Attempting to switch AC voltages will permanently damage the transistor circuitry. Use an interposing relay if you need to control AC equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the HOLD\/RESET current specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 10 mA HOLD\/RESET current ensures the internal logic state remains stable even during minor voltage fluctuations. This ensures the output maintains its programmed state if the system undergoes a soft reset or low-power condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I replace a faulty unit without losing the field wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSince the module uses a 10-point terminal block, we recommend labeling all wires before removal. Ensure the power to the external 12-24V DC supply is OFF before disconnecting the M3.5 screws to avoid short circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777620668725,"sku":"F3YD08-6A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3YD08-6A.png?v=1776925101"}],"url":"https:\/\/www.5gplc.com\/collections\/yokogawa-other-series.oembed?type=grid","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}