{"title":"Emerson Epro","description":"\u003cp\u003eEmerson EPRO offers industrial automation modules and devices designed for precise control and seamless integration with DCS and PLC systems. Widely used in manufacturing, process, and energy industries, EPRO products ensure reliable performance, scalable system expansion, and maintainable automation solutions in demanding industrial environments.\u003c\/p\u003e","products":[{"product_id":"emerson-epro-pr6423-010-010-con021-proven-eddy-current-displacement-sensor","title":"Emerson Epro PR6423\/010-010+CON021 Proven Eddy Current Displacement Sensor","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003ePR6423\/010-010+CON021\u003c\/strong\u003e is a German-manufactured eddy current displacement sensor, engineered for precise shaft vibration and displacement monitoring in turbomachinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: PR6423\/010-010 + CON021\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: 8 mm eddy current displacement sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInitial Air Gap\u003c\/strong\u003e: 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP66, IEC 60529\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor only, typical for PR6423 series)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl-medium [\u0026amp;:not(:first-child)]:pt-3.5 pb-1\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProven reliability\u003c\/strong\u003e: Trusted for critical turbomachinery monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision\u003c\/strong\u003e: Detects shaft vibration, axial displacement, and position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Ensures minimal wear and long service life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRobust construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEasy integration\u003c\/strong\u003e: Works seamlessly with CON021 converter modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, gearboxes, pumps, and fans\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085072560437,"sku":"PR6423\/010-010+CON021","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6423010-010_CON021__1.jpg?v=1766455638"},{"product_id":"emerson-epro-pr6426-000-030-con021-916-200-professional-eddy-current-sensor","title":"Emerson Epro PR6426\/000-030+CON021\/916-200 Professional Eddy Current Sensor","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro\u003cstrong\u003e PR6426\/000-030+CON021\/916-200\u003c\/strong\u003e is a professional 32mm eddy current sensor, engineered for non-contact shaft displacement and vibration monitoring in critical turbomachinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: PR6426\/000-030 + CON021\/916-200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: 32 mm eddy current displacement sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: ±4.0 mm linear measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 2 V\/mm (50.8 mV\/mil) ±1.5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 5.5 mm (0.22”)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e: Ferromagnetic steel (42 Cr Mo 4)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous, excursions up to +100 °C for \u0026lt;4 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP66, IEC 60529\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with 1 m cable, no armor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 class=\"text-xl-medium [\u0026amp;:not(:first-child)]:pt-3.5 pb-1\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Ensures minimal wear and long service life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision\u003c\/strong\u003e: Detects shaft position, eccentricity, and motion with excellent stability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Stainless steel housing for harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWide application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and fans\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEasy integration\u003c\/strong\u003e: Works seamlessly with CON021\/916-200 converter modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085088452917,"sku":"PR6426\/000-030+CON021\/916-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426000-030_CON021916-2001.jpg?v=1766456135"},{"product_id":"emerson-epro-pr9350-04-sensor-module-plc-processors-module","title":"Emerson Epro PR9350\/04 Sensor Module PLC Processors Module","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003ePR9350\/04\u003c\/strong\u003e is a professional sensor module designed for PLC processors, enabling precise signal processing and reliable monitoring in industrial automation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: PR9350\/04\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Sensor module for PLC processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Signal conditioning and processing for eddy current sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with PR642x sensor series and CON0xx converter modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP20 (typical for PLC modules)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 250 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable signal processing\u003c\/strong\u003e: Ensures accurate sensor data for PLC systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact design\u003c\/strong\u003e: Easy installation in control cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with multiple EPRO sensor and converter modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial-grade durability\u003c\/strong\u003e: Built for continuous operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnhanced monitoring\u003c\/strong\u003e: Supports vibration and displacement measurement for rotating machinery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085101691189,"sku":"PR9350\/04","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR935004.jpg?v=1766456355"},{"product_id":"emerson-epro-pr6424-006-030-con021-reliable-quality-eddy-current-sensor","title":"Emerson Epro PR6424\/006-030+CON021 Reliable-quality Eddy Current Sensor","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003ePR6424\/006-030+CON021\u003c\/strong\u003e is a reliable 25mm eddy current sensor, engineered for non-contact shaft displacement and vibration monitoring in turbomachinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: PR6424\/006-030 + CON021\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: 25 mm eddy current displacement sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: ±2.0 mm linear measuring range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 4 V\/mm (101.6 mV\/mil) ±1.5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 2.5 mm (0.1”)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTarget Material\u003c\/strong\u003e: Ferromagnetic steel (42 Cr Mo 4)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous, excursions up to +100 °C for \u0026lt;4 hours\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP66, IEC 60529\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with 1 m cable, no armor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision\u003c\/strong\u003e: Detects shaft position, eccentricity, and motion with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Stainless steel housing for harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWide application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and fans\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEasy integration\u003c\/strong\u003e: Works seamlessly with CON021 converter modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085105230133,"sku":"PR6424\/006-030+CON021","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6424006-030_CON021.jpg?v=1766456656"},{"product_id":"emerson-epro-a6740-programmable-logic-card-relay-module","title":"Emerson Epro A6740 Programmable Logic Card Relay Module","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eA6740\u003c\/strong\u003e is a programmable logic card relay module designed for industrial control systems, offering reliable signal switching and integration with PLCs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: A6740\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Programmable logic card relay module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Signal switching and relay control for PLC applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Integrates with EPRO monitoring and protection systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP20 (typical for control modules)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 250 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable switching\u003c\/strong\u003e: Provides stable relay operation for industrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact module\u003c\/strong\u003e: Fits easily into PLC racks and control cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with multiple Emerson EPRO systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable build\u003c\/strong\u003e: Designed for continuous operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnhanced control\u003c\/strong\u003e: Supports programmable logic functions for advanced monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085112439093,"sku":"A6740","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/A6740.png?v=1766457153"},{"product_id":"emerson-epro-a6410-dual-channel-position-expansion-monitoring-module","title":"Emerson Epro A6410 Dual Channel Position Expansion Monitoring Module","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eA6410\u003c\/strong\u003e is a dual channel position expansion monitoring module designed for industrial machinery, enabling precise position detection and integration with monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: A6410\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Dual channel position expansion monitoring module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Provides extended monitoring capability for shaft position and displacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with EPRO monitoring racks and sensor modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e: IP20 (typical for control modules)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 250 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDual channel monitoring\u003c\/strong\u003e: Supports simultaneous position measurement from two sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable operation\u003c\/strong\u003e: Ensures stable monitoring in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact module\u003c\/strong\u003e: Fits easily into monitoring racks and control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with multiple Emerson EPRO modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial durability\u003c\/strong\u003e: Built for continuous operation in demanding applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085140554037,"sku":"A6410","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/A6410.jpg?v=1766457876"},{"product_id":"emerson-epro-con041-pr6423-00r-111-eddy-current-sensor-with-converter","title":"Emerson Epro CON041+PR6423\/00R-111 Eddy Current Sensor with Converter","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro\u003cstrong\u003e CON041+PR6423\/00R-111 \u003c\/strong\u003eis a proven eddy current sensor with converter, designed for non-contact shaft displacement and vibration monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON041 + PR6423\/00R-111\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current displacement sensor with converter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON041 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision\u003c\/strong\u003e: Detects shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON041 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085159919925,"sku":"CON041+PR6423\/00R-111","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON041_PR642300R-111.jpg?v=1766458082"},{"product_id":"emerson-epro-pr9268-617-100-cost-effective-sensor-probe","title":"Emerson Epro PR9268\/617-100 Cost-effective Sensor Probe","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003ePR9268\/617-100\u003c\/strong\u003e is a cost-effective sensor probe designed for industrial monitoring applications, offering reliable signal detection and integration with EPRO systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: PR9268\/617-100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Sensor probe for vibration and displacement monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Signal detection and transmission for machinery protection systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with EPRO monitoring racks and converter modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCost-effective solution\u003c\/strong\u003e: Provides reliable monitoring at reduced system cost\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact probe\u003c\/strong\u003e: Easy installation in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable detection\u003c\/strong\u003e: Ensures stable signal transmission for machinery monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Built for continuous operation in demanding applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with multiple Emerson EPRO modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085165228341,"sku":"PR9268\/617-100","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR9268617-100.png?v=1766459081"},{"product_id":"emerson-epro-con021-pr6423-000-010-reliable-quality-eddy-current-system","title":"Emerson Epro CON021+PR6423\/000-010 Reliable-quality Eddy Current System","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eCON021+PR6423\/000-010\u003c\/strong\u003e is a reliable eddy current system designed for non-contact shaft displacement and vibration monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON021 + PR6423\/000-010\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current displacement sensor with converter system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON021 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision\u003c\/strong\u003e: Detects shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON021 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085204943157,"sku":"CON021+PR6423\/000-010","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6423000-010.png?v=1766459455"},{"product_id":"emerson-epro-con021-pr6423-10r-030-high-performance-vibration-sensor","title":"Emerson Epro CON021+PR6423\/10R-030 High-performance Vibration Sensor","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eCON021+PR6423\/10R-030\u003c\/strong\u003e is a high-performance vibration sensor system designed for non-contact shaft displacement and vibration monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON021 + PR6423\/10R-030\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current vibration sensor with converter system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON021 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision detection\u003c\/strong\u003e: Monitors shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON021 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085238628661,"sku":"CON021+PR6423\/10R-030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6423000-010_2e077252-b36e-49e8-ae93-2b72cc25a1d8.png?v=1766459650"},{"product_id":"emerson-epro-con021-pr6423-000-040-eddy-current-sensor-with-converter","title":"Emerson Epro CON021+PR6423\/000-040 Eddy Current Sensor with Converter","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eCON021+PR6423\/000-040\u003c\/strong\u003e is a reliable eddy current sensor system with converter, designed for non-contact shaft displacement and vibration monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON021 + PR6423\/000-040\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current displacement sensor with converter system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON021 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision detection\u003c\/strong\u003e: Monitors shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON021 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085259862325,"sku":"CON021+PR6423\/000-040","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6424006-030_CON021_f3b041d3-9274-4312-b46d-a0c48ad568c1.jpg?v=1766459869"},{"product_id":"emerson-epro-pr9268-200-000-stable-electrodynamic-velocity-sensor","title":"Emerson Epro PR9268\/200-000 Stable Electrodynamic Velocity Sensor","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003ePR9268\/200-000\u003c\/strong\u003e is a stable electrodynamic velocity sensor designed for vibration monitoring in industrial machinery, ensuring reliable signal detection and continuous operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: PR9268\/200-000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Electrodynamic velocity sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Measures vibration velocity for machinery protection systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: Typical 10 Hz to 1 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: Proportional to vibration velocity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +80 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 250 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStable measurement\u003c\/strong\u003e: Provides consistent vibration velocity monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCost-effective solution\u003c\/strong\u003e: Reliable performance with reduced system cost\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Built for harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact design\u003c\/strong\u003e: Easy installation in machinery setups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with Emerson EPRO monitoring systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085269627189,"sku":"PR9268\/200-000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR9268200-000.jpg?v=1766460189"},{"product_id":"emerson-epro-con021-pr6423-01b-030-cn-reliable-eddy-current-sensor","title":"Emerson Epro CON021+PR6423\/01B-030-CN Reliable Eddy Current Sensor","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eCON021+PR6423\/01B-030-CN\u003c\/strong\u003e is a reliable eddy current sensor system with converter, designed for non-contact shaft displacement and vibration monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON021 + PR6423\/01B-030-CN\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current displacement sensor with converter system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON021 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision detection\u003c\/strong\u003e: Monitors shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON021 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085286863157,"sku":"CON021+PR6423\/01B-030-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR642301B-030-CN__1.jpg?v=1766460409"},{"product_id":"emerson-epro-con021-pr6423-010-010-robust-eddy-current-displacement-sensor","title":"Emerson Epro CON021+PR6423\/010-010 Robust Eddy Current Displacement Sensor","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eCON021+PR6423\/010-010\u003c\/strong\u003e is a robust eddy current displacement sensor system with converter, designed for non-contact shaft vibration and displacement monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON021 + PR6423\/010-010\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current displacement sensor with converter system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON021 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision detection\u003c\/strong\u003e: Monitors shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON021 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085290729781,"sku":"CON021+PR6423\/010-010","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6423010-010_CON021__1_4958ac99-46e0-4738-88b5-4b869e873345.jpg?v=1766460558"},{"product_id":"emerson-epro-con021-pr6423-003-030-high-performance-vibration-sensor","title":"Emerson Epro CON021+PR6423\/003-030 High-performance Vibration Sensor","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eCON021+PR6423\/003-030\u003c\/strong\u003e is a high-performance vibration sensor system with converter, designed for non-contact shaft displacement and vibration monitoring in industrial machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: CON021 + PR6423\/003-030\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Eddy current vibration sensor with converter system\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: Linear up to 2 mm (80 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e: 8 V\/mm (203.2 mV\/mil) ±5%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Air Gap\u003c\/strong\u003e: Approx. 0.5 mm (20 mils)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter\u003c\/strong\u003e: CON021 module for signal processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 200 g (sensor head with cable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-contact measurement\u003c\/strong\u003e: Provides long service life with minimal wear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh precision detection\u003c\/strong\u003e: Monitors shaft vibration and displacement with stable output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable converter integration\u003c\/strong\u003e: CON021 ensures accurate signal conditioning\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Resistant to harsh industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVersatile application\u003c\/strong\u003e: Suitable for turbines, compressors, pumps, and rotating equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085292990773,"sku":"CON021+PR6423\/003-030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6424006-030_CON021_c0060fd8-1763-4a6c-b1d8-198ead02f5bc.jpg?v=1766460732"},{"product_id":"emerson-epro-mms6120-reliable-dual-channel-bearing-vibration-monitor","title":"Emerson Epro MMS6120 Reliable Dual Channel Bearing Vibration Monitor","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eMMS6120\u003c\/strong\u003e is a reliable dual channel bearing vibration monitor designed for continuous machinery protection and precise vibration measurement in industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: MMS6120\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Dual channel bearing vibration monitor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Measures and monitors bearing vibration levels for machinery protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: Two independent monitoring channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSignal Input\u003c\/strong\u003e: Compatible with velocity and displacement sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 300 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDual channel monitoring\u003c\/strong\u003e: Provides simultaneous measurement from two sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable operation\u003c\/strong\u003e: Ensures stable monitoring for critical machinery protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Works with Emerson EPRO sensors and monitoring racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIndustrial durability\u003c\/strong\u003e: Built for continuous operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact design\u003c\/strong\u003e: Easy installation in control systems and monitoring cabinets\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085299675445,"sku":"MMS6120","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MMS6120.jpg?v=1766461438"},{"product_id":"emerson-epro-mms6410-reliable-vibration-monitoring-board","title":"Emerson Epro MMS6410 Reliable Vibration Monitoring Board","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eMMS6410\u003c\/strong\u003e is a reliable vibration monitoring board designed for continuous machinery protection, enabling precise vibration detection and integration with monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: MMS6410\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Vibration monitoring board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Provides vibration signal processing and monitoring for rotating machinery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with EPRO racks and sensor modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: Supports multiple vibration input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 300 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable monitoring\u003c\/strong\u003e: Ensures stable vibration detection for machinery protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulti-channel capability\u003c\/strong\u003e: Supports integration of several vibration sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact board\u003c\/strong\u003e: Fits easily into monitoring racks and control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Built for continuous operation in industrial environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with Emerson EPRO monitoring solutions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085311471925,"sku":"MMS6410","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MMS6410.jpg?v=1766461673"},{"product_id":"emerson-epro-mms6140-vibration-monitoring-module-100-brand-and-new","title":"Emerson Epro MMS6140 Vibration Monitoring Module 100%Brand and New","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eMMS6140 \u003c\/strong\u003eis a vibration monitoring module designed for continuous machinery protection, providing precise vibration detection and integration with monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: MMS6140\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Vibration monitoring module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Processes vibration signals for machinery protection and monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with EPRO racks and sensor modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: Supports multiple vibration input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 300 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable monitoring\u003c\/strong\u003e: Ensures stable vibration detection for industrial machinery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulti-channel capability\u003c\/strong\u003e: Supports integration of several vibration sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact module\u003c\/strong\u003e: Fits easily into monitoring racks and control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Built for continuous operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with Emerson EPRO monitoring solutions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085319893301,"sku":"MMS6140","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MMS6140.jpg?v=1766462048"},{"product_id":"emerson-epro-mms6110-shaft-vibration-monitoring-module-100-brand-and-new","title":"Emerson Epro MMS6110 Shaft Vibration Monitoring Module 100% Brand and New","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Emerson Epro \u003cstrong\u003eMMS6110\u003c\/strong\u003e is a shaft vibration monitoring module designed for continuous machinery protection, providing precise vibration detection and integration with monitoring systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Emerson \/ EPRO\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e: Germany\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: MMS6110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType\u003c\/strong\u003e: Shaft vibration monitoring module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Processes shaft vibration signals for machinery protection and monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with EPRO racks and sensor modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e: Supports multiple vibration input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to +45 °C continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 300 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable monitoring\u003c\/strong\u003e: Ensures stable shaft vibration detection for industrial machinery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMulti-channel capability\u003c\/strong\u003e: Supports integration of several vibration sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact module\u003c\/strong\u003e: Fits easily into monitoring racks and control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable construction\u003c\/strong\u003e: Built for continuous operation in demanding environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFlexible integration\u003c\/strong\u003e: Compatible with Emerson EPRO monitoring solutions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52085325168949,"sku":"MMS6110","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MMS6110.jpg?v=1766462247"},{"product_id":"1747-m11-allen-bradley-slc-500-memory-module-32kb-eeprom","title":"1747-M11 Allen-Bradley | SLC 500 Memory Module | 32KB EEPROM","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1747-M11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a memory module adapter designed for the SLC 500 series, providing 32KB of EEPROM memory to back up user programs for select SLC 500 processors. This module ensures reliable and fast memory backup for critical control processes. It is compatible with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 5\/03\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5\/04\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5\/05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessors, offering flexible integration and high performance for industrial automation applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMemory Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEEPROM\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUser Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32KB (64,000 words)\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 5\/03\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5\/04\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5\/05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessors\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBackup Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlash EEPROM for reliable data storage\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProgram Scan Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.9 milliseconds for quick processing\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O Scan Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.225 milliseconds for fast data communication\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSupported Processors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1747-L532, 1747-L541, 1747-L542, 1747-L543\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIncompatible Modules:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes not support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1746-BAS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1746-BAST\u003c\/strong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadapter for PROM programmer installation\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRockwell Automation\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePart Number\/Catalog No.:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M11\u003c\/strong\u003e\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSLC 500\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMemory Module Adapter\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMemory Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32KB\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O Chassis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 3 chassis\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eChassis Slots:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 30 slots\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet, RS-232\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProgram Scan Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.9 ms\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O Scan Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.225 ms\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to back up control programs and data for a wide range of industrial automation systems, particularly those using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley SLC 500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessors. Typical applications include:\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIndustrial Control Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures program data retention during power outages\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eManufacturing Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides memory backup for assembly lines and machine control systems\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProcess Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsed for critical data backup in chemical, food processing, and pharmaceutical industries\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBuilding Management Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStores and backs up data for HVAC and energy management systems\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReliable Data Backup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlash EEPROM ensures that user programs are safely backed up and retrievable\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFast Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eQuick scan times (0.9 ms for programs, 0.225 ms for I\/O) optimize overall system performance\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEase of Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with various SLC 500 processors, offering flexibility in system configurations\u003cbr\u003e•\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCost-effective:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA cost-efficient solution for extending memory capabilities without requiring a new controller\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which processors are compatible with the\u003cspan\u003e \u003c\/span\u003e1747-M11?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 5\/03\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 5\/04\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 5\/05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the memory size of the\u003cspan\u003e \u003c\/span\u003e1747-M11?\u003c\/strong\u003e\u003cbr\u003eA2: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32KB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof user memory (64,000 words), which is used to back up control programs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the\u003cspan\u003e \u003c\/span\u003e1747-M11\u003cspan\u003e \u003c\/span\u003erequire any special installation?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M15\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadapter for installing a PROM programmer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the scan time of the\u003cspan\u003e \u003c\/span\u003e1747-M11\u003cspan\u003e \u003c\/span\u003emodule?\u003c\/strong\u003e\u003cbr\u003eA4: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1747-M11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogram scan time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof 0.9 ms and an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O scan time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof 0.225 ms, providing fast system performance.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52192918110517,"sku":"1747-M11","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1747-M11.jpg?v=1768361166"},{"product_id":"1785-me32-allen-bradleyplc-5-30-eeprom-memory-module-32k-words","title":"1785-ME32 | Allen-BradleyPLC-5\/30 EEPROM Memory Module，32K Words","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen-Bradley 1785-ME32\u003c\/strong\u003e is a 32K word EEPROM memory module designed for PLC-5 controllers. It provides non-volatile program backup and storage, ensuring reliable operation in industrial automation systems. Compatible with standard PLC-5 processors, this module supports program retention and system recovery, making it essential for legacy PLC-5 installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen-Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e PLC-5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e EEPROM Memory Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1785-ME32\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.19 lbs (0.09 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory Size\u003c\/strong\u003e 32K words EEPROM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e Program backup and storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e Standard PLC-5 processors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAdditional Memory\u003c\/strong\u003e 6K words SRAM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Requirement\u003c\/strong\u003e 2.5 A at 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Analog I\/O\u003c\/strong\u003e 3072 channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Scan Time per Rack\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e10 ms at 57.6 kbit\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e7 ms at 115.2 kbit\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e3 ms at 230.4 kbit\/s\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum I\/O Chassis Supported\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTotal: 93\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExtended Local: 0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUniversal Remote: Up to 32 per I\/O link\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e RS-232-C, RS-422-A, RS-423-A (1 port)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExpansion\u003c\/strong\u003e Control coprocessor expansion port available\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProgram backup for PLC-5 controllers in industrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy system support requiring EEPROM-based storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplications needing reliable non-volatile memory retention\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLarge-scale control systems with extensive I\/O requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the memory size of the 1785-ME32?\u003c\/strong\u003e  A: It provides 32K words of EEPROM memory plus 6K words of SRAM.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which PLCs are compatible with this module?\u003c\/strong\u003e  A: It is designed for use with standard PLC-5 processors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the backplane current requirement?\u003c\/strong\u003e  A: 2.5 A at 5 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparison with Similar Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1785-ME16\u003c\/strong\u003e: 16K word EEPROM memory module.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1785-ME32\u003c\/strong\u003e: 32K word EEPROM memory module for larger programs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1785-ME64\u003c\/strong\u003e: 64K word EEPROM memory module for extended applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52365916897589,"sku":"1785-ME32","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1785-ME32.jpg?v=1771917735"},{"product_id":"1747-m1-allen-bradley-slc-500-eeprom-memory-module","title":"1747-M1 | Allen Bradley SLC 500 EEPROM Memory Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1747-M1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity non-volatile memory storage solution for the SLC 500 controller platform. This EEPROM module provides a secure repository for user programs and data tables, ensuring the processor retains critical logic during power loss or battery failure. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, serving as a vital hardware backup for legacy SLC 5\/01 and 5\/02 systems to prevent costly downtime and loss of automation code.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe 1747-M1 provides specialized storage parameters for SLC 500 processors:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEEPROM Memory Device\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Kilobytes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstruction Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,000 Instructions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile Program\/Data Table Storage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackup Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlash\/EEPROM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 lbs (0.11 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Series\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSLC 500 (Modular and Fixed)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Scan Time Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.225 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Logic Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1747-M1 utilizes EEPROM technology to store the controller's executive code and data. This eliminates reliance on the internal RAM battery, protecting your industrial process from logic erasure during long-term shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid System Recovery:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a processor fault or hardware swap, the 1747-M1 allows the new controller to auto-load the stored program. This \"Plug-and-Play\" recovery capability significantly reduces Mean Time to Repair (MTTR) in critical manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Scan Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports high-speed execution with a 0.9 ms program scan time and a 0.225 ms I\/O scan time. This ensures that the addition of external memory does not compromise the high-speed response required for discrete control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Compact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWeighing only 0.25 lbs, the module plugs directly into the processor’s internal memory socket. This internal mounting preserves valuable chassis slots for I\/O modules while providing maximum data protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware-Based Code Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnce you burn the program to the 1747-M1, the module acts as a physical \"Master Copy.\" This prevents unauthorized or accidental modifications to the active controller RAM from becoming permanent, maintaining the original validated logic state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1747-M1 require an external power source to retain data?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The EEPROM technology retains all stored data and instructions without any power. You can store this module on a shelf or inside an unpowered rack for years without losing the program.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Allen Bradley processors support the 1747-M1 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module specifically supports the SLC 5\/01 and SLC 5\/02 modular processors, as well as several fixed SLC 500 controllers. Always verify the memory socket compatibility on your specific CPU before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the procedure for transferring a program to the 1747-M1?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must utilize the \"Burn to EEPROM\" command within your programming software (such as RSLogix 500). The processor transfers the contents of its active RAM to the 1747-M1 module for permanent storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a factory-sealed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We guarantee this 1747-M1 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware. It arrives in the original Allen Bradley factory-sealed anti-static packaging with the verifiable UPC (662073521648) intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52477510549813,"sku":"1747-M1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1747-M1.png?v=1774420624"},{"product_id":"epro-a6210-16-bit-canopen-digital-and-analog-i-o-module","title":"EPRO A6210 16-bit CANopen Digital and Analog I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEPRO A6210\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density, 16-bit I\/O expansion module designed for seamless integration into sophisticated industrial control architectures. This versatile module bridges the gap between field-level sensors and supervisory control systems via the robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCANopen\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring peak performance for machinery protection and process automation tasks where signal timing and accuracy remain paramount.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe A6210 optimizes cabinet space while providing a high concentration of digital and analog interface points.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA6210\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit architecture\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCANopen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 x 100 x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Year\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density I\/O Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe A6210 packs 24 digital inputs and 16 digital outputs into a compact 100mm frame. This configuration allows engineers to consolidate field wiring, effectively reducing the overall footprint of control cabinets in space-constrained environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e16-bit Processing Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal 16-bit architecture ensures high-resolution data handling. This precision minimizes quantization errors when processing the two onboard analog inputs, providing more accurate feedback for critical process variables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized CANopen Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the CANopen interface, the module facilitates rapid data exchange and \"plug-and-play\" compatibility with a wide range of PLCs and industrial PCs. This standard protocol simplifies network topology and reduces commissioning time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Grade Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to withstand the rigors of continuous industrial operation, the A6120 manages heat dissipation efficiently within its 50mm depth profile. The rugged housing protects internal circuitry against electromagnetic interference (EMI) commonly found in motor control centers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the EPRO A6210 provided in its original factory packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEPRO A6210 modules. Each unit arrives in original factory sealing with the manufacturer's serial number intact, ensuring you receive an authentic, never-before-used component.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the 16-bit architecture benefit my control loop?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 16-bit resolution allows the module to divide input signals into much finer increments compared to standard 8-bit or 12-bit modules. This results in smoother control responses and more granular monitoring of analog sensors, which is vital for high-precision machinery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module with third-party CANopen masters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The EPRO A6210 follows standard CANopen communication profiles. It integrates seamlessly with any controller or gateway that supports the CANopen protocol, allowing for flexible multi-vendor system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 0.5 kg weight affect mounting options?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The lightweight design (0.5 kg) simplifies installation on standard DIN rails. It places minimal mechanical stress on the mounting assembly, making it ideal for mobile machinery or vibration-prone industrial environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52546319515957,"sku":"A6210","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/A61102_d8546c21-7ea4-4357-8ac8-2eb72e2f3851.jpg?v=1775618669"},{"product_id":"emerson-epro-a6370-ams-6300-sis-overspeed-protection-monitor","title":"Emerson EPRO A6370 AMS 6300 SIS Overspeed Protection Monitor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson EPRO A6370\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as the primary safety layer for critical turbomachinery within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMS 6300 SIS (Safety Instrumented System)\u003c\/strong\u003e. This module executes high-speed overspeed detection and protection, ensuring mechanical integrity for turbines and compressors. It employs a sophisticated three-channel architecture to eliminate single points of failure. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, meeting the strict requirements for safety-critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe A6370 integrates high-speed logic with versatile I\/O to maintain continuous monitoring in extreme conditions.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA6370 (EPRO \/ Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree-channel with 2-out-of-3 (2oo3) voting logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReaction Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; Measuring time + 8 milliseconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Sensor Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEddy-Current, Hall-Element, Magnetic (VR)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 Short-circuit-proof outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Electrically isolated 4-20 mA current outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e−20 °C to +65 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e211 × 130 × 43 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType F48 connector card slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 3 Safety Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe A6370 utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-out-of-3 (2oo3) voting logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross three independent channels. This configuration prevents nuisance trips while ensuring the system executes an emergency shutdown if two channels detect an overspeed condition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Fast Reaction Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a critical overspeed event, every millisecond counts. The A6370 initiates a shutdown sequence in less than\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8ms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(plus measuring time), effectively protecting the turbine rotor from catastrophic centrifugal force damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Sensor Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module accepts signals from Eddy-Current, Hall-Element, or Magnetic (VR) sensors. This flexibility allows engineers to standardize on the A6370 regardless of the legacy sensor technology installed on the machine train.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Signal Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo electrically isolated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esend real-time speed data to the DCS or PLC. Simultaneously, seven short-circuit-proof digital outputs handle local alarm and trip signals, ensuring the module communicates effectively with the broader plant control network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for the rack backplane, the module features shock and vibration resistance compliant with rigorous\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC standards\u003c\/strong\u003e. The standard screw terminals ensure secure field wiring that withstands the constant harmonic resonance of power plant environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the A6370 arrive with manufacturer certification for SIL 3 applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We supply the A6370 as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New, factory-original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecomponent. It meets all Emerson\/EPRO safety specifications and carries the necessary certifications for integration into SIL 3 rated Safety Instrumented Systems (SIS).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I replace a single channel without taking the entire protection system offline?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The A6370 inserts into a standard rack backplane via a Type F48 connector. While the 2oo3 logic allows the system to remain operational if one channel fails, you must follow specific plant safety protocols before removing or inserting modules to maintain the safety loop integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the A6370 handle different speed sensor signal levels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module features integrated signal conditioning that automatically accommodates the varying voltage and frequency outputs of Eddy-Current, Hall-Effect, and Magnetic Pick-up sensors. You simply configure the module parameters via the AMS system tools to match your specific sensor type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the lead time for an urgent replacement A6370?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: We currently maintain the A6370 in stock. We typically process and ship orders within 3 days via premium carriers like DHL or FedEx to ensure your critical machinery protection system returns to full service as quickly as possible.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52546339078453,"sku":"A6312\/06","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/A6370.jpg?v=1775619433"},{"product_id":"a6824r-emerson-epro-ams-6500-modbus-and-rack-interface-module","title":"A6824R | Emerson EPRO AMS 6500 Modbus and Rack Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson EPRO A6824R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the central communication gateway for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMS 6500 Machinery Health Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. This module aggregates critical parameters from across the monitor rack and translates them into industry-standard protocols for external systems. By providing a bridge between specialized machinery protection hardware and the plant's control layer, the A6824R ensures that operators receive real-time health data for steam turbines, compressors, and hydro machinery. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee network stability and safety compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe A65824R utilizes a high-density rack-mount design to facilitate high-speed data throughput.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eA6824R (EPRO \/ Emerson)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP and RTU Rack Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAMS 6500, AMS 6500 ATG, SIS Systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN 41494 Rack-mountable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (W x H x L)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e19.98 mm x 128.4 mm x 160 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C to 55°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP\/IP (Ethernet) \u0026amp; Modbus RTU (Serial)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Protocol Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe A6824R outputs data via both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP and Modbus RTU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimultaneously. This allows the module to feed high-speed data to modern Ethernet-based DCS networks while maintaining serial connections for legacy PLC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Parameter Extraction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module reads data from every monitoring card within the AMS 6500 rack. It collects vibration levels, speed, eccentricity, and expansion metrics, consolidating them into a single, organized Modbus map for simplified SCADA integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlantWeb® and DeltaV Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware integrates natively with Emerson’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlantWeb® and DeltaV\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures. This synergy reduces configuration hours and ensures that asset health alerts reach the maintenance workstation without additional middleware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAPI 670 Compliant Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned to meet the stringent requirements of API 670, the A6824R ensures that the machinery protection rack maintains its safety certification even when connected to external digital networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ultra-slim\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19.98 mm width\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaximizes available rack space. This enables the addition of communication capabilities to fully loaded cabinets without requiring expensive enclosure expansions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the A6824R arrive with the original factory serial number and packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. We supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eitems. Every A6824R arrives in its original factory box with all anti-static seals intact and verifiable manufacturing labels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the A6824R bridge data from an AMS 6500 ATG system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The A6824R integrates seamlessly with both standard AMS 6500 and the newer\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMS 6500 ATG\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand SIS protection systems. It provides a unified data interface for various generations of Emerson machinery health hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle communication with legacy serial-based controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module includes a dedicated Modbus RTU port. This allows the card to push dynamic data to legacy serial devices (RS-485) while simultaneously using its Ethernet port for modern TCP\/IP data acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the typical installation process for this interface module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module plugs directly into the designated interface slot of a DIN 41494 compliant rack. Once seated, you configure the Modbus IP address and register map via the standard Emerson configuration software to begin data broadcasting.\u003c\/p\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52546564129077,"sku":"A6824R","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/A6824R.png?v=1775629632"},{"product_id":"allen-bradley-1747-m13-slc-500-eeprom-memory-module","title":"Allen Bradley 1747-M13 SLC 500 EEPROM Memory Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1747-M13\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized non-volatile storage solution for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSLC 500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller platform. This 64 KB EEPROM (Electrically Erasable Programmable Read-Only Memory) module provides a permanent backup for user programs and data tables. It prevents costly downtime by ensuring the PLC retains its logic during extended power outages or battery failures. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock, offering a vital lifeline for maintaining legacy SLC systems that require authentic, high-reliability components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSLC 500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEEPROM (Non-volatile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e64 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgram Scan Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.9 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Scan Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.225 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 °C (32 to 140 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.10 lbs (0.50 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdd-On PC Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePermanent Logic Safeguard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1747-M13 stores the entire processor memory image. In the event of a system-wide power failure or RAM corruption, the processor automatically reloads the program from this EEPROM module. This feature eliminates the need for manual intervention or a programming laptop to restore operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid System Restoration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports an \"Auto-Load on Power-Up\" configuration. When an SLC 500 processor detects a memory error, it pulls the verified 64 KB backup from the 1747-M13 in milliseconds, maintaining a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.9 ms program scan time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand restoring production immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Hardware Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module attaches directly to the SLC 500 processor’s internal socket. This board-level installation keeps the module protected within the processor housing, shielding it from electromagnetic interference (EMI) and physical vibration common in high-density rack environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Data Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard RAM which depends on a lithium battery, the 1747-M13 uses EEPROM technology to hold data indefinitely without an external power source. This provides a long-term storage solution for remote or unmanned stations where regular battery maintenance is impractical.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I transfer the program from the processor to the 1747-M13?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use RSLogix 500 software to initiate a \"Burn to EEPROM\" command. This process copies the current active program in the processor's RAM into the non-volatile cells of the M13 module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1747-M13 compatible with all SLC 500 processors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1747-M13 specifically fits processors with the internal memory module socket, such as the SLC 5\/03, 5\/04, and 5\/05. Always check your specific processor's memory capacity to ensure the 64 KB limit accommodates your entire ladder logic and data table.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a battery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1747-M13 utilizes EEPROM technology, which does not require a battery to retain its data. It acts as the secondary backup precisely for when the primary processor battery fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the condition of this discontinued part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough the manufacturer has moved this model to \"Discontinued\" status, our stock is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. These are factory-original units that have never been used, ensuring the memory cells have zero wear and 100% of their intended service life remaining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52804739727669,"sku":"1747-М13","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1747-_131.png?v=1777531867"},{"product_id":"pr6424-010-140-con011-epro-eddy-current-displacement-transducer","title":"PR6424\/010-140 CON011 | Epro | Eddy Current Displacement Transducer","description":"\u003cp\u003eConfigured for precision shaft displacement monitoring in rotating machinery, the \u003cstrong\u003eEpro PR6424\/010-140\u003c\/strong\u003e (\u003cstrong\u003eCON011\u003c\/strong\u003e Eddy Current Displacement Transducer) provides direct physical electrical execution for measuring relative radial and axial shaft vibration. The system utilizes electromagnetic induction to generate a linear voltage output proportional to the gap between the probe tip and the observed conductive target, facilitating continuous rotor dynamics assessment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6424\/010-140 (CON011)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEpro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 14.0 cm x 19.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePR6424\/010-140\u003c\/strong\u003e system is designed to provide linear signal output across the specified transducer measuring range. Proper eddy-current probe scaling is required to maintain the accuracy of vibration data when interfaced with monitoring instrumentation. During commissioning, operators must perform a gap voltage validation against the -10 VDC target, ensuring the probe tip is positioned within the linear segment of the transducer's sensitivity curve. This calibration is necessary to capture accurate rotor dynamics, including shaft orbits and eccentricities, while minimizing the influence of cross-talk suppression limitations in multi-probe array configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary requirement for achieving accurate displacement readings?\u003c\/p\u003e\n\u003cp\u003eA: The probe tip must be mounted perpendicular to the conductive shaft surface. Any deviation from a 90-degree angle or positioning over a non-conductive area will result in signal nonlinearity and measurement errors.\u003c\/p\u003e\n\u003cp\u003eQ: How does the CON011 module handle high-frequency electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eA: The CON011 system incorporates signal conditioning circuitry designed to reject common-mode noise. Shielding of the coaxial interconnect cable must be continuous and bonded to earth ground at the monitoring rack to ensure effective EMI suppression.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the PR6424 probe tip for surface damage or debris prior to mounting, as irregularities can alter the magnetic field and skew displacement data.\u003c\/li\u003e\n\u003cli\u003eSecure the probe using the provided mounting hardware, ensuring the assembly is vibration-resistant to prevent false readings caused by bracket resonance.\u003c\/li\u003e\n\u003cli\u003eRoute the coaxial signal cabling through dedicated, grounded metallic conduit separate from motor power or AC mains wiring.\u003c\/li\u003e\n\u003cli\u003eVerify that the gap voltage is precisely set to the nominal target value using a high-impedance digital multimeter before engaging the machine in full-speed operation.\u003c\/li\u003e\n\u003cli\u003eInspect all connector interfaces for oxidation or looseness during periodic maintenance cycles to ensure sustained signal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52956490236213,"sku":"CON010+PR6426\/010-140","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON011_PR6424010-140.png?v=1780469067"},{"product_id":"epro-pr6426-010-140-con011-916-120-eddy-current-sensor","title":"Epro PR6426\/010-140 CON011\/916-120 Eddy Current Sensor","description":"\u003cp\u003eConfigured for precision shaft displacement monitoring in rotating machinery, the \u003cstrong\u003eEpro PR6426\/010-140 + CON011\/916-120\u003c\/strong\u003e (\u003cstrong\u003ePR6426\/010-140\u003c\/strong\u003e Eddy Current Sensor) provides direct physical electrical execution for measuring relative radial and axial shaft vibration. The system utilizes electromagnetic induction to generate a linear voltage output proportional to the gap between the 8 mm probe tip and the observed conductive target, facilitating continuous rotor dynamics assessment via a 120-meter extension cable interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6426\/010-140 + CON011\/916-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEpro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 150 deg C (Probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e-24 V DC (± 1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8.0 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003ePR6426\u003c\/strong\u003e system is designed to provide linear signal output across the specified transducer measuring range of 2.0 mm. Proper eddy-current probe scaling is required to maintain the accuracy of vibration data when interfaced with monitoring instrumentation. During commissioning, operators must perform a gap voltage validation against the -10 VDC target, ensuring the probe tip is positioned within the linear segment of the transducer's sensitivity curve. This calibration is necessary to capture accurate rotor dynamics, including shaft orbits and eccentricities, while minimizing the influence of cross-talk suppression limitations in multi-probe array configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the impact of the 120-meter cable length on signal fidelity?\u003c\/p\u003e\n\u003cp\u003eA: The system is designed to compensate for the impedance characteristics of the 120-meter extension cable. Ensure that the specific transducer model matches the cable impedance to prevent signal attenuation and frequency response degradation within the 0 to 10,000 Hz range.\u003c\/p\u003e\n\u003cp\u003eQ: How is the gap voltage validated during site installation?\u003c\/p\u003e\n\u003cp\u003eA: Utilize a high-impedance digital multimeter to measure the output voltage at the monitoring system interface. Adjust the probe distance from the shaft target until the output reads -10 VDC, which corresponds to the midpoint of the linear operating range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the 8 mm probe tip for mechanical damage or metallic debris that could introduce non-linearities into the output signal.\u003c\/li\u003e\n\u003cli\u003eSecure the probe in a rigid mounting bracket to prevent resonant vibrations from contaminating the displacement data.\u003c\/li\u003e\n\u003cli\u003eTerminate the coaxial cable using the provided CON011 connectors, ensuring all connections are shielded and grounded at the rack entry point to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eRoute the 120-meter cable through dedicated, non-metallic conduits if possible to maintain signal integrity and avoid inductive coupling with high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003ePerform a full-scale static calibration check after installation to confirm that the displacement output remains consistent with target gap measurements.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52956528673077,"sku":"PR6426\/010-140+CON011\/916-120","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426010-140_CON011916-120.png?v=1780469325"},{"product_id":"con020-91-signal-conditioner-module-driver-epro","title":"CON020\/91 Signal Conditioner Module Driver | Epro","description":"\u003cp\u003eConfigured for signal conversion in rotating machinery monitoring networks, the \u003cstrong\u003eEpro CON020\/91\u003c\/strong\u003e (\u003cstrong\u003eCON020\/91\u003c\/strong\u003e Signal Conditioner Module Driver) provides direct physical electrical execution for processing transducer inputs into standardized analog signals. The module accepts raw probe inputs and delivers either analog voltage or 4-20 mA current outputs, interfacing directly with TSI monitoring platforms to support continuous data acquisition in machinery protection applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON020\/91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEpro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 22 mm x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eTransducer Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Voltage or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCON020\/91\u003c\/strong\u003e module is engineered to manage critical signal parameters for eddy-current probe scaling within machinery protection systems. It supports the precise adjustment of gain and offset required for gap voltage validation against -10 VDC targets, ensuring that the sensor response remains linear across the transducer's measurement range. To preserve data integrity in high-density rack configurations, the module incorporates internal cross-talk suppression and EMI immunity filters, which are required for reliable rotor dynamics analysis under varying load and speed conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON020\/91 be hot-swapped while the machinery is operating?\u003c\/p\u003e\n\u003cp\u003eA: Module removal or replacement during active operation depends on the backplane architecture and system configuration. Ensure the I\/O channel is inhibited in the monitoring software to prevent a false trip or alarm signal before extracting the module.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 4-20 mA output isolated from the power supply ground?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for industrial integration where loop isolation is required. Consult the system interconnection diagram to confirm if the output stage requires an external isolator to prevent ground loops between the module and the destination input card.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module on a standard DIN rail or designated rack chassis, ensuring the mechanical locking clip is fully engaged.\u003c\/li\u003e\n\u003cli\u003eTerminate signal input cabling using shielded, twisted-pair wire to minimize electromagnetic interference (EMI) ingress.\u003c\/li\u003e\n\u003cli\u003eVerify that the shield drain wire is bonded to the cabinet earth ground at the rack entry point only to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003eSet the internal jumpers or configuration switches to match the desired output mode (voltage or current) before applying 24 VDC power.\u003c\/li\u003e\n\u003cli\u003eConfirm stable signal output at the terminal block using a calibrated multimeter prior to validating the sensor gap voltage at the probe tip.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52956561965365,"sku":"CON020\/91","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426010-140_CON011916-1202_cef4093b-0e21-4f7e-a15b-7584f7f90f0f.png?v=1780469600"},{"product_id":"emerson-epro-con021-913-040-pr6423-015-000-cn-eddy-current-sensor-kit","title":"Emerson EPRO CON021\/913-040+PR6423\/015-000-CN Eddy Current Sensor Kit","description":"\u003cp\u003eConfigured for precision shaft displacement monitoring in rotating machinery, the \u003cstrong\u003eEmerson EPRO CON021\/913-040 + PR6423\/015-000-CN\u003c\/strong\u003e (\u003cstrong\u003eCON021\/913-040\u003c\/strong\u003e Eddy Current Sensor Kit) provides direct physical electrical execution for measuring relative radial and axial shaft vibration. The system utilizes electromagnetic induction to generate linear voltage outputs proportional to the gap between the 8 mm probe tip and the observed conductive target, facilitating continuous rotor dynamics assessment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/913-040 + PR6423\/015-000-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e-23 to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCON021\/913-040\u003c\/strong\u003e converter module is designed to provide linear signal output across the specified transducer measuring range. Proper eddy-current probe scaling is required to maintain the accuracy of vibration data when interfaced with monitoring instrumentation. During commissioning, operators must perform a gap voltage validation against the -10 VDC target, ensuring the probe tip is positioned within the linear segment of the transducer's sensitivity curve. This calibration is necessary to capture accurate rotor dynamics, including shaft orbits and eccentricities, while minimizing the influence of cross-talk suppression limitations in multi-probe array configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the recommended gap voltage setpoint for this sensor kit?\u003c\/p\u003e\n\u003cp\u003eA: The sensor should be adjusted until the output voltage reaches the nominal -10 VDC setpoint at the machine's static center position. This ensures the transducer operates within its linear range for both positive and negative shaft deflections.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CON021\/913-040 module be utilized in environments with high magnetic interference?\u003c\/p\u003e\n\u003cp\u003eA: The converter module is housed in an aluminum alloy enclosure to provide inherent EMI\/RFI immunity. However, signal cabling should be routed in grounded metallic conduit, and shield integrity must be maintained at the rack termination point to ensure cross-talk suppression and signal stability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the probe tip is installed perpendicular to the shaft target surface to prevent signal distortion.\u003c\/li\u003e\n\u003cli\u003eMount the CON021 converter module using the specified 4 x M5 screw pattern, ensuring a low-impedance bond to the equipment chassis for noise suppression.\u003c\/li\u003e\n\u003cli\u003eUtilize high-frequency coaxial cable for all connections between the PR6423 probe and the converter, keeping cable runs as short as possible to maintain the 15 μs rise time performance.\u003c\/li\u003e\n\u003cli\u003eVerify the power supply polarity is strictly -23 VDC to -32 VDC; reverse polarity will result in system failure and potential damage to the converter circuitry.\u003c\/li\u003e\n\u003cli\u003ePerform a static calibration check after installation to confirm that the displacement output remains consistent with the target gap measurements across the full range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52956603842869,"sku":"CON021\/913-040+PR6423\/015-000-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021913-040_PR6423015-000-CN.jpg?v=1780469910"},{"product_id":"emerson-epro-con021-913-040-pr6424-000-000-eddy-current-system","title":"Emerson Epro CON021\/913-040 \u0026 PR6424\/000-000 Eddy Current System","description":"\u003cp\u003eConfigured for non-contact displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro CON021\/913-040\u003c\/strong\u003e (\u003cstrong\u003eCON021\/913-040\u003c\/strong\u003e Eddy Current Sensor) coupled with the \u003cstrong\u003ePR6424\/000-000\u003c\/strong\u003e probe interface provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/913-040 + PR6424\/000-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and oscillator-demodulator geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +125 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal loop-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0.5 mm to 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes electromagnetic induction to generate a linear output proportional to the distance from a conductive target. Proper scaling is required to correlate the sensor output signal to the specific target material's permeability and electrical conductivity. During calibration, the probe gap must be validated to ensure the -10 VDC target range is met for optimal linearity. Maintaining consistent scaling is necessary to accurately monitor rotor dynamics, including radial shaft vibration and axial position, as deviations in gap distance directly impact the signal response.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the sensor probe be installed in environments with high levels of metallic dust?\u003c\/p\u003e\n\u003cp\u003eA: Accumulation of conductive debris on the sensor face can interfere with the electromagnetic field and cause measurement errors. Regular inspection and cleaning of the probe tip are required to maintain signal linearity.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 4-20 mA output signal isolated from the probe head?\u003c\/p\u003e\n\u003cp\u003eA: The associated driver electronics include galvanic isolation to prevent ground loops between the sensor housing and the monitoring system, provided that correct shielding and grounding practices are followed at the termination junction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting bracket provides rigid support to prevent mechanical vibration from influencing the sensor output.\u003c\/li\u003e\n\u003cli\u003eVerify that the target area on the rotating shaft is free of surface imperfections, scratches, or non-conductive coatings to ensure accurate displacement readings.\u003c\/li\u003e\n\u003cli\u003eObserve the minimum installation distance from other metallic objects or adjacent sensors to prevent cross-talk interference.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines separate from high-current power cables to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTighten the probe locking nuts to the torque specified in the mechanical manual to prevent loosening under high-frequency operational vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008965927221,"sku":"CON021\/913-040+PR6424\/000-000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426010-140_CON011916-1202_78d1f85c-b334-43fc-8aa1-381ad05023cb.png?v=1781680066"},{"product_id":"con021-916-120-emerson-epro-eddy-current-signal-converter","title":"CON021\/916-120 | Emerson Epro | Eddy Current Signal Converter","description":"\u003cp\u003eConfigured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro CON021\/916-120\u003c\/strong\u003e (\u003cstrong\u003eCON021\/916-120\u003c\/strong\u003e Eddy Current Signal Converter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard LMgSi 0.5 F22 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/916-120 converter utilizes a calibrated oscillator circuit to drive the transducer probe. To ensure linear response across the 12.0 mm extended measuring range, the system requires precise gap voltage validation. The operating range is centered on a target of -10 VDC, which corresponds to the median measurement gap between the sensor face and the shaft surface. Any deviation from this nominal gap voltage during static conditions indicates potential installation misalignment or transducer degradation, impacting the converter's ability to accurately linearize the output signal.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021\/916-120 be used with standard PR6424 probes or is it limited to the PR6426?\u003c\/p\u003e\n\u003cp\u003eA: The converter is optimized for specific transducer characteristics. Ensure the connected probe's impedance matches the calibration profile of the converter to prevent linearity errors exceeding the specified 1.5%.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP20 protection class suitable for direct installation on the turbine skid?\u003c\/p\u003e\n\u003cp\u003eA: The IP20 rating requires the converter to be mounted within a protective enclosure or junction box to prevent exposure to moisture, dust, and conductive debris.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the converter housing using four M5x20 screws, ensuring a clean electrical path to the machine ground.\u003c\/li\u003e\n\u003cli\u003eUtilize the self-locking Lemo-plug for the transducer connection, ensuring it is fully seated to prevent intermittent signal noise.\u003c\/li\u003e\n\u003cli\u003eTerminate the supply and output wiring using high-quality ferrules for the screw terminals, ensuring the wire gauge does not exceed 1.5 mm².\u003c\/li\u003e\n\u003cli\u003eVerify the power supply polarity (negative logic) before applying -23 VDC to -32 VDC, as incorrect polarity may result in permanent damage to the internal circuitry.\u003c\/li\u003e\n\u003cli\u003eShield all output signal leads and ground the shield at the monitoring system end only to mitigate 50\/60 Hz electromagnetic noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008972972341,"sku":"CON021\/916-120","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120__1_996e2d2b-8a35-4b28-9d02-5ee3b66c03af.png?v=1781680275"},{"product_id":"emerson-epro-pr6426-010-110-con021-916-120-eddy-current-system","title":"Emerson Epro PR6426\/010-110 \u0026 CON021\/916-120 Eddy Current System","description":"\u003cp\u003eConfigured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6426\/010-110\u003c\/strong\u003e (Sensor) coupled with the \u003cstrong\u003eCON021\/916-120\u003c\/strong\u003e (Signal Converter) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6426\/010-110 + CON021\/916-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.35 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe and converter housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe PR6426\/010-110 transducer probe, paired with the CON021\/916-120 converter, utilizes an oscillator circuit to drive the eddy current field. To ensure linear response across the 12.0 mm extended measuring range, the system requires precise gap voltage validation. The operating range is centered on a target of -10 VDC, which corresponds to the median measurement gap between the sensor face and the conductive target. Any deviation from this nominal gap voltage during static conditions indicates potential installation misalignment or transducer degradation, which directly affects the converter's ability to linearize the output signal.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the PR6426\/010-110 probe interchangeable with other Epro converter models?\u003c\/p\u003e\n\u003cp\u003eA: No. The transducer and converter are calibrated as a matched set. Replacing one without re-calibration of the entire loop will result in significant linearity errors exceeding the specified 1.5%.\u003c\/p\u003e\n\u003cp\u003eQ: Can the converter be installed in a high-vibration zone near the turbine?\u003c\/p\u003e\n\u003cp\u003eA: The converter is rated for 5g vibration at 60 Hz. However, it must be mounted within an IP20-compliant enclosure if the environment contains moisture, conductive dust, or oil mist.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the PR6426 transducer probe into a rigid bracket, ensuring at least 15 mm clearance from adjacent metallic surfaces to prevent cross-talk.\u003c\/li\u003e\n\u003cli\u003eSecure the Lemo-plug connector to the converter, verifying the self-locking mechanism is engaged.\u003c\/li\u003e\n\u003cli\u003eTerminate the -23 VDC to -32 VDC supply and output wiring using ferrules on the converter's screw terminals.\u003c\/li\u003e\n\u003cli\u003eVerify correct output polarity (negative logic) before full system activation to prevent internal electronic fault.\u003c\/li\u003e\n\u003cli\u003eGround the system shield only at the monitoring system (DCS\/TSI) rack to prevent ground loops and high-frequency electrical noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008979951925,"sku":"CON021\/916-120+PR6426\/010-110","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120__1_e93a0dde-ff63-4e49-978c-ee339b9222aa.png?v=1781680537"},{"product_id":"con021-916-160-epro-eddy-current-signal-converter","title":"CON021\/916-160 | EPRO | Eddy Current Signal Converter","description":"\u003cp\u003eConfigured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEPRO CON021\/916-160\u003c\/strong\u003e (\u003cstrong\u003eCON021\/916-160\u003c\/strong\u003e) Eddy Current Signal Converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal loop-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog\u003c\/td\u003e\n\u003ctd\u003ePR6426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/916-160 converter utilizes an oscillator circuit to drive the eddy current transducer probe. To ensure a linear response, the system requires precise gap voltage validation. The operating range is typically centered on a target of -10 VDC, which corresponds to the median measurement gap between the sensor face and the conductive target. Any deviation from this nominal gap voltage during static conditions indicates potential installation misalignment or transducer degradation, which directly affects the converter's ability to linearize the output signal.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CON021\/916-160 compatible with other EPRO probe models?\u003c\/p\u003e\n\u003cp\u003eA: The converter is calibrated as part of a matched system (PR6426 series). Use with non-specified transducers will result in measurement non-linearity and loss of accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Does this converter support field adjustment of the output offset?\u003c\/p\u003e\n\u003cp\u003eA: Internal calibration settings are factory-set. Field adjustments are limited to mechanical gap positioning to achieve the nominal -10 VDC center-gap voltage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the converter within an IP20-compliant enclosure to protect the internal circuitry from moisture and conductive dust.\u003c\/li\u003e\n\u003cli\u003eEnsure the transducer probe is installed in a rigid bracket, maintaining at least 15 mm of clearance from other metallic objects to avoid cross-talk.\u003c\/li\u003e\n\u003cli\u003eVerify that the cable connections are secure; the Lemo-plug or screw terminals must be tightened to prevent intermittent signal noise.\u003c\/li\u003e\n\u003cli\u003eGround the signal cable shield at the monitoring system (DCS\/TSI) rack only to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eConfirm the power supply polarity is correct before energizing the loop to prevent internal electronic fault.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008983687477,"sku":"CON021\/916-160","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426010-140_CON011916-1202_58c9c285-2603-49a4-86dc-4c34ab20d454.png?v=1781680637"},{"product_id":"epro-con021-916-200-eddy-current-signal-converter","title":"EPRO CON021\/916-200 Eddy Current Signal Converter","description":"\u003cp\u003eConfigured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEPRO CON021\/916-200\u003c\/strong\u003e (\u003cstrong\u003eCON021\/916-200\u003c\/strong\u003e) Eddy Current Signal Converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard LMgSi 0.5 F22 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e20.0 mm (Extended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/916-200 utilizes a high-frequency oscillator to drive the PR6426 transducer probe. To ensure accurate linearization over the 20.0 mm measuring range, the system necessitates precise gap voltage validation. The converter centers its output characteristic around a nominal target of -10 VDC, which represents the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory during static commissioning; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CON021\/916-200 compatible with standard PR6424 probes?\u003c\/p\u003e\n\u003cp\u003eA: No. This converter is specifically calibrated for the PR6426 extended range transducer. Mismatched probe\/converter pairs will result in non-linear signal response and increased measurement error beyond the 2.5% specification.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation requirements for the IP20 housing?\u003c\/p\u003e\n\u003cp\u003eA: The IP20 protection class mandates installation within a secondary protective enclosure or control cabinet to prevent exposure to moisture, oil mist, or conductive metallic dust common in turbomachinery environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the converter housing using four M5x20 screws onto a rigid, grounded surface to ensure structural integrity and chassis bonding.\u003c\/li\u003e\n\u003cli\u003eTerminate the supply and output wiring using high-quality wire-end sleeves on the screw terminals, ensuring no stray strands exist that could cause short-circuits.\u003c\/li\u003e\n\u003cli\u003eVerify the -23 VDC to -32 VDC power supply polarity before applying voltage, as incorrect polarity will damage the internal oscillator stage.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded, twisted-pair cabling for the output signal, terminating the shield exclusively at the monitoring system (DCS\/TSI) input to prevent ground-loop injection of 50\/60 Hz noise.\u003c\/li\u003e\n\u003cli\u003eInspect the transducer Lemo-plug connection to confirm the self-locking mechanism is fully engaged and free of surface oxidation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008985850165,"sku":"CON021\/916-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426010-140_CON011916-1202_52f97fae-188d-4c61-8ac2-c9d1c50349bd.png?v=1781680867"},{"product_id":"epro-con021-916-240-pr6426-010-140-eddy-current-sensor-system","title":"Epro CON021\/916-240 \u0026 PR6426\/010-140 Eddy Current Sensor System","description":"\u003cp\u003eConfigured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEpro CON021\/916-240\u003c\/strong\u003e (\u003cstrong\u003eCON021\/916-240\u003c\/strong\u003e) converter paired with the \u003cstrong\u003ePR6426\/010-140\u003c\/strong\u003e (\u003cstrong\u003ePR6426\/010-140\u003c\/strong\u003e) transducer provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-240 + PR6426\/010-140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEpro (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.92 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe and LMgSi 0.5 F22 converter housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +175 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -21 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e24.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 1.5 % (Sensor sensitivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC or -2 VDC to -18 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe. To ensure accurate linearization over the 24.0 mm extended measuring range, the system necessitates precise gap voltage validation. The converter centers its output characteristic around a nominal target of -10 VDC, which represents the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory during static commissioning; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021\/916-240 converter be used with shorter range sensors?\u003c\/p\u003e\n\u003cp\u003eA: No. The converter is calibrated specifically for the 24.0 mm range of the PR6426 series. Using a different transducer will result in significant linearity errors exceeding the specified 3.5% threshold.\u003c\/p\u003e\n\u003cp\u003eQ: Is the system capable of operating in pressurized environments?\u003c\/p\u003e\n\u003cp\u003eA: The PR6426 sensor head is rated for pressure resistance up to 6,500 hPa (94 psi). Ensure the installation threads are sealed appropriately for the application pressure environment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the converter housing using four M5x20 screws onto a rigid, grounded surface to ensure structural integrity.\u003c\/li\u003e\n\u003cli\u003eInstall the PR6426 probe into the mounting bracket, ensuring at least 200 mm shaft diameter clearance and adequate spacing from adjacent metallic structures to prevent cross-talk.\u003c\/li\u003e\n\u003cli\u003eTerminate the supply and output wiring using high-quality wire-end sleeves on the screw terminals, ensuring the cable conductor size does not exceed 1.5 mm².\u003c\/li\u003e\n\u003cli\u003eVerify the power supply polarity before applying voltage, as the unit requires -21 VDC to -32 VDC negative logic input.\u003c\/li\u003e\n\u003cli\u003eGround the signal cable shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop injection of 50\/60 Hz electromagnetic noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008986374453,"sku":"CON021\/916-240+PR6426\/010-140","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_582d0297-5c38-4450-8e7b-504ddb36276b.png?v=1781683345"},{"product_id":"emerson-epro-pr6423-000-031-cn-eddy-current-sensor","title":"Emerson Epro PR6423\/000-031-CN Eddy Current Sensor","description":"\u003cp\u003eConfigured for non-contact displacement measurement in machine monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/000-031-CN\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/000-031-CN\u003c\/strong\u003e) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/000-031-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Gap\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe PR6423\/000-031-CN utilizes electromagnetic induction to provide a linear output proportional to the target distance. The Incremental Scale Factor (ISF) is calibrated to 8 V\/mm (+\/- 5%) at nominal operating temperatures to ensure compatibility with standard Epro monitoring modules. Precise gap voltage validation is required during initial commissioning to confirm the probe operates within its linear measurement region, typically targeting a mid-range -10 VDC baseline relative to the signal converter output. Deviations from this scaling indicate potential mechanical misalignment or target material inconsistency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PEEK sensor tip require specific handling precautions during installation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. While PEEK provides excellent thermal and mechanical stability, avoid using metal-jawed wrenches directly on the tip to prevent surface scarring, which can introduce signal noise.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP66 rating applicable to the cable and connector assembly?\u003c\/p\u003e\n\u003cp\u003eA: The IP66 rating applies to the sensor head. The connector assembly requires additional environmental protection if exposed to direct fluid ingress or high-pressure washdown in the field.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the sensor in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum shaft diameter of 25 mm for the target area to ensure linear flux density.\u003c\/li\u003e\n\u003cli\u003eEnsure the initial air gap is set to 0.5 mm using a non-metallic feeler gauge to prevent damage to the probe tip.\u003c\/li\u003e\n\u003cli\u003eRoute the PTFE-insulated cable through grounded metallic conduit, keeping the lead away from high-current AC power lines to minimize induced electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTighten the lock nuts according to standard mechanical torque specifications for the stainless steel housing to prevent loosening under operational vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009088086325,"sku":"PR6423\/000-031-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_fd862823-a890-4e52-93ef-c49468612876.png?v=1781683691"},{"product_id":"emerson-epro-con021-pr6423-001-011-cn-eddy-current-sensor-system","title":"Emerson Epro CON021 \u0026 PR6423\/001-011-CN Eddy Current Sensor System","description":"\u003cp\u003eConfigured for high-precision displacement and vibration measurement in industrial turbomachinery, the \u003cstrong\u003eEmerson Epro CON021\u003c\/strong\u003e signal converter paired with the \u003cstrong\u003ePR6423\/001-011-CN\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/001-011-CN\u003c\/strong\u003e) transducer provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021 + PR6423\/001-011-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.35 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66 (Sensor head)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-current Probe Scaling\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes electromagnetic induction to provide a linear output proportional to the target distance. The Incremental Scale Factor (ISF) is calibrated to 8 V\/mm (+\/- 5%) at nominal operating temperatures to ensure compatibility with standard Epro monitoring modules. Precise gap voltage validation is required during initial commissioning to confirm the probe operates within its linear measurement region, typically targeting a mid-range -10 VDC baseline relative to the signal converter output. Deviations from this scaling indicate potential mechanical misalignment or target material inconsistency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021 signal converter be used with other Epro PR642x series probes?\u003c\/p\u003e\n\u003cp\u003eA: The converter is calibrated as part of a matched system. Replacing the transducer probe requires checking the calibration certificate to ensure that the ISF and linearity error specifications remain within system tolerances.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP66 rating maintained if the cable is cut or spliced?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP66 rating applies to the factory-sealed sensor head and cable assembly. Any field splicing compromises the integrity of the seal, potentially allowing fluid ingress into the sensor tip.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the PR6423 sensor in a rigid bracket, ensuring at least 25 mm shaft diameter clearance to prevent signal flux interference.\u003c\/li\u003e\n\u003cli\u003eVerify the initial air gap is set to 0.5 mm using a non-metallic feeler gauge to prevent contact-induced tip damage.\u003c\/li\u003e\n\u003cli\u003eTerminate the converter signal output using shielded twisted-pair cabling; the shield should be grounded only at the monitoring system rack to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eRoute the PTFE cable through metallic conduit, ensuring the cable bend radius does not exceed the manufacturer's recommendation to prevent internal conductor stress.\u003c\/li\u003e\n\u003cli\u003eInspect all mechanical threads for burrs or contaminants prior to installation to ensure a flush mount against the housing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009095885109,"sku":"CON021+PR6423\/001-011-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_cc84272c-8670-41dd-abfd-10962d0f5145.png?v=1781683849"},{"product_id":"pr6423-002-030-con021-eddy-current-sensor-emerson-epro","title":"PR6423\/002-030 \u0026 CON021 Eddy Current Sensor | Emerson Epro","description":"\u003cp\u003eConfigured for high-precision displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/002-030\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/002-030\u003c\/strong\u003e Eddy Current Sensor) coupled with the \u003cstrong\u003eCON021\u003c\/strong\u003e converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/002-030 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.22 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the eddy current transducer probe. To ensure accurate linearization over the 2.0 mm measuring range, the system necessitates precise gap voltage validation. The converter centers its output characteristic around a nominal target of -10 VDC, which represents the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory during static commissioning; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021 converter be used with different Epro PR642x series probes?\u003c\/p\u003e\n\u003cp\u003eA: The converter is calibrated as part of a matched system. Replacing the transducer probe requires checking the calibration certificate to ensure that the Incremental Scale Factor (ISF) and linearity error specifications remain within system tolerances.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP66 rating maintained if the cable is cut or spliced during field installation?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP66 rating applies to the factory-sealed sensor head and cable assembly. Any field splicing or modification compromises the environmental integrity of the seal, potentially allowing fluid ingress into the sensor tip.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the sensor in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum shaft diameter of 25 mm for the target area to ensure linear flux density and accurate readings.\u003c\/li\u003e\n\u003cli\u003eEnsure the initial air gap is set to 0.5 mm using a non-metallic feeler gauge to prevent contact-induced tip damage during operation.\u003c\/li\u003e\n\u003cli\u003eRoute the PTFE-insulated cable through grounded metallic conduit, keeping the lead away from high-current AC power lines to minimize induced electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eInspect all mechanical threads for burrs or contaminants prior to installation to ensure a flush mount against the housing, preventing resonance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009099325749,"sku":"CON021+PR6423\/002-030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_8eb573e7-99f8-425a-8f69-8f272405e3de.png?v=1781683998"},{"product_id":"emerson-epro-pr6423-003-040-con021-eddy-current-displacement-transducer","title":"Emerson Epro PR6423\/003-040 \u0026 CON021 Eddy Current Displacement Transducer","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in machine monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/003-040\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/003-040\u003c\/strong\u003e Eddy Current Displacement Transducer) coupled with the \u003cstrong\u003eCON021\u003c\/strong\u003e converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/003-040 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe and converter housing geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (static: +\/- 1.0 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Gap\u003c\/td\u003e\n\u003ctd\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, generating a high-frequency electromagnetic field. To ensure output linearity, the system necessitates precise gap voltage validation during commissioning. The converter is designed to center its output around a nominal -10 VDC target, corresponding to the 1.5 mm center gap. Maintenance of this baseline is required for accurate tracking of shaft radial vibration and axial position. Deviations from the -10 VDC nominal gap voltage indicate potential installation misalignment, transducer saturation, or degradation of the conductive target surface, which must be addressed to prevent signal distortion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this sensor be used on shafts with non-ferromagnetic materials?\u003c\/p\u003e\n\u003cp\u003eA: The sensitivity and linearity are calibrated for electrically conducting steel. Usage on materials with different electrical conductivity or magnetic permeability will require a recalibration of the signal converter's sensitivity factor.\u003c\/p\u003e\n\u003cp\u003eQ: How does shaft diameter affect the measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eA: A minimum shaft diameter of 25 mm is required to maintain the specified flux density. If the shaft diameter is smaller, the sensor output will exhibit non-linearities and reduced sensitivity compared to the factory calibration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting bracket is rigid to prevent mechanical resonances from influencing the transducer output.\u003c\/li\u003e\n\u003cli\u003eInstall the probe at the 1.5 mm nominal gap using a non-conductive feeler gauge to avoid damaging the sensor tip.\u003c\/li\u003e\n\u003cli\u003eVerify that the shaft surface at the measurement location is free of scratches, burrs, or non-conductive coatings.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current power cables to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround the system shield exclusively at the monitoring system (DCS\/TSI) rack to prevent ground-loop current injection into the sensor signal.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009101947189,"sku":"CON021+PR6423\/003-040","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_26872261-47f1-4ca5-981e-7ada3653a97a.png?v=1781684137"},{"product_id":"pr6423-003-130-con021-emerson-epro-eddy-current-sensor","title":"PR6423\/003-130 \u0026 CON021 | Emerson Epro | Eddy Current Sensor","description":"\u003cp\u003eConfigured for high-precision displacement and vibration monitoring in turbomachinery, the \u003cstrong\u003eEmerson Epro PR6423\/003-130\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/003-130\u003c\/strong\u003e Eddy Current Sensor) coupled with the \u003cstrong\u003eCON021\u003c\/strong\u003e converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/003-130 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Gap\u003c\/td\u003e\n\u003ctd\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021 converter be used with different probe types?\u003c\/p\u003e\n\u003cp\u003eA: The CON021 is calibrated as a matched system with specific PR6423 series probes. Interchangeability with other probe ranges will result in linearity errors and incorrect sensitivity scaling.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP66 protection rating applicable to the connector interface?\u003c\/p\u003e\n\u003cp\u003eA: The IP66 rating applies to the sensor head and cable assembly. The electrical connector is typically rated for protected environments; ensure appropriate environmental shielding if installed in areas prone to high-pressure fluid exposure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eSet the nominal air gap at 1.5 mm using a non-metallic feeler gauge to prevent contact damage to the PEEK sensor tip.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system rack only to prevent ground-loop current injection.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009104929077,"sku":"CON021+PR6423\/003-130","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6423003-130.png?v=1781684347"},{"product_id":"pr6423-00m-030-con021-eddy-current-sensor-system-emerson-epro","title":"PR6423\/00M-030 \u0026 CON021 Eddy Current Sensor System | Emerson Epro","description":"\u003cp\u003eConfigured for high-speed vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/00M-030\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/00M-030\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e (\u003cstrong\u003eCON021\u003c\/strong\u003e) signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/00M-030 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.35 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -21 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eDC to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CON021 support hot-swap replacement?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 signal converter is designed to support hot-swap replacement within compatible monitoring racks, such as the MMS 6000 and IMR 6000 series, without requiring full system downtime.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP20 rating suitable for direct installation on the turbine skid?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP20 protection class mandates installation within a protective enclosure, control cabinet, or junction box to prevent exposure to moisture, oil mist, or conductive metallic debris.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal wiring using high-quality ferrules on the screw terminals, ensuring the wire gauge does not exceed 1.5 mm².\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround the signal cable shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009109156149,"sku":"CON021+PR6423\/00M-030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120__1_8570f91c-4247-4ad0-bff0-39b70f9b810a.png?v=1781684651"},{"product_id":"emerson-epro-pr6423-00r-010-eddy-current-sensor","title":"Emerson Epro PR6423\/00R-010 Eddy Current Sensor","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/00R-010\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/00R-010\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/00R-010 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.10 kg (Sensor with 1 m cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eM10x1 or 3\/8-24 UNF thread variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021 signal converter be interchanged with other Epro PR642x probe ranges?\u003c\/p\u003e\n\u003cp\u003eA: No. The converter is factory-calibrated for the specific Incremental Scale Factor (ISF) of the matched probe. Using a different probe range will result in measurement non-linearity exceeding the specified 0.025 mm Deviation from Best Fit Straight Line (DsL).\u003c\/p\u003e\n\u003cp\u003eQ: Is the PEEK sensor tip susceptible to thermal deformation?\u003c\/p\u003e\n\u003cp\u003eA: The PEEK material used for the sensor tip is rated for continuous operation up to +200 deg C. However, direct contact with the measurement target must be avoided to prevent mechanical abrasion or thermal shock, which can alter the probe's electromagnetic signature.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eSet the nominal air gap at 0.5 mm using a non-metallic feeler gauge to prevent contact damage to the sensor tip.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009116397877,"sku":"CON021+PR6423\/00R-010","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_73a136c9-0314-4616-bd8a-a490e57d92ab.png?v=1781684902"},{"product_id":"pr6423-00r-010-cn-con021-emerson-epro-eddy-current-sensor-system","title":"PR6423\/00R-010-CN \u0026 CON021 | Emerson Epro | Eddy Current Sensor System","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/00R-010-CN\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/00R-010-CN\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e (\u003cstrong\u003eCON021\u003c\/strong\u003e) signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/00R-010-CN + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.23 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -21 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CON021 support hot-swap replacement in a rack system?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 signal converter is designed for integration into monitoring racks where it supports replacement while the system is energized, provided the rack backplane architecture supports hot-swapping.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP20 rating of the CON021 suitable for direct skid mounting?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP20 protection class mandates installation within a protective enclosure, control cabinet, or junction box to prevent exposure to environmental contaminants, moisture, or metallic debris.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eTerminate signal wiring using high-quality ferrules on the screw terminals, ensuring the wire gauge does not exceed 1.5 mm².\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eGround the signal cable shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009122754869,"sku":"CON021+PR6423\/00R-010-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6423003-130_94b4004e-2a9d-4f57-9e55-fd9e3eaec9cb.png?v=1781685101"},{"product_id":"emerson-epro-pr6423-00r-030-con021-eddy-current-displacement-system","title":"Emerson Epro PR6423\/00R-030 \u0026 CON021 Eddy Current Displacement System","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eConfigured for high-frequency displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/00R-030\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/00R-030\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e (\u003cstrong\u003eCON021\u003c\/strong\u003e) signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/00R-030 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.28 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eM10x1 or 3\/8-24 UNF thread variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CON021 support hot-swap replacement in a monitoring rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 is designed to support hot-swap replacement within compatible monitoring architectures without requiring full system power-down, provided the backplane configuration permits.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 8 mm probe tip material suitable for high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eA: The probe tip is constructed from PEEK, which maintains structural integrity and electrical characteristics within specified high-temperature industrial operating ranges. Ensure the air gap is maintained during thermal expansion of the rotor to prevent tip contact.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eSet the nominal air gap at 0.5 mm using a non-metallic feeler gauge to prevent contact damage to the sensor tip.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009126195509,"sku":"CON021+PR6423\/00R-030","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_03abe67d-8421-49f3-8fcf-35c682c28627.png?v=1781685327"},{"product_id":"pr6423-010-000-cn-con021-emerson-epro-eddy-current-sensor","title":"PR6423\/010-000-CN \u0026 CON021 | Emerson Epro | Eddy Current Sensor","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/010-000-CN\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/010-000-CN\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/010-000-CN + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.25 kg (Combined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 8 mm probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e8 mm Eddy Current Non-contact Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PR6423 series support hot-swap replacement of the CON021 converter?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 converter is designed for installation within monitoring racks that support hot-swapping functionality without requiring a full system shutdown, provided the rack backplane infrastructure is configured for such operations.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe tip material impact measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eA: The probe tip is constructed for stability in harsh environments. Measurement accuracy relies on the conductive properties of the target shaft; ensure the target material composition matches the calibration specifications of the converter to prevent non-linearity errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eSet the nominal air gap using a non-metallic feeler gauge to prevent contact damage to the sensor tip during operation.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009130848565,"sku":"CON021+PR6423\/010-000-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_5f676556-0eac-4592-ac17-3ac462c87a04.png?v=1781685466"},{"product_id":"epro-pr6423-010-020-cn-con021-eddy-current-sensors","title":"Epro PR6423\/010-020-CN \u0026 CON021 Eddy Current Sensors","description":"\u003cp\u003eConfigured for non-contact measurement of static and dynamic shaft displacement in rotating machinery, the \u003cstrong\u003eEpro PR6423\/010-020-CN\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/010-020-CN\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e (\u003cstrong\u003eCON021\u003c\/strong\u003e) signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/010-020-CN + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEpro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17 cm x 8 cm x 23.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this system compatible with field-replacement of the probe cable?\u003c\/p\u003e\n\u003cp\u003eA: The PR6423 series utilizes a factory-calibrated probe and cable assembly. Replacing or splicing the cable in the field will alter the impedance characteristics of the oscillator circuit, requiring recalibration to maintain the specified measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CON021 converter be installed in high-vibration areas?\u003c\/p\u003e\n\u003cp\u003eA: The converter must be installed in an environment that complies with vibration specifications provided in the installation manual. If installed on a machine casing, ensure a rigid, vibration-isolated cabinet or enclosure is utilized to prevent signal noise and mechanical stress on the backplane connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eEstablish the nominal air gap using a non-metallic feeler gauge to prevent contact damage to the sensor tip during startup.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009132781877,"sku":"CON021+PR6423\/010-020-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_2caeaabc-9936-47bc-9b08-1e90b12da890.png?v=1781685716"},{"product_id":"emerson-epro-pr6423-010-040-con021-eddy-current-sensor","title":"Emerson EPRO PR6423\/010-040 \u0026 CON021 Eddy Current Sensor","description":"\u003cp\u003eConfigured for critical turbomachinery proximity monitoring within Turbine Supervisory Instrumentation (TSI) platforms, the \u003cstrong\u003eEmerson EPRO PR6423\/010-040\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/010-040\u003c\/strong\u003e) Eddy Current Displacement Transducer provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/010-040 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ International\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +125 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe transducer system utilizes an alternating RF magnetic field to induce eddy currents into a rotating target shaft, mapping exact structural changes in the magnetic field envelope without physical contact. The combined CON021 signal converter drive stage performs continuous eddy-current probe scaling to convert high-frequency impedance fluctuations into precise analog metrics.\u003c\/p\u003e\n\u003cp\u003eDuring calibration loops, field technicians execute gap voltage validation against standard -10 VDC targets to confirm the probe tip sits exactly in the middle of its linear voltage-to-distance slope. This real-time calibration enables accurate tracking of complex rotor dynamics—such as oil whirl, shaft centerline position, and axial thrust migration—in high-speed turbomachinery. The internal driver circuits utilize cross-talk suppression filters to isolate adjoining sensor signals, ensuring clean data delivery over long cable runs without adjacent channel interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the mechanical significance of the -10 VDC gap voltage target during system setup?\u003c\/p\u003e\n\u003cp\u003eA: A -10 VDC gap voltage indicates that the sensor tip is positioned exactly at the physical midpoint of its +\/- 2 mm linear measuring range. This provides the internal processing circuit with equal headroom to track both positive and negative dynamic shaft displacements.\u003c\/p\u003e\n\u003cp\u003eQ: Can the PR6423\/010-040 sensor tip be exposed directly to lubricating oil fields inside a turbine housing?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The sensor tip and matching high-frequency extension cable assemblies are hermetically sealed and constructed from oil-resistant polymers designed to withstand continuous submersion in hot industrial lubricants without degradation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThreaded Probe Penetration Adjustment: Thread the PR6423 probe into the machine casing bracket while checking the dynamic DC voltage at the CON021 driver terminals. Stop rotating the probe when the multimeter registers the calibrated target gap voltage.\u003c\/li\u003e\n\u003cli\u003eLow-Impedance Coaxial Connectors Insulation: Clean all miniature coaxial cable links with a residue-free electronics cleaner before final assembly. Wrap the mated connectors in non-conductive insulation sleeves to block physical contact with structural machine grounding paths.\u003c\/li\u003e\n\u003cli\u003eSignal Cable Path Isolation: Route the dynamic signal lines from the CON021 module through flexible, liquid-tight grounded metal conduit. Maintain physical separation from heavy AC motor lines and internal switchgear cables to prevent external high-frequency electrical noise injection.\u003c\/li\u003e\n\u003cli\u003eLocknut Tension Verification: Once the target gap setting is validated, tighten the secondary mechanical chassis locknut firmly against the machine exterior panel to prevent the threaded probe body from backing out under heavy operational vibrations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009137369397,"sku":"CON021+PR6423\/010-040","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_2d550136-26cd-4118-b449-9b6ce2ad1786.png?v=1781685929"},{"product_id":"emerson-epro-pr6423-011-110-cn-con021-eddy-current-sensor-system","title":"Emerson Epro PR6423\/011-110-CN \u0026 CON021 Eddy Current Sensor System","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/011-110-CN\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/011-110-CN\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/011-110-CN + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C (Converter); -35 deg C to +180 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e-23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CON021 signal converter support hot-swap replacement in a monitoring rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 is designed for integration into monitoring racks where it supports replacement while the system is energized, provided the rack backplane architecture supports hot-swapping.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP20 rating of the CON021 suitable for direct skid mounting?\u003c\/p\u003e\n\u003cp\u003eA: No. The IP20 protection class mandates installation within a protective enclosure, control cabinet, or junction box to prevent exposure to environmental contaminants, moisture, or metallic debris.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eSet the nominal air gap at 0.5 mm using a non-metallic feeler gauge to prevent contact damage to the sensor tip.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009140220213,"sku":"CON021+PR6423\/011-110-CN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6423003-130_723cf87b-8581-4348-86c8-64e82acedebb.png?v=1781686173"},{"product_id":"pr6423-012-130-con021-emerson-epro-eddy-current-sensor-system","title":"PR6423\/012-130 \u0026 CON021 | Emerson Epro | Eddy Current Sensor System","description":"\u003cp\u003eConfigured for high-frequency displacement measurement in turbomachinery monitoring systems, the \u003cstrong\u003eEmerson Epro PR6423\/012-130\u003c\/strong\u003e (\u003cstrong\u003ePR6423\/012-130\u003c\/strong\u003e) transducer paired with the \u003cstrong\u003eCON021\u003c\/strong\u003e signal converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6423\/012-130 + CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard probe housing and converter geometry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C (Converter); -35 deg C to +200 deg C (Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e-23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes an oscillator circuit to drive the transducer probe, creating an electromagnetic field for displacement detection. To ensure accurate linearization, the system necessitates precise gap voltage validation during commissioning. The converter centers its output characteristic around a nominal target of -10 VDC, representing the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory for accurate signal tracking; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CON021 signal converter support hot-swap replacement in a monitoring rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CON021 is designed for integration into monitoring racks where it supports replacement while the system is energized, provided the rack backplane architecture supports hot-swapping.\u003c\/p\u003e\n\u003cp\u003eQ: How does the initial air gap setting affect system accuracy?\u003c\/p\u003e\n\u003cp\u003eA: The system is calibrated for an initial air gap of 0.5 mm. Maintaining this mechanical gap is mandatory to ensure the probe operates within the linear portion of its voltage-to-distance characteristic curve.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the transducer in a rigid, vibration-isolated bracket to minimize extraneous mechanical noise and prevent housing fatigue.\u003c\/li\u003e\n\u003cli\u003eEnsure the measurement target surface is clean and free of non-conductive coatings to maintain the required electrical conductivity.\u003c\/li\u003e\n\u003cli\u003eSet the nominal air gap at 0.5 mm using a non-metallic feeler gauge to prevent contact damage to the sensor tip.\u003c\/li\u003e\n\u003cli\u003eRoute signal cabling through grounded metallic conduit, keeping lines physically separated from high-current AC power lines to mitigate electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate the signal shield at the monitoring system (DCS\/TSI) rack only to prevent ground-loop current injection into the converter circuit.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53009142251829,"sku":"CON021+PR6423\/012-130","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120_1cad6f2c-e581-44fc-b678-65cb5fec6156.png?v=1781686372"}],"url":"https:\/\/www.5gplc.com\/collections\/emerson-epro.oembed?page=3\u0026type=grid","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}