{"title":"Allen-Bradley Point I\/O","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eAllen-Bradley Point I\/O\u003c\/strong\u003e\u003cspan\u003e modules deliver modular, scalable I\/O solutions for PLC systems. These modules simplify wiring, improve signal reliability, and enable flexible system expansion. Widely used in manufacturing and process industries, Point I\/O modules support efficient, maintainable, and robust automation solutions.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1734-adn-devicenet-i-o-adapter-module","title":"Allen-Bradley 1734-ADN | DeviceNet I\/O Adapter Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-ADN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance POINT I\/O DeviceNet adapter designed to connect distributed I\/O modules to DeviceNet networks. With support for up to 63 powered modules and a maximum of 504 I\/O points, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-ADN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures flexible and scalable control for industrial automation systems. Compact dimensions and low weight make it suitable for installation in dense control cabinets while providing reliable communication across the network.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Powered Modules\u003c\/strong\u003e: 63\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated I\/O Channels\u003c\/strong\u003e: 0\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum I\/O Points\u003c\/strong\u003e: 504\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Nodes (with max I\/O)\u003c\/strong\u003e: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNode Address\u003c\/strong\u003e: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Module Capacity\u003c\/strong\u003e: 63\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Current\u003c\/strong\u003e: 30 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e: 1000 mA @ 5 V DC ±5% (4.75–5.25 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (LxWxH)\u003c\/strong\u003e: 12.2 cm × 5.49 cm × 13.34 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable I\/O Support\u003c\/strong\u003e: Connects up to 63 POINT I\/O modules for flexible system expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh I\/O Density\u003c\/strong\u003e: Handles up to 504 I\/O points for comprehensive control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design\u003c\/strong\u003e: Lightweight and space-saving for dense cabinet installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeviceNet Integration\u003c\/strong\u003e: Reliable communication with DeviceNet networks, supporting one node per maximum I\/O configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Power Management\u003c\/strong\u003e: Low DeviceNet and POINTBus current consumption for energy-efficient operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-ADN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadapter is ideal for distributed I\/O configurations in process control, factory automation, and other industrial systems requiring reliable DeviceNet connectivity. It enables rapid expansion of POINT I\/O networks while maintaining precise control over large numbers of I\/O points.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many POINT I\/O modules can the 1734-ADN support?\u003c\/strong\u003e\u003cbr\u003eA: The module supports up to 63 powered POINT I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum number of I\/O points?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-ADN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan handle a total of 504 I\/O points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the required Node Address?\u003c\/strong\u003e\u003cbr\u003eA: When configured with maximum I\/O, the node address is 1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it operate in compact control cabinets?\u003c\/strong\u003e\u003cbr\u003eA: Yes, with dimensions of 12.2 × 5.49 × 13.34 cm and weight of 0.3 kg, it is suitable for tight installations.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52139795317045,"sku":"1734-ADN","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-ADN1.jpg?v=1767690795"},{"product_id":"1734-top3-allen-bradley-compact-i-o-terminal-base","title":"1734-TOP3 | Allen-Bradley | Compact I\/O Terminal Base","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TOP3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact terminal base designed for POINT I\/O modules. It serves as the mounting and connection platform for POINT I\/O modules, providing reliable signal routing, integrated diagnostics, and flexible installation options. Engineered for industrial automation, this terminal base supports modular expansion and easy maintenance in distributed control systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eModule Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TOP3\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Allen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: I\/O Terminal Base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible System\u003c\/strong\u003e: POINT I\/O series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical \u0026amp; Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Support\u003c\/strong\u003e: Supports multiple I\/O modules stacked on a single base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Termination\u003c\/strong\u003e: Screw-type or spring clamp connections (depending on submodule)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e: Designed to maintain signal integrity between I\/O modules and field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: Standard POINT I\/O footprint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 0.5 lb (0.23 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TOP3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal base is ideal for distributed control systems in manufacturing, process automation, and industrial monitoring. It enables quick module replacement, flexible wiring configurations, and compact installation in constrained control panels.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which I\/O modules are compatible with the 1734-TOP3?\u003c\/strong\u003e\u003cbr\u003eA: Compatible with Allen-Bradley POINT I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be mounted on a DIN rail?\u003c\/strong\u003e\u003cbr\u003eA: Yes, supports standard DIN rail mounting and panel installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support multiple modules stacked on one base?\u003c\/strong\u003e\u003cbr\u003eA: Yes, designed for modular stacking of POINT I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA: 0°C to 60°C (32°F to 140°F).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52140241977653,"sku":"1734-TOP3","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-TOP3.jpg?v=1767696533"},{"product_id":"allen-bradley-1734-aentr-point-i-o-ethernet-ip-adapter-module","title":"Allen-Bradley 1734-AENTR POINT I\/O EtherNet\/IP Adapter Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENTR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-port EtherNet\/IP adapter for POINT I\/O systems, enabling seamless integration of distributed I\/O modules into Ethernet networks. This module supports Device Level Ring (DLR) topology, allowing for ring, star, tree, and linear network configurations. It accommodates up to 63 POINTBus modules with 31 direct connections, providing flexible expansion for digital and analog I\/O in compact installations.\u003c\/p\u003e\n\u003cp\u003eDesigned for industrial reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENTR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 24 VDC operation, isolation, and reverse-polarity protection. Its open-style enclosure and -20 to 60 °C operating range make it suitable for both factory floors and control cabinets. This listing includes the adapter only; POINT I\/O modules must be purchased separately.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eModule Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENTR\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e: 1734-AENTR\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e: Allen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e: POINT I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e: EtherNet\/IP Adapter with Dual-Port DLR\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eNetworking \u0026amp; Topology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Network Speeds\u003c\/strong\u003e: 10\/100 Mbit\/s, half or full duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTopology Support\u003c\/strong\u003e: Ring, Star, Tree, Linear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum POINTBus Modules\u003c\/strong\u003e: 63\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Connections\u003c\/strong\u003e: 31\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Electrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Power Consumption\u003c\/strong\u003e: 10.4 W at 28.8 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e: 50 V continuous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e: Reverse-polarity protected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e: Open type\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -20 to 60 °C (-4 to 140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: Approx. 0.45 kg (1 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Warranty\u003c\/strong\u003e: Not applied\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded Warranty\u003c\/strong\u003e: Radwell 2-year warranty\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENTR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eadapter is ideal for machine-level control, material handling, and modular process skids. It supports redundant ring networking, enabling reliable communications in distributed I\/O setups.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many POINTBus modules can this adapter support?\u003c\/strong\u003e\u003cbr\u003eA: Up to 63 modules with 31 direct connections.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support Device Level Ring topology?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the dual RJ45 ports enable DLR configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the operating voltage?\u003c\/strong\u003e\u003cbr\u003eA: 24 VDC standard operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be mounted on a DIN rail?\u003c\/strong\u003e\u003cbr\u003eA: Yes, DIN rail mounting is supported.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52140245909813,"sku":"1734-AENTR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-AENTR.jpg?v=1767696871"},{"product_id":"allen-bradley-point-i-o-1734-ob4e-4-point-dc-output-module","title":"Allen-Bradley POINT I\/O 1734-OB4E 4-Point DC Output Module","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe Allen-Bradley\u003cstrong\u003e 1734-OB4E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a POINT I\/O 4-channel protected output module designed for compact distributed I\/O systems. It provides efficient, space-saving control of DC loads and is optimized for use in applications requiring high reliability, modularity, and easy field wiring. This module delivers robust sourcing outputs, onboard protection, and stable performance in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports four non-isolated sourcing outputs organized into one group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for 24V DC nominal operation, with voltage tolerance from\u003cspan\u003e \u003c\/span\u003e10V to 28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated protection against short circuits and overload conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow on-state voltage drop (≤0.2V DC) for energy-efficient operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact form factor suitable for POINT I\/O backplanes and distributed control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB4E\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O Protected Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 sourcing (1 group of 4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal (10V–28.8V DC range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Voltage Drop (Max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.2V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0 A per output; total module current ≤3.0 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 A for 10 ms, repeatable every 3 s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation (Max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.2 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.1 BTU\/hr @ 28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50V continuous (reinforced insulation, tested at 2500V DC for 60 s)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Base:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-TB or 1734-TBS terminal base assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.8 Nm (7 lb-in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeyswitch Position:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H×W×D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.55 × 1.2 × 5.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 60 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance and Design\u003c\/strong\u003e\u003cbr\u003eThe module features advanced short-circuit protection and thermal management to prevent field device damage. Its compact design supports easy installation and wiring within control cabinets while maintaining compatibility with the POINT I\/O platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachine control and automation panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and material handling equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed I\/O systems in process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy and building management control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of output configuration does the 1734-OB4E use?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module uses four non-isolated sourcing DC outputs grouped into a single channel block.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What kind of protection does it include?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt features built-in short-circuit and overcurrent protection, ensuring long-term reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What terminal base is compatible with this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt can be installed on 1734-TB or 1734-TBS base assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the maximum total current per module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe total current must not exceed 3.0 A across all outputs.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52154084655413,"sku":"1734-OB4E","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB4E.jpg?v=1767923622"},{"product_id":"allen-bradley-1734-ie2c-point-i-o-series-2-channel-input-module","title":"Allen-Bradley 1734-IE2C | POINT I\/O Series | 2-Channel Input Module","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 2-channel analog input module from the POINT I\/O series, designed for high-precision signal acquisition in distributed control systems. It enables accurate measurement of analog process variables such as voltage and current, allowing smooth data transmission between field sensors and PLCs. Engineered for compactness and reliability, this module is ideal for applications that require modularity, scalability, and space-efficient I\/O configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides two differential analog input channels for voltage or current signal measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact POINT I\/O form factor for distributed and modular automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports current and voltage input ranges including ±10V and 4–20mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeatures high-resolution A\/D conversion for precise data acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated calibration and diagnostics to ensure accuracy and easy maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable design for system flexibility and reduced downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 differential channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVoltage or current (configurable per channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±10V DC, 0–10V DC, 0–20mA, 4–20mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e13 bits (voltage\/current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 Ω (current), 1 MΩ (voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 ms typical per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (10–28.8V DC range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 W typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50V continuous, reinforced insulation (field to system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Base:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-TB or 1734-TBS terminal base assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H×W×D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.55 × 1.2 × 5.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 60 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Highlights\u003c\/strong\u003e\u003cbr\u003eThe 1734-IE2C ensures smooth integration with Allen-Bradley POINT I\/O and CompactLogix systems, enabling distributed control with reduced wiring complexity. Each input channel is individually configurable for different process signals, providing enhanced adaptability for diverse field instrumentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control and monitoring in manufacturing environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature, pressure, and flow signal acquisition from analog transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial machinery and test equipment data collection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment and environmental monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What signal types can the 1734-IE2C measure?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports both current and voltage inputs, including ±10V, 0–10V, 0–20mA, and 4–20mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many channels does the module have?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo differential input channels\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which terminal bases are compatible with this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt can be mounted on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebase assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can the module be replaced during system operation?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the POINT I\/O backplane.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52154219954485,"sku":"1734-IE2C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IE2C.jpg?v=1767924299"},{"product_id":"1734-ib4-allen-bradley-point-i-o-digital-input-module","title":"1734-IB4 | Allen-Bradley | POINT I\/O Digital Input Module","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IB4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact POINT I\/O digital input module featuring four sinking input channels designed for 24 V DC control systems. It provides reliable signal acquisition for distributed I\/O architectures, offering flexible mounting and simplified wiring through the POINT I\/O backplane. Its open-style housing and DIN-rail design make it ideal for use in tight control enclosures or modular installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour sinking digital input channels for 24 V DC logic signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact POINT I\/O format, optimized for distributed and modular automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-style housing with quick DIN-rail installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with 1734-TBS and 1734-TB terminal bases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow power draw and high input integrity for efficient control performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for integration with CompactLogix and ControlLogix platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IB4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O Sink Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 sinking inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital, 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 – 28.8 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current (Nominal):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.0 mA @ 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Delay (Typical):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0 ms ON \/ 1.0 ms OFF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 V continuous, reinforced insulation (field ↔ system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN-rail via 1734-TBS or 1734-TB base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Style:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 W (max.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.55 × 1.2 × 5.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 0.02 kg (0.04 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance and Reliability\u003c\/strong\u003e\u003cbr\u003eThe module is engineered for stable performance under continuous industrial operation. Each input channel provides fast response times and electrical isolation, ensuring dependable digital signal handling in PLC-based automation networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and material-handling equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine tools and assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilding and facility automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control and distributed I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of input signal does the 1734-IB4 accept?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports 24 V DC sinking digital inputs for on\/off signal detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module be installed while the system is running?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the POINT I\/O architecture allows hot-swapping for minimal downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which base assemblies are compatible with the 1734-IB4?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt mounts on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eterminal bases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the recommended operating voltage range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates between 10 V DC and 28.8 V DC, nominal 24 V DC.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52154313572661,"sku":"1734-IB4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IB4.jpg?v=1767924683"},{"product_id":"allen-bradley-1734-oe2c-2-point-analog-output-24v-dc","title":"Allen-Bradley 1734-OE2C | 2-Point Analog Output | 24V DC","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OE2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a two-channel analog current output module designed for the POINT I\/O distributed I\/O system. It enables precise analog signal generation for controlling actuators, drives, and other field devices that require current-based analog signals. With flexible configuration options, high accuracy, and compact size, it’s ideal for scalable automation applications that demand efficient analog control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTwo single-ended analog output channels, supporting 0–20 mA and 4–20 mA ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh precision output with ±0.1% full-scale accuracy at 25°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular POINT I\/O design, allowing seamless integration with other POINT modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in status LEDs for module, network, and output diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail mountable, supports 1734-TB, 1734-TBS, 1734-TB3, and 1734-TB3S base assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with POINT I\/O adapters for various network protocols (EtherNet\/IP, DeviceNet, ControlNet, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O Analog Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 single-ended, current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–20 mA \/ 4–20 mA (configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e13 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.1% Full Scale at 25°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026lt; 2 ms per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC nominal (10–28.8 V range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.6 W typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 V continuous, reinforced insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Module Status (green\/red)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Network Status (green\/red)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 × Output Status (green\/red)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Base:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-TB, 1734-TBS, 1734-TB3, 1734-TB3S\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H×W×D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.55 × 1.2 × 5.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApprox. 60 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance and Reliability\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers precise analog current signals for process control, ensuring stability and repeatability even in electrically noisy environments. Its modular structure simplifies installation, maintenance, and future system expansion without rewiring the control cabinet.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control for flow, level, and pressure systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog control of drives, valves, and actuators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed I\/O in machine automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with CompactLogix and ControlLogix controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What types of output signals does the 1734-OE2C support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports configurable 0–20 mA and 4–20 mA analog current outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can it be used with voltage-based devices?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The module is designed specifically for current signal outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which wiring bases are compatible?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt works with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB3\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB3S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebase assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Does it include isolation between channels?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the outputs are non-isolated single-ended channels.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52154401259829,"sku":"1734-OE2C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OE2C.jpg?v=1767924912"},{"product_id":"allen-bradley-1734-oa4-120-220v-ac-output-point-i-o-series","title":"Allen-Bradley 1734-OA4 | 120\/220V AC Output | POINT I\/O Series","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OA4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-channel AC output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the POINT I\/O family, engineered for flexible distributed control applications. Designed for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120\/220V AC systems\u003c\/strong\u003e, this module delivers reliable sourcing outputs and integrates seamlessly with POINTBus architecture for modular control expansion. Its reinforced insulation and high surge tolerance ensure dependable operation in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour non-isolated, sourcing outputs for AC control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide on-state voltage range: 74V to 264V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh surge capacity: 16A for 100 ms, repeatable every 10 s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReinforced insulation rated for 240V continuous, tested at 3250V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact DIN-rail mountable design compatible with multiple POINT I\/O bases (1734-TB, TBS, TOP, TOPS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePOINTBus current: up to 175 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum power dissipation: 3.5 W @ 264V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OA4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O AC Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs per Module:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 non-isolated, sourcing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120\/220V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e74–264V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Voltage Drop:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 1.0 V @ 0.75 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 A for 100 ms, repeatable every 10 s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e240 V AC continuous, Reinforced Insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTested Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3250 V DC for 60 s (field-side to system)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Screw Torque:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.8 Nm (7 lb-in.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Location:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 1734-TB, TBS, TOP, TOPS wiring base assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 3.5 W @ 264V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 11.9 BTU\/hr\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMax 75 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (L×W×H):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7.55 × 1.2 × 5.6 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OA4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eControlling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotors, solenoids, and relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein distributed I\/O systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular integration in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor manufacturing automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAC output applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh surge tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand reinforced insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many AC outputs does the 1734-OA4 provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour non-isolated sourcing outputs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What voltage range does it support?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt operates across\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e74V to 264V AC\u003c\/strong\u003e, compatible with 120\/220V AC systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which POINT I\/O wiring bases are compatible?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS wiring base assemblies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the module surge-protected?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it tolerates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16A surge for 100 ms\u003c\/strong\u003e, repeatable every 10 seconds.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52154602586421,"sku":"1734-OA4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OA4.jpg?v=1767926414"},{"product_id":"1734-aent-ethernet-ip-communication-module-allen-bradley-point-i-o","title":"1734-AENT EtherNet\/IP Communication Module | Allen-Bradley Point I\/O","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-AENT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Point I\/O EtherNet\/IP adapter module that enables distributed I\/O systems to seamlessly integrate into Ethernet networks.\u003cbr\u003eIt provides high-speed data exchange and flexible I\/O expansion, making it suitable for industrial applications requiring modular control and efficient communication between controllers and field devices.\u003cbr\u003eThis adapter allows multiple I\/O modules to connect through a single Ethernet node, reducing wiring complexity and installation time.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENT\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePoint I\/O EtherNet\/IP Communication Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBulletin 1734 Point I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range: 10…28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal Input Voltage: 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: 4.5 W max @ 28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Dissipation: 15.5 W max @ 28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePointBus Output Current: 1 A max @ 5V DC (±5%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Protection: Reverse polarity protected\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Dissipation: 9.5 BTU\/hr max @ 28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication \u0026amp; Network\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCommunication Protocol: EtherNet\/IP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Speed: 10\/100 Mbps, half\/full duplex auto-negotiation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Topologies: Star, linear, and device-level ring (DLR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIP Addressing: DHCP, BOOTP, or static configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Number of I\/O Modules: 63 per adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED Indicators: Network status, module status, and PointBus status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (H × W × D): 133.5 × 54.9 × 76.2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.3 kg (0.66 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Type: DIN rail (IEC\/EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Type: Open-style (IP20)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation Voltage: 1800V DC for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to +55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −40°C to +85°C (−40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: 5 g @ 10–500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: 30 g operating, 50 g non-operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Notes\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is used in distributed I\/O systems for process control, packaging machinery, and automotive manufacturing.\u003cbr\u003eIt supports real-time communication with Logix controllers over EtherNet\/IP networks, ensuring deterministic performance and reliable operation.\u003cbr\u003eIts modular design allows engineers to add or remove I\/O points without disrupting network communication.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the maximum number of Point I\/O modules supported by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-AENT\u003c\/strong\u003e?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 63 Point I\/O modules can be connected per adapter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDoes the adapter support redundant Ethernet connections?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it supports Device-Level Ring (DLR) topology for network redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow is the module powered?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe adapter operates on a 24V DC supply, with reverse polarity protection included.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs configuration possible via USB?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, configuration is handled over Ethernet using Studio 5000 or BOOTP\/DHCP tools.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52157748642101,"sku":"1734-AENT","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-AENT.jpg?v=1767943473"},{"product_id":"1734-aent-ethernet-ip-communication-module-allen-bradley-point-i-o-副本","title":"1734-IE2I | Allen-Bradley | POINT I\/O Isolated Analog Input Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE2I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a two-channel isolated analog input module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily, designed for applications requiring accurate and noise-resistant analog signal measurement.\u003cbr\u003eIts isolated design prevents signal interference and ensures high reliability in distributed control architectures.\u003cbr\u003eThis module is ideal for capturing analog data such as current or voltage signals in compact automation systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2I\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolated Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInput Type: Isolated analog inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Inputs: 2 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Types Supported: Voltage or current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Input Range: ±10 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Input Range: 0–20 mA or 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 16 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.1% of full scale typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConversion Method: Delta-Sigma\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Impedance: 250 Ω (current), 1 MΩ (voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePOINTBus Current: 75 mA @ 5 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Dissipation: 1.5 W max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Dissipation: 5.1 BTU\/hr\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (H × W × D): 75.5 × 12 × 56 mm (2.97 × 0.47 × 2.2 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: Approx. 30 g (0.07 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN Rail (EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Type: Removable Terminal Block (1734-TOP or 1734-TOP3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED Indicators: Module status and channel diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to +55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −40°C to +85°C (−40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: 5 g @ 10–500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation Voltage: Channel-to-channel and channel-to-system isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution 16-bit conversion for accurate analog signal acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChannel-to-channel isolation prevents cross-talk and ground loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design ideal for distributed I\/O applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimple wiring with removable terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED status indicators for quick diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull compatibility with POINT I\/O system architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is used in process automation, factory control, and machine monitoring systems where precise analog measurement is essential.\u003cbr\u003eTypical applications include temperature monitoring, pressure and flow sensing, or current-loop feedback control in compact distributed systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat input types does the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports both voltage (±10V DC) and current (0–20 mA or 4–20 mA) signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAre the channels on this module isolated?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, each channel is individually isolated for superior noise immunity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat terminal blocks are compatible with this module?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt works with 1734-TOP and 1734-TOP3 terminal blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it be used with standard POINT I\/O adapters?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it is fully compatible with 1734-AENT and 1734-AENTR Ethernet adapters.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52157840916789,"sku":"1734-IE2I","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IE2I.jpg?v=1767943930"},{"product_id":"allen-bradley-1734-ie2v-point-i-o-2-channel-voltage-analog-module","title":"Allen-Bradley 1734-IE2V POINT I\/O 2-Channel Voltage Analog Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel, non-isolated voltage input module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eline, engineered for compact analog signal acquisition.\u003cbr\u003eDesigned for high-resolution monitoring, this module accurately captures voltage signals in both unipolar and bipolar modes.\u003cbr\u003eIts compact footprint allows seamless integration into distributed control systems where precise voltage measurement is required.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2V\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVoltage Input Analog Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Inputs: 2 single-ended voltage channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Isolation: Non-isolated between channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Voltage Range: ±10 V DC typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 15-bit plus sign, 320 µV\/count\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConversion Method: Delta-Sigma\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital Filter Time Constant: 0–10,000 ms (default = 0 ms)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePOINTBus Current: 75 mA @ 5 V DC maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Dissipation: 0.75 W @ 28.8 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Dissipation: 2.5 BTU\/hr @ 28.8 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Overvoltage Protection: ±50 V DC continuous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation Test Voltage: Withstands 2200 V DC for 60 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (L × W × H): 75.5 × 12 × 56 mm (2.97 × 0.47 × 1.2 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.03 kg (0.066 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Base Compatibility: 1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN Rail (EN 60715)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndicators: LED for module status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: 0°C to +55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: −40°C to +85°C (−40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration: Industrial rating for control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Type: Open-style (IP20)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTwo high-resolution voltage input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both unipolar and bipolar voltage measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDelta-Sigma conversion for precise signal acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact POINT I\/O design for tight panel spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with multiple removable terminal blocks for easy wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED status indicators for simplified diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for distributed I\/O systems in factory automation, machine monitoring, and process control where high-accuracy voltage measurement is critical.\u003cbr\u003eCommon applications include sensor voltage feedback, process control signals, and analog data acquisition in tight panel layouts.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHow many voltage inputs does the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo single-ended voltage inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAre the inputs isolated?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe channels are non-isolated.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhich terminal bases are compatible?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-TB, 1734-TBS, 1734-TOP, and 1734-TOPS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it measure both positive and negative voltages?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, supports unipolar and bipolar modes.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52157846946101,"sku":"1734-IE2V","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IE2V.jpg?v=1767944200"},{"product_id":"allen-bradley-point-i-o-1734-ob8e-digital-output-module","title":"Allen-Bradley POINT I\/O 1734-OB8E Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 8-point digital output module from Allen-Bradley’s POINT I\/O series. It provides precise DC sourcing outputs and is optimized for compact and distributed control systems. The module is designed for durability, reliable operation, and seamless integration with other POINT I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8E\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O 1734\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDC Sourcing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–28.8 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current per Point:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Module Output Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 A for 10 ms, repeatable every 3 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA at 5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6.8 BTU\/hour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (L×W×H):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e56 × 12 × 75.5 mm (2.2 × 0.47 × 2.97 in)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN Rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKey Switch Position:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSlim form factor allows installation in limited spaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemovable Terminal Blocks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSimplifies wiring, maintenance, and module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides real-time feedback on output status and system operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in safeguards against short circuits and overloads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to withstand industrial operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with other POINT I\/O modules for scalable systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial automation requiring reliable DC outputs for actuators, relays, and small devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control systems in manufacturing, processing, or material handling lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironments demanding compact, modular, and easily maintainable output modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIs the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompatible with all POINT I\/O terminal bases?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt works specifically with POINT I\/O bases such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it handle high inrush current?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module supports 2 A surge for 10 ms, repeatable every 3 seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52180074955061,"sku":"1734-OB8E","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB8E1.jpg?v=1768206641"},{"product_id":"allen-bradley-point-i-o-1734-1734-ib8-8-channel-dc-sinking-input-module","title":"Allen Bradley POINT I\/O 1734 | 1734-IB8 | 8-Channel DC Sinking Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-IB8\u003c\/strong\u003e is a POINT I\/O digital input module designed for distributed control systems requiring compact, modular input solutions. It provides eight sinking DC input channels with user-selectable filtering, making it suitable for high-speed and noise-sensitive applications. The module integrates seamlessly into POINT I\/O systems, offering efficient power usage and clear diagnostic indicators.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e POINT I\/O 1734\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLC Input Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003e1734-IB8\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e Digital DC sinking input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 8 channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 10–28.8 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Current Range:\u003c\/strong\u003e 2–5 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Current:\u003c\/strong\u003e 4 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Input Current:\u003c\/strong\u003e 5 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Filter Time:\u003c\/strong\u003e 0.5 ms hardware + 0–63 ms user-configurable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 1.6 W \/ 5.5 BTU per hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current Draw:\u003c\/strong\u003e 75 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open-style (no protective housing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeyswitch Position:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Location:\u003c\/strong\u003e Compatible with 1734-TB or 1734-TBS wiring base assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 green\/red LED (logic side, module status)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8 yellow LEDs (logic side, input status)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e1734-IB8\u003c\/strong\u003e is widely used in distributed I\/O systems for monitoring sensors, switches, and other DC input devices. Its compact design and modular wiring base compatibility make it ideal for applications requiring scalable input expansion.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many inputs does this module provide?\u003c\/strong\u003e  A: It supports eight sinking DC input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the nominal input voltage?\u003c\/strong\u003e  A: The module is designed for 24 VDC nominal input, with a range of 10–28.8 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the input filter time be adjusted?\u003c\/strong\u003e  A: Yes, it includes a hardware filter of 0.5 ms plus a user-selectable range of 0–63 ms.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What wiring bases are compatible?\u003c\/strong\u003e  A: It can be installed on 1734-TB or 1734-TBS base assemblies.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52301146259765,"sku":"1734-IB8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IB8.jpg?v=1770279924"},{"product_id":"allen-bradley-point-i-o-1734-1734-ob8-8-channel-dc-sourcing-output-module","title":"Allen Bradley POINT I\/O 1734 | 1734-OB8 | 8-Channel DC Sourcing Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-OB8\u003c\/strong\u003e is a POINT I\/O digital output module designed for distributed control systems requiring compact and modular output functionality. It provides eight sourcing DC output channels with fast response times and electronic protection, making it suitable for high-performance industrial automation tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e POINT I\/O 1734\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLC Output Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003e1734-OB8\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e Digital DC sourcing output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e 8 channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 10–28.8 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNominal Output Voltage:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current per Channel:\u003c\/strong\u003e 1 A (nominal)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Output Current per Module:\u003c\/strong\u003e 3 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Signal Delay:\u003c\/strong\u003e 0.1 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 2.0 W \/ 6.8 BTU per hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current Draw:\u003c\/strong\u003e 75 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open-style (no protective housing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeyswitch Position:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Location:\u003c\/strong\u003e Compatible with 1734-TB or 1734-TBS wiring base assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e2 green\/red LEDs (module and network status)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e8 yellow LEDs (output status, logic side)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e Electronically protected against overloads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e 6.8 BTU\/hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e1734-OB8\u003c\/strong\u003e is ideal for controlling actuators, solenoids, pilot lights, and other DC-powered devices in distributed I\/O systems. Its fast switching capability and electronic protection make it well-suited for environments requiring reliable and safe output control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many outputs does this module provide?\u003c\/strong\u003e  A: It supports eight sourcing DC output channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the nominal output voltage?\u003c\/strong\u003e  A: The module operates at 24 VDC nominal, with a range of 10–28.8 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the module protected against overloads?\u003c\/strong\u003e  A: Yes, it includes electronic protection for safe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which wiring bases are compatible?\u003c\/strong\u003e  A: It can be installed on 1734-TB or 1734-TBS base assemblies.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52301162676533,"sku":"1734-OB8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB8.jpg?v=1770280226"},{"product_id":"allen-bradley-point-i-o-series-1734-ep24dc-expansion-power-supply","title":"Allen Bradley | Point I\/O Series | 1734-EP24DC | Expansion Power Supply","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-EP24DC\u003c\/strong\u003e Expansion Power Supply is a compact and efficient module designed for the Point I\/O 1734 system. It provides stable 24 V DC field power distribution and supports both horizontal and vertical mounting orientations, making it suitable for flexible installation in industrial control environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e Point I\/O 1734\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e Expansion Power Supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1734-EP24DC\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.38 lbs (0.17 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e 10 BTU\/hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e 50 V continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e 6 A for 10 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e Reverse polarity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Current\u003c\/strong\u003e 10 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e 9.8 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField Power\u003c\/strong\u003e 24 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e Horizontal \/ Vertical\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Output Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHorizontal: 1 A @ 10–19.2 V input; 1.3 A @ 19.2–28.8 V input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVertical: 1 A @ 10–28.8 V input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e 3 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular distributed I\/O systems requiring additional power capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact control panels with limited space\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation setups needing reliable 24 V DC expansion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the 1734-EP24DC compatible with all Point I\/O modules?\u003c\/strong\u003e  A: Yes, it is designed specifically to expand power within the Point I\/O 1734 platform.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What protection features are included?\u003c\/strong\u003e  A: The unit provides reverse polarity protection to safeguard connected devices.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does orientation affect output performance?\u003c\/strong\u003e  A: Yes, output current differs slightly depending on horizontal or vertical mounting.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-EPAC\u003c\/strong\u003e: AC-powered expansion supply for Point I\/O systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-EP24DC\u003c\/strong\u003e: DC-powered expansion supply (this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-EP24DCX\u003c\/strong\u003e: Extended current version for higher load requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52311484006709,"sku":"1734-EP24DC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-EP24DC.jpg?v=1770604081"},{"product_id":"1734-top-allen-bradley-point-i-oterminal-base-screw-clamp-8-position","title":"1734-TOP | Allen Bradley Point I\/OTerminal Base | Screw Clamp | 8 Position","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-TOP\u003c\/strong\u003e Terminal Base is a single-piece screw-clamp module designed for the Point I\/O 1734 system. It provides secure wiring connections and reliable mechanical support for I\/O modules, ensuring stable performance in industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e Point I\/O 1734\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e Terminal Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1734-TOP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.25 lbs (0.11 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e POINT I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePositions\u003c\/strong\u003e 8\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eClamp Type\u003c\/strong\u003e Screw-clamp\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for distributed I\/O systems requiring robust wiring connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for compact control panels with limited space\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for environments where screw-clamp terminals are preferred for secure fastening\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many wiring positions does the 1734-TOP provide?\u003c\/strong\u003e  A: It offers 8 screw-clamp positions for secure connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can this terminal base be used with other Point I\/O modules?\u003c\/strong\u003e  A: Yes, it is fully compatible with the Point I\/O 1734 series modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the advantage of screw-clamp terminals?\u003c\/strong\u003e  A: Screw-clamp terminals provide strong mechanical retention and reliable electrical contact, especially in vibration-prone environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-TOP\u003c\/strong\u003e: Screw-clamp terminal base (this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-TB3\u003c\/strong\u003e: Spring-clamp terminal base for faster wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-TOPX\u003c\/strong\u003e: Extended screw-clamp version for higher-density applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52311496196405,"sku":"1734-TOP","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-TOP.jpg?v=1770604424"},{"product_id":"allen-bradley-1734-ow4-point-i-o-4-point-relay-output-module","title":"Allen Bradley 1734-OW4 | POINT I\/O 4-Point Relay Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-OW4\u003c\/strong\u003e POINT I\/O module provides four isolated electromechanical relay outputs, designed for flexible digital output control in distributed automation systems. Each channel uses Form A (normally open) contacts, offering reliable switching for both AC and DC loads. With robust isolation, compact design, and long contact life, this module is well-suited for industrial applications requiring dependable relay-based output control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e POINT I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e Digital Output Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1734-OW4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs per Module\u003c\/strong\u003e 4 Form A isolated (NO) relay contacts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOff-State Leakage Current\u003c\/strong\u003e Max 1.2 mA @ 240 V AC (with bleed resistor through snubber circuit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e 5 V DC, 90 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e 0.8 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e Max 0.5 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eContact Ratings\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e120\/240 V AC, 2.0 A @ 50\/60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1800 VA make, 180 VA break\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e5–30 V DC, 2.0 A, R150\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e 250 V, tested at 2550 V DC for 60 s (field-to-system and between contact sets)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e Max 1 operation per 3 s (0.3 Hz @ rated load)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Contact Life\u003c\/strong\u003e Minimum 100,000 operations @ rated load\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring Category\u003c\/strong\u003e Category 1 (signal ports)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e 0.25–2.5 mm² (22–14 AWG), solid or stranded copper, rated 85 °C or higher, insulation max 1.2 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Base Screw Torque\u003c\/strong\u003e Determined by installed terminal block\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.06 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelay-based digital output control in distributed POINT I\/O systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSwitching AC or DC loads in industrial automation panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplications requiring isolated relay contacts for safety and reliability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many relay outputs does the 1734-OW4 provide?\u003c\/strong\u003e  A: It includes four Form A (normally open) isolated relay outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the expected contact life?\u003c\/strong\u003e  A: At least 100,000 operations under rated load conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What isolation voltage is supported?\u003c\/strong\u003e  A: 250 V, tested at 2550 V DC for 60 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-OW4\u003c\/strong\u003e: 4-point relay output module (this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-OB8\u003c\/strong\u003e: 8-point DC transistor output module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-OV4\u003c\/strong\u003e: 4-point DC sinking output module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52311786029365,"sku":"1734-OW4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OW4.jpg?v=1770615975"},{"product_id":"allen-bradley-1734-tb-point-i-o-terminal-base-screw-clamp","title":"Allen Bradley 1734-TB | POINT I\/O Terminal Base | Screw Clamp","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-TB\u003c\/strong\u003e is a POINT I\/O terminal base designed for use with POINT I\/O modules. It provides secure electrical connections through eight screw-clamp terminals and supports assembly styles including 1734-MB and 1734-RTB. With DIN rail mounting and an open-style body, this terminal base ensures reliable integration into distributed control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e POINT I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e Terminal Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e PLCs \/ Machine Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSubcategory\u003c\/strong\u003e PLC Programming Terminal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.22 lbs (0.10 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAssembly Style\u003c\/strong\u003e Compatible with 1734-MB and 1734-RTB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Style\u003c\/strong\u003e 8 screw-clamp terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e DIN rail mounted\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBody Style\u003c\/strong\u003e Open-style design\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring Category\u003c\/strong\u003e Category 1 (signal ports)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWire Size Compatibility\u003c\/strong\u003e 22–14 AWG solid or stranded copper conductors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides the physical connection interface for POINT I\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for distributed automation systems requiring modular expansion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUsed in control panels where secure screw-clamp wiring is preferred\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many terminals does the 1734-TB provide?\u003c\/strong\u003e  A: It includes eight screw-clamp terminals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What mounting style is supported?\u003c\/strong\u003e  A: DIN rail mounting for quick installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this terminal base compatible with other POINT I\/O bases?\u003c\/strong\u003e  A: Yes, it supports assembly styles 1734-MB and 1734-RTB.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e: Screw-clamp terminal base (this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e: Spring-clamp terminal base variant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-TB3\u003c\/strong\u003e: Three-row terminal base for higher density wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52311834722613,"sku":"1734-TB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-TB.jpg?v=1770616255"},{"product_id":"allen-bradley-1734-oe2v-point-i-o-2-channel-analog-voltage-output-module","title":"Allen Bradley 1734-OE2V | POINT I\/O 2-Channel Analog Voltage Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-OE2V\u003c\/strong\u003e is a POINT I\/O analog output module designed to provide two single-ended, non-isolated voltage outputs. Compact and lightweight, it integrates seamlessly into POINT I\/O systems, offering fast conversion rates and high-resolution signal processing. With a signed integer data format and 14-bit resolution, the module ensures precise voltage control for industrial automation applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e POINT I\/O 1734 Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e Analog Output Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e 2 single-ended, non-isolated analog voltage outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e 0–10 V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Load\u003c\/strong\u003e 3 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e Digital-to-Analog\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConversion Rate\u003c\/strong\u003e 20 µs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e Signed integer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e 14-bit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e –20 to 55 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMachine-level automation requiring precise voltage signal control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDistributed POINT I\/O systems with compact analog output needs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial environments needing fast conversion and high-resolution outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many outputs does the 1734-OE2V provide?\u003c\/strong\u003e  A: It supports two single-ended, non-isolated voltage outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the resolution of the module?\u003c\/strong\u003e  A: The module offers 14-bit resolution for accurate signal processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the conversion rate?\u003c\/strong\u003e  A: 20 microseconds per conversion.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e: 2-channel voltage output module (this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IE2V\u003c\/strong\u003e: 2-channel voltage input module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-OE4V\u003c\/strong\u003e: 4-channel voltage output module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52312292622645,"sku":"1734-0E2V","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-0E2V.jpg?v=1770625486"},{"product_id":"allen-bradley-1734-ie4s-point-i-o-safety-analog-input-module","title":"Allen Bradley 1734-IE4S Point I\/O Safety Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-IE4S\u003c\/strong\u003e is a Point I\/O safety-rated analog input module designed for precise monitoring of analog signals in safety-critical applications. With four single-ended input channels, per-channel isolation, and compatibility with both thermocouples and RTDs, this module provides reliable integration into POINTBus systems. Its SIL\/PL capability ensures compliance with safety standards, making it suitable for demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Point I\/O 1734\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong\u003e1734-IE4S\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.19 lbs (0.09 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Safety Analog Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Configuration:\u003c\/strong\u003e Single-ended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 4 channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Platform:\u003c\/strong\u003e POINTBus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Rating:\u003c\/strong\u003e SIL\/PL capable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Input Range:\u003c\/strong\u003e ±10 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Input Range:\u003c\/strong\u003e 0–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Range (DC):\u003c\/strong\u003e 0–24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Sensors:\u003c\/strong\u003e Thermocouples (TC) and RTDs (Pt, Nickel, Copper)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e Per-channel isolation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Communication:\u003c\/strong\u003e POINTBus backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTypical Application:\u003c\/strong\u003e Safety analog sensing and monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety-critical monitoring of analog signals in industrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration with POINT I\/O systems for distributed control architectures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for temperature sensing with RTDs and thermocouples\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for current and voltage input monitoring in safety-rated systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many input channels does the 1734-IE4S provide?\u003c\/strong\u003e  A: It supports 4 single-ended input channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What types of sensors are supported?\u003c\/strong\u003e  A: The module supports thermocouples and RTDs, including platinum, nickel, and copper types.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the module SIL\/PL rated?\u003c\/strong\u003e  A: Yes, it is SIL\/PL capable, making it suitable for safety applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparison with Similar Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IE4S:\u003c\/strong\u003e Safety-rated analog input, 4 channels, SIL\/PL capable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IE2C:\u003c\/strong\u003e Standard analog input, 2 channels, non-safety rated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IR2:\u003c\/strong\u003e RTD input module, 2 channels, optimized for temperature sensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52366002258229,"sku":"1734-IE4S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IE4S.jpg?v=1771919138"},{"product_id":"allen-bradley-point-i-o-1734-ir2-rtd-input-module","title":"Allen Bradley Point I\/O 1734-IR2 | RTD Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Allen Bradley Point I\/O \u003cstrong\u003e1734-IR2\u003c\/strong\u003e is a compact RTD and resistance input module engineered for precise temperature measurement and resistance monitoring. With two single-ended, non-isolated channels, it supports a wide range of RTD sensor types and resistance inputs, making it suitable for diverse industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e PLCs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e Point I\/O 1734\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1734-IR2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.06 lbs (0.03 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e 6\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e 1.0 W @ 28.8 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e RTD \/ Resistance Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e POINT I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e 2 single-ended, non-isolated channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible RTD Sensors\u003c\/strong\u003e 100 Pt α = 0.00385; 200 Pt α = 0.00385; 100 Pt α = 0.003916; 200 Pt α = 0.003916; 10 Cu α = 0.00427; 100 Ni α = 0.00618; 120 Ni α = 0.00618; 120 Ni α = 0.00672\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResistance Input Range\u003c\/strong\u003e 0–600 Ω\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e 16-bit, 9.5 mΩ\/count; 0.03 °C\/count (Pt385 @ 25 °C) or 0.05 °F\/count (Pt385 @ 77 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAbsolute Accuracy\u003c\/strong\u003e ±0.1% full scale @ 25 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Step Response (per channel)\u003c\/strong\u003e 60 ms @ 50 Hz notch; 33 ms @ 60 Hz notch (default); faster response at higher notch frequencies down to 4 ms @ 480 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Update Rate (per module)\u003c\/strong\u003e 40 ms @ 50 Hz notch; 33 ms @ 60 Hz notch (default); 20 ms @ 100 Hz notch; 4 ms @ 480 Hz notch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e 220 mA @ 5 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e Delta-Sigma\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e Signed integer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e 50 V continuous\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e 3.3 BTU\/hour\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e Open-style (no rating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Location\u003c\/strong\u003e Compatible with 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS wiring base assemblies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e -20 to 55 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemperature monitoring in process control systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eResistance measurement for specialized industrial sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegration into distributed Point I\/O systems for scalable automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What types of RTD sensors are supported?\u003c\/strong\u003e  A: The module supports platinum, copper, and nickel RTDs with multiple alpha coefficients, including Pt385, Pt3916, Cu427, Ni618, and Ni672.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How accurate is the measurement?\u003c\/strong\u003e  A: It provides ±0.1% full-scale accuracy at 25 °C, ensuring reliable readings in critical applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the typical update rate?\u003c\/strong\u003e  A: Default update rate is 33 ms at 60 Hz notch, with faster rates available depending on notch frequency settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparable Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IT2I\u003c\/strong\u003e: Thermocouple input module for temperature measurement using thermocouples.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IR2E\u003c\/strong\u003e: Enhanced RTD input module with extended features and improved performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52380061204789,"sku":"1734-IR2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IR2.jpg?v=1772157431"},{"product_id":"1734-oe4c-allen-bradley-4-channel-analog-current-output-module","title":"1734-OE4C | Allen-Bradley 4-Channel Analog Current Output Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE4C (1734-OE4C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog output expansion module designed for the Rockwell Automation POINT I\/O platform. This module provides four single-ended, high-precision current outputs, allowing for granular control of field devices such as actuators, variable frequency drive speed references, and control valves. Its compact, modular design permits vertical or horizontal mounting, significantly reducing cabinet space requirements while maintaining robust signal integrity.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications and Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE4C (1734-OE4C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverts digital values into analog signals with high resolution and rapid conversion rates, ensuring responsive control loops in demanding industrial environments.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e: 4 Single-ended\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e: 0 to 20 mA or 4 to 20 mA (Configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 13 bits plus sign (approximately 16 bits across the 0–21 mA range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e: Signed Integer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e: Digital-to-Analog (DAC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStep Response Rate\u003c\/strong\u003e: 20 microseconds (Conversion speed to 99% of full scale)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal DC Supply\u003c\/strong\u003e: 24V DC nominal (Range: 10–28.8V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Current\u003c\/strong\u003e: 75 mA at 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBUS Current\u003c\/strong\u003e: 75 mA maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Impedance\u003c\/strong\u003e: 0 to 750 Ohms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e: 1.2 Watts maximum (Internal module heat loss)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e: 4.1 BTU\/hr\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE4C (1734-OE4C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esnaps easily onto a 1734-TB or 1734-TBS terminal base. It features an integrated keyswitch that prevents the accidental insertion of a module into an incorrect base, protecting the system from electrical mismatches.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle a loss of network communication?\u003c\/strong\u003eThe module can be configured via Studio 5000 to hold its last state or transition to a specific \"safe\" value (e.g., 4 mA) if communication with the controller is interrupted.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs calibration required for this module?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE4C (1734-OE4C)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis factory calibrated. However, users can perform scaling within the controller software to match specific engineering units or compensate for field device variations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the status indicators on the front panel?\u003c\/strong\u003eThere are four individual status indicators (one per channel) and one module status indicator. These provide real-time diagnostics for power status, communication health, and field-side faults.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52380659286325,"sku":"1734-OE4C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OE4C.jpg?v=1772164922"},{"product_id":"1734-tops-allen-bradley-point-i-o-terminal-base-spring-clamp","title":"1734-TOPS | Allen-Bradley POINT I\/O Terminal Base | Spring Clamp","description":"\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen-Bradley 1734-TOPS POINT I\/O Terminal Base\u003c\/strong\u003e is designed to provide a secure and reliable connection for POINT I\/O modules. Featuring a spring clamp design, it ensures consistent wiring performance and supports a wide range of industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen-Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e \u003cstrong\u003e1734-TOPS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e POINT I\/O Terminal Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eField Power Bus Supply Voltage\u003c\/strong\u003e 28.8 VDC, 120\/240 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eATEX Temperature Code\u003c\/strong\u003e T4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e 0.25–2.5 mm² (22–14 AWG) solid or stranded copper wire, rated at 75 °C (167 °F) or higher, with maximum insulation of 1.2 mm (3\/64 in.)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWire Category\u003c\/strong\u003e Dependent on I\/O module installed in terminal base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Terminal Voltage\u003c\/strong\u003e 300 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Terminal Current\u003c\/strong\u003e 8 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e 14.4 cm x 1.2 cm x 4.9 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.06 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for distributed I\/O systems in industrial automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for machine control, process control, and monitoring applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides modular flexibility for POINT I\/O installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of wiring is supported?\u003c\/strong\u003e  A: Solid or stranded copper wire between 22–14 AWG, rated at 75 °C or higher.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the maximum current capacity?\u003c\/strong\u003e  A: The terminal base supports up to 8 A.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this terminal base compatible with all POINT I\/O modules?\u003c\/strong\u003e  A: Compatibility depends on the specific I\/O module installed.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52381025075509,"sku":"1734-TOPS","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-TOPS.jpg?v=1772175900"},{"product_id":"1734-ie8c-allen-bradley-point-i-o-8-channel-high-density-analog-current-input-module","title":"1734-IE8C | Allen-Bradley POINT I\/O 8-Channel High-Density Analog Current Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE8C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog input module designed for the Allen-Bradley POINT I\/O system, providing eight single-ended channels for precise current sensing. This module is an ideal solution for industrial applications requiring a compact footprint without sacrificing channel density. It efficiently converts analog signals from field devices—such as pressure transmitters, flow meters, and temperature sensors—into digital data for processing by Logix-based controllers. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE8C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both 0–20 mA and 4–20 mA input ranges, allowing for versatile integration across various process control environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Allen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e: POINT I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE8C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Quantity\u003c\/strong\u003e: 8 Channels (Single-ended, Non-isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e: 0 to 20 mA or 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e: 16-bit (0 to 21 mA corresponds to 0–32767 counts)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e: 75 mA maximum @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e: 0.6 Watts @ 28.8V DC maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e: 2.0 BTU\/hr @ 28.8V DC maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e: 50V (Continuous), tested at 1500V AC for 60 seconds (Field-to-System)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e: 50 Ohms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e: 3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Base Requirement\u003c\/strong\u003e: Compatible with 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e: Open-style enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e: 75.5mm x 12mm x 56mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e: 0.04 kg (0.088 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE8C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule snaps easily into the POINT I\/O terminal base, utilizing a sliding mechanism for secure attachment to adjacent modules. The high-density 8-channel design significantly reduces the required DIN rail space compared to standard 2 or 4-channel modules. It is essential to ensure that the terminal base is correctly wired, as there is no isolation between individual input channels. For applications in high-vibration environments, the 1734-TBS (spring clamp) base is recommended to maintain electrical contact integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-IE8C support HART protocol pass-through?\u003c\/strong\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE8C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a standard analog current input module. If HART communication is required for instrument diagnostics, the 1734-IE8CH (HART-enabled version) should be used instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix 0–20mA and 4–20mA sensors on the same module?\u003c\/strong\u003eYes, the input range is software-configurable via Studio 5000 or RSLogix 5000. You can define the specific current range for each channel according to the connected field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the Keyswitch Position 3?\u003c\/strong\u003eThe keyswitch on the terminal base must be set to position 3 before inserting the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IE8C\u003c\/strong\u003e. This mechanical interlock prevents the accidental insertion of a different module type into a base wired for high-density current inputs, protecting the hardware from electrical damage.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52381180985653,"sku":"1734-IE8C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IE8C.jpg?v=1772181027"},{"product_id":"allen-bradley-1734-ik-point-i-o-incremental-encoder-interface-module","title":"Allen Bradley | 1734-IK | POINT I\/O Incremental Encoder Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1734-IK\u003c\/strong\u003e POINT I\/O Incremental Encoder Interface Module is designed to integrate incremental encoder signals into PLC systems. Compact and lightweight, this open-style module provides precise counting and position feedback for automation applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1734-IK\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e POINT I\/O 1734 Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.13 lbs (≈ 0.06 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e Incremental Encoder Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCounter Channels:\u003c\/strong\u003e 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 15–24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e 10.2 mA @ 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Switch Position:\u003c\/strong\u003e 2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e Open-style (no protective enclosure)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWiring Category:\u003c\/strong\u003e Category 1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThis module is suitable for applications requiring encoder feedback such as motion control, conveyor systems, and machine positioning. It provides reliable integration of incremental encoder signals into POINT I\/O networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eComparison with Similar Modules\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1734-IK:\u003c\/strong\u003e Single counter channel, incremental encoder input, compact design.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOther POINT I\/O encoder modules: May support absolute encoders or multiple counters, offering broader functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the 1734-IK be used with absolute encoders?\u003c\/strong\u003e  A: No, it is specifically designed for incremental encoders.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the wiring category for installation?\u003c\/strong\u003e  A: Category 1 wiring is required for proper operation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52390779289909,"sku":"1734-IK","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IK.jpg?v=1772433685"},{"product_id":"allen-bradley-1734-ib8s-point-i-o-guard-i-o-safety-input-module","title":"Allen-Bradley 1734-IB8S | POINT I\/O Guard I\/O Safety Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-IB8S\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-IB8S\u003c\/strong\u003e\u003cspan class=\"\"\u003e) is a high-density safety input solution designed for the Allen-Bradley POINT I\/O platform.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is engineered to integrate seamlessly into SIL 3 and PLe safety applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering eight sinking input channels and four dedicated pulse test outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing CIP Safety protocol over EtherNet\/IP or DeviceNet,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit provides distributed safety control with advanced diagnostics for detecting short circuits and cross-channel faults in field wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eTechnical Specifications and Hardware Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Brand\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Identifier\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-IB8S\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Series\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O Guard I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Quantity\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8 Safety Inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Configuration\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCurrent Sinking (Dry Contact or Solid State)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTest Pulse Outputs\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 Pulse Test Sources\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNominal Operating Voltage\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Voltage Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e19.\u003c\/span\u003e\u003cspan class=\"\"\u003e2V DC to 28.\u003c\/span\u003e\u003cspan class=\"\"\u003e8V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePOINTBus Current Draw\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e175 mA at 5V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 Watts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Certification\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSIL 3 (IEC 61508) and PLe\/Category 4 (ISO 13849-1)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Performance\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e8A total current capacity at 20°C ambient\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCompatible Terminal Bases\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-TB\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-TBS\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-TOP\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-TOPS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMechanical Keying\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePosition 8 (Key 1) and Position 1 (Key 2)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnclosure Rating\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIP20 Open-style for cabinet mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHardware Revision Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSeries A and Series B\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eModule Functional Features and Safety FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHow do the pulse test outputs improve circuit safety?\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-IB8S\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003egenerates specific pulse patterns on its four test outputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eWhen these are wired through safety devices back to the inputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module can detect if a wire has been crushed,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eshorted to a 24V power source,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor shorted to another input signal.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis prevents a \"stuck-on\" failure which could bypass a safety function.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCan this module be used with standard 1734 adapters?\u003c\/strong\u003e\u003cspan class=\"\"\u003eNo,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eto utilize the safety functions of the\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e1734-IB8S\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eyou must use a safety-rated network adapter such as the 1734-AENTR (for EtherNet\/IP) and a GuardLogix or SmartGuard controller that supports CIP Safety communications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eWhat is the significance of the thermal derating value?\u003c\/strong\u003e\u003cspan class=\"\"\u003eAt an ambient temperature of 20°C,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module can handle a cumulative field power current of 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e8A across all channels.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs the temperature inside the electrical cabinet increases toward the maximum operating limit of 55°C,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe allowable current decreases.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineers must calculate the total load of connected sensors to ensure the module remains within its safe thermal operating envelope.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52407906337077,"sku":"1734-IB8S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IB8S.jpg?v=1772785267"},{"product_id":"1734-ob8s-allen-bradley-point-guard-i-o-8-point-24vdc-digital-safety-output-module","title":"1734-OB8S | Allen-Bradley POINT Guard I\/O | 8-Point 24VDC Digital Safety Output Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability POINT Guard I\/O module designed for safety-critical applications within the Allen-Bradley (Rockwell Automation) ecosystem. Functioning as a specialized 8-point digital safety output module, it provides the deterministic control required for emergency stops, light curtains, and safety gate interlocks. When integrated into a GuardLogix or SmartGuard controller system via EtherNet\/IP or DeviceNet, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that safety functions are executed with SIL 3, PLe, and Cat. 4 compliance. Its compact POINT I\/O form factor allows for localized safety control, reducing complex wiring runs to the main control cabinet.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to provide fail-safe switching of 24V DC field loads while continuously performing internal diagnostics to detect short circuits or ground faults.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT Guard I\/O Safety Output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Output Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Points (Sourcing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Supply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19.2 to 28.8V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.0A total per module (1.0A per point @ 40°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.5 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15.38 BTU\/hour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSIL 3 (IEC 61508), PLe (ISO 13849-1), Category 4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e175 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePoint-Level Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShort-circuit detection, overload protection, and pulse testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHorizontal or Vertical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.25 lbs (0.11 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen-style (IP20)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAdvanced Safety and Diagnostic Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels in identifying potential hardware failures before they lead to a dangerous state. Each output is capable of performing \"Pulse Testing,\" which momentarily switches the output off and back on (too fast to affect the load) to verify that the switching circuitry is functional and that no external cross-circuit exists. In the event of a detected fault, the module transitions to a safe \"Off\" state and reports the specific error code back to the safety controller for rapid troubleshooting.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eSystem Requirements and Installation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTo utilize the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e, the module must be seated in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eremovable terminal base. It requires a 1734-AENTR (Ethernet) or 1734-PDN (DeviceNet) adapter that supports CIP Safety protocol. During configuration in Studio 5000 Logix Designer, the user must define the Safety Network Number (SNN) and ownership to ensure that the safety data is securely and uniquely identified across the network.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1734-OB8S be used in a standard (non-safety) POINT I\/O rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it can physically fit in the rack, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires a Safety Controller (like a GuardLogix) and a safety-rated communication adapter to function. It cannot be controlled by a standard non-safety PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current I can draw at high temperatures?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAt 55°C (131°F), the total module current is typically derated. While the maximum per point is 1.0A at 40°C, always consult the 1734-OB8S derating curves if your enclosure ambient temperature exceeds 45°C to prevent thermal shutdown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support bipolar output wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OB8S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides sourcing outputs. For applications requiring dual-channel (bipolar) switching where one side is sourced and the other is sunk, you would typically pair this with a safety input or use specialized wiring configurations as defined in the Guard I\/O safety manual.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457417769269,"sku":"1734-OB8S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB8S.jpg?v=1773978391"},{"product_id":"allen-bradley-point-i-o-1734-mb-standard-mounting-base","title":"Allen-Bradley POINT I\/O 1734-MB Standard Mounting Base","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the foundational structural component of the Allen-Bradley POINT I\/O system. It serves as the physical housing and backplane interface for all 1734 series I\/O modules. This mounting base is designed to snap directly onto a standard DIN rail, providing the electrical \"bus\" connections that allow data and power to flow between the communication adapter and individual I\/O points. By utilizing a modular design, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for rapid assembly and expansion of distributed I\/O systems, ensuring that modules are securely held and properly aligned within the rack.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a passive component that facilitates the connection between the I\/O module and the Removable Terminal Block (RTB).\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O Mounting Base (Chassis Component)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll POINT I\/O 1734 Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHorizontal or Vertical DIN rail (35mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated POINT I\/O Backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Contacts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Electrical contacts for module-to-backplane interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeyed mechanical placement to prevent incorrect module insertion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Power Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated field-side power bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSnap-on DIN rail attachment with a locking screw for high-vibration security\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRequires a 1734-RTB or 1734-RTBS (sold separately)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.13 lbs (0.06 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard POINT I\/O width (12mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eMechanical Design and Keying\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOne of the critical safety features of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its integrated mechanical keying. Before inserting an I\/O module, the user sets a rotary position on the mounting base that matches the specific module type (e.g., Digital Input, Analog Output, etc.). This ensures that once the base is wired, only a compatible module can be plugged in, preventing accidental hardware damage caused by mismatched voltage levels or signal types.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBackplane and Field Power Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edoes more than just hold the module; it acts as a bridge for two distinct electrical paths:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThe POINTBus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal communication bus that carries data between the modules and the Ethernet or DeviceNet adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThe Field Power Bus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA separate power distribution path that carries 24V DC or 120V AC to the I\/O modules to power field-side devices like sensors and solenoids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis dual-bus architecture allows for \"Daisy Chaining\" power across the entire I\/O rack, significantly reducing the amount of individual power wiring required in the control cabinet.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Best Practices\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be installed starting from the left (next to the communication adapter) and moving to the right. Each base \"interlocks\" with the one to its left, creating a continuous backplane. Once the base is snapped onto the DIN rail, the orange locking screw at the bottom should be tightened to ensure the base remains stationary during module insertion or machine vibration.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-MB include the wiring terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the base housing only. You must also purchase a Removable Terminal Block, such as the 1734-RTB (screw terminals) or 1734-RTBS (spring-clamp terminals), to connect your field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a 1734-MB in the middle of a rack without moving other modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause the mounting bases interlock horizontally to form the backplane, replacing a base usually requires sliding adjacent modules or bases to the side to disengage the internal bus connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a limit to how many 1734-MB bases I can connect together?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe physical limit is typically determined by the communication adapter (e.g., a 1734-AENTR supports up to 63 modules) and the power budget of your 1734-EP24DC expansion power supplies.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457698394421,"sku":"1734-MB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-MB.jpg?v=1773987544"},{"product_id":"1734-oe2v-allen-bradley-point-i-o-2-channel-0-10v-analog-output-module","title":"1734-OE2V | Allen-Bradley POINT I\/O | 2-Channel 0-10V Analog Output Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog output module designed for the Allen-Bradley POINT I\/O platform. This module provides two single-ended, non-isolated voltage outputs, typically used to drive Variable Frequency Drives (VFDs), pressure regulators, or proportional valves that require a standard 0–10V DC control signal. With its 14-bit resolution and rapid conversion rate, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers smooth, granular control for process loops where high-speed response and signal accuracy are critical. Its ultra-compact 12mm width makes it an ideal choice for distributed I\/O racks with limited space.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a high-speed digital-to-analog converter to translate PLC data into precise physical voltage levels.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Channels (Single-ended, Non-isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10 Volts DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e14-Bit (Unipolar)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital-to-Analog (D\/A)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 microseconds per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStep Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 milliseconds to 99% of final value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 milliamps maximum per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal DC Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC nominal (10–28.8V DC range)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA @ 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.0 Watt maximum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.4 BTU\/hour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Format:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSigned Integer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.13 lbs (0.06 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSignal Integrity and Wiring\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eBecause the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures non-isolated, single-ended outputs, both channels share a common return path. To maintain the 14-bit signal integrity and prevent electrical noise from affecting the output, it is essential to use shielded twisted-pair cabling (such as Belden 8761). The shield should be grounded at only one end, typically at the POINT I\/O chassis ground, to avoid ground loops that could introduce offsets into the 0–10V signal.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation and Hardware Requirements\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a \"plug-in\" module that must be seated into a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emounting base. It requires a Removable Terminal Block (RTB), specifically the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-RTB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(screw) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-RTBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(spring), to interface with field wiring. Before installation, the mechanical keying on the mounting base must be set to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePosition 4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure the module is correctly aligned and protected from mismatched voltage levels in the rack.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1734-OE2V be used for -10V to +10V bipolar signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This specific module is designed for unipolar 0–10V DC operation. For bipolar voltage applications, the 1734-OE2C or a specialized bipolar module would be required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I handle the \"Signed Integer\" data format in my logic?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn Studio 5000, the 0–10V output is typically represented by a value range of 0 to 10,000 (or 0 to 16,383 depending on scaling). Using \"Signed Integer\" allows the controller to handle the data with standard math instructions before sending the final value to the module's output register.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the 24V DC field power is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 24V DC field-side power (provided via the power bus in the mounting base) to generate the 0–10V signal. If field power is lost, the \"NODE\" or \"POINT\" status LED will typically flash red, and the outputs will drop to 0V.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457701966133,"sku":"1734-OE2V","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OE2V.jpg?v=1773987753"},{"product_id":"1734-acnr-allen-bradley-point-i-o-controlnet-adapter-module","title":"1734-ACNR | Allen Bradley | POINT I\/O ControlNet Adapter Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-ACNR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance communication interface for the POINT I\/O™ platform. This adapter enables seamless data exchange between a ControlNet network and up to 63 POINT I\/O modules. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, featuring dual BNC connectors to support redundant media topologies. It bridges the gap between your central controller and distributed field devices, ensuring deterministic I\/O performance in complex automation architectures.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe 1734-ACNR manages power distribution and network traffic within the following parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlNet Adapter (Redundant)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC Nominal (10–28.8V DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.0 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.8 Watts @ 28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Amps for 10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e425 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvervoltage Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReverse Polarity Protected\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual (2) ControlNet BNC Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.44 lbs (2.01 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Media Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-ACNR features dual BNC ports. If the primary ControlNet cable sustains damage or signal loss, the adapter instantly switches to the redundant path. This prevents system downtime and maintains continuous process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Power Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn integrated power supply provides 1000 mA of POINTBus current. This capacity allows the adapter to power a significant number of I\/O modules directly from the backplane, reducing the need for additional 1734-EP24DC expansion power supplies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in reverse polarity protection prevents hardware failure during installation errors. The module also handles high inrush currents (up to 6A), ensuring stability during system power-up cycles in large-scale industrial racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Networking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlNet protocol ensures that time-critical I\/O data arrives exactly when the processor expects it. This eliminates network jitter, which is essential for high-speed packaging or assembly lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTool-Free Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps directly onto a standard DIN rail. Its compact vertical orientation saves significant cabinet space, making it ideal for distributed junction boxes where interior room is limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum number of I\/O modules this adapter can support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-ACNR supports up to 63 POINT I\/O modules. However, you must calculate the total current draw to ensure it does not exceed the 1000 mA POINTBus limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit arrive in original factory packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this 1734-ACNR is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It ships in the manufacturer's sealed box with the unique GTIN (10612598283702) and quality control stamps intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this adapter in a non-redundant ControlNet setup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the \"R\" in ACNR stands for Redundant, the module functions perfectly in a single-cable configuration. Simply connect your network to Port A and leave Port B available for future expansion or redundancy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of power supply should I use for the input voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse a regulated 24V DC power supply. Ensure the supply can handle the 6A inrush current to prevent voltage drops during the initial power-on sequence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52476496216373,"sku":"1734-ACNR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-ACNR.jpg?v=1774411116"},{"product_id":"1734-ow2-allen-bradley-point-i-o-2-point-relay-output-module","title":"1734-OW2 | Allen-Bradley | POINT I\/O 2-Point Relay Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OW2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, electromechanical relay output solution within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O 1734\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. This module integrates two independent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eForm A (Normally Open)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erelays, allowing the control of various AC and DC loads in a distributed I\/O architecture. We provide this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock. It bridges the gap between low-level PLC logic and high-power field devices like motor starters, solenoid valves, and indicators while minimizing panel space.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Normally Open (Form A) Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Current Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 A per channel (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 W (Maximum)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Life\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥ 100,000 operations @ rated load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 operation per 3 seconds (0.3 Hz max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22–14 AWG (0.25–2.5 mm²) Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Mixed Loads:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-OW2 handles both AC and DC voltages up to 240V AC or 125V DC. This flexibility eliminates the need for separate interposing relays when controlling diverse field equipment, significantly reducing system complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"POINT\" architecture allows users to add precisely two relay points per module. This prevents the \"over-provisioning\" of I\/O commonly seen with 8 or 16-point cards, lowering the overall cost-per-point in small-scale automation skids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250V continuous isolation protects the sensitive backplane electronics from field-side voltage spikes and electrical noise. This barrier ensures that a catastrophic failure on the load side does not propagate to the PLC processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Maintenance Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a \"T-Base\" terminal system (sold separately), which allows for \"Removal and Insertion Under Power\" (RIUP). Maintenance teams can swap a 1734-OW2 module without disturbing the field wiring or shutting down the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Cold Start Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard commercial electronics, the 1734-OW2 operates down to -20°C. This makes it suitable for unheated enclosures in outdoor applications or cold storage facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1734-OW2 for high-speed switching applications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The electromechanical design limits the switching frequency to 0.3 Hz (one operation every three seconds) at rated load. For high-speed PWM or rapid cycling, utilize a solid-state output module like the 1734-OB8.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must install the 1734-OW2 on a 1734-TB or 1734-TBS terminal base. The base provides the mechanical connection to the DIN rail and the electrical interface to the POINTBus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify the contact health?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module includes a status LED for each output. If the LED illuminates but the field device does not activate, check the external fuse or the continuity of the electromechanical contact using a multimeter during a maintenance cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a factory-sealed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We ship only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Allen-Bradley boxes with intact serial numbers and factory documentation to ensure E-E-A-T compliance for industrial procurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52531796869429,"sku":"1734-OW2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OW2.jpg?v=1775198063"},{"product_id":"allen-bradley-1734-fpd-point-i-o-field-potential-distributor","title":"Allen Bradley 1734-FPD POINT I\/O Field Potential Distributor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-FPD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a critical structural component within the POINT I\/O™ system. This module breaks the field power distribution bus to change the field power source or create a new voltage zone. It allows users to mix various voltage types (AC and DC) or isolate sensitive analog signals from noisy digital circuits within a single I\/O station. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum system integrity for your automation architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table outlines the critical electrical and physical parameters for the 1734-FPD:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eField Potential Distributor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O 1734\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V AC, 12\/24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Input Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePass-Through\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContinuous Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 Volts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Horizontal or Vertical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.44 lbs (0.20 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWiring Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCategory 1 on power ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Zone Segregation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-FPD solves the common industrial challenge of running different voltages on the same rack. It physically interrupts the internal power bus, allowing you to transition from 24V DC to 120V AC without requiring a second communication adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy isolating power groups, the 1734-FPD ensures that a field-side short circuit in one zone does not bring down the power for the entire I\/O assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Current Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 10 Amp maximum rating, this module supports high-density I\/O clusters, reducing the need for additional power feed hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe open-style design snaps directly onto standard DIN rails. It fits seamlessly between I\/O modules, maintaining the slim profile of the POINT I\/O system even in space-constrained enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal base supports a screw torque of 0.6 Nm, ensuring vibration-resistant connections in harsh manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-FPD consume any POINTBus addresses?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-FPD is a non-addressable pass-through module. It does not occupy a node address or communicate with the controller; it strictly manages field power distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I use a 1734-FPD instead of a 1734-EP24DC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse the 1734-FPD to change power sources or types (e.g., switching from AC to DC). Use the 1734-EP24DC (Expansion Power Supply) when the current draw on the POINTBus exceeds the capacity of the adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product shipped in original packaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We provide this Allen Bradley 1734-FPD in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, factory-sealed condition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto meet strict industrial E-E-A-T procurement standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary mounting restriction?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module must reside between I\/O modules on a 1734 terminal base. Always ensure you stay within the 50V continuous isolation limit between adjacent voltage zones.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562185421109,"sku":"1734-FPD","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-FPD.jpg?v=1776049834"},{"product_id":"allen-bradley-1734-vtm-point-i-o-voltage-terminal-module","title":"Allen Bradley 1734-VTM POINT I\/O Voltage Terminal Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-VTM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized expansion component within the POINT I\/O™ ecosystem, providing organized common-voltage connection points for field devices. This module eliminates the need for external terminal blocks, significantly reducing cabinet clutter and wiring complexity. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, ensuring the highest level of electrical safety and signal consistency for your automated processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe following table details the core electrical and physical specifications for the 1734-VTM:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Terminal Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Voltage Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDC Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 – 28.8 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAC Voltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 \/ 240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Module Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.0 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1600 V RMS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eScrew Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWire Size Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 – 14 AWG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.06 lbs (0.03 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Single Slot)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Wiring Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-VTM provides 8 distinct voltage termination points within a single, slim-profile slot. This design effectively consolidates power distribution, allowing engineers to scale I\/O density without expanding the enclosure footprint.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 1600V RMS isolation rating, this module protects sensitive backplane electronics from field-side electrical surges and noise, preventing catastrophic system failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Field Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated screw clamp terminals securely grip wire sizes from 22 to 14 AWG. This flexibility enables rapid field termination and ensures vibration-resistant connections in heavy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirect Bus Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps directly onto the POINT I\/O rail, drawing its power routing through the established bus. This architecture minimizes the physical wiring required between the controller and the terminal interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLightweight Open-Style Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAt only 0.06 lbs, the 1734-VTM adds negligible weight to the DIN rail assembly while its open-style enclosure promotes natural convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-VTM require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1734-VTM installs into a standard POINT I\/O terminal base (such as the 1734-TB or 1734-TBS). Ensure the base matches your specific wiring preference (screw or spring clamp).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1734-VTM for both AC and DC circuits?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports both ranges (120\/240V AC and 10-28.8V DC). However, you must ensure that all points on the specific module utilize the same voltage source to prevent cross-contamination of power types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product a genuine Allen Bradley component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee that every 1734-VTM we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, factory-original equipment\u003c\/strong\u003e. Each unit arrives in its original manufacturer packaging with a verified UPC (612598325993).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum current capacity for the entire module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module supports a total current of 4 Amps. Engineers must calculate the combined draw of all 8 field devices to ensure they do not exceed this thermal and electrical limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562333827381,"sku":"1734-VTM","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-VTM1.png?v=1776050601"},{"product_id":"allen-bradley-1734sc-if4u-point-i-o-universal-analog-input-module","title":"Allen Bradley 1734SC-IF4U POINT I\/O Universal Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734SC-IF4U\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(manufactured by Spectrum Controls for the POINT I\/O™ platform) acts as a highly versatile interface for complex industrial sensing. This \"Universal\" module consolidates multiple input types into a single hardware footprint, supporting Thermocouple, RTD, Resistance, Voltage, and Current signals simultaneously across four channels. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, providing a high-density solution for precision data acquisition in space-constrained environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734SC-IF4U utilizes a high-resolution Sigma-Delta ADC to ensure signal accuracy:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Differential (Individually Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit Sigma-Delta\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Types (Voltage)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±10V, 0-10V, 0-5V, 1-5V, ±100mV, ±50mV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Types (Current)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0-20mA, 4-20mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Types (Temp)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermocouple (J, K, T, E), RTD (PT385\/3916)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V (Continuous) Basic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 W @ 28.8V DC Max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e56 x 12 x 75.5 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Channel Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734SC-IF4U eliminates the need to purchase separate modules for different sensor types. Engineers configure each channel independently, allowing a mix of pressure transmitters (4-20mA) and temperature probes (RTD\/TC) on the same module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe selectable input filters (including 4 Hz and 17 Hz) and Sigma-Delta conversion technology suppress electrical noise and 50\/60 Hz interference, ensuring stable readings in high-EMI factory environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Space Optimization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOccupying only 12mm of width on the POINTBus, this module reduces the physical footprint of the I\/O rack. It replaces up to four dedicated-function modules, significantly lowering hardware costs and enclosure size requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Spare Parts Strategy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintaining one universal module in stock covers almost all analog input requirements for the 1734 platform, drastically reducing inventory overhead and simplifying maintenance logistics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCold Junction Compensation (CJC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes internal CJC for thermocouples, maintaining high accuracy across the entire operating temperature range without requiring external compensation hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal bases are compatible with the 1734SC-IF4U?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module fits into standard 1734-TB or 1734-TBS terminal bases. Ensure you set the mechanical key switch to position 3 before insertion to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both 2-wire and 3-wire RTDs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1734SC-IF4U supports 2, 3, and 4-wire RTD configurations as well as resistance inputs up to 3000Ω, providing maximum flexibility for various sensor types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Allen Bradley\/Spectrum Controls product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We ship only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory stock\u003c\/strong\u003e. Every unit comes in original packaging and meets the strict E-E-A-T standards for industrial procurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a standard 1734-IF4 with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the 1734SC-IF4U provides universal functionality, it requires specific configuration in your PLC software (such as Studio 5000) using the appropriate Add-On Profile (AOP) or generic profile settings to unlock the universal input features.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562408407349,"sku":"1734SC-IF4U","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734SC-IF4U.jpg?v=1776052464"},{"product_id":"allen-bradley-1734-ctm-point-i-o-common-terminal-module","title":"Allen-Bradley 1734-CTM POINT I\/O Common Terminal Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-CTM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a critical termination expansion component within the POINT I\/O 1734 ecosystem. It provides eight additional common terminals to simplify the wiring of high-density I\/O racks. This module specifically targets 3-wire field devices, such as proximity sensors and photoelectric eyes, which require a shared return path. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring low-impedance electrical pathways and long-term connection integrity for your distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-CTM utilizes a passive electrical interface to distribute common power or return signals across the POINT I\/O backplane.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O 1734\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommon Terminal Module (CTM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Shared Common Terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Width:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-slot design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation Method:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlug-in module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBase Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1734-TB, 1734-TBS, 1734-TOP, 1734-TOPS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePassive Internal Termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard 35mm DIN Rail (via Terminal Base)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.06 lbs (0.03 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100% Brand New Original\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Wiring for 3-Wire Sensors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMost standard POINT I\/O modules provide limited termination points. The 1734-CTM provides eight dedicated common terminals, allowing engineers to wire 3-wire sensors directly to the I\/O stack without installing bulky external terminal strips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignificant Panel Space Savings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating common distribution into the I\/O rack, this module eliminates the need for separate DIN-rail-mounted terminal blocks. This reduction in hardware footprint allows for smaller enclosure designs or increased I\/O density within existing cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUsing the 1734-CTM organizes field wiring into logical groups. Technicians can identify and isolate common-path issues quickly because the module centralizes the shared connections for a specific set of I\/O points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Base Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module plugs into standard 1734-TB, 1734-TBS, 1734-TOP, or 1734-TOPS bases. This cross-compatibility ensures that you can add common termination points anywhere in the POINT I\/O assembly without purchasing specialized mounting hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-CTM require any software configuration in Studio 5000?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-CTM is a passive electrical module. It does not communicate data over the backplane and does not require an entry in the I\/O configuration tree. It acts strictly as a physical wiring interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1734-CTM for both AC and DC common signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module’s passive design allows it to carry the voltage level supplied to its common bus. However, you must ensure all devices connected to a single 1734-CTM share the same voltage potential to prevent short circuits or equipment damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1734-CTM and the 1734-VTM?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-CTM provides \"Common\" terminals (typically for the negative or neutral side of a circuit), while the 1734-VTM (Voltage Terminal Module) provides \"Voltage\" terminals (typically for the positive or hot side). Systems often use them in pairs to support 3-wire sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a \"Hot-Swap\" component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O system supports Removal and Insertion Under Power (RIUP). You can install or remove the 1734-CTM from its base while the rest of the system is powered, provided you follow standard safety procedures for field-side wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52587853906229,"sku":"1734-CTM","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-CTM.jpg?v=1776409879"},{"product_id":"1734-485asc-allen-bradley-point-i-o-rs-422-rs-485-ascii-interface-module","title":"1734-485ASC | Allen-Bradley POINT I\/O RS-422\/RS-485 ASCII Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-485ASC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized character-based serial interface within the POINT I\/O family. It bridges the gap between RS-422\/RS-485 peripheral devices and the Logix control architecture. This module enables the PLC to send and receive ASCII strings to and from devices such as barcode scanners, weigh scales, and vision sensors. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your distributed I\/O system maintains precise data synchronization and serial timing without the risks associated with used or refurbished hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-485ASC utilizes the compact POINT I\/O backplane to deliver efficient serial-to-network data conversion.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePOINT I\/O (1734)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Standards:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-422 and RS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eASCII (Character-based)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDefault Buffer Size:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 bytes Tx \/ 20 bytes Rx\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBuffer Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUser-configurable via software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminator Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnd-of-string character detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail grounded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUses 1734-TB or 1734-TBS Removable Terminal Base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects via POINT I\/O adapter (EtherNet\/IP, ControlNet, or DeviceNet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.13 lbs (0.06 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless ASCII String Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles character-based messaging natively. This offloads the intensive task of bit-level serial parsing from the main controller CPU, allowing the PLC to focus on primary logic execution while the 1734-485ASC manages the serial buffer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Buffer Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the module defaults to a 20-byte buffer, engineers can adjust the Tx\/Rx sizes to match the specific data packet requirements of the field device. This flexibility prevents data truncation and ensures the successful transmission of long ASCII strings common in labeling and tracking systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting RS-422 and RS-485 differential signals over shielded cabling, the 1734-485ASC operates reliably in high-EMI environments. The DIN rail grounding method provides a low-impedance path for electrical noise, protecting the serial data stream from distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Maintenance Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps onto a removable terminal base (RTB). This allows maintenance teams to replace the electronics without disconnecting any field wiring, significantly reducing the Mean Time to Repair (MTTR) during scheduled or emergency maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent String Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports \"End-of-string\" terminators. It automatically identifies the end of a message based on a user-defined character, ensuring the controller receives a complete and clean data packet for immediate processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1734-485ASC for Modbus RTU communication?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 1734-485ASC specifically supports character-based ASCII messaging. Modbus RTU requires a different protocol handler (such as the 1734-232ASC or a dedicated ProSoft module) that supports binary data frames and CRC error checking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You must install the 1734-485ASC onto a 1734-TB or 1734-TBS terminal base. Note that the terminal base is a separate component and does not ship with the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the baud rate and parity settings?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou configure all serial parameters—including baud rate, parity, stop bits, and data bits—within the Studio 5000 (Logix Designer) I\/O configuration profile for the module. Changes take effect as soon as you download the configuration to the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine, factory-original unit?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWe guarantee that every 1734-485ASC we provide is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It ships in factory-sealed packaging with the original UPC (612598302352) intact, ensuring you receive the full industrial lifespan and performance specified by Allen-Bradley.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52591529591093,"sku":"1734-485ASC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-485ASC.jpg?v=1776415345"},{"product_id":"1734-tbs-point-i-o-spring-clamp-terminal-base-unit-allen-bradley","title":"1734-TBS | POINT I\/O Spring-Clamp Terminal Base Unit | Allen Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the critical mounting and wiring foundation for the POINT I\/O system. This terminal base unit provides the physical interface and electrical backplane connection for 1734 series I\/O modules. It features a spring-clamp mechanism that ensures permanent contact tension without the need for periodic re-tightening. We supply this component as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, guaranteeing structural integrity and optimal conductivity for your distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-TBS provides a high-density wiring solution with the following mechanical and environmental parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O (1734)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpring-Clamp\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Terminals\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 55 °C (-4 to 131 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 G @ 10 to 500 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Style (IP20)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 lbs (0.11 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-TBS addresses specific installation challenges in modern control cabinet design through its specialized clamping technology:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration-Proof Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe spring-clamp design maintains constant pressure on the wire. Unlike traditional screw terminals that loosen under mechanical stress, this unit prevents intermittent signal loss in high-vibration applications such as stamping presses or conveyor systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Wiring Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis terminal base significantly reduces assembly time. Technicians insert wires directly using a small screwdriver to actuate the spring, eliminating the time-consuming process of torquing individual screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Maintenance (RIUP):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-TBS supports \"Removal and Insertion Under Power\" (RIUP). Engineers replace faulty I\/O modules by simply unplugging them from the base; the wiring remains undisturbed on the 1734-TBS, which maintains system uptime and prevents cross-wiring errors during field service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim design maximizes DIN rail density. It allows engineers to pack high-channel counts into restricted enclosure spaces without sacrificing accessibility or thermal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1734-TBS with any POINT I\/O module?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The 1734-TBS accommodates a wide range of digital and analog POINT I\/O modules. However, always verify that your specific module's current requirements and voltage levels align with the 8-terminal configuration of this base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main benefit of spring-clamp over the 1734-TB screw-type base?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-TBS (Spring-Clamp) eliminates the need for periodic torque maintenance. In environments with thermal cycling or vibration, screws can back out; the spring mechanism in the TBS model self-adjusts to maintain a gas-tight connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I properly ground the 1734-TBS?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe terminal base snaps onto the DIN rail, which establishes the chassis ground. Ensure the DIN rail itself connects to a low-impedance earth ground to provide proper shielding and noise immunity for the installed I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this base include the removable terminal block (RTB)?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-TBS consists of the base and the integral spring-clamp terminal assembly. This one-piece design ensures the wiring interface stays locked to the backplane, providing a more stable mechanical connection than two-piece pluggable alternatives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52767116689717,"sku":"1734-TBS","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-MB_664914eb-d42b-4eb7-84ad-6262b7cfcfd9.jpg?v=1776736105"},{"product_id":"1734-4iol-allen-bradley-point-i-o-4-channel-io-link-master-module","title":"1734-4IOL | Allen Bradley POINT I\/O 4-Channel IO-Link Master Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-4IOL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance IO-Link master module within the POINT I\/O family. This module bridges the gap between the controller and smart field devices, providing four dedicated channels for bidirectional communication. It enables users to harness advanced diagnostics and parameterization at the sensor\/actuator level. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring seamless integration into your EtherNet\/IP or DeviceNet distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-4IOL provides digitized field data and robust power distribution for smart factory applications:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O (1734)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIO-Link Master\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIO-Link (Point-to-Point)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Handling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCyclic and Acyclic Data Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Orientation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal or Vertical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 lbs (0.12 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Base Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-TB, 1734-TBS, 1734-TOP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-4IOL addresses the critical requirements of Industry 4.0 and complex machine diagnostics:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Device Health Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module extracts comprehensive diagnostic data from IO-Link enabled sensors. It detects conditions like lens soiling or internal temperature spikes before a failure occurs, shifting maintenance from reactive to predictive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Device Configuration (ADC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-4IOL stores the configuration parameters of connected sensors. When a technician replaces a damaged sensor, the master module automatically downloads the settings to the new device, eliminating manual setup errors and reducing downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Wiring Simplification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes standard 3-wire unshielded cables for intelligent communication. This replaces expensive specialized cables and reduces the overall complexity and cost of the control cabinet wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Process Insights:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBeyond simple On\/Off signals, the 1734-4IOL transmits precise process values (such as exact distance measurements or pressure levels) as digital data, preventing signal degradation caused by electromagnetic interference (EMI) in analog circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use standard digital sensors with the 1734-4IOL?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each channel on the 1734-4IOL supports standard I\/O (SIO) mode. You can connect traditional 24V DC digital sensors to any channel, providing a flexible migration path from standard I\/O to smart IO-Link technology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal base is best for the 1734-4IOL?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend the 1734-TB or 1734-TBS base. Ensure you utilize the 8-terminal configuration to provide adequate power distribution for both the module electronics and the connected field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support \"Removal and Insertion Under Power\" (RIUP)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Like other POINT I\/O modules, the 1734-4IOL allows for replacement while the rest of the system remains operational. This feature is critical for continuous process industries where shutting down the entire I\/O rack is not an option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 1734-4IOL handle power to the sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws 24V DC from the POINT I\/O backplane power bus. It distributes this power to the connected IO-Link devices through the L+ and L- pins, supporting up to the maximum rated current per port as specified in the technical manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52767156994357,"sku":"1734-4IOL","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-4IOL.jpg?v=1776736548"},{"product_id":"allen-bradley-1734-ir2e-point-i-o-2-channel-rtd-input-module","title":"Allen Bradley 1734-IR2E POINT I\/O 2-Channel RTD Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-IR2E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-precision analog input expansion for the POINT I\/O platform. It specializes in converting resistance signals from RTD (Resistance Temperature Detector) sensors into digital data for the controller. This module provides two independent channels for critical temperature monitoring in distributed I\/O architectures. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring high-accuracy thermal feedback for your process control loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IR2E utilizes high-resolution conversion technology to maintain signal integrity:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O (1734)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog RTD Input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 High-Resolution Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigned Integer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 Watt\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.3 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to 55°C (-4°F to 131°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IR2E solves specific thermal measurement challenges in high-density control cabinets:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Signal Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution detects minute resistance changes, allowing the PLC to monitor temperature fluctuations with laboratory-grade accuracy. This precision prevents overshoot in sensitive heating or cooling applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEffective Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital filtering and 50V continuous isolation protect the low-voltage RTD signals from electromagnetic interference (EMI) generated by nearby variable frequency drives (VFDs) and motor starters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Mechanical Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware utilizes a physical keyswitch at position 6. This mechanical lock prevents the insertion of incorrect module types into the terminal base, shielding the system from accidental voltage damage during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module dissipates only 1.0 Watt of power. This low thermal footprint prevents heat buildup in compact distributed I\/O enclosures, extending the lifespan of adjacent electronic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich RTD sensor types does the 1734-IR2E support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module supports standard 100-ohm Platinum (Pt) RTDs and various other resistance-based sensors. You must configure the specific sensor type (e.g., Pt 385 or Pt 3916) within the Studio 5000 or RSLogix 5000 software environment to ensure correct scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IR2E installs into 1734-TB, 1734-TBS, or 1734-TOP terminal bases. Ensure the base is properly grounded to the DIN rail to maximize the noise rejection capabilities of the 16-bit converter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the \"Signed Integer\" data format work for temperature?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module converts the analog resistance into a signed integer value. The PLC then scales this integer into engineering units (Celsius or Fahrenheit) based on the configuration profiles, providing direct temperature readouts to the HMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if an RTD wire breaks during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IR2E features integrated open-circuit detection. When a wire breaks or a sensor fails, the module flags a diagnostic error to the PLC, allowing the system to trigger a safe-state shutdown or alarm immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52767166955829,"sku":"1734-IR2E","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IR2E.jpg?v=1776737621"},{"product_id":"1734-ob2ep-allen-bradley-point-i-o-digital-dc-sourcing-protected-output-module","title":"1734-OB2EP | Allen-Bradley POINT I\/O Digital DC Sourcing Protected Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OB2EP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance digital output interface within the POINT I\/O family. This module provides two sourcing output channels at 24V DC, allowing a PLC to drive field actuators, solenoids, and motor starters. Unlike standard modules, the \"EP\" designation indicates advanced electronic protection, which safeguards the hardware against short circuits and overcurrent conditions. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring peak electrical resilience and immediate integration into your distributed I\/O architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital DC Sourcing Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Output Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Amps per module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePOINTBus Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e75 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated short-circuit and overload protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.4 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e11.6 BTU\/hour\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.13 lbs (0.06 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-OB2EP solves critical operational challenges by merging a compact footprint with intelligent power management:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Circuit Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe electronic protection mechanism monitors load conditions in real-time. It detects short circuits or excessive current draws and shuts down the affected channel instantly, preventing permanent damage to the module and reducing the risk of control-side electrical fires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Current Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDespite its small size, the module manages up to 4 Amps of total current. This high capacity allows engineers to drive larger loads directly without the need for interposing relays, saving significant cabinet space and reducing hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEfficient Thermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module limits thermal dissipation to 11.6 BTU\/hour. This low heat output prevents temperature buildup in dense I\/O racks, extending the lifespan of adjacent analog or communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-OB2EP supports Removal and Insertion Under Power (RIUP). Maintenance teams can replace a module without powering down the entire POINT I\/O rack, drastically reducing MTTR (Mean Time To Repair) during critical production windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the 1734-OB2EP different from the standard 1734-OB2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-OB2EP includes \"Electronic Protection\" (EP). While the standard OB2 relies on external fusing, the OB2EP features internal circuitry that automatically handles short circuits and overloads, providing a more robust safety layer for the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1734-OB2EP installs onto a 1734 terminal base, such as the 1734-TB or 1734-TBS. The terminal base provides the field wiring connections and the backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a Brand New original product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee that this 1734-OB2EP is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand original. Using new components ensures that the electronic protection circuits have never been stressed by previous field faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I reset the electronic protection if a fault occurs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOnce you clear the external short circuit or overload, the module typically requires a power cycle or a software reset through the controller to resume normal operation, depending on your specific Logix configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52768869122357,"sku":"1734-OB2EP","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB2EP.jpg?v=1776751805"},{"product_id":"1734-ssi-point-allen-bradley-i-o-synchronous-serial-interface-encoder-module","title":"1734-SSI POINT | Allen-Bradley | I\/O Synchronous Serial Interface Encoder Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-SSI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision interface module within the POINT I\/O system, specifically designed to process data from absolute encoders. This module utilizes the Synchronous Serial Interface (SSI) protocol to provide accurate position feedback for motion control applications. It handles complex data in Little Endian format, ensuring seamless integration with Logix-based controllers. We provide this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring the signal integrity and timing accuracy required for high-speed industrial positioning.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSynchronous Serial Interface (SSI) Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEncoder Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAbsolute Encoder\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 Channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Format:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLittle Endian\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupported via DeviceNet or other POINT I\/O adapters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eKeyswitch Position:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePosition 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 40°C (32 to 104°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Altitude:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1000 meters above sea level\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.25 lbs (0.11 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Status Indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-SSI solves critical motion feedback challenges through specialized hardware architecture:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Position Errors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe SSI protocol provides absolute position data without requiring a \"home\" sequence. The module maintains position integrity even after a power cycle, preventing machine crashes and reducing startup time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSynchronous Data Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module synchronizes the clock and data signals, effectively eliminating transmission jitter. This provides the controller with stable, high-resolution feedback even in systems with rapid acceleration and deceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified DIN Rail Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe open-style, compact design snaps directly onto standard DIN rails. This reduces the footprint of the feedback system, allowing engineers to pack more functionality into smaller control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Diagnostic Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated status indicators provide real-time visual feedback on module power and communication health. This feature simplifies onsite troubleshooting, allowing technicians to identify signal faults without connecting external diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-SSI require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The 1734-SSI module requires a 1734 terminal base (such as the 1734-TB or 1734-TBS). Ensure you set the keyswitch to Position 2 before inserting the module to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with an incremental encoder?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-SSI is specifically designed for absolute encoders using the Synchronous Serial Interface. For incremental encoders, you should select a high-speed counter module like the 1734-VHSC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this unit a Brand New original product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee this 1734-SSI is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein its original factory packaging. Using brand-new encoder modules is critical for ensuring timing components meet original precision tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Little Endian format affect my programming?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Little Endian format dictates the byte order of the incoming encoder data. Most modern Allen-Bradley controllers handle this format natively, simplifying the configuration of your tags and motion scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52768932266293,"sku":"1734-SSI","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-SSI.jpg?v=1776753147"},{"product_id":"allen-bradley-1734-ie4c-point-i-o-4-channel-analog-current-input-module","title":"Allen-Bradley 1734-IE4C POINT I\/O 4-Channel Analog Current Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-IE4C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density analog input solution within the POINT I\/O family. This module converts analog current signals from field devices—such as pressure transmitters, flow meters, and temperature sensors—into digital values for the controller. It supports both 0–20 mA and 4–20 mA input ranges across four single-ended channels. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your distributed I\/O architecture maintains the precise signal calibration and thermal stability required for high-stakes industrial processing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Single-Ended Current Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA or 0–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAbsolute Accuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1% Full Scale @ 25°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta-Sigma\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigned Integer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 Ohms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-120 dB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eKeyswitch Position\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePosition 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.06 lbs (0.03 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Delta-Sigma Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-IE4C utilizes Delta-Sigma analog-to-digital conversion. This technology oversamples the input signal to filter out high-frequency noise, delivering an absolute accuracy of 0.1% for sensitive process measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA common mode rejection ratio of -120 dB allows the module to maintain signal integrity even in environments characterized by heavy electromagnetic interference. This rejection prevents ground loop noise from corrupting the 4-20 mA data stream.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Optimized High Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module packs four independent channels into a ultra-slim POINT I\/O form factor. This high-density design significantly reduces the required DIN rail length in overcrowded control cabinets without sacrificing thermal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated status indicators provide immediate visual feedback regarding the module's health and network status. These LEDs allow maintenance teams to identify channel-specific faults or power issues at a glance, shortening troubleshooting windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I prevent damage during installation?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eEnsure you set the keyswitch on the 1734-TB or 1734-TBS terminal base to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePosition 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebefore inserting the module. This mechanical interlock prevents the accidental insertion of the wrong module type into a wired base, protecting both the module and the field wiring from overvoltage conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external calibration?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eThe 1734-IE4C comes factory-calibrated to maintain 0.1% full-scale accuracy. Under normal operating conditions, the Delta-Sigma converter compensates for minor thermal drift. For ISO-certified environments, we recommend a yearly verification of the input loop rather than manual adjustment of the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a \"New Surplus\" or \"Open Box\" unit?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eWe guarantee this 1734-IE4C is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It arrives in its original factory-sealed Allen-Bradley packaging. This ensures the unit has never been mounted and carries the full mechanical integrity of the gold-plated backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 60 Ohm input impedance?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003c\/span\u003eThe low 60 Ohm impedance minimizes the voltage drop across the input module. This allows for longer cable runs between the field transmitter and the POINT I\/O rack, as it leaves more \"voltage overhead\" for the transmitter to operate effectively on a standard 24V DC loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52774565380405,"sku":"1734-IE4C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IE4C.jpg?v=1776830449"},{"product_id":"1734-ob4-point-i-o-4-point-24v-dc-digital-sourcing-output-module-allen-bradley","title":"1734-OB4 POINT I\/O 4-Point 24V DC Digital Sourcing Output Module | Allen-Bradley","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1734-OB4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-efficiency discrete output interface within the POINT I\/O distributed system architecture. This module provides four sourcing-type outputs to drive 24V DC field devices such as solenoids, contactors, and indicator lights. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your automated lines benefit from factory-fresh electronic protection and the ultra-compact form factor characteristic of the POINT I\/O series.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Sourcing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 A per point (3.0 A max per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectronic Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Overload and Short Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.2 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 BTU\/hr\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Yellow (Output), 2 Red\/Green (Module\/Network)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Wiring Base\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-TB or 1734-TBS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eActive Electronic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-OB4 incorporates internal short-circuit and overload protection. This circuitry detects faults instantaneously and shuts down the affected channel to prevent hardware damage, eliminating the need for external fusing for each output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Status Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix dedicated LED indicators provide rapid troubleshooting. Four yellow LEDs track individual output states, while two bi-color LEDs monitor module health and network connectivity, allowing maintenance teams to isolate faults without connecting a programming terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Saving Vertical Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim 12.5mm width maximizes DIN rail density. This design allows engineers to install high point counts in extremely narrow control cabinets, effectively solving the \"space-premium\" challenge in modern machine builds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Support (RIUP):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports Removal and Insertion Under Power (RIUP) when used with the 1734-TB base. This allows for the replacement of modules without disrupting the communication or power of the remaining I\/O on the rack, minimizing system downtime during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does \"Sourcing Output\" mean for my wiring configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn a sourcing configuration, the 1734-OB4 supplies the +24V DC power to the load. You must connect the other side of your field device (solenoid, relay coil, etc.) to the DC common (ground).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this 1734-OB4 unit a refurbished or surplus module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. We guarantee this unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It arrives in the original factory-sealed Allen-Bradley packaging. Using brand new modules is critical for output modules to ensure the internal power transistors have not been degraded by previous short-circuit events.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which terminal base should I use for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYou should mount the 1734-OB4 on a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(spring clamp) wiring base assembly. The base remains permanently wired on the DIN rail, allowing the 1734-OB4 module to snap into place for easy installation and replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the electronic protection reset after a short circuit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnce you remove the short circuit from the field wiring, you can reset the electronic protection by cycling the output point through the controller software or by cycling power to the module. This eliminates the manual labor associated with replacing blown physical fuses.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52774796951861,"sku":"1734-OB4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB4.jpg?v=1776841670"},{"product_id":"allen-bradley-1734-im4-point-i-o-220v-ac-digital-input-module","title":"Allen Bradley 1734-IM4 POINT I\/O 220V AC Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-IM4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a compact, 4-point digital AC input module within the POINT I\/O™ family. It monitors high-voltage discrete signals from field devices such as limit switches, push buttons, and motor starter contacts. This module excels in space-constrained cabinets where distributed I\/O architecture reduces wiring costs. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring seamless integration into your existing 220V control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IM4 provides precision monitoring for high-voltage AC circuits:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e159V AC to 264V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.3 kΩ (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHardware Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Filter\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable (0–65 ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTBus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA @ 5V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.4 BTU\/h (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IM4 addresses critical electrical and spatial challenges in industrial automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe slim design minimizes DIN rail usage. This allows engineers to deploy significant I\/O counts in small junction boxes or remote cabinets where traditional PLC chassis would not fit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA 20ms hardware filter coupled with a programmable digital filter eliminates signal chatter. This prevents electrical noise common in 220V industrial environments from triggering false logic states in the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Heat Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a maximum thermal dissipation of only 3.4 BTU\/h, the 1734-IM4 prevents hotspots within dense I\/O racks. This design extends the life of adjacent electronic components by maintaining a stable ambient temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Mounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps directly into 1734-TB, TBS, or TOP terminal bases. This modularity allows for \"wiring-before-insertion,\" enabling technicians to complete field wiring before installing the sensitive electronic module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support 110V AC inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-IM4 is specifically designed for 220V AC circuits with a minimum \"On-State\" threshold of 159V AC. For 110V AC applications, you must use the 1734-IA series modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a module under power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O system supports Removal and Insertion Under Power (RIUP). You can swap the 1734-IM4 without interrupting the backplane communication of other modules, though you must follow standard safety protocols for the 220V field-side wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the condition of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe supply only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal Allen Bradley stock. The unit ships in its factory box with the original UPC (612598347148) and all factory documentation included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs a terminal base included with the 1734-IM4?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-IM4 is the electronic module only. You must purchase a compatible terminal base, such as the 1754-TB or 1734-TBS, separately if you are performing a new installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52792735334709,"sku":"1734-IM4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IM4.png?v=1777348792"},{"product_id":"allen-bradley-1734-iv8-point-i-o-8-point-24v-dc-sourcing-input-module","title":"Allen Bradley 1734-IV8 POINT I\/O 8-Point 24V DC Sourcing Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-IV8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital input module within the POINT I\/O™ family. This module provides eight sourcing-type input points, allowing for seamless integration of 24V DC field devices such as proximity sensors, limit switches, and photoelectric eyes. Its ultra-compact, modular design minimizes panel space while providing granular I\/O expansion for distributed control architectures. We supply this unit in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, ensuring maximum signal integrity and backplane compatibility for your Logix-based control systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IV8 delivers precise digital signal detection across the following parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O (1734)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Digital (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Input Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTbus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50V (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Yellow I\/O Status LEDs; 1 Green\/Red Module Status\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Horizontal or Vertical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.06 lbs (0.03 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IV8 addresses critical spatial and diagnostic challenges in modern automation:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe \"Point\" architecture allows for 8 discrete inputs in a housing less than 13mm wide. This compact scale enables significant I\/O expansion in small junction boxes or crowded control cabinets where traditional rack-based I\/O is physically impossible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSourcing Input Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module utilizes a sourcing (PNP-compatible) input structure. It provides a common ground for the field devices, simplifying the wiring of 3-wire PNP sensors and reducing the need for additional terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Visual Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated LED indicators provide instantaneous feedback for each of the 8 points. Technicians can identify faulty field devices or broken wires at a glance without utilizing a programming terminal, significantly reducing Mean Time to Repair (MTTR).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Mounting and Assembly:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps onto a 1734-TB or 1734-TBS terminal base. This \"Removal and Insertion Under Power\" (RIUP) capability allows for module replacement without disturbing the field wiring or interrupting the power to other modules on the same DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1734-IB8 and the 1734-IV8?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IB8 is a sinking input module (requires sourcing sensors), whereas the 1734-IV8 is a sourcing input module (requires sinking sensors). Always verify the output type of your field devices (PNP vs. NPN) before selecting the module to ensure electrical compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich terminal base does the 1734-IV8 require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis module installs onto a 1734-TB, 1734-TBS, or 1734-TOP terminal base. The base provides the connection points for field wiring and secures the module to the DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace this module while the system is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O system supports RIUP (Removal and Insertion Under Power). You can remove and replace the 1734-IV8 module while the rest of the I\/O system remains operational, provided you follow standard industrial safety procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine, factory-sealed Allen Bradley unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee the unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. Every 1734-IV8 ships in its original factory packaging with the authentic UPC (612598309832) and Rockwell Automation quality inspection seals intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52793267585333,"sku":"1734-IV8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IV8.png?v=1777359940"},{"product_id":"allen-bradley-1734-ib8k-point-i-o-8-point-sink-digital-dc-input-module","title":"Allen Bradley 1734-IB8K POINT I\/O 8-Point Sink Digital DC Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-IB8K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a high-density digital input module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. This module interfaces with field-side sensors and switches, converting 24V DC sinking signals into logic-level data for the controller. The \"K\" designation signifies a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebuild, providing superior resistance against environmental contaminants. We guarantee this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory equipment, ready for immediate deployment in distributed I\/O architectures.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital DC Input Module (Sinking)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVoltage Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (Horizontal or Vertical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Style (IP20)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–28.8V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.04 lbs (0.018 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe conformal coating protects internal circuitry from moisture, salt spray, and corrosive chemical vapors. This hardware enhancement extends the service life of the module in wastewater treatment plants, oil rigs, and chemical processing facilities where standard modules often fail due to oxidation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGranular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ultra-compact POINT I\/O footprint allows you to add I\/O in increments of 8 points. This modularity reduces hardware waste and minimizes panel space requirements compared to traditional, bulkier PLC racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Troubleshooting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBright LED indicators on the front housing provide instant visual feedback for module status and individual point activity. This feature allows maintenance teams to isolate wiring faults or sensor failures without connecting a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Installation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module snaps directly onto the 1734-TB or 1734-TBS terminal base. This \"Remove and Insertion Under Power\" (RIUP) capability—when following proper safety protocols—shortens mean time to repair (MTTR) by allowing module swaps without dismantling the entire I\/O stack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1734-IB8 and the 1734-IB8K?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IB8K includes a conformal coating on the internal PC board. Electrically, they function identically, but the \"K\" version offers necessary protection for harsh, humid, or corrosive industrial atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You must install the 1734-IB8K onto a 1734-TB, 1734-TBS, or 1734-TOP terminal base. Ensure you set the mechanical keying on the base to position 1 before inserting the module to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix conformal coated and non-coated modules in the same rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, the POINT I\/O backplane supports a mix of module types. However, for maximum system reliability in harsh environments, engineers typically specify conformal coating for all components within the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product factory sealed?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We sell only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits in original Allen Bradley packaging. Each module includes the original factory seal, ensuring it has never been used or refurbished.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52804866998581,"sku":"1734-IB8K","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IB8K.png?v=1777534413"},{"product_id":"1734-ob8k-allen-bradley-point-i-o-8-point-sourcing-24v-dc-digital-output-module","title":"1734-OB8K | Allen Bradley | POINT I\/O 8-Point Sourcing 24V DC Digital Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1734-OB8K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-density digital output interface within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePOINT I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem. This module switches 24V DC sourcing signals to drive field devices such as solenoids, contactors, and actuators. Featuring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating\u003c\/strong\u003e, the 1734-OB8K provides enhanced protection for internal circuitry against harsh industrial atmospheres. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory equipment, ensuring maximum uptime for your distributed control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePOINT I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital DC (Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC (10–28.8V DC Range)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0A per point (3.0A max per module)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConformal Coated PC Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail (via Terminal Base)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.04 lbs (0.018 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Style (IP20)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Corrosion Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe conformal coating shields the 1734-OB8K from moisture, salt spray, and airborne chemical contaminants. This hardware-level protection prevents short circuits and trace degradation in aggressive environments like pulp and paper mills or marine applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-Efficient Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe ultra-slim POINT I\/O profile occupies minimal horizontal space on the DIN rail. This allows engineers to deploy localized I\/O at the point of control, significantly reducing the amount of field wiring returning to the main control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLocal status indicators on the front panel provide real-time feedback for module health and individual output status. Technicians identify faults immediately without opening software, accelerating the troubleshooting process on the factory floor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734-OB8K snaps onto a standard terminal base (1734-TB or 1734-TBS). This modularity allows for the \"Removal and Insertion Under Power\" (RIUP) of the module, enabling system maintenance without disrupting the power to the rest of the I\/O bank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"K\" suffix represent in the 1734-OB8K part number?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"K\" designates that the module features a factory-applied conformal coating. While it remains electrically identical to the standard 1734-OB8, the coating adds a layer of chemical and moisture protection for hazardous or corrosive industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module include the terminal base for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1734-OB8K is the plug-in module only. You must install it into a 1734-TB, 1734-TBS, or 1734-TOP terminal base. Ensure the mechanical keying on the base matches the module requirements before insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1734-OB8K drive 24V DC solenoids directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The sourcing outputs provide up to 1.0A per point, which handles most standard industrial solenoids and relay coils. Always verify that the total module current draw does not exceed the 3.0A limit across all 8 points simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product an original factory-sealed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. We guarantee that every 1734-OB8K we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the original manufacturer’s packaging. We do not sell used, refurbished, or open-box surplus items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52804872634677,"sku":"1734-OB8K","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OB8K.png?v=1777534668"},{"product_id":"1734sc-ie4ch-allen-bradley-point-i-o-4-channel-analog-hart-input-module","title":"1734sc-IE4CH | Allen-Bradley | POINT I\/O 4-Channel Analog HART Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734sc-IE4CH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized high-density analog input module for the Allen-Bradley POINT I\/O platform. It provides four channels of 4-20mA analog input while simultaneously enabling HART (Highway Addressable Remote Transducer) protocol communication. This module allows engineers to extract secondary process variables and device diagnostics directly from smart field instruments without additional hardware. We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and factory-original\u003c\/strong\u003e, ensuring full hardware integrity for your mission-critical process loops.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThis module features high-resolution conversion and robust electrical isolation to maintain signal purity in industrial environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Analog + HART Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART Variables\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePV, SV, TV, FV (Primary, Secondary, Tertiary, Quaternary)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 0.1% of range (0 °C to 25 °C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Ohms (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSampling Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e33 ms (@480 Hz) to 488 ms (@50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOvercurrent Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 mA Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50 VDC Field-to-Backplane \/ 10 VDC Channel-to-Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHART Data Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1734sc-IE4CH captures advanced diagnostic data and multi-variable information from smart transmitters. This capability enables predictive maintenance by monitoring device health and secondary process parameters (TV\/FV) over the existing 4-20mA wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16-bit resolution ensures granular data acquisition for sensitive applications. It detects minute fluctuations in process variables, allowing the controller to execute more precise adjustments in closed-loop systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Channel Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10 VDC channel-to-channel isolation minimizes ground loop interference and prevents signal \"crosstalk\" between adjacent inputs. This ensures that a fault on one instrument does not corrupt the data from the remaining three channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Single-Slot Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module fits into a standard POINT I\/O base. It provides four HART-enabled channels in a single slot width, maximizing I\/O density in small junction boxes and reducing overall cabinet hardware costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734sc-IE4CH require a specific terminal base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module installs into any standard 1734-TB or 1734-TBS terminal base. Ensure the base remains correctly keyed to the analog input module to prevent incorrect module insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module for standard 4-20mA signals without HART?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module functions as a high-precision 16-bit analog input module for standard 4-20mA transmitters. You can enable or disable the HART communication features via the software configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 1734sc-IE4CH handle field-side power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws backplane power for its internal logic, but you must provide field-side power to your 4-20mA transmitters. Verify that your power supply maintains the required voltage for the 250 Ohm typical impedance of each channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software environment supports the HART variables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure the 1734sc-IE4CH using Studio 5000 Logix Designer. The HART variables (PV, SV, TV, FV) map directly into the controller's tag database for easy access in your control logic or HMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52846896677173,"sku":"1734sc-IE4CH","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734SC-IE4CH.png?v=1778211401"},{"product_id":"1734-it2i-allen-bradley-point-i-o-2-channel-isolated-thermocouple-input-module","title":"1734-IT2I | Allen-Bradley | POINT I\/O 2-Channel Isolated Thermocouple Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-IT2I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-precision temperature sensing within the Allen-Bradley POINT I\/O family. This module accepts millivolt signals from thermocouples and converts them into digital temperature data for the controller. It features two individually isolated channels, making it the ideal choice for applications where ground loops or electrical noise threaten signal integrity. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and factory-original\u003c\/strong\u003e, ensuring your thermal loops maintain laboratory-grade accuracy in rugged industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1734-IT2I utilizes advanced delta-sigma conversion to deliver stable, high-resolution data even in electrically \"dirty\" environments.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThermocouple (Multiple Types Supported)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Resolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15-bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDifferential\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConversion Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDelta-Sigma\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Isolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndividually Isolated (Channel-to-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOpen-Wire Detection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePOINTbus Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e175 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSigned Integer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.13 lbs (0.06 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndividual channel-to-channel isolation prevents common-mode noise and ground loop currents from affecting temperature readings. This hardware architecture allows you to connect sensors located in different parts of a machine without worrying about voltage potential differences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Precision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 15-bit delta-sigma converter filters out high-frequency interference. It delivers granular data that allows the PID loop to maintain tighter temperature tolerances, directly improving product quality in plastic extrusion, heat treating, or food processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePredictive Maintenance with Open-Wire Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module immediately identifies a broken thermocouple wire or a disconnected sensor. It sends a specific fault code to the controller, enabling the system to trigger a safe shutdown or alarm before process deviations occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLike other POINT I\/O modules, the 1734-IT2I supports Removal and Insertion Under Power (RIUP). You can replace a module without powering down the entire I\/O rack, significantly reducing downtime during routine maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1734-IT2I require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The module draws its operating power directly from the POINTbus. However, you must calculate the total current draw (175 mA for this module) to ensure your 1734-PDN or adapter power supply provides sufficient capacity for the entire rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of terminal base should I use with this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-IT2I typically installs onto a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1734-TBCJC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Thermocouple Cold Junction Compensation) terminal base. This base contains the necessary thermistor to perform accurate cold-junction compensation at the termination point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle different thermocouple types (J, K, T, etc.)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure the specific thermocouple type via the Studio 5000 Logix Designer software. The module internalizes the linearization curves for all standard thermocouple types, providing temperature data directly in Celsius or Fahrenheit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 1734-IT2I better than the non-isolated 1734-IT2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes, specifically in environments with high EMI or different ground potentials. The \"I\" in 1734-IT2I stands for isolation. While the standard IT2 is sufficient for simple, localized loops, the IT2I prevents a failure or noise on one channel from migrating to the other.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52847184609589,"sku":"1734-IT2I","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-IT2I.png?v=1778219086"},{"product_id":"allen-bradley-1734-ov8s-point-guard-i-o-safety-output-module","title":"Allen-Bradley 1734-OV8S POINT Guard I\/O Safety Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 1734-OV8S operates as a high-density, distributed safety output module within the POINT Guard I\/O hardware architecture. This specialized component executes safety-critical de-energization commands for industrial automation networks, controlling safety contactors, light curtains, emergency stop circuits, and robotic interlocking gates.\u003c\/p\u003e\n\u003cp\u003eThe module interfaces directly with GuardLogix controllers via the standard POINT I\/O backplane to enforce safety configurations up to the highest risk thresholds. We supply this automation component strictly as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new, original factory-sealed unit\u003c\/strong\u003e, which guarantees untouched solid-state switching channels, immaculate internal diagnostic circuitry, and uncompromised factory firmware compliance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the mechanical, environmental, and functional safety parameters of the 1734-OV8S safety module:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance \u0026amp; Functional Safety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1734-OV8S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDistributed Safety Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Channel Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Sinking Safety Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunctional Safety Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSIL 3 (IEC 61508) \/ Category 4 PLe (EN ISO 13849-1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNominal Input Operating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Voltage Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaximum Load Current per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 Amperes per Output (Max)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 Watts per Output Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNative POINT I\/O Backplane System Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHorizontal or Vertical DIN Rail Mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions (H x W x D)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.30 x 3.50 x 2.10 inches (83.8 x 88.9 x 53.3 mm)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Component Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 0.7 lbs (0.32 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAchieves Maximum Space Savings via Ultra-Slim Profile:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes an ultra-compact slice architecture that slots into standard 1734 terminal bases on a DIN rail. This space-saving design allows control engineers to build high-density, localized safety nodes inside crowded field junction boxes, removing the need for oversized sub-panels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates False Trips with Onboard Pulse Testing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe solid-state output drivers perform continuous, sub-millisecond pulse testing on the active channels. This automated diagnostic routine detects external wire short-circuits to 24V DC or ground loops instantly without dropping the actuator load, preventing erratic line shutdowns while preserving full SIL 3 protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSustains Reliable Execution Across Wide Temperature Shifts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe rugged internal hardware architecture manages thermal dissipation efficiently, consuming only 0.25W per active channel. This thermal efficiency keeps the module functional across a broad -20°C to 60°C temperature envelope, stopping thermal drifting errors in unconditioned outdoor control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix this 1734-OV8S safety module on the same DIN rail with standard, non-safety POINT I\/O modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The POINT I\/O backplane allows seamless physical and electrical integration of standard and safety-rated modules on a single assembly row. However, you must pair the 1734-OV8S with an EtherNet\/IP adapter that supports CIP Safety protocols (such as the 1734-AENTR) to route the safety data packets back to the master GuardLogix processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat critical terminal base installation rule prevents damage to the module during replacement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTechnicians must mount the module onto a compatible 1734-TB or 1734-TBS terminal base unit before applying field power. Set the mechanical keyswitch on the terminal base to the proper position assigned for this safety output type before sliding the module into place. This mechanical lock stops technicians from accidentally inserting a standard digital module into a high-voltage safety wiring slot during field maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does a sourcing output differ from the sinking outputs found on the 1734-OV8S?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1734-OV8S utilizes sinking safety outputs (designated by the \"V\" in the part number). When the safety condition enables the output, the module connects the output pin to the 0V DC ground common, pulling the current through the load. Sourcing safety modules (like the 1734-OB8S), by contrast, switch the +24V DC positive leg to drive the field load. Field technicians must match this sinking characteristic with the correct polarity of the connected actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52906250633525,"sku":"1734-OV8S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1734-OV8S.png?v=1779258322"}],"url":"https:\/\/www.5gplc.com\/collections\/allen-bradley-point-i-o.oembed?page=3\u0026type=grid","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}