{"title":"Allen-Bradley MicroLogix","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eAllen-Bradley MicroLogix\u003c\/strong\u003e\u003cspan\u003e is a compact PLC series designed for industrial automation applications. These controllers provide reliable logic control, flexible I\/O connectivity, and seamless integration with HMIs and other Rockwell Automation devices. Widely used in manufacturing, process, and machine automation, MicroLogix PLCs deliver precise automation, scalable system expansion, and long-term operational reliability in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"allen-bradley-1762-l24bwa-micrologix-1200-plc-programmable-controller","title":"Allen-Bradley 1762-L24BWA | MicroLogix 1200 PLC | Programmable Controller","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe Allen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a MicroLogix 1200 series programmable controller designed for compact industrial automation applications. It provides 14 digital inputs and 10 relay outputs, supporting reliable control in a wide range of environments. Built-in power flexibility and robust design ensure stable operation in both standard and challenging conditions.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Electrical\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24BWA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e: 120\/240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Range\u003c\/strong\u003e: 100 to 240V AC (-15% to +10%) at 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 70 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Circuit Type\u003c\/strong\u003e: 24V DC sink\/source\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Circuit Type\u003c\/strong\u003e: Relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Operation Shock Tolerance\u003c\/strong\u003e: 1.5G\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e: 14 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e: 10 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 55°C (+32°F to +131°F) ambient\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5% to 95%, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Tolerance\u003c\/strong\u003e: 10–500 Hz, 5G, 0.030 in peak-to-peak for 2 hours per axis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLength\u003c\/strong\u003e: 11 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 9 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e: 8.7 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.91 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for small-to-medium process control systems, machine automation, and remote I\/O operations where compact size, moderate I\/O counts, and reliable AC power operation are required.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage range does the controller support?\u003c\/strong\u003e\u003cbr\u003eA: It operates from 100 to 240V AC with standard industrial frequency (47–63 Hz).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O points are available?\u003c\/strong\u003e\u003cbr\u003eA: The controller provides 14 digital inputs and 10 relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it operate in high-humidity environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports 5%–95% relative humidity in non-condensing conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it suitable for vibration-prone environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it tolerates up to 5G vibration and 0.03 in peak-to-peak displacement.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52140199248181,"sku":"1762-L24BWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L24BWA.jpg?v=1767693741"},{"product_id":"1761-net-aic-allen-bradley-aic-advanced-interface-converter-dh-485","title":"1761-NET-AIC | Allen-Bradley | AIC+ Advanced Interface Converter DH-485","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-AIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an AIC+ Advanced Interface Converter developed by Allen-Bradley for seamless communication between controllers, operator interfaces, and other DH-485 network devices. It acts as a signal isolation and protocol conversion module, providing reliable and noise-resistant data exchange across industrial networks. The unit supports multiple serial connections and features rugged construction designed to operate in demanding environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-AIC\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAIC+ Advanced Interface Converter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2 × RS-232 ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × DH-485 port (DH-485 protocol supported on all ports)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Function:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables multi-point DH-485 networking between PLCs, PanelView HMIs, and PCs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 V DC for 60 seconds (port-to-port isolation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.4–28.8 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 mA at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 mA maximum @ 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Transmission:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully isolated and optically protected communication channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–500 Hz, 5 g, 0.030 in. peak-to-peak, 2 hours per axis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Shock:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 g, ±3 shocks per axis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Operating Shock:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 g, ±3 shocks per axis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePerformance and Design\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDH-485 on all communication channels for robust multi-device integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-voltage isolation between serial and DH-485 networks enhances noise immunity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN-rail or panel-mounted for flexibility in industrial enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in surge and transient suppression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLED indicators for communication and power status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-AIC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverter is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLinking MicroLogix, SLC 500, and PLC-5 controllers to DH-485 networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting PanelView terminals and programming computers for data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProviding galvanic isolation between PLC serial ports and industrial networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEstablishing communication bridges in distributed automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which Allen-Bradley controllers are compatible with the 1761-NET-AIC?\u003c\/strong\u003e\u003cbr\u003eA1: It is compatible with MicroLogix, SLC 500, and PLC-5 controllers that support DH-485 communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What type of power source is required?\u003c\/strong\u003e\u003cbr\u003eA2: The module operates on 20.4–28.8 V DC, typically supplied from a PLC or external power adapter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it provide electrical isolation?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, the unit is isolated and tested at 500 V DC to prevent cross-port electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How many devices can be networked using this converter?\u003c\/strong\u003e\u003cbr\u003eA4: Up to 32 DH-485 devices can be connected in a single network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52144454959413,"sku":"1761-NET-AIC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-NET-AIC.jpg?v=1767757430"},{"product_id":"allen-bradley-1761-cbl-pm02-micrologix-rs-232-programming-cable","title":"Allen-Bradley 1761-CBL-PM02 MicroLogix RS-232 Programming Cable","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-CBL-PM02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a communication and programming cable manufactured by Allen-Bradley, designed for direct connection between a PC serial port and MicroLogix controllers. It provides a stable RS-232 interface, ensuring reliable data transfer during programming, configuration, and diagnostics. This cable is essential for engineers and technicians working with MicroLogix 1000, 1200, and 1500 PLC systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-CBL-PM02\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-232 communication and programming cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9-pin D-shell female (PC side) to 8-pin mini-DIN (controller side)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.5 meters (approx. 8.2 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Standard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-232 serial interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1000, 1200, and 1500 controllers; some PanelView terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides point-to-point communication between controller and programming terminal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShielded cable design for EMI protection and long-term durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Transfer Rate:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports standard baud rates up to 19.2 kbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo external power required; direct connection via serial port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-25°C to 70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh dielectric strength to prevent signal loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade PVC with high flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Shell:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNickel-plated for corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-CBL-PM02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecable is commonly used for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProgramming and configuring MicroLogix PLCs via RS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUploading and downloading ladder logic programs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting HMIs such as PanelView 300 or 550 to MicroLogix controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerforming real-time diagnostics and maintenance tasks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which controllers are compatible with the 1761-CBL-PM02?\u003c\/strong\u003e\u003cbr\u003eA1: It supports MicroLogix 1000, 1200, and 1500 controllers and select PanelView terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the cable length?\u003c\/strong\u003e\u003cbr\u003eA2: The cable is 2.5 meters (approximately 8.2 feet) long.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this cable be used with a USB port?\u003c\/strong\u003e\u003cbr\u003eA3: Not directly. A USB-to-RS-232 adapter is required for use with modern computers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is the cable shielded for noise reduction?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it includes internal shielding to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52144515744053,"sku":"1761-CBL-PM02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-CBL-PM02_84ad2e1f-3435-4e9f-bf60-39634bc1409d.jpg?v=1767757889"},{"product_id":"1764-24bwa-allen-bradley-micrologix-1500-24-point-ac-dc-base-unit","title":"1764-24BWA | Allen-Bradley | MicroLogix 1500 24-Point AC\/DC Base Unit","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact and durable base unit from the Allen-Bradley MicroLogix 1500 family. It provides an integrated platform for industrial automation systems, combining AC power input, DC I\/O capability, and expandability into a single reliable base. This unit is ideal for process control, discrete manufacturing, and machine-level automation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24BWA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Controller Base Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120\/240 V AC, single phase\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmbedded I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 digital inputs and 12 digital outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC, sink\/source\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125 V DC or 120–240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Port:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-232 serial interface for programming and data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to 512 I\/O points using 1769 Compact I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcessor Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWorks with 1764-LSP and 1764-LRP processors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Modules:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports 1764-MM1\/MM2\/MM3\/MM4 memory modules and 1764-RTC real-time clock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125 V DC or 120–240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e100 VA nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel or DIN rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.43 × 6.62 × 3.43 in (138 × 168 × 87 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.75 kg (1.65 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOpen-style, suitable for protected enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003ePerformance and Design\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates seamlessly into MicroLogix 1500 control systems. It delivers efficient I\/O handling, stable AC\/DC operation, and modular scalability for future system growth. Its isolation design and high electrical durability make it dependable even in vibration-prone or noisy industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for a wide range of automation tasks, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachine control and motion applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and assembly equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilding management and HVAC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM and custom control solutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What processors can be installed with the 1764-24BWA?\u003c\/strong\u003e\u003cbr\u003eA1: It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LRP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LSP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the unit be expanded for additional I\/O?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e512 I\/O points\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen connected with Compact I\/O modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the unit support both AC and DC power?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it operates on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120\/240 V AC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einput and supports DC I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What communication interface does it provide?\u003c\/strong\u003e\u003cbr\u003eA4: It features an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-232 serial port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor programming and data exchange.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52144518267189,"sku":"1764-24AWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-24AWA.jpg?v=1767758246"},{"product_id":"allen-bradley-micrologix-1500-1764-24bwa-controller-base","title":"Allen-Bradley MicroLogix 1500 1764-24BWA Controller Base","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1764-24BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact base unit designed for the MicroLogix 1500 programmable controller platform. It provides integrated AC power, embedded I\/O, and support for modular expansion, making it a flexible foundation for small to mid-sized control systems. The unit offers robust performance for a variety of industrial automation tasks, from machine control to process monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 85–265 V AC input, operating at 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDelivers 88 VA power consumption, optimized for energy-efficient operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned with integrated I\/O capacity for compact control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with MicroLogix 1500 processor modules for scalable performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, DIN-rail or panel mount design ideal for space-constrained installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable operation in ambient temperatures from 0°C to 55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-24BWA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1500 Series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Controller Base Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e85–265 V AC, 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e88 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40°C to +85°C (–40°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.7 × 16.8 × 13.8 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel or DIN-rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20 (when properly installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance and Integration\u003c\/strong\u003e\u003cbr\u003eThe 1764-24BWA base unit forms the core of the MicroLogix 1500 system, providing the power and connectivity needed for a wide range of industrial control applications. It supports modular expansion with additional I\/O, communication adapters, and specialty modules, allowing engineers to tailor the system to specific process requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging and material handling equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and environmental monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial machinery and process automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact distributed control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What processors are compatible with the 1764-24BWA base unit?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports MicroLogix 1500 processor modules such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LSP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LRP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What power supply is integrated into the 1764-24BWA?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt includes a built-in AC power supply rated for 85–265 V AC input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this base unit be expanded?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it allows modular I\/O expansion through compatible MicroLogix modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the recommended installation environment?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA4:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndoor use within an ambient temperature range of 0°C to 55°C and relative humidity under 95%.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52154562314549,"sku":"1764-24BWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-24BWA.jpg?v=1767925542"},{"product_id":"allen-bradley-micrologix-1762-iq32t-32-channel-input-module","title":"Allen-Bradley MicroLogix | 1762-IQ32T 32-Channel Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-point discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix controller series\u003c\/strong\u003e, offering compact, high-density input capability. With four isolated groups of eight channels each, it provides improved electrical isolation and flexibility for a wide range of control applications. Operating at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e, the module supports various MicroLogix controllers, including the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1100, 1200, and 1500\u003c\/strong\u003e, making it an adaptable choice for scalable automation systems. Its small footprint and efficient power usage allow seamless integration in control cabinets where space and performance are critical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IQ32T\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 digital channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Grouping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 isolated groups of 8 channels each\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum ON-State Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.6 mA @ 10 VDC; 2 mA @ 15 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay (ON):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 milliseconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e170 mA @ 5.1 VDC; 0 mA @ 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.4 to 6.8 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1200 VAC for 2 seconds; 1697 VDC for 2 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–26.4 VDC (at 60°C); 10–30 VDC (at 30°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1100, 1200, and 1500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 x 40.4 x 87 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 g (0.44 lb)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5%–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 g, 10–500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density digital input expansion in MicroLogix control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact machinery with limited panel space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory automation requiring fast input response times\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into distributed control systems and small process machines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eComparison with Similar Models\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-IQ16:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16-point input module, smaller I\/O capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-IQ32T:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32-point high-density module with isolation grouping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-OB32T:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32-point transistor output module for DC output control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which MicroLogix controllers are compatible with the 1762-IQ32T?\u003c\/strong\u003e\u003cbr\u003eA: The module supports MicroLogix 1100, 1200, and 1500 controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module handle mixed voltage input signals?\u003c\/strong\u003e\u003cbr\u003eA: No, all inputs operate within a 10–30 VDC range and must maintain consistent voltage levels per group.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is the module mounted?\u003c\/strong\u003e\u003cbr\u003eA: It can be DIN rail-mounted or directly panel-mounted using standard brackets.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52240176382261,"sku":"1762-IQ32T","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IQ32T.jpg?v=1768893692"},{"product_id":"allen-bradley-1762-if4-micrologix-4-channel-analog-input-module","title":"Allen-Bradley | 1762-IF4 MicroLogix 4-Channel Analog Input Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IF4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 4-channel analog input module designed for the MicroLogix series PLCs. It provides reliable voltage and current signal conversion for precise analog data acquisition. The module supports both bipolar voltage and current ranges, ensuring accurate measurements for industrial control and monitoring applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 4-Point Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVoltage or Current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range (Normal):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10 to +10 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range (Full Scale):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-10.5 to +10.5 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Range (Normal):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Range (Full Scale):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-21 to +21 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 bits (bipolar)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.12%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30V AC \/ 30V DC (reinforced, IEC Class 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType Test:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500V AC or 707V DC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Draw (Max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 mA @ 5V DC, 50 mA @ 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Power LED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates active power status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Cable:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBelden 8761 (shielded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 × 40.4 × 87 mm (3.54 × 1.59 × 3.43 in.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e235 g (8.28 oz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eT3C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePilot Duty Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNot rated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Category:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 – signal ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFactory Warranty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 months\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15-bit bipolar resolution enables accurate analog data representation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Signal Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both voltage and current input types for flexible integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReinforced insulation between input group and system for safety and reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eError Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOver- and under-range flags ensure system diagnostics for abnormal input conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpace-saving module ideal for dense control panel installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control and signal monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial data acquisition systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnergy management and automation panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature or pressure transmitter input measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the resolution of the 1762-IF4 module?\u003c\/strong\u003e\u003cbr\u003eA1: The module provides a 15-bit bipolar resolution for precise signal conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What type of signals can it process?\u003c\/strong\u003e\u003cbr\u003eA2: It accepts both voltage (-10 to +10 VDC) and current (4 to 20 mA) inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the module have input isolation?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it provides 30V AC \/ 30V DC reinforced isolation between the input and system circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What cable type is recommended for installation?\u003c\/strong\u003e\u003cbr\u003eA4: Belden 8761 shielded cable is recommended for optimal signal integrity.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244424196405,"sku":"1762-IF4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IF4.jpg?v=1768979203"},{"product_id":"1762-ir4-allen-bradley-micrologix-1200-resistance-input-module","title":"1762-IR4 | Allen-Bradley MicroLogix 1200 Resistance Input Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IR4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a MicroLogix 1200 series RTD and resistance input module designed to measure temperature and resistance signals with high precision. It supports a variety of RTD sensors and resistive elements, offering reliable performance across a wide range of industrial environments. This module is engineered for accurate temperature monitoring and process control applications that demand stability and repeatability.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IR4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1200 RTD\/Resistance Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (H × W × D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 × 40 × 87 mm (3.54 × 1.58 × 3.43 in.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight with Mounting Tabs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110 mm (4.33 in.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApproximate Shipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e260 g (0.57 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40°C to +85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 2000 m (6561 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–500 Hz, 5G, 0.030 in. peak-to-peak\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30G operating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Draw (Max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 mA @ 5V DC, 50 mA @ 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30V AC\/30V DC (reinforced insulation, IEC Class 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType Test:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500V AC or 707V DC for 1 minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower LED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndicates module power status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Location Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass I, Division 2, Groups A, B, C, D (ISA\/ANSI 12.12.01, C-UL CSA C22.2 No. 213)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVendor ID Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e65\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type Code:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental and EMC Compliance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRadiated \u0026amp; Conducted Emissions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEN50081-2 Class A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eESD Immunity (EN61000-4-2):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 kV contact, 8 kV air, 4 kV indirect\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRadiated Immunity (EN61000-4-3):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 V\/m, 80–1000 MHz, 80% AM, keyed carrier +900 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Transient Burst (EN61000-4-4):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV, 5 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Immunity (EN61000-4-5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConducted Immunity (EN61000-4-6):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 V, 0.15–80 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Accuracy Measurement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for precise RTD and resistive input conversion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates reliably in both low and high ambient conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified for hazardous locations with reinforced electrical insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Signal Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithstands vibration, shock, and electrical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly fits within MicroLogix 1200 systems for temperature or resistance monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IR4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess temperature monitoring and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial furnace and kiln systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and energy management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and utility control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What type of sensors does the 1762-IR4 support?\u003c\/strong\u003e\u003cbr\u003eA1: It supports a variety of RTD sensors and resistance measurement inputs within MicroLogix 1200 systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is this module rated for hazardous areas?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it is rated for Class I, Division 2 hazardous locations (Groups A, B, C, and D).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the module have electrical isolation?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it provides reinforced insulation rated at 30V AC\/30V DC for safe and reliable operation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244461289781,"sku":"1762-IR4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IR4.jpg?v=1768979462"},{"product_id":"allen-bradley-1762-if2of2-micrologix-4-channel-analog-i-o-module","title":"Allen-Bradley 1762-IF2OF2 MicroLogix 4-Channel Analog I\/O Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact analog input\/output module designed for the MicroLogix™ controller family. It provides two differential analog inputs and two single-ended analog outputs, making it suitable for precise analog signal processing and control in industrial automation systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix Analog Input\/Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 differential (unipolar)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eA\/D Converter Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuccessive approximation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Input Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVoltage 0–10 V DC, Current 4–20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Mode Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±27 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection Ratio (CMRR):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt;55 dB at 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 single-ended (unipolar)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eD\/A Converter Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eResistor string\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistive Load on Current Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–500 Ω (including wire resistance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Draw (Max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 mA @ 5V DC, 105 mA @ 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (L × W × H):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.7 × 4.04 × 9 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.24 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVia MicroLogix backplane bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail or panel-mounted\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel-to-system reinforced insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual I\/O Functionality:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombines both analog input and output in one module for space-efficient system design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Conversion Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuccessive approximation A\/D converter ensures precise analog-to-digital conversion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Signal Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles both voltage and current inputs\/outputs for various control requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt;55 dB CMRR minimizes electrical interference in signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and Rugged Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for industrial panels with limited space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog signal scaling and conditioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature, pressure, and flow transmitter inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent and voltage control for actuators or drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many analog channels does the 1762-IF2OF2 provide?\u003c\/strong\u003e\u003cbr\u003eA1: It provides two differential analog inputs and two single-ended analog outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the supported signal range?\u003c\/strong\u003e\u003cbr\u003eA2: It accepts voltage signals from 0–10 V DC and current signals from 4–20 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the module include electrical isolation?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it provides reinforced isolation between I\/O channels and the system backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the typical load resistance for current output channels?\u003c\/strong\u003e\u003cbr\u003eA4: The output can drive a resistive load of up to 500 Ω, including wire resistance.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244489601333,"sku":"1762-IF2OF2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IF2OF2.jpg?v=1768979843"},{"product_id":"allen-bradley-1762-ow16-micrologix-1200-relay-output-module","title":"Allen-Bradley 1762-OW16 MicroLogix 1200 Relay Output Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-OW16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance relay output module for MicroLogix 1200 series controllers. It provides sixteen isolated AC\/DC relay outputs grouped into two independent banks, enabling flexible control of industrial loads. Designed for DIN rail mounting, this module ensures reliable switching performance with minimal signal delay.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW16\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1100 \/ 1200 \/ 1400\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN Rail\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Groups:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 AC\/DC relay channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Contact Voltage Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125 VDC; 120–240 VAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–265 V AC; 5–125 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannels per Group:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current per Point:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.5 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6.1 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.69 lbs (0.31 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTwo isolated relay groups for independent load control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail mounting for easy integration into MicroLogix systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports AC and DC loads across a wide voltage range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast response time of 10 ms for precise switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust design with 2.5 A per channel capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching AC or DC actuators in MicroLogix-controlled automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControlling small motors, solenoids, or indicator circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for applications requiring multiple independent relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for factory automation, process control, or general industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many isolated relay groups does the 1762-OW16 provide?\u003c\/strong\u003e\u003cbr\u003eA1: The module has two independent isolated groups with 8 channels each.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum current rating per relay output?\u003c\/strong\u003e\u003cbr\u003eA2: Each relay channel supports up to 2.5 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which controllers is this module compatible with?\u003c\/strong\u003e\u003cbr\u003eA3: It works with MicroLogix 1100, 1200, and 1400 series controllers.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244602224949,"sku":"1762-OW16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-OW16.jpg?v=1768981817"},{"product_id":"1762-iq16-allen-bradley-micrologix-16-point-digital-input-module","title":"1762-IQ16 | Allen-Bradley MicroLogix 16 Point Digital Input Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a reliable 16-channel digital input module for the MicroLogix 1200 series, supporting both sink and source 24V DC signals. Designed for precise industrial control, it features low signal delay and stable operation over a wide voltage range. Compact and DIN rail-compatible, this module integrates seamlessly with MicroLogix controllers.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IQ16\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDC Digital Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Category:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (sink\/source)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–30V DC nominal; 10–26.4V DC typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Draw (max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e70 mA @ 5V DC (0.35 W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.4 W @ 30V DC; 4.3 W @ 26.4V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay (max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOn: 8 ms; Off: 8 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOff-State Voltage (max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOff-State Current (max):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Voltage (min):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 mA min @ 10V DC, 8 mA nom @ 24V DC, 12 mA max @ 30V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Category:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 – signal ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (LxWxH):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.7 × 4.1 × 9 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16 digital input channels with selectable sink\/source configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast 8 ms response time for both on and off signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide operating voltage range suitable for various DC control signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design compatible with MicroLogix 1200 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow power consumption and efficient heat management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDigital signal monitoring and acquisition in MicroLogix-controlled systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnecting pushbuttons, switches, and low-voltage sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomation projects requiring multiple digital inputs in a small footprint\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for factory, process, or discrete control environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many digital inputs does the 1762-IQ16 provide?\u003c\/strong\u003e\u003cbr\u003eA1: The module has 16 digital input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the typical signal delay for this module?\u003c\/strong\u003e\u003cbr\u003eA2: Maximum on\/off signal delay is 8 milliseconds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this module handle both sinking and sourcing inputs?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it supports 24V DC sink\/source configuration.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244619690293,"sku":"1762-IQ16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IQ161.jpg?v=1768982062"},{"product_id":"micrologix-1200-1762-ob16-digital-output-module-allen-bradley","title":"MicroLogix 1200 1762-OB16 Digital Output Module | Allen-Bradley","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-OB16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 16-channel digital output module designed for the MicroLogix 1200 series. It delivers reliable 24V DC switching with isolated output groups for safe and flexible control. Its compact DIN rail-compatible design and rugged construction make it suitable for harsh industrial environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB16\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Category:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.4–26.4V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Groups:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle group (Outputs 0–15)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (LxWxH):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8.7 × 4 × 9 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–55°C (32–131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Operating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40–85°C (-40–185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUp to 2000 m (6561 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration (Operating):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–500 Hz, 5 g, 0.030 in peak-to-peak, 2 hours per axis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock (Operating):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30 g panel-mounted, 3 pulses per axis; Non-operating: 50 g panel-mounted, 3 pulses per axis (40 g DIN rail mounted)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16-point digital outputs for MicroLogix controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle isolated output group ensures safe signal separation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact form factor for easy DIN rail installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide operating temperature and humidity tolerance for industrial use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust construction resistant to vibration and shock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDriving relays, solenoids, and small AC\/DC loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete control in MicroLogix-based automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory or process automation where multiple outputs are needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into small footprint panels or cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many outputs does the 1762-OB16 provide?\u003c\/strong\u003e\u003cbr\u003eA1: The module has 16 digital outputs in a single isolated group.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the operating voltage range?\u003c\/strong\u003e\u003cbr\u003eA2: The outputs operate between 20.4 and 26.4V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this module suitable for harsh environments?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, it supports wide temperature ranges, high humidity, vibration, and shock.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244635615541,"sku":"1762-OB16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-OB16.jpg?v=1768982313"},{"product_id":"allen-bradley-1762-ob8-ser-a-micrologix-8-point-digital-output-module","title":"Allen-Bradley 1762-OB8 Ser A MicroLogix 8-Point Digital Output Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-OB8 Ser A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8-channel digital output module for the MicroLogix series. It provides reliable DC output control with robust protection against environmental stresses and electrical noise. Designed for use in hazardous and standard industrial locations, this compact module ensures precise and safe signal switching.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB8\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix Digital Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Height x Width x Depth:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 × 40 × 87 mm (overall height including mounting tabs: 110 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e210 g (0.46 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–55°C (32–131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40–85°C (-40–185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Operating Altitude:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2000 m (6561 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Environment Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass I, Division 2, Groups A-D; compliant with ISA\/ANSI 12.12.01 and C-UL under CSA C22.2 No. 213\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Noise Immunity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMeets NEMA ICS 2-230, EN50081-2 Class A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eESD Immunity (EN61000-4-2):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 kV contact, 8 kV air, 4 kV indirect\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRadiated Immunity (EN61000-4-3):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 V\/m, 80–1000 MHz, 80% amplitude modulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast Transient Burst (EN61000-4-4):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV, 5 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Immunity (EN61000-4-5):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 kV common mode, 1 kV differential mode\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConducted Immunity (EN61000-4-6):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 V, 0.15–80 MHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 isolated digital outputs for MicroLogix series controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact form factor with mounting tabs for easy installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistant to vibration, shock, and extreme temperatures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConforms to hazardous location safety standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in immunity against ESD, surges, fast transients, and radiated noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSmall to medium discrete control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching DC loads such as relays, solenoids, and indicator devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDeployment in both standard and hazardous industrial zones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with MicroLogix controllers in control panels or cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many outputs does the 1762-OB8 Ser A provide?\u003c\/strong\u003e\u003cbr\u003eA1: The module provides 8 isolated digital outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can it operate in hazardous locations?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it is certified for Class I, Division 2 environments, Groups A–D.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What protection does it have against electrical noise?\u003c\/strong\u003e\u003cbr\u003eA3: It meets NEMA ICS 2-230, EN50081-2 Class A, and IEC 61000 series for ESD, surge, fast transient, and radiated immunity.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244654063925,"sku":"1762-OB8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-OB8.jpg?v=1768982601"},{"product_id":"allen-bradley-1762-iq8ow6-micrologix-1200-8-input-6-output-module","title":"Allen-Bradley 1762-IQ8OW6 MicroLogix 1200 8-Input 6-Output Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ8OW6\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile combination I\/O module designed for the MicroLogix 1200 series. It integrates 8 DC input channels and 6 relay output channels into a single compact module, providing flexible control for small to medium-sized automation systems. The module supports both sink and source inputs, and outputs are rated for AC and DC loads with normally open contacts.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IQ8OW6\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix Combination I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8-input \/ 6-output integrated module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 DC inputs, sink\/source compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Groups:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 groups with 4 channels per group\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–30 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6 relay outputs, normally open (N.O.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–265 V AC, 5–125 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Contact Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2.5 A for 120\/240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2.0 A for 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1.0 A for 125 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.44 lbs (0.20 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated combination module reduces cabinet space\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e8 DC inputs divided into 2 isolated groups for flexible wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e6 relay outputs capable of switching AC or DC loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and lightweight for easy installation in MicroLogix 1200 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both sink and source input logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable performance across standard industrial temperature and voltage ranges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSmall-scale discrete automation and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitching relays, solenoids, and indicator lights\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration in MicroLogix 1200-based control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for applications requiring both input monitoring and output control in one module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many outputs does the 1762-IQ8OW6 provide?\u003c\/strong\u003e\u003cbr\u003eA1: The module provides 6 relay outputs, all normally open.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module handle both AC and DC loads?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, outputs are rated for AC (5–265 V) and DC (5–125 V) loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the input voltage range for the DC inputs?\u003c\/strong\u003e\u003cbr\u003eA3: Inputs operate reliably from 10 to 30 VDC.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244682637621,"sku":"1762-IQ8OW6","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IQ8OW6.jpg?v=1768982798"},{"product_id":"allen-bradley-micrologix-1200-1762-l24awa-24vdc-plc-controller","title":"Allen-Bradley MicroLogix 1200 1762-L24AWA 24VDC PLC Controller","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-L24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance MicroLogix 1200 programmable logic controller designed for small- to medium-scale automation systems. It features mixed AC inputs and relay outputs, offering reliable control with versatile communication options. Its compact design and DIN-rail compatibility allow easy integration in various industrial setups.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24AWA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Logic Controller (PLC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.25 lbs (0.57 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120–240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e14 AC inputs (120V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Relay Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125 V DC; 120–240 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Circuit Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Circuit Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Life Cycles:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 million\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimum 10 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 × 8-pin mini-DIN serial port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDF1, DH-485, ASCII, MODBUS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 mA per input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Inrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e250 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Usage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e68 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Inrush:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25 A @ 8 ms (120V AC), 40 A @ 4 ms (240V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCombines 14 AC inputs with 10 relay outputs for versatile control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh mechanical cycle life ensures long-term reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multiple serial communication protocols including DF1 and MODBUS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design with DIN-rail mounting for flexible installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC power supply allows stable operation across varied industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for small- to medium-scale automation applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eControl of manufacturing lines with mixed AC sensor and relay actuator setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into distributed MicroLogix 1200 networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess automation where compact footprint and reliable I\/O is critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOEM machine control with standard AC inputs and relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many input and output points does this PLC support?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 14 AC inputs and 10 relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003eA2: DF1, DH-485, ASCII, and MODBUS protocols are available for serial communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum operating temperature?\u003c\/strong\u003e\u003cbr\u003eA3: This PLC operates reliably from 0°C to 55°C.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244761772341,"sku":"1762-L24AWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L24AWA.jpg?v=1768984011"},{"product_id":"allen-bradley-micrologix-1200-1762-l24bxb-24vdc-programmable-controller","title":"Allen-Bradley MicroLogix 1200 1762-L24BXB 24VDC Programmable Controller","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-L24BXB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile MicroLogix 1200 programmable logic controller (PLC) designed for industrial control applications requiring a combination of standard and high-speed inputs and multiple output types. It supports mixed relay and FET outputs, providing flexible control for small- to medium-scale automation systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24BXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1200 Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 standard 24V DC + 4 high-speed 24V DC inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5 relay outputs, 4 standard 24V DC FET outputs, 1 high-speed 24V DC FET output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (L × W × H):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e34 cm × 19 cm × 16 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.9 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN Rail compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports standard MicroLogix 1200 serial communication protocols (DF1, DH-485, MODBUS)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–55°C (32–131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–40–85°C (–40–185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCombines standard and high-speed DC inputs for flexible signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMixed output configuration with relay and FET channels for diverse load control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact DIN-rail design allows easy integration into control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports reliable 24 VDC operation for industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for machine-level control, process automation, and OEM applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated production lines with mixed-speed sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with MicroLogix 1200 networks for distributed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl of multiple actuators and relays in machine and process systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for small-to-medium PLC applications requiring both speed and flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many high-speed inputs does this controller provide?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L24BXB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes 4 high-speed 24V DC inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What types of outputs are available?\u003c\/strong\u003e\u003cbr\u003eA2: It features 5 relay outputs, 4 standard 24V DC FET outputs, and 1 high-speed 24V DC FET output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the operating power requirement?\u003c\/strong\u003e\u003cbr\u003eA3: This PLC operates on a 24 VDC power supply.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244787265845,"sku":"1762-L24BXB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L24BXB2__1.jpg?v=1768984521"},{"product_id":"1766-l32bwa-allen-bradley-micrologix-1400-plc-120-240v-ac","title":"1766-L32BWA | Allen-Bradley MicroLogix 1400 PLC 120\/240V AC","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1766-L32BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a MicroLogix 1400 programmable logic controller designed for medium-scale automation applications. It integrates fast and standard digital inputs with multiple relay outputs and flexible communication options, making it ideal for process and machine control.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32BWA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1400 Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eController I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 fast 24V DC digital inputs, 8 standard 24V DC digital inputs, 12 relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110\/240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of I\/O Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 inputs, 12 outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmbedded Analog:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 KB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet, isolated RS-232\/485, non-isolated RS-232C serial\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Dimensions (H x D):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 mm × 87 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDF1, DH-485, MODBUS RTU, MODBUS TCP\/IP, ASCII, DNP3, EtherNet\/IP messaging, DNP3 over IP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel or DIN-Rail compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCombines high-speed and standard digital inputs for flexible process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwelve relay outputs allow versatile load management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple communication protocols for seamless integration in mixed PLC networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-voltage AC operation for international compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact, durable design suitable for harsh industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eControl of mid-sized machinery with mixed-speed sensor inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into distributed MicroLogix 1400 networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomation of process lines requiring both high-speed and standard inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for OEM applications and panel-mounted control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many fast digital inputs does this PLC provide?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32BWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 12 fast 24V DC inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What output types are included?\u003c\/strong\u003e\u003cbr\u003eA2: The controller provides 12 relay outputs for controlling loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Which communication interfaces are supported?\u003c\/strong\u003e\u003cbr\u003eA3: Ethernet, isolated RS-232\/485, and non-isolated RS-232C serial ports, supporting DF1, DH-485, Modbus RTU, ASCII, DNP3, Modbus TCP\/IP, and EtherNet\/IP messaging.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244811972917,"sku":"1766-L32BWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1766-L32BWA.jpg?v=1768984735"},{"product_id":"allen-bradley-micrologix-1400-1766-l32bwaa-programmable-controller","title":"Allen-Bradley MicroLogix 1400 1766-L32BWAA Programmable Controller","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1766-L32BWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance MicroLogix 1400 programmable controller engineered for flexible automation tasks. It integrates fast and standard digital inputs alongside analog channels and multiple relay outputs, providing a total of 38 I\/O points. Designed for both panel and DIN-rail mounting, this controller supports a wide range of industrial communication protocols, making it ideal for mid-scale process control applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32BWAA\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1400 Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1400\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Points:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e38 total (20 inputs, 12 outputs, 6 analog points)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 fast 24V DC, 8 standard 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 channels, 0–10V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 single-ended channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110–240V AC, 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Inrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120V AC: 25A for 8 ms; 240V AC: 40A for 4 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 KB non-volatile\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet, isolated RS-232\/485, non-isolated RS-232\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmbedded Features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in real-time clock (RTC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePanel or DIN-rail compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard industrial conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCombines fast and normal digital inputs for versatile control scenarios\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated analog inputs and outputs support mixed-signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple relay outputs for managing diverse load types\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in RTC for time-stamped operations and logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports DF1, DH-485, MODBUS RTU\/TCP, ASCII, DNP3, and EtherNet\/IP messaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial process control requiring both digital and analog I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into MicroLogix 1400 networks with mixed input\/output requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMachine automation with fast and standard sensor inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePanel-mounted or DIN-rail installations for OEM systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many digital inputs are fast vs standard?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32BWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides 12 fast 24V DC inputs and 8 standard 24V DC inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What communication protocols are supported?\u003c\/strong\u003e\u003cbr\u003eA2: Ethernet, RS-232\/485, and RS-232 ports support DF1, DH-485, MODBUS RTU\/TCP, ASCII, DNP3, and EtherNet\/IP messaging.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How many analog outputs are available?\u003c\/strong\u003e\u003cbr\u003eA3: Two single-ended analog output channels are included for voltage control.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52244827799861,"sku":"1766-L32AWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1766-L32AWA.jpg?v=1768984961"},{"product_id":"allen-bradley-micrologix-1500-1764-lrp-programmable-logic-controller","title":"Allen-Bradley MicroLogix 1500 1764-LRP Programmable Logic Controller","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LRP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an Allen-Bradley MicroLogix 1500 series programmable logic controller, engineered for small to mid-scale automation applications. This module delivers reliable input\/output handling, flexible power options, and stable operation in industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LRP\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1500 Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 digital inputs, 24V DC, sink\/source\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLine Power Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e85–265V AC, 47–63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e88 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Inrush:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e25 A for 8 ms at 120V AC; 40 A for 4 ms at 240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser Power Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC at 400 mA, 400 µF max\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTypical CPU Hold-up Time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–3000 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.9 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware Release:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 kg (1.1 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LRP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for industrial control tasks requiring compact PLCs with moderate I\/O counts. Typical applications include machine control, monitoring of discrete processes, and small-scale automation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat type of inputs does the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-LRP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt supports 12 digital 24V DC inputs, configured for sink or source operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhat is the maximum user power output?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe controller provides 24V DC at 400 mA, suitable for powering low-voltage I\/O devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCan it operate across a wide AC voltage range?\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, it accepts 85–265V AC at 47–63 Hz, accommodating various industrial power sources.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52246067904821,"sku":"1764-LRP","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-LRP1.jpg?v=1769043091"},{"product_id":"allen-bradley-1762-ow8-micrologix-relay-output-module","title":"Allen-Bradley 1762-OW8 MicroLogix Relay Output Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-OW8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8-point relay output module designed for MicroLogix PLC systems. It delivers flexible AC and DC voltage handling and robust contact configuration, making it suitable for a wide range of control panel applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW8\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.30 lbs (0.14 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–265 VAC \/ 5–125 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Relay Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eContact Configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNormally Open (NO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Style\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN Rail Mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Style\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScrew Clamp Terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both AC and DC output signals for versatile control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact DIN rail mount design for panel integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNormally open relay contacts suitable for switching loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScrew clamp terminals provide secure connections for wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with MicroLogix series PLCs for modular expansions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suitable for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePLC-controlled machinery output control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal switching in small to medium-size control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or expansion of existing MicroLogix relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications requiring reliable AC\/DC relay switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eSimilar Models Comparison\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-OW8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 8 relay outputs, AC\/DC voltage support, MicroLogix compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-OW4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 4 relay outputs, smaller footprint, same voltage range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-OB8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 8 transistor outputs, DC only, high-speed switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it handle both AC and DC loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the module supports 5–265 VAC and 5–125 VDC output ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of contacts does it provide?\u003c\/strong\u003e\u003cbr\u003eA: All outputs are normally open (NO) relay contacts suitable for standard switching.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is it mounted in the control panel?\u003c\/strong\u003e\u003cbr\u003eA: The module uses a standard DIN rail mount for easy installation and replacement.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52255516492085,"sku":"1762-OW8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-OW8.jpg?v=1769134196"},{"product_id":"allen-bradley-1762-iq8-micrologix-1200-dc-input-module","title":"Allen-Bradley | 1762-IQ8 MicroLogix 1200 DC Input Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-IQ8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8-channel discrete DC input module for MicroLogix 1200 systems. Designed for precise sensing and reliable signal acquisition, it accommodates both sink and source inputs and provides isolation for secure operation in industrial applications.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IQ8\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDC Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.38 lbs (0.17 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 channels (sink and source)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Groups\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 isolated group with 8 channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eON-State Current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMinimum 2 mA at 10 V DC; Typical 8 mA at 24 V DC; Maximum 12 mA at 30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOFF-State Current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaximum 1.5 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay (ON Transition)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 mA at 5.1 V DC, 0 mA at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1200 V AC for 1 sec or 1697 V DC for 1 sec; 75 V DC working voltage (IEC Class 2 reinforced insulation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.7 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8-channel discrete DC inputs compatible with MicroLogix 1200 series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both sink and source configurations for flexible wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation between channels ensures safe operation and signal integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast 8 ms ON transition suitable for control systems requiring rapid response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact module with low heat dissipation for efficient panel integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IQ8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDC signal acquisition in compact PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExpanding MicroLogix 1200 input capacity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete sensing in OEM machinery and industrial equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplications where channel isolation and precise input detection are required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eSimilar Models Comparison\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-IQ8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 8 discrete DC inputs, isolated, sink\/source compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-IQ16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 16 DC inputs, similar isolation and specifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1762-IR4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– 4-channel isolated relay input module, slower response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage range does this module accept?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IQ8\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports 10–30 V DC input voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is channel isolation provided?\u003c\/strong\u003e\u003cbr\u003eA: Yes, all 8 channels are in a single isolated group with reinforced insulation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How fast is the input response?\u003c\/strong\u003e\u003cbr\u003eA: The ON transition delay is 8 ms, suitable for most PLC applications.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52255531499829,"sku":"1762-IQ8","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IQ8.jpg?v=1769134516"},{"product_id":"allen-bradley-micrologix-1500-1764-28bxb-controller-base-unit","title":"Allen-Bradley MicroLogix 1500 1764-28BXB Controller Base Unit","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1764-28BXB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix 1500 programmable controller base unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for compact industrial control applications. It integrates DC input channels, relay and DC FET outputs, and provides a reliable RS-232 interface for programming and monitoring. Ideal for small to medium automation projects.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-28BXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Controller Base Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHeight 138 mm, Depth 87 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-232C port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 DC inputs, 12 outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6 relay outputs, 6 DC FET outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(6) Relay, (6) 24V DC FET\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120\/240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eController base unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact controller base for MicroLogix 1500 series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both relay and DC FET outputs for flexible device control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated RS-232 port enables easy programming and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e16 DC inputs and 12 outputs for versatile signal handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-voltage AC power supply compatible (120\/240V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSmall-scale process automation requiring precise input\/output management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory or lab setups needing reliable DC input monitoring and mixed output control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReplacement or upgrade for legacy MicroLogix 1500 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many inputs and outputs does the 1764-28BXB support?\u003c\/strong\u003e\u003cbr\u003eA: It provides 16 DC inputs and 12 outputs (6 relay, 6 DC FET).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the communication interface?\u003c\/strong\u003e\u003cbr\u003eA: The unit features an RS-232C port for programming and monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which power supply is compatible?\u003c\/strong\u003e\u003cbr\u003eA: 120–240V AC power supply.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52256093798709,"sku":"1764-28BXB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-28BXB1__1.jpg?v=1769148269"},{"product_id":"1764-dat-allen-bradley-micrologix-1500-data-access-tool-module","title":"1764-DAT | Allen-Bradley | MicroLogix 1500 Data Access Tool Module","description":"\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1764-DAT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a data access tool designed for the MicroLogix 1500 series, providing direct access to memory and controller faults. It allows operators and engineers to monitor, configure, and troubleshoot MicroLogix 1500 CPUs efficiently. The module supports 512 expanded I\/O points and works with 1764-LSP and 1764-LRP controllers. Its compact design draws power directly from the MicroLogix bus, ensuring simple integration without additional power sources.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports direct access to 48-bit elements and 48 integer elements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisplays controller faults for fast diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with MicroLogix 1500 CPUs (1764-LSP, 1764-LRP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonochrome display with integrated navigation and function keys (F1, F2, Escape, Enter, Up\/Down)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemoval under power supported\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperates within 0–55°C with low heat dissipation (1.75 W)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBus current draw: 350 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscontinued product; suitable for legacy systems and spare parts replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-DAT\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eData Access Tool\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Expanded I\/O Count:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e512\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported CPUs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1764-LSP, 1764-LRP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix bus-powered\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Source:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRelay port and DC FET\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDisplay:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonochrome LCD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Buttons:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eF1, F2, Escape, Enter, Up\/Down\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.75 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e350 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLifecycle Status:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscontinued \/ Obsolete\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-DAT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etool is ideal for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring and troubleshooting MicroLogix 1500 controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick diagnostics of I\/O modules and system faults\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect memory access for testing and programming\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration as a diagnostic interface in control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which MicroLogix CPUs are compatible with this module?\u003c\/strong\u003e\u003cbr\u003eA: It supports 1764-LSP and 1764-LRP CPUs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be removed while the system is powered?\u003c\/strong\u003e\u003cbr\u003eA: Yes, removal under power is supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How much memory or I\/O can it access?\u003c\/strong\u003e\u003cbr\u003eA: It allows access to 512 expanded I\/O points and up to 48-bit\/integer elements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this product still actively manufactured?\u003c\/strong\u003e\u003cbr\u003eA: No, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-DAT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis discontinued, but repair and replacement guidance is available.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52270333198645,"sku":"1764-DAT","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-DAT.jpg?v=1769568092"},{"product_id":"1762-of4-allen-bradley-micrologix-1200-4-channel-analog-output-module","title":"1762-OF4 | Allen Bradley MicroLogix 1200 4-Channel Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Allen Bradley MicroLogix 1200 \u003c\/span\u003e\u003cstrong\u003e1762-OF4\u003c\/strong\u003e\u003cspan\u003e provides four single-ended analog outputs with 12-bit resolution, supporting 0–10 VDC and 4–20 mA ranges for precise signal control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e MicroLogix 1200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number \/ Model:\u003c\/strong\u003e \u003cstrong\u003e1762-OF4\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Output Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.00 lbs (0.45 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e 4 analog, single-ended\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNormal Operating Range:\u003c\/strong\u003e 0–10 VDC, 4–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFull Scale Ranges:\u003c\/strong\u003e 0–10.5 VDC, 0–21 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter Type:\u003c\/strong\u003e R-2R ladder voltage switching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit (unipolar)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±1.17% full scale from -20 °C to 65 °C; ±0.5% full scale at 25 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e ±0.12%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 2.8 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRecommended Cable:\u003c\/strong\u003e Belden 8761 (shielded)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcess control systems requiring precise analog signal generation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial automation tasks needing multiple current or voltage outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact PLC installations with limited space but high accuracy requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many analog outputs does the 1762-OF4 provide?\u003c\/strong\u003e  A: Four single-ended analog outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What signal ranges are supported?\u003c\/strong\u003e  A: 0–10 VDC and 4–20 mA, with extended ranges up to 10.5 VDC and 21 mA.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What resolution does the module offer?\u003c\/strong\u003e  A: 12-bit resolution for accurate signal conversion.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparison with Similar Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1762-OF4:\u003c\/strong\u003e 4 analog outputs, voltage\/current supported.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1762-IF4:\u003c\/strong\u003e 4 analog inputs for monitoring signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1762-OF2:\u003c\/strong\u003e 2 analog outputs, smaller footprint.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52288695370037,"sku":"1762-OF4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-OF4.jpg?v=1770016453"},{"product_id":"1764-lsp-allen-bradley-micrologix-1500-processor-controller-module","title":"1764-LSP | Allen Bradley MicroLogix 1500 | Processor Controller Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe Allen Bradley MicroLogix 1500 \u003cstrong\u003e1764-LSP\u003c\/strong\u003e is a discontinued processor unit designed for modular PLC systems. It provides flexible communication options, built-in memory expansion, and support for multiple base units, making it suitable for mid-range automation tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e MicroLogix 1500\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCatalog Number \/ Model:\u003c\/strong\u003e \u003cstrong\u003e1764-LSP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e MicroLogix Controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.44 lbs (0.20 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Processor Unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBase Unit Compatibility:\u003c\/strong\u003e 1764-AWA, 1764-BWA, 1764-BXB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e 7.6 KB base; expandable with memory modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory:\u003c\/strong\u003e Series B: 12K (8K Program, 4K Data); Series C: 14K (10K Program, 4K Data)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e RS232, DH-485, Modbus, DF1, ASCII\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e Channel 0 supports DF1, DH-485, Modbus, ASCII\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRS232 Topology:\u003c\/strong\u003e Point-to-point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Memory Modules:\u003c\/strong\u003e 1764-MM1, 1764-MM2, 1764-MM3\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompatible Real-Time Clock:\u003c\/strong\u003e 1764-RTC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDigital Trim Potentiometers:\u003c\/strong\u003e 2 built-in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eExpansion I\/O Capacity:\u003c\/strong\u003e Up to 512 points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e MicroLogix bus powered\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Sources:\u003c\/strong\u003e Relay port and DC FET\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBus Current Draw:\u003c\/strong\u003e 380 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 1.9 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e IP20\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupport for Removal Under Power:\u003c\/strong\u003e 28 operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status:\u003c\/strong\u003e Discontinued \/ Obsolete\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModular PLC systems requiring flexible communication protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMid-range machine control with expandable I\/O capacity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy automation systems using MicroLogix 1500 architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What memory expansion options are available?\u003c\/strong\u003e  A: Compatible with 1764-MM1, 1764-MM2, and 1764-MM3 modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Which communication protocols are supported?\u003c\/strong\u003e  A: DF1, DH-485, Modbus, and ASCII.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many I\/O points can be expanded?\u003c\/strong\u003e  A: Up to 512 I\/O points.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eComparison with Similar Models\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1764-LSP:\u003c\/strong\u003e Standard processor, 12K–14K user memory, multiple communication protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1764-LRP:\u003c\/strong\u003e Enhanced processor with larger memory and advanced communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1764-MM2:\u003c\/strong\u003e Memory expansion module for program and data storage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52288714473781,"sku":"1764-LSP","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-LSP.jpg?v=1770017494"},{"product_id":"allen-bradley-micrologix-1200-1762-l40bwa-programmable-controller","title":"Allen Bradley MicroLogix 1200 | 1762-L40BWA | Programmable Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1762-L40BWA\u003c\/strong\u003e is a MicroLogix 1200 programmable controller designed for small to mid-sized automation systems. It integrates a built-in power supply, multiple DC inputs, and relay outputs, offering flexibility for diverse control applications. With robust electrical ratings and high mechanical endurance, this controller ensures reliable operation in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e MicroLogix 1200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e PLCs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.06 lbs (0.94 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Power:\u003c\/strong\u003e 120–240 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e 20 standard 24 VDC, 4 fast 24 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e 16 relay outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O:\u003c\/strong\u003e 24 inputs, 16 outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Circuit Type:\u003c\/strong\u003e 24 VDC sink\/source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Circuit Type:\u003c\/strong\u003e Relay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay Contact Rating:\u003c\/strong\u003e 24–125 VDC; 120–240 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 20,000,000 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLoad Current Capacity:\u003c\/strong\u003e Minimum 10 A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 47–63 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0–50 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAmbient Operating Temperature:\u003c\/strong\u003e 0–55 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40–85 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInternal Power Supply:\u003c\/strong\u003e Integrated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Usage:\u003c\/strong\u003e 82 VA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 25 A for 8 ms at 120 VAC; 40 A for 4 ms at 240 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e1762-L40BWA\u003c\/strong\u003e is suitable for machine control, packaging systems, and process automation where compact size and reliable relay outputs are required. Its wide input voltage range and robust relay contacts make it adaptable for both DC and AC load control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of outputs does this controller provide?\u003c\/strong\u003e  A: It features 16 relay outputs, suitable for switching both AC and DC loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the power supply built into the unit?\u003c\/strong\u003e  A: Yes, the controller includes an internal power supply, eliminating the need for external modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many fast inputs are available?\u003c\/strong\u003e  A: Four fast 24 VDC inputs are provided for high-speed signal processing.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52301059621173,"sku":"1762-L40BWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L40BWA.jpg?v=1770276903"},{"product_id":"allen-bradley-micrologix-1000-1761-l32bwa-32-point-programmable-controller","title":"Allen Bradley MicroLogix 1000 | 1761-L32BWA | 32-Point Programmable Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1761-L32BWA\u003c\/strong\u003e is a MicroLogix 1000 series programmable logic controller (PLC) designed for compact automation systems requiring reliable digital input and relay output control. With 32 I\/O points, integrated EEPROM memory, and RS-232 communication, this controller provides dependable performance for small-scale industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e MicroLogix 1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e Programmable Logic Controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e \u003cstrong\u003e1761-L32BWA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lbs (0.91 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Count:\u003c\/strong\u003e 32 points total\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e 20 DC inputs (sinking\/sourcing, 14–30 VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e 12 relay contact outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory:\u003c\/strong\u003e 1K EEPROM (approx. 737 instruction words, 437 data words)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Port:\u003c\/strong\u003e RS-232, DF1 protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Feature:\u003c\/strong\u003e Master Control Relay (MCR)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 120\/240 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Power Consumption:\u003c\/strong\u003e 16 VA @ 120 VAC; 22 VA @ 240 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 30 A for 4 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Frequency:\u003c\/strong\u003e 47–63 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Endurance:\u003c\/strong\u003e 50,000 cycles minimum\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 10 G operating, 20 G non-operating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e DIN rail or panel screws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 7.87 × 2.87 × 3.15 in.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status:\u003c\/strong\u003e Discontinued \/ Obsolete\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e1761-L32BWA\u003c\/strong\u003e is suitable for small machine control, packaging systems, and basic automation tasks. Its relay outputs make it ideal for switching AC and DC loads, while the RS-232 port ensures straightforward integration with legacy communication networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many inputs and outputs does this controller support?\u003c\/strong\u003e  A: It provides 20 DC inputs and 12 relay outputs, totaling 32 I\/O points.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of communication protocol is used?\u003c\/strong\u003e  A: The controller supports RS-232 communication using the DF1 protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this model still in production?\u003c\/strong\u003e  A: No, the \u003cstrong\u003e1761-L32BWA\u003c\/strong\u003e is discontinued\/obsolete but remains widely used in legacy systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the isolation voltage rating?\u003c\/strong\u003e  A: The module is rated at 1500 VDC isolation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52301111591221,"sku":"1761-L32BWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-L32BWA.jpg?v=1770279111"},{"product_id":"1762-l40bxbr-allen-bradley-micrologix-1200-40-point-programmable-controller","title":"1762-L40BXBR | Allen-Bradley MicroLogix 1200 40-Point Programmable Controller","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1762-L40BXBR MicroLogix 1200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 40-point programmable logic controller combining digital inputs and outputs for flexible machine control. It includes 24 standard 24V DC inputs, 4 high-speed DC inputs, 8 relay outputs, 7 standard 24V DC FET outputs, and 1 high-speed 24V DC FET output. The controller supports DF1, DH-485, ASCII, and MODBUS communication protocols via serial and programming ports. Designed for reliable operation, it functions in 0–55°C ambient temperatures, withstands 30G shock and 5G vibration, and operates on a 24V DC power supply with 40W typical consumption and 27.9W heat dissipation. Its relay outputs handle 24–125V DC or 120–240V AC with a 10A load, while FET outputs deliver 500–600mA per channel. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXBR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for small- to medium-scale automation systems requiring precise input\/output management and robust communication.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXBR\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley (Rockwell Automation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40-Point Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 standard 24V DC; 4 high-speed 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 relay; 7 24V DC FET; 1 high-speed 24V DC FET\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125V DC, 120–240V AC, 10A load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFET Output Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500mA at 24V DC, 600mA at 5V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC, 82 VA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 W typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e27.9 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 8-pin mini-DIN serial port, 1 programming port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDF1, DH-485, ASCII, MODBUS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–55°C (32–131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Shock:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e30G\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5G, 10–500 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Relay Life:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20,000,000 cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.91 kg (2.00 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXBR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suited for small to medium-scale automation applications such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMachine control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaterial handling systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePackaging machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment requiring mixed relay and FET outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 1762-L40BXBR handle high-speed input counting?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, it includes 4 fast 24V DC inputs for high-speed signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Which protocols are supported for communication?\u003c\/strong\u003e\u003cbr\u003eA2: DF1, DH-485, ASCII, and MODBUS protocols are supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum relay load?\u003c\/strong\u003e\u003cbr\u003eA3: Each relay can handle up to 10A at 24–125V DC or 120–240V AC.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52317351969077,"sku":"1762-L40BXBR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L40BXBR.jpg?v=1770790502"},{"product_id":"allen-bradley-1766-mm1-micrologix-1400-memory-module","title":"Allen Bradley 1766-MM1 MicroLogix 1400 Memory Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e  The Allen Bradley MicroLogix 1400 series \u003cstrong\u003e1766-MM1\u003c\/strong\u003e memory module is engineered to provide secure and reliable storage for user programs and data. Designed for seamless integration with supported controllers, it ensures operational continuity and enhances system safety in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e MicroLogix 1400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e Memory Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel\/Part Number\u003c\/strong\u003e \u003cstrong\u003e1766-MM1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 0.06 lbs (0.03 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUser Memory Capacity\u003c\/strong\u003e 384 KB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Controllers\u003c\/strong\u003e 1766-L32AWA, 1766-L32AWAA, 1766-L32BWA, 1766-L32BWAA, 1766-L32BXB, 1766-L32BXBA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e Backup of user programs and data, program transfer between controllers, enhanced safety\/security for press control and critical applications, automatic recovery after controller fault, program comparison, data file and module write protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e Dedicated memory module slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e 0–55 °C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAutomatic Loading\u003c\/strong\u003e Supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBit Control\u003c\/strong\u003e S:1\/11 “Load Memory Module Always”\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStatus Bits\u003c\/strong\u003e S:1\/10, S:1\/11, S:1\/12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e  This module is particularly suited for environments requiring high reliability, such as press control systems, automated manufacturing lines, and safety-critical industrial processes. Its ability to store and protect programs ensures minimal downtime and secure operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can the 1766-MM1 be used across multiple controllers?\u003c\/strong\u003e  \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it supports program transport between compatible MicroLogix 1400 controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the module provide protection against accidental overwrites?\u003c\/strong\u003e  \u003cstrong\u003eA:\u003c\/strong\u003e Yes, it includes write protection for both data files and the memory module itself.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What happens if the controller experiences a fault?\u003c\/strong\u003e  \u003cstrong\u003eA:\u003c\/strong\u003e The module supports auto-recovery through a power cycle, ensuring quick restoration of operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eComparison with Similar Models\u003c\/strong\u003e  Compared to smaller memory modules in the MicroLogix family, the \u003cstrong\u003e1766-MM1\u003c\/strong\u003e offers a larger 384 KB capacity, making it more suitable for complex applications requiring extensive program storage and data handling.\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52317366059317,"sku":"1766-MM1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1766-MM1_91f0a2fe-9f40-4a08-b688-217bd34aca20.jpg?v=1770791830"},{"product_id":"allen-bradley-1761-net-eni-micrologix-ethernet-interface-module","title":"Allen-Bradley 1761-NET-ENI MicroLogix Ethernet Interface Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-ENI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet Interface Module from Allen-Bradley enables MicroLogix and CompactLogix controllers to communicate over Ethernet\/IP networks. It converts DF1 serial data into Ethernet packets, allowing efficient data exchange between PLCs, HMIs, and SCADA systems. Designed for robust industrial performance, the module supports both 10 Mbps and 100 Mbps transmission speeds, depending on the hardware series.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel \/ Part Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-ENI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1000\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEthernet Interface Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCategory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC Communication Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocols:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDF1 Full-Duplex and Ethernet\/IP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePorts:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 total (1 RS-232 serial, 1 Ethernet\/IP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Speed:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries A\/B – 10 Mbps; Series C\/D – 10\/100 Mbps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20.4–26.4 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 mA typical, 100 mA maximum at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDC-powered\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e710 V DC for one minute\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Options:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN rail or panel mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCat5, Cat5e, Cat6, Cat6e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Feature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated Master Control Relay (MCR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIEC801-2, 3, 4, 5, and 6 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to +60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-45°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.44 lbs (0.20 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Lifecycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscontinued \/ Obsolete\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-ENI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used to integrate MicroLogix PLCs with Ethernet-based control networks. It is ideal for applications requiring remote monitoring, SCADA communication, or PLC-to-PLC messaging. Common environments include process control, packaging systems, and distributed automation networks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the 1761-NET-ENI module do?\u003c\/strong\u003e\u003cbr\u003eA: It provides Ethernet\/IP connectivity to MicroLogix controllers by translating DF1 serial data into Ethernet packets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with CompactLogix systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it can communicate with CompactLogix controllers using standard Ethernet\/IP protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What’s the difference between Series A\/B and Series C\/D?\u003c\/strong\u003e\u003cbr\u003eA: Series A and B support 10 Mbps Ethernet, while Series C and D support 10\/100 Mbps communication speeds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power source is required?\u003c\/strong\u003e\u003cbr\u003eA: The module operates on a 24 V DC power supply with a typical current draw of 50 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this model still in production?\u003c\/strong\u003e\u003cbr\u003eA: No, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1761-NET-ENI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas been discontinued but remains supported through replacements and refurbished units.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52317704225077,"sku":"1761-NET-ENI","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-NET-ENI.jpg?v=1770799828"},{"product_id":"1766-l32bxb-allen-bradley-micrologix-1400-programmable-controller","title":"1766-L32BXB | Allen-Bradley | MicroLogix 1400 Programmable Controller","description":"\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1766-L32BXB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1400 is a compact, high-performance programmable controller designed for control and automation tasks in industrial environments. With 32 I\/O points, an Ethernet interface, and a flexible range of operating conditions, it’s ideal for use in diverse applications where reliability and scalability are required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32BXB\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e: 1766-L32BXB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: MicroLogix 1400 Programmable Controller\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e: 20 digital inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 12 relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal I\/O\u003c\/strong\u003e: 32 (digital)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: Digital\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e: Ethernet for easy integration with existing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Type\u003c\/strong\u003e: DIN Rail for simple installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e: 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Operating Temperature\u003c\/strong\u003e: -20°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Operating Temperature\u003c\/strong\u003e: +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions (LxWxH)\u003c\/strong\u003e: 18 cm x 8.7 cm x 9 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.9 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix 1400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis well-suited for small to medium-sized automation projects, particularly in areas where space is limited and reliable control is critical. Common applications include packaging, machinery control, and process monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many inputs and outputs does the\u003cspan\u003e \u003c\/span\u003e1766-L32BXB\u003cspan\u003e \u003c\/span\u003ehave?\u003c\/strong\u003e\u003cbr\u003eA: This controller provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 digital inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 relay outputs\u003c\/strong\u003e, offering a total of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 I\/O points\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this controller be mounted easily?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix 1400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN Rail mounting\u003c\/strong\u003e, ensuring quick and secure installation in control panels or cabinets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the operating temperature range for this model?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32BXB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates in a temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-20°C to +60°C\u003c\/strong\u003e, making it suitable for various industrial environments.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52324930421045,"sku":"1766-L32BXB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1766-L32BXBA.jpg?v=1771062751"},{"product_id":"allen-bradley-micrologix-1400-1766-l32bxba-programmable-controller","title":"Allen-Bradley MicroLogix 1400 | 1766-L32BXBA | Programmable Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen-Bradley 1766-L32BXBA MicroLogix 1400\u003c\/strong\u003e controller is engineered for versatile automation tasks, offering a balanced mix of digital and analog I\/O, multiple communication options, and reliable performance in industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen-Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e MicroLogix 1400\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1766-L32BXBA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 1.75 lbs (0.79 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Capacity\u003c\/strong\u003e 32 points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e 12 fast 24V DC, 8 standard 24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e 0–24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e 6 relay, 3 fast 24V DC, 3 standard 24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelay Output Range\u003c\/strong\u003e 5–125V DC \/ 5–264V AC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e 2 voltage channels (0–10V DC, 1 LSB resolution)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e 2 voltage channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e 47–63 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e 24V DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e 15 A for 20 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e 1 isolated RS232\/RS485 combo, 1 non-isolated RS232, 1 Ethernet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e DF1, ASCII, Modbus RTU, DNP3, DH485, Ethernet\/IP, Modbus TCP\/IP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e 20 KB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSpecial Features\u003c\/strong\u003e Built-in real-time clock (RTC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMachine-level control with mixed signal requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-speed input\/output operations such as counters and pulse detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRemote monitoring and SCADA integration via Ethernet\/IP or Modbus TCP\/IP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact automation systems requiring reliable relay and DC outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Can expansion modules be added to this controller?\u003c\/strong\u003e  A: Yes, the MicroLogix 1400 series supports expansion I\/O modules for extended functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What is the advantage of fast DC inputs and outputs?\u003c\/strong\u003e  A: They are optimized for high-speed applications, ensuring accurate detection of pulses and rapid switching.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is the Ethernet port suitable for SCADA integration?\u003c\/strong\u003e  A: Yes, it supports Ethernet\/IP and Modbus TCP\/IP, making it compatible with most SCADA systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparison with Similar Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1766-L32AWA\u003c\/strong\u003e: AC-powered variant, suitable for installations without DC supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1766-L32BXB\u003c\/strong\u003e: Similar configuration but excludes relay outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1766-L32BXBA\u003c\/strong\u003e: Offers both relay and DC outputs, ideal for hybrid applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52364899713333,"sku":"1766-L32BXBA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1766-L32BXBA_6d3880c4-a8da-40e8-8212-4276e8040bd8.jpg?v=1771900738"},{"product_id":"1761-l32bwb-allen-bradley-micrologix-1000-programmable-logic-controller","title":"1761-L32BWB | Allen-Bradley  MicroLogix 1000 Programmable Logic Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen-Bradley 1761-L32BWB MicroLogix 1000\u003c\/strong\u003e is a compact PLC designed for small-scale automation tasks. It provides 32 I\/O points, relay outputs, and digital inputs with EEPROM memory for program storage. Equipped with RS-232 communication and DF1 protocol support, it offers reliable control for basic machine operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e Allen-Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e MicroLogix 1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e Programmable Logic Controller (PLC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e \u003cstrong\u003e1761-L32BWB\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e 1.00 lbs (0.45 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e 20 digital inputs (sinking\/sourcing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e 14–30 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e 12 relay outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOutput Current Range\u003c\/strong\u003e 4–20 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Count\u003c\/strong\u003e 32 points total\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e 1K EEPROM (approx. 737 instruction words, 437 data words)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e RS-232\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e DF1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSafety Feature\u003c\/strong\u003e Master Control Relay\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e 20.4–26.4 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Power Consumption\u003c\/strong\u003e 7 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e 30 A for 4 ms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e 47–63 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Shock\u003c\/strong\u003e 10 G\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNon-Operating Shock\u003c\/strong\u003e 20 G\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMinimum Power Cycles\u003c\/strong\u003e 50,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e 7.87 x 1.57 x 3.15 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e Discontinued\/Obsolete\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eApplication Scenarios\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall machine control requiring basic relay outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM equipment with limited I\/O requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCost-effective automation for standalone systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy installations where MicroLogix 1000 controllers are still in use\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFAQ\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How many I\/O points does the 1761-L32BWB provide?\u003c\/strong\u003e  A: It provides 32 points (20 inputs and 12 relay outputs).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: What type of communication is supported?\u003c\/strong\u003e  A: RS-232 communication using DF1 protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Is this model still in production?\u003c\/strong\u003e  A: No, it is discontinued\/obsolete but may be available through aftermarket suppliers.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eComparison with Similar Models\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1761-L16BWB\u003c\/strong\u003e: Smaller I\/O capacity with fewer inputs and outputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1761-L32BWB\u003c\/strong\u003e: Mid-range option with 32 I\/O points.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1762-L24BWA (MicroLogix 1200)\u003c\/strong\u003e: Successor series with expanded features and memory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52365722419509,"sku":"1761-L32BWB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-L32BWB.jpg?v=1771915508"},{"product_id":"1762-l40bxb-allen-bradley-micrologix-1200-programmable-logic-controller-24v-dc","title":"1762-L40BXB | Allen Bradley MicroLogix 1200 Programmable Logic Controller 24V DC","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXB (Part Number 1762-L40BXB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, small-scale programmable logic controller designed for industrial automation systems requiring a balance of compact design and high I\/O counts. Operating on a 24V DC power supply, this MicroLogix 1200 unit features 40 embedded I\/O points, including specialized high-speed inputs and FET outputs tailored for motion control and precise event-timing applications.\u003c\/p\u003e\n\u003cp\u003eDesigned for both stand-alone and networked operation, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXB (1762-L40BXB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports sophisticated instruction sets via RSLogix 500 software. Its integrated RS-232C port allows for flexible serial communication with HMIs, programming terminals, and other controllers via Modbus RTU or DF1 protocols. Although the series reached its end-of-life status in late 2021, it remains a cornerstone for maintaining and expanding legacy industrial machinery and distributed control nodes.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC (SELV Class 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Digital Inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 (20 Standard 24V DC and 4 Fast 24V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Channels (Up to 20 kHz support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Digital Outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Relay Contacts and 8 24V DC FET (Source)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Load Rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125V DC; 120–240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFET High-Speed Output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 Channel (Supports pulse train output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProgram Memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6 KB User Memory (4KB Program \/ 2KB Data)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolated RS-232C (8-pin Mini-DIN)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus RTU, DF1, DH-485, ASCII\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to six 1762 expansion modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 55 °C (32 to 131 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 mm Height x 160 mm Width x 87 mm Depth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.44 lbs (0.65 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Functional Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXB (1762-L40BXB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered for reliability in demanding machine-level environments\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual output technology allows for switching high-current AC\/DC loads via relays while simultaneously providing high-frequency pulses via FETs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmbedded 20 kHz high-speed counter provides accurate tracking for encoders and high-speed motion sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRobust 24V DC architecture is ideal for battery-backed systems and vehicles where AC power is unavailable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-rail or panel-mounting versatility facilitates integration into tight control cabinet footprints.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhich programming software is required for this controller?\u003c\/strong\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BXB (Part Number 1762-L40BXB)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis programmed using RSLogix 500. It is also compatible with Connected Components Workbench (CCW) for basic configuration and monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module to control a stepper motor?\u003c\/strong\u003eYes, the integrated high-speed FET output is capable of generating Pulse Train Outputs (PTO) for simple open-loop motion control of stepper or servo drives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum I\/O count after expansion?\u003c\/strong\u003eWhile the base unit has 40 points, adding six maximum 1762 expansion modules can significantly increase the total point count and add analog or temperature sensing capabilities.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52380441706805,"sku":"1762-L40BXB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L40BXB.jpg?v=1772160601"},{"product_id":"1762-l40bwar-allen-bradley-micrologix-1200-40-point-plc-controlle","title":"1762-L40BWAR | Allen-Bradley MicroLogix 1200 40-Point PLC Controlle","description":"\u003ch3\u003eSystem Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile and compact programmable logic controller (PLC) from the MicroLogix 1200 family, designed to handle moderate to complex automation tasks.\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-143 citation-end-143\"\u003eThis 40-point unit provides a high-density I\/O count, featuring a mix of 24V DC discrete inputs and robust relay outputs.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIt is powered by a wide-range AC input, making it suitable for global industrial applications where varying voltage standards are present. The controller is engineered for field-expandability, allowing users to add 1762 expansion I\/O modules to meet growing system requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Characteristics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-142\"\u003e\u003c\/span\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan class=\"citation-142 citation-end-142\"\u003e: Allen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Series\u003c\/strong\u003e: MicroLogix 1200\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-141\"\u003e\u003c\/span\u003e\u003cstrong\u003eTotal I\/O Count\u003c\/strong\u003e\u003cspan class=\"citation-141 citation-end-141\"\u003e: 40 Points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e: 24 DC Inputs (20 standard and 4 high-speed ports)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-140\"\u003e\u003c\/span\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e\u003cspan class=\"citation-140 citation-end-140\"\u003e: 16 Relay Outputs (form A and form C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-139\"\u003e\u003c\/span\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003cspan class=\"citation-139 citation-end-139\"\u003e: 120V to 240V AC (Operating range 85–264V AC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-138\"\u003e\u003c\/span\u003e\u003cstrong\u003eInput Circuit Type\u003c\/strong\u003e\u003cspan class=\"citation-138 citation-end-138\"\u003e: Sink\/Source (User-configurable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Contact Rating\u003c\/strong\u003e: 24–125V DC; 120–240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-137\"\u003e\u003c\/span\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003cspan class=\"citation-137 citation-end-137\"\u003e: 8-pin mini-DIN RS-232 port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e: DF1, DH-485, Modbus RTU Slave, and ASCII\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e: 25A for 8ms (120V AC); 40A for 4ms (240V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e: 22 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e: 6KB non-volatile (User program and data)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Weight\u003c\/strong\u003e: 1.67 kg (3.69 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Features and Programming\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-136\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e\u003cspan class=\"citation-136 citation-end-136\"\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for applications requiring reliable relay switching and high-speed counting.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThe four integrated high-speed inputs allow for interfacing with encoders or flow meters at rates up to 20 kHz. System configuration is typically performed using RSLogix 500 software, providing a stable ladder-logic environment for industrial sequencing and machine control. Its relay outputs are rated for over 20 million mechanical cycles, ensuring longevity in high-cycle packaging, material handling, and HVAC control systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1762-L40BWAR support memory expansion?\u003c\/strong\u003eWhile the internal memory is fixed at 6KB, the unit supports the use of a 1762-MM1 memory module for program backup and transport between controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I communicate with a modern PC without a serial port?\u003c\/strong\u003eTo program the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40BWAR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing a modern computer, a 1747-UIC (USB to DH-485) or a high-quality USB-to-RS232 converter (such as the 9300-USBS) is required to interface with the mini-DIN port.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52381162144053,"sku":"1762-L40BWAR","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L40BWAR.jpg?v=1772180356"},{"product_id":"allen-bradley-1762-it4-micrologix-1200-thermocouple-mv-4-channel-input-module","title":"Allen Bradley 1762-IT4 MicroLogix 1200 Thermocouple\/mV 4-Channel Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eAllen Bradley 1762-IT4\u003c\/strong\u003e is a thermocouple and millivolt input module designed for the MicroLogix 1200 platform. It provides four input channels plus one cold junction compensation (CJC) sensor, supporting a wide range of thermocouple types and millivolt signals. With delta-sigma conversion, programmable notch filtering, and automatic calibration, this module ensures accurate and stable temperature measurement in industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen Bradley\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 1762-IT4\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line:\u003c\/strong\u003e MicroLogix 1200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Thermocouple\/mV Input Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.25 lbs (≈ 0.11 kg)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 4 channels + 1 CJC sensor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Thermocouple Types:\u003c\/strong\u003e J, K, T, E, R, S, B, N, C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSupported Millivolt Signals:\u003c\/strong\u003e ±50 mV, ±100 mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConverter Type:\u003c\/strong\u003e Delta-Sigma\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 15-bit plus sign\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFilter Frequencies:\u003c\/strong\u003e 10 Hz, 50 Hz, 60 Hz, 250 Hz, 500 Hz, 1 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eChannel Update Times:\u003c\/strong\u003e 303 ms, 63 ms, 53 ms, 15 ms, 9 ms, 7 ms (depending on filter setting)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e Automatic at power-up, programmable calibration supported\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCJC Sensor Accuracy:\u003c\/strong\u003e ±1.3 °C (±2.54 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw @ 5.1 VDC:\u003c\/strong\u003e 40 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw @ 24 VDC:\u003c\/strong\u003e 50 mA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation:\u003c\/strong\u003e 1.5 W max\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Open-type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0–55 °C (32–131 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40–85 °C (-40–185 °F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 5 g @ 10–500 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e 30 g\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eThe 1762-IT4 is ideal for process control systems requiring precise temperature monitoring, such as furnaces, kilns, and industrial ovens. Its compatibility with multiple thermocouple types makes it versatile for diverse applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eComparison with Similar Modules\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1762-IT4:\u003c\/strong\u003e 4-channel thermocouple\/mV input, CJC sensor included, delta-sigma conversion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOther MicroLogix input modules: May support analog voltage\/current inputs but lack dedicated thermocouple compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: Does the 1762-IT4 support millivolt signals in addition to thermocouples?\u003c\/strong\u003e  A: Yes, it supports ±50 mV and ±100 mV ranges.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eQ: How accurate is the CJC sensor?\u003c\/strong\u003e  A: The cold junction compensation sensor has an accuracy of ±1.3 °C (±2.54 °F).\u003c\/span\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52390893814069,"sku":"1762-IT4","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-IT4.jpg?v=1772437453"},{"product_id":"allen-bradley-micrologix-1400-1766-l32awaa-32-point-ac-relay-controller-with-analog-i-o","title":"Allen-Bradley MicroLogix 1400 1766-L32AWAA 32-Point AC\/Relay Controller with Analog I\/O","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32AWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a premium, all-in-one programmable logic controller within the MicroLogix 1400 family. Designed for sophisticated small-scale automation, this \"AWAA\" variant distinguishes itself by combining high-voltage AC discrete I\/O with embedded 12-bit analog capabilities. It features a built-in LCD for real-time diagnostics and data manipulation, along with extensive communication options including EtherNet\/IP. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32AWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis particularly effective for HVAC, water treatment, and standalone machine control where a mix of digital sensors, relay actuators, and analog process variables (like temperature or pressure) must be managed by a single, compact device.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32AWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the central intelligence of the system, offering a rich set of embedded I\/O that can be further expanded via 1762 series modules.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eController Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1400 (Base Unit)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110V to 240V AC (Operating range 100–240V AC @ 47–63 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 Points (120V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 Points (Relay, Normally Open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 Channels (12-bit Voltage, 0–10V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnalog Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Channels (12-bit Voltage, 0–10V DC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e20 KB (10 KB for user program \/ 10 KB for data)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\/Recipe Storage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e128 KB for logging \/ 64 KB for recipes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* Port 0: 8-pin Mini DIN (RS-232\/RS-485)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePort 1: RJ45 (EtherNet\/IP, DNP3 over IP, Modbus TCP\/IP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePort 2: 9-pin D-Shell (Isolated RS-232)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExpansion Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports up to seven (7) 1762 MicroLogix expansion modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.45 lbs (1.11 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAdvanced Interface and Connectivity\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOne of the defining features of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32AWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the integrated backlit LCD. This interface allows maintenance personnel to monitor I\/O status, change network configurations (such as IP addresses), and modify integer values without a laptop. For networked environments, its dual serial ports and dedicated Ethernet port support multi-protocol communication, enabling the controller to act as a bridge between legacy Modbus devices and modern SCADA systems via EtherNet\/IP.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eIntegrated Analog Capabilities\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eUnlike the standard AWA model, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32AWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes 4 voltage inputs and 2 voltage outputs directly on the base unit. These 12-bit channels provide sufficient resolution for typical industrial feedback loops, such as regulating the speed of a Variable Frequency Drive (VFD) via the 0–10V analog output or monitoring a level sensor on the input. Because these are built-in, they do not occupy expansion slots, leaving all seven expansion positions available for additional digital, specialty, or temperature modules.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the analog inputs on the 1766-L32AWAA be used for 4-20mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNatively, the embedded analog ports are designed for 0–10V DC. To use a 4-20mA sensor, you must place a high-precision 500-ohm resistor across the input terminals to convert the current to a 2–10V signal, or add a dedicated 1762-IF4 analog expansion module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this AC-powered model support High-Speed Counters (HSC)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. High-speed counting (up to 100 kHz) is only available on MicroLogix 1400 models with 24V DC inputs. The 120V AC inputs on this model are intended for standard discrete logic and do not support high-frequency pulse detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the real-time clock (RTC) maintained during power loss?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1766-L32AWAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes a replaceable lithium battery (1747-BA) that maintains the RTC and the volatile RAM memory for several years under normal conditions.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457444671797,"sku":"1766-L32AWAA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1766-L32AWAA.jpg?v=1773979288"},{"product_id":"1762-if2of2-allen-bradley-micrologix-4-channel-analog-combination-i-o-module","title":"1762-IF2OF2 | Allen-Bradley MicroLogix | 4-Channel Analog Combination I\/O Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, high-efficiency analog combination module designed for the Allen-Bradley MicroLogix 1100, 1200, and 1400 controller series. By providing two differential input channels and two single-ended output channels in a single-slot housing, it offers a cost-effective solution for small-scale PID loop control and process monitoring. This module is engineered to interface with a broad spectrum of industrial instrumentation, including pressure transmitters, flow meters, and variable frequency drives (VFDs), ensuring high-fidelity signal conversion in space-constrained control panels.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 12-bit monotonic resolution, providing 4,096 discrete counts to represent the full range of the analog signal.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\/O Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Differential Inputs \/ 2 Single-Ended Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10V DC and 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Signal Ranges:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0 to 10V DC and 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12-Bit Unipolar\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Formats:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRaw\/Proportional (0–31,208) and Scaled-for-PID (0–16,383)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current Draw:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 mA at 5V DC \/ 105 mA at 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e200 kΩ (Voltage) \/ 250 Ω (Current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Load Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u0026gt; 1 kΩ (Voltage) \/ \u0026lt; 500 Ω (Current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e500 Hz Digital Filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.5% of Full Scale (Inputs) \/ ±1.0% of Full Scale (Outputs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-20°C to 65°C (-4°F to 149°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Location Rating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClass I, Division 2, Groups A, B, C, D\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.52 lbs (0.24 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAdvanced Diagnostics and Reliability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eTo ensure system integrity, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes onboard diagnostic bit reporting. The module monitors for \"Over-Range\" and \"Under-Range\" conditions, immediately notifying the MicroLogix CPU if a field signal falls outside the calibrated 4–20mA or 0–10V window. This is particularly vital for detecting sensor failures or broken wire conditions in critical feedback loops. Additionally, the module features high-voltage isolation between the field-side signals and the logic-side backplane, protecting the PLC processor from external electrical transients.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation and Hardware Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for easy DIN rail mounting and includes a removable terminal block (RTB) for simplified wiring. For current-loop applications, the module utilizes internal 250-ohm precision resistors; however, it is important to note that the module does not provide loop power. An external 24V DC power supply must be wired in series with the transmitter and the module inputs. During installation, proper grounding of the cable shields to the PLC's chassis ground is required to maintain the 12-bit signal accuracy in noisy industrial environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use one channel for Voltage and another for Current simultaneously?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Each input and output channel is individually wired and configured. You can monitor a 0–10V pressure transducer on Input 0 while driving a 4–20mA VFD command on Output 0.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with the MicroLogix 1500?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. While the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary expansion for the MicroLogix 1100, 1200, and 1400, it is also fully compatible with the 1764-based MicroLogix 1500 platform using the 1762 expansion bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require software calibration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-IF2OF2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis factory-calibrated. However, in RSLogix 500 or CCW software, you must select the correct \"Data Format\" (Raw\/Proportional vs. Scaled-for-PID) to ensure the PLC registers match your logic requirements.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457677750581,"sku":"1769-IF2OF2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1769-IF2OF2.jpg?v=1773986574"},{"product_id":"allen-bradley-micrologix-1762-ow16-16-point-ac-dc-relay-output-module","title":"Allen-Bradley MicroLogix 1762-OW16 16-Point AC\/DC Relay Output Module","description":"\u003ch2\u003e\u003cstrong\u003eModule Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density discrete output module designed for the Allen-Bradley MicroLogix 1100, 1200, and 1400 controller families. Featuring 16 independent relay contacts, this module provides the versatility to switch a wide range of AC and DC voltages, making it an essential component for controlling solenoids, motor starters, and indicator lamps. Its electromechanical relay design offers complete electrical isolation between the PLC logic and the field-side loads, ensuring robust performance in electrically noisy industrial environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eDetailed Engineering Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis organized into two isolated groups, allowing for the control of different voltage levels within a single expansion slot.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Relay Output (Normally Open)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Groups:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2 Isolated Groups (8 points per group)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5V to 265V AC \/ 5V to 125V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Contact Ratings:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–125V DC \/ 120–240V AC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current per Point:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.5 Amperes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Current per Module:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Amperes (total)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Delay (Typical):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 milliseconds (On and Off)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current (5V DC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e120 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Current (24V DC):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e140 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Heat Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6.1 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e265V (Continuous), reinforced insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Termination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemovable Terminal Block (RTB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0°C to 55°C (32°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.69 lbs (0.31 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFlexible Load Management\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eA primary advantage of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis its \"dry contact\" architecture. Because each of the two groups has its own common (VAC\/VDC COM), you can simultaneously control a 120V AC lighting circuit on Group 0 and a 24V DC hydraulic valve on Group 1. This flexibility eliminates the need for interposing relays in many applications, simplifying cabinet wiring and reducing overall system cost.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation and Mechanical Reliability\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe module is designed for easy DIN rail mounting and features a compact 1762-series footprint. To ensure long-term reliability of the relay contacts when switching inductive loads (such as motor starter coils or solenoids), it is highly recommended to install external surge suppression. Using a snubber circuit for AC loads or a diode for DC loads will prevent contact arcing and significantly extend the mechanical life of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW16\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum load requirement for these relays?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile there is no strict minimum current for operation, very low-current signals (under 10mA) may experience higher contact resistance over time due to the lack of \"wetting current\" needed to clean the relay contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace the individual relays if one fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The relays are soldered directly to the internal PCB of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OW16\u003c\/strong\u003e. If a contact fails, the entire module or the removable terminal block must be addressed, though the terminal block itself is replaceable for quick hardware swaps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module draws its logic power (5V and 24V) from the MicroLogix controller’s backplane. However, the power for the actual field loads must be provided by an external source connected to the \"COM\" terminals of the module.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52457690399029,"sku":"1762-QW16","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-QW162.jpg?v=1773987275"},{"product_id":"1762-ob32t-allen-bradley-micrologix-32-point-source-output-module","title":"1762-OB32T | Allen-Bradley | MicroLogix 32-Point Source Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T \u003c\/strong\u003eis a high-density digital expansion module designed for the MicroLogix 1100, 1200, and 1500 controller families. This solid-state component provides thirty-two sourcing outputs in a compact form factor, significantly increasing the I\/O capacity of a PLC system without requiring additional rack space. By utilizing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e, engineers can drive multiple 24V DC field devices, such as solenoids, interface relays, and indicator lamps, with high reliability and rapid switching speeds.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllen-Bradley \/ Rockwell Automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1762 Expansion I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-State Sourcing (Source)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTwo (2) isolated groups of 16 channels each\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10.2V to 26.4V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Rating (Per Channel)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 A at 60 °C (140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Rating (Per Group)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 A at 60 °C (140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Rating (Total Module)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4.0 A at 60 °C (140 °F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSurge Current Capacity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2.0 A (Repeatable every 2s for 10ms at 60 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum On-State Current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Heat Dissipation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3.4 Watts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupported Wire Sizes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e22 AWG, 24 AWG, and 26 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.31 lbs (0.14 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eHardware Installation and Thermal Management\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a high-density design that requires careful attention to thermal loads. To maintain the 0.5 A per channel rating at elevated temperatures (60 °C), ensure that the total module current does not exceed 4.0 A. The module utilizes a ribbon-cable or high-density connector interface rather than traditional screw terminals to accommodate the 32-point count within a small footprint. It is recommended to use pre-wired cable assemblies to simplify integration and reduce wiring errors.\u003c\/p\u003e\n\u003ch2\u003eComparison: 1762-OB32T vs. 1762-OB16\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDensity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides double the output capacity in the same physical width as the 16-point 1762-OB16 module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhile the OB16 uses standard terminal blocks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizes a high-density connector, often requiring an external terminal interface for field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIdeal for systems with high actuator counts where panel space is strictly limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupport sinking output configurations?\u003c\/p\u003e\n\u003cp\u003eNo, this module is strictly a \"Sourcing\" (Source) output type, meaning it provides the positive side of the 24V DC circuit to the load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if an output is short-circuited?\u003c\/p\u003e\n\u003cp\u003eWhile solid-state, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-OB32T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be protected by external fuses. Exceeding the 2.0 A surge rating or 0.5 A continuous rating per channel may cause permanent damage to the output transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this module compatible with the MicroLogix 1000?\u003c\/p\u003e\n\u003cp\u003eNo, the 1762 expansion series is only compatible with the MicroLogix 1100, 1200, and 1500 series controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52458173464885,"sku":"1762-OB32T","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-OB32T.jpg?v=1774000421"},{"product_id":"allen-bradley-1761-l32aaa-micrologix-1000-programmable-logic-controller","title":"Allen Bradley 1761-L32AAA MicroLogix 1000 Programmable Logic Controller","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1761-L32AAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a self-contained, compact Programmable Logic Controller (PLC) within the MicroLogix 1000 family. This unit provides a high-density I\/O solution in a small footprint, managing 32 discrete points to automate small-scale industrial processes. While the manufacturer classifies this series as discontinued, we provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It excels in applications requiring 120V AC signaling and solid-state AC switching for high-cycle operations.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe 1761-L32AAA integrates logic, power, and I\/O into a single chassis with the following parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Total Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 Integrated 120V AC Digital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Triac Outputs; 2 Relay (Contact) Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 \/ 240V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30A for 8 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1K EEPROM (737 Instruction Words)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in RS-232 (DF1 Protocol)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Feature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMaster Control Relay support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.94 lbs (0.88 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for High-Cycle AC Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated Triac outputs handle frequent switching of AC loads without the mechanical wear associated with traditional relays. This significantly extends the operational lifespan of the controller in high-speed packaging or sorting applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined AC Signal Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing 120V AC inputs directly, the 1761-L32AAA eliminates the need for interposing relays or voltage converters when interfacing with standard industrial pushbuttons and limit switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged All-in-One Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact housing contains the power supply, CPU, and I\/O. This \"Brick\" style design simplifies installation in narrow control cabinets where space prohibits the use of modular rack-based systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Data Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1K EEPROM memory stores the user program and data without requiring a battery backup. This ensures the PLC retains its logic and configuration through extended power outages or long-term storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Local Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe Master Control Relay (MCR) feature provides a hardware-level safety zones, allowing engineers to disable all outputs quickly during an emergency stop condition while maintaining the CPU's operational state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 1761-L32AAA handle DC input signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1761-L32AAA features 120V AC inputs. Applying 24V DC to these terminals will fail to trigger the input logic. Always verify your field device voltage before wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of having both Triac and Relay outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ten Triac outputs provide wear-free switching for standard AC solenoids and starters. The two integrated Relay outputs provide dry-contact flexibility for auxiliary signals or isolated circuits that require different voltage levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or used \"New-Old-Stock\" unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee this 1761-L32AAA is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It remains in its factory-sealed packaging, ensuring it meets all original Allen Bradley electrical and performance specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I program this controller since it is discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1761-L32AAA uses RSLogix 500 software. Connection requires the built-in RS-232 port and a 1761-CBL-PM02 cable (or equivalent) for DF1 protocol communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52476507488565,"sku":"1761-L32AAA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-L32AAA.jpg?v=1774411352"},{"product_id":"1761-cbl-am00-allen-bradley-micrologix-to-aic-rs-232-communication-cable","title":"1761-CBL-AM00 | Allen Bradley MicroLogix to AIC+ RS-232 Communication Cable","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1761-CBL-AM00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized RS-232 serial interconnect designed for the MicroLogix controller ecosystem. This 0.5-meter (18-inch) cable facilitates high-speed data exchange between a MicroLogix processor and an 1761-NET-AIC (AIC+) Advanced Interface Converter. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring low-impedance signal transmission for mission-critical programming, online monitoring, and peer-to-peer messaging in DF1 Full-Duplex environments.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cp\u003eThe 1761-CBL-AM00 maintains industrial-grade signal integrity with the following physical and electrical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS-232 Serial Communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector A:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8-pin mini-DIN (Male)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector B:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8-pin mini-DIN (Male)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Length:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 Meters (18 Inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDF1 Full-Duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMicroLogix 1000, 1200, 1500; AIC+ (1761-NET-AIC) modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade shielded PVC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFoil and Braid for EMI\/RFI protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielded Signal Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable utilizes high-density shielding to suppress electromagnetic interference (EMI) from nearby high-voltage motor leads and VFDs. This protection ensures error-free data packets during sensitive PLC programming and online monitoring sessions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision 8-Pin Mini-DIN Coupling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSpecifically engineered 8-pin connectors provide a secure, vibration-resistant fit into the MicroLogix and AIC+ communication ports. This mechanical stability prevents accidental data dropouts caused by cabinet vibrations or cable movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Short-Link Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 0.5-meter length eliminates excessive cable slack within control enclosures. This \"short-run\" design reduces signal attenuation and simplifies cable management in high-density DIN-rail layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Controller Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable interfaces seamlessly across the MicroLogix 1000, 1200, and 1500 platforms. This allows maintenance teams to standardize their communication hardware across multiple machine generations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDF1 Protocol Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy supporting the DF1 Full-Duplex protocol, the 1761-CBL-AM00 enables simultaneous two-way communication. This increases the responsiveness of HMI updates and accelerates the upload\/download speeds of ladder logic projects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1761-CBL-AM00 to connect a MicroLogix directly to a PC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This cable features 8-pin mini-DIN connectors on both ends. To connect a MicroLogix to a standard PC DB9 serial port, you must use the 1761-CBL-PM02 cable. The 1761-CBL-AM00 specifically links the controller to an AIC+ module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this cable provide power to the AIC+ module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When connected to a MicroLogix controller that provides power on its communication port, the 1761-CBL-AM00 carries the necessary 24V DC to power the 1761-NET-AIC module, eliminating the need for an external power supply in many configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Allen Bradley factory-sealed product?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We guarantee this 1761-CBL-AM00 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware. It arrives in the original manufacturer’s packaging with all verifiable part numbers and security seals intact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this and the 1761-CBL-HM02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1761-CBL-AM00 is a short (0.5m) cable primarily used for side-by-side mounting of an AIC+ and a PLC. The HM02 is a longer (2m) version of the same cable used for more distant chassis connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52477546168629,"sku":"1761-CBL-AM00","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-CBL-AM00.jpg?v=1774421028"},{"product_id":"micrologix-1000-allen-bradley-1761-l16bwb-programmable-logic-controller","title":"MicroLogix 1000 | Allen-Bradley 1761-L16BWB Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1761-L16BWB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a self-contained, micro-scale controller within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix 1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. This compact PLC manages discrete automation tasks by integrating 10 DC inputs and 6 relay outputs into a single high-density footprint. Although the manufacturer classifies this series as discontinued, we supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock. It provides a drop-in solution for maintaining existing machine-level control systems without the high engineering costs associated with hardware migration or control program rewrites.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Points Total\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTen (10) 24V DC (Sinking or Sourcing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSix (6) Relay Contact Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4–26.4V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 K EEPROM (737 instruction words)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 (DF1 Protocol)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInrush Current\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30A for 4 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eVibration\/Shock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 G (Operating) \/ 20 G (Non-Operating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.50 lbs (0.23 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Input Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1761-L16BWB accepts both sinking and sourcing input configurations. This allows engineers to interface with a wide range of NPN or PNP sensors without adding external pull-up or pull-down resistors, simplifying field wiring in mixed-device environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Relay Output Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix integrated relay outputs handle various load types, including AC and DC voltages. These dry contacts eliminate the need for interposing relays when switching small solenoid valves or motor starters, reducing total cabinet space and material costs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Logic Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1K EEPROM stores the entire user program and data. This memory technology eliminates the need for backup batteries, ensuring the PLC retains its logic indefinitely during long-term power outages or equipment storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardened Industrial Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand 10 G of operating shock, the 1761-L16BWB excels in high-vibration applications such as sorting conveyors, packaging machines, and mobile industrial platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Logic Execution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe dedicated 1761 processor executes instructions with high repeatability. It processes approximately 737 instruction words with consistent scan times, ensuring precise timing for high-speed discrete manufacturing sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software do I need to program the 1761-L16BWB?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou must use RSLogix 500 or RSLogix Micro software. The controller communicates via the 8-pin mini-DIN RS-232 port using the DF1 protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace a 1761-L16BWA with a 1761-L16BWB?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck your power source first. The \"BWA\" model requires 120\/240V AC power, whereas the \"BWB\" model requires a 24V DC power supply. While the I\/O count remains the same, the power wiring differs significantly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support I\/O expansion modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The MicroLogix 1000 series features a fixed I\/O configuration. If your application requires more than 16 points, you should consider the MicroLogix 1100 or 1200 series, which support 1762 expansion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know this unit is truly brand new?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee every 1761-L16BWB arrives in its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOriginal Allen-Bradley Factory Packaging\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith intact serial numbers and seals. This ensures the 50,000-cycle minimum power cycle rating remains fully available for your application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52532272693557,"sku":"1761-L16BWB","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-L16BWB.jpg?v=1775205219"},{"product_id":"allen-bradley-1764-rtc-micrologix-1500-real-time-clock-module","title":"Allen Bradley 1764-RTC MicroLogix 1500 Real-Time Clock Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1764-RTC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential time-keeping and scheduling capabilities for the MicroLogix™ 1500 controller platform. This module snaps directly into the processor to enable precise time-stamping of fault logs, event scheduling, and time-of-day control logic. While the manufacturer has officially moved this series to obsolete status, we supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new and original\u003c\/strong\u003e, allowing you to maintain legacy systems with authentic, high-precision timing hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1764-RTC maintains strict timing accuracy across industrial temperature ranges:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-Time Clock (RTC) Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1500 Processors (1764-LRP, 1764-LSP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRTC Accuracy (+25°C)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+36 to -68 seconds\/month\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBattery Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in, Non-replaceable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBattery Life Expectancy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 years @ 0°C to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBattery Low Status Bit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRTC:0\/BL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHot Swapping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Removal and Insertion Under Power (RIUP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 lbs (0.45 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Temporal Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1764-RTC allows the MicroLogix 1500 to execute time-of-day logic for building automation, lighting control, and shift-based production scheduling. It ensures the controller maintains an accurate calendar even during extended power outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes a dedicated status bit (RTC:0\/BL) within the controller's memory. This feature allows the user program to trigger local alarms or HMI messages when the internal battery reaches a low-voltage state, preventing unexpected loss of time data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eZero-Downtime Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports \"Removal and Insertion Under Power\" (RIUP). Engineers replace or install the module while the system remains energized, eliminating the need to cycle power to the entire control chassis during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Plug-in Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware seats firmly into the processor's dedicated expansion port. This internal mounting style protects the module from external EMI and mechanical vibration while preserving valuable DIN rail space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Data Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal battery provides a minimum 5-year operating life under standard conditions. This high-capacity cell ensures the clock continues to track minutes, hours, and years accurately during warehouse storage or long-term system shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the internal battery of the 1764-RTC be replaced?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1764-RTC features a non-replaceable built-in battery designed for a 5-year lifespan. When the \"Battery Low\" bit (RTC:0\/BL) activates, you must replace the entire module to ensure continued time-keeping reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine, brand-new unit since the series is discontinued?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. We guarantee that every 1764-RTC we ship is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand arrives in original factory packaging. We specialize in providing authentic, factory-sealed legacy hardware to ensure E-E-A-T procurement standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1764-RTC provide additional user memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1764-RTC only provides real-time clock functionality. If your application requires additional program storage, you must utilize a memory module such as the 1764-MM1 or 1764-MM2.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set the time on the 1764-RTC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou configure and synchronize the clock through the \"Channel Configuration\" or \"Function Files\" menu in RSLogix 500 software. You can also use a \"Set Real-Time Clock\" (RTC) instruction within the ladder logic to adjust the time programmatically.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52562881675573,"sku":"1764-RTC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-RTC.jpg?v=1776071027"},{"product_id":"allen-bradley-1762-mm1-micrologix-1200-non-volatile-memory-module","title":"Allen Bradley 1762-MM1 MicroLogix 1200 Non-Volatile Memory Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1762-MM1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized non-volatile storage solution for the MicroLogix 1200 controller series. This plug-in module provides 8K words of memory to secure user programs and configuration data against power loss or hardware failure. It functions as a portable repository, allowing for rapid program duplication and deployment across multiple controllers. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical logic backups reside on factory-fresh, high-integrity silicon.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1762-MM1 utilizes compact, reliable storage architecture for industrial environments:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1200\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8K Words\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-Volatile Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Plug-in Slot\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgram Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle Program Image\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eData Retention\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndefinite (Power Loss Safe)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRSLogix 500 \/ Controller Set-up\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.06 lbs (0.03 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRUN LED Flash (During access)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe 1762-MM1 solves several operational risks and maintenance bottlenecks in the automation lifecycle:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElimination of Battery Dependency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy migrating the user program from volatile RAM to the 1762-MM1 non-volatile flash, the system eliminates the risk of program loss during extended power outages or battery depletion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Machine Replication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOEM builders use the 1762-MM1 for \"Master Program\" transport. An engineer saves the tested logic to one module and simply plugs it into subsequent MicroLogix 1200 units on the production line, ensuring 100% code consistency across the fleet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Field Replacement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn the event of a controller failure, onsite personnel simply move the 1762-MM1 from the old unit to the new one. The controller automatically detects the module and loads the application, restoring the machine to service without a laptop or software expert.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure Data Archiving:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports \"Store to Module\" and \"Load from Module\" operations protected by controller passwords, ensuring that proprietary machine logic remains secure during transport or storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1762-MM1 store the data log and recipe files as well?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1762-MM1 primarily stores the ladder logic program and configuration settings. While it secures the base application, you must configure specific data file protection in RSLogix 500 to ensure retentive data values transfer correctly during a module load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the 1762-MM1 with MicroLogix 1100 or 1500 controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1762-MM1 specifically fits the 1762 expansion slot architecture of the MicroLogix 1200. MicroLogix 1100 controllers utilize embedded flash, and MicroLogix 1500 units require 1764-series memory modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the controller is actually using the memory module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can configure the controller via software to \"Load from Memory Module on Power-up.\" Additionally, the controller’s RUN LED flashes during the initial data transfer from the 1762-MM1, confirming a successful boot from the non-volatile source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should I take during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlways remove power from the MicroLogix 1200 before inserting the 1762-MM1. Static discharge can damage the module, so use a grounding strap or touch a grounded metal surface before handling the unit to ensure long-term reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52767139135797,"sku":"1762-MM1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-MM1.jpg?v=1776736253"},{"product_id":"1761-l16awa-allen-bradley-micrologix-1000-programmable-logic-controller","title":"1761-L16AWA Allen-Bradley | MicroLogix 1000 Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1761-L16AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a compact, standalone controller within the established MicroLogix 1000 family. It provides a cost-effective solution for small-scale automation tasks requiring high-voltage AC inputs and flexible relay outputs. While the manufacturer classifies this series as discontinued, we supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original factory-sealed units\u003c\/strong\u003e. This ensures your facility maintains legacy hardware without the risks associated with used or refurbished components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120V AC (10 Sinking Inputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Relay (Contact) Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V AC (Auto-sensing 47-63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1K EEPROM (Approx. 737 Instruction Words)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232 Port (DF1 Protocol)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.24 x 2.87 x 3.15 inches\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10G Operating \/ 20G Non-operating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1761-L16AWA eliminates the need for separate DC power supplies by accepting 120\/240V AC line voltage directly. This simplifies panel wiring and reduces the overall footprint in compact control enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Signal Directness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 120V AC input circuitry allows the PLC to interface directly with industrial pushbuttons and limit switches without intermediate interposing relays. This reduces potential points of failure and lowers installation labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEEPROM Data Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal 1K EEPROM stores your ladder logic and data permanently without requiring a battery. This feature eliminates maintenance schedules for battery replacement and protects your program during long-term power outages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Vibration Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a 10G operating shock rating, this controller thrives in high-vibration environments such as material handling conveyors and packaging machinery where lesser controllers suffer from mechanical fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I program the 1761-L16AWA if the software is legacy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou can utilize RSLogix 500 software to configure and program this unit. It connects via the integrated RS-232 port using a standard 1761-CBL-PM02 cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a \"New Surplus\" unit or a modern reproduction?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, original Allen-Bradley unit\u003c\/strong\u003e. We source these from authentic stock to ensure the hardware meets the original factory electrical specifications and safety certifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support Peer-to-Peer messaging?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Through the DF1 protocol and the RS-232 port, the 1761-L16AWA communicates with other MicroLogix or SLC 500 controllers, allowing for basic data sharing across your local network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary mounting restrictions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit supports both DIN rail and panel mounting. To ensure proper thermal dissipation, maintain at least 2 inches (50.8 mm) of clearance on all sides, especially when operating at the upper limit of its 7-watt power consumption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52774182256949,"sku":"1761-L16AWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1761-L16AWA.jpg?v=1776822914"},{"product_id":"allen-bradley-1764-28bxb1-micrologix-1500-28-point-base-module","title":"Allen-Bradley 1764-28BXB1 MicroLogix 1500 28-Point Base Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1764-28BXB1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-density hardware foundation for the MicroLogix 1500 controller system. This base module provides the essential physical interface for 28 I\/O points, integrating power distribution and I\/O termination into a single unit. It accommodates a 1764-LSP or 1764-LRP processor to form a complete functional PLC. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your legacy systems maintain maximum uptime with factory-fresh circuitry, even though the manufacturer has officially discontinued this series.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal I\/O Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28 Points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 DC Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–30V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTotal Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRelay Output Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTransistor Output Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 FET (Field Effect Transistor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.98 lbs (0.90 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed Screw Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Output Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1764-28BXB1 features a \"BXB\" configuration, providing 6 Relay outputs for high-current switching and 6 FET outputs for high-speed pulse applications. This hybrid design allows a single controller to manage both heavy-duty solenoid valves and high-frequency motion signals simultaneously.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Processing Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe separate base and processor design allows for rapid maintenance. If a processor fails or requires an upgrade, you swap the logic module without disturbing the field wiring connected to the 1764-28BXB1 base, significantly reducing MTTR (Mean Time To Repair).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust DC Input Stage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 DC inputs operate across a wide 10–30V DC range. This tolerance accommodates voltage fluctuations in unconditioned power environments and ensures reliable signal detection for standard 12V and 24V industrial sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe base chassis utilizes optimized ventilation slots to dissipate heat generated by the FET outputs and internal power conversion. This design maintains stable operation in compact enclosures where airflow remains limited.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this base module include the processor?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 1764-28BXB1 is the base module only. You must install a MicroLogix 1500 processor (1764-LSP or 1764-LRP) into the top slot of this base to execute logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a refurbished or used unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely not. We guarantee this 1764-28BXB1 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e. It arrives in its original factory packaging with untouched screw terminals, ensuring the full mechanical and electrical life of the relay contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this base to replace a 1764-24BWA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1764-28BXB1 uses DC power and features a different I\/O count and output type compared to the AC-powered 1764-24BWA. You must verify your wiring diagrams and power supply voltage (24V DC vs 120V AC) before attempting a replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of the FET outputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 6 FET transistor outputs support high-speed switching that mechanical relays cannot achieve. Use these outputs for Pulse Width Modulation (PWM) or for controlling sensitive electronic devices that require arc-free operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52774578782517,"sku":"1764-28BXB1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-28BXB1.jpg?v=1776836382"},{"product_id":"allen-bradley-1764-mm2rtc-micrologix-1500-memory-module-with-real-time-clock","title":"Allen-Bradley 1764-MM2RTC MicroLogix 1500 Memory Module with Real-Time Clock","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1764-MM2RTC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides critical data redundancy and time-stamping capabilities for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix 1500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller platform. This dual-function expansion module integrates 16 KB of non-volatile memory for program backup alongside a high-precision Real-Time Clock (RTC). It ensures the controller retains vital ladder logic and register data during power cycles while enabling time-scheduled automation events. Although the manufacturer has discontinued this series, we supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal hardware, allowing you to maintain existing MicroLogix installations without upgrading the entire control architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1764-MM2RTC combines memory storage and chronological tracking in a compact form factor:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1500\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-volatile Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eClock Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-Time Clock (RTC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicroLogix 1500 Base Units (1764)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.04 lbs (0.018 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLifecycle Status\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDiscontinued by Manufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Program Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 KB flash memory stores a complete backup of the user program and data table. This prevents catastrophic data loss if the controller's internal battery fails, allowing for immediate automatic recovery upon power-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Time-Stamping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe integrated Real-Time Clock enables the PLC to execute time-of-day, day-of-week, or calendar-based control logic. This functionality proves essential for data logging applications where every event requires an accurate temporal marker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEliminates Manual Program Loading:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBy setting the controller to \"Load on Power-up,\" the 1764-MM2RTC automatically transfers the stored program to the processor's RAM. This feature minimizes downtime in remote locations where a technician with a laptop may not be immediately available.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Plug-in Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module seats directly into the specialized memory port on the front of the MicroLogix 1500 processor. Its low-profile architecture ensures it does not interfere with the controller's wiring or physical footprint within the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBumpless Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module allows for easy \"cloning\" of PLC programs. You can program one module and physically move it to another MicroLogix 1500 unit to replicate control parameters quickly across multiple machines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Down:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways remove power from the MicroLogix 1500 base unit before inserting or removing the 1764-MM2RTC to prevent electrical transients from damaging the flash memory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemove the protective cover from the memory module port on the processor. Align the module pins carefully with the port and press firmly until it seats flush.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse RSLogix 500 software to configure the \"Memory Module\" settings in the Controller Properties. You must define whether the processor should load from the module on every power cycle or only upon memory error.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClock Sync:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse the \"Set Date and Time\" function in the programming software to synchronize the RTC with your local time zone after the initial installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the 1764-MM2RTC in a MicroLogix 1100 or 1200 controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 1764-MM2RTC specifically fits the 1764-series processor used in the MicroLogix 1500 system. Other MicroLogix models utilize different memory module form factors (such as the 1762 or 1763 series).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require a battery to maintain the 16 KB memory?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The 16 KB memory uses non-volatile flash technology, which retains data indefinitely without power. However, the Real-Time Clock function relies on the controller's internal battery to keep time while the system is powered off.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 1764-MM1 and the 1764-MM2RTC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1764-MM1 provides memory backup only. The 1764-MM2RTC adds the Real-Time Clock feature, which is necessary if your ladder logic includes RTC-based instructions like \"Read Clock\" or \"Write Clock.\"\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to write-protect the program on the memory module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. You can configure write-protection via the RSLogix 500 software settings to prevent unauthorized or accidental overwriting of the backup program stored on the 1764-MM2RTC.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52800901218613,"sku":"1764-MM2RTC","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-MM2RTC.png?v=1777450284"},{"product_id":"1764-mm2-allen-bradley-micrologix-1500-16kb-memory-module-with-rtc","title":"1764-MM2 | Allen Bradley | MicroLogix 1500 16KB Memory Module with RTC","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen Bradley 1764-MM2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides critical non-volatile memory expansion and time-stamping capabilities for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroLogix 1500\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller platform. This module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 KB of EEPROM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ememory, specifically designed to back up user programs and data logs, ensuring zero data loss during prolonged power outages. Additionally, it integrates a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-Time Clock (RTC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support time-scheduled control logic and event logging. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal factory stock to guarantee the highest data integrity and physical lifespan for your control system.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen Bradley \/ Rockwell Automation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Size\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 KB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEEPROM (Non-volatile)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated \/ Available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Draw\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e350 mA @ 5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWrite Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware-supported Write Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShock \/ Vibration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 G \/ 2.5 G\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 °C (32 to 131 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePermanent Data Retention:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1764-MM2 utilizes high-grade\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEEPROM technology\u003c\/strong\u003e. This ensures the controller retains your user program and register data indefinitely without requiring battery power, solving the problem of memory loss during long-term machinery shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Time Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe built-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-Time Clock (RTC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the MicroLogix 1500 to execute time-of-day automation and precise fault logging. This hardware eliminates the drift common in software-based timers, providing accurate timestamps for industrial audits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Security via Write Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module includes dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWrite Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctionality. This prevents unauthorized or accidental overwriting of the backup program, ensuring that the machine always reboots to a verified, safe state after a system reset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRuggedized Industrial Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWith a shock resistance rating of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30 G\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand vibration tolerance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.5 G\u003c\/strong\u003e, the 1764-MM2 thrives in high-vibration environments like stamping presses or mobile equipment. The compact design snaps directly into the processor base, maintaining a secure electrical connection even under mechanical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1764-MM2 require a battery for the memory to function?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The memory uses EEPROM technology, which stores data without a power source. However, the Real-Time Clock (RTC) feature utilizes the processor's internal power management to maintain time during power-down cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I swap memory modules while the MicroLogix 1500 is powered on?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. You must remove power from the controller before installing or removing the 1764-MM2. Inserting the module while energized risks corrupting the EEPROM data or damaging the communication pins on the processor base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the 1764-MM1 and the 1764-MM2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 1764-MM2 provides twice the memory capacity (\u003cstrong\u003e16 KB\u003c\/strong\u003e) compared to the 1764-MM1 (\u003cstrong\u003e8 KB\u003c\/strong\u003e) and includes the integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-Time Clock\u003c\/strong\u003e. If your logic requires time-stamping or large data arrays, the 1764-MM2 is the mandatory upgrade.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a \"New Surplus\" or \"Refurbished\" item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNeither. We guarantee this product is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the original manufacturer’s packaging. It carries the original UPC\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e611320238037\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand has never been previously installed or energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52804989616437,"sku":"1764-MM2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1764-MM2.png?v=1777537484"},{"product_id":"1762-l40awa-allen-bradley-micrologix-1200-programmable-logic-controller","title":"1762-L40AWA | Allen-Bradley | MicroLogix 1200 Programmable Logic Controller","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1762-L40AWA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-density, self-contained controller within the MicroLogix 1200 family. It provides 40 built-in I\/O points, making it a cornerstone for medium-scale industrial automation tasks where panel space remains a premium. This unit manages complex machine logic by utilizing 24 digital inputs and 16 robust relay outputs. We offer this product as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and factory-original\u003c\/strong\u003e, ensuring your control architecture benefits from the full lifespan of genuine hardware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe 1762-L40AWA optimizes performance through the following electrical and physical parameters:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 Digital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 Relay Contact Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120\/240V AC (Operating range 47-63 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Supply Output\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 mA at 5V DC \/ 500 mA at 24V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHeat Dissipation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 Watts\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Off-State Leakage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Torque\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.791 Nm (7.0 lb-in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.00 lbs (0.91 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density I\/O Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 1762-L40AWA packs 40 I\/O points into a compact chassis. This configuration reduces the need for additional expansion modules, effectively lowering hardware costs and decreasing the overall footprint in crowded control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Power Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal power supply accommodates both 120V and 240V AC nominal inputs. This flexibility allows global deployment of machinery without requiring separate transformers or different regional SKU management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Power for Peripherals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis controller provides dedicated 5V and 24V DC outputs. These power rails support expansion I\/O modules and external sensors directly from the PLC, simplifying field wiring and reducing the component count.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelay Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 16 relay contact outputs handle a mix of AC and DC loads. This feature allows the 1762-L40AWA to control various field devices such as solenoids, motor starters, and pilot lights without the need for interposing relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 1762-L40AWA require a separate battery for memory backup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe MicroLogix 1200 uses flash memory for program storage. While the unit maintains the program without power, we recommend using the optional 1747-BA battery if your application requires long-term retention of volatile data values during extended power-down periods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I expand the I\/O beyond the 40 built-in points?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can expand the controller’s capability by adding 1762 series expansion I\/O modules to the right side of the base unit. The 1762-L40AWA supports up to six expansion modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the correct way to handle high inrush current during startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis unit draws up to 40 Amps of inrush current at 240V AC. Ensure your upstream circuit breakers and power distribution components account for this short-duration spike (4-8 ms) to prevent nuisance tripping during system initialization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre these units refurbished or new-old-stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee every 1762-L40AWA unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. These are original Allen-Bradley products in their factory packaging, ensuring the relay contacts and internal capacitors have zero prior operational wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52846708982069,"sku":"1762-L40AWA","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1762-L40AWA.png?v=1778205702"}],"url":"https:\/\/www.5gplc.com\/collections\/allen-bradley-micrologix.oembed?page=2","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}