{"title":"ABB Bailey Infi 90 \u0026 Net 90","description":"\u003cp\u003e\u003cspan\u003e\u003c\/span\u003e\u003cstrong\u003eABB Bailey Infi 90 \u0026amp; Net 90\u003c\/strong\u003e\u003cspan\u003e are advanced \u003c\/span\u003e\u003cstrong\u003edistributed control systems (DCS)\u003c\/strong\u003e\u003cspan\u003e designed for process automation in industries such as chemical, energy, and manufacturing. These platforms integrate PLCs, I\/O modules, and field devices to deliver \u003c\/span\u003e\u003cstrong\u003ereal-time process monitoring, centralized control, and high system availability\u003c\/strong\u003e\u003cspan\u003e. They provide modular, scalable architectures with robust communication networks, ensuring maintainable and reliable automation solutions for complex industrial operations.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"abb-imblk01-infi-90-durable-blank-module-assembly","title":"ABB IMBLK01 Infi 90 Durable Blank Module Assembly","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe ABB\u003cstrong\u003e IMBLK01\u003c\/strong\u003e Infi 90 Blank Module Assembly is a durable unit engineered to provide secure slot coverage and reliable integration within ABB control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOrigin:\u003c\/strong\u003e Sweden\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e IMBLK01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Blank Module Assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 48.26 mm*187.96 mm*76.2 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 1.1 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePackaging Unit:\u003c\/strong\u003e 1 piece\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Slot coverage and structural integration in ABB Infi 90 control frameworks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Provides long-lasting coverage for unused module slots\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCompact Build:\u003c\/strong\u003e Optimized size for seamless installation into ABB control units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReliable Integration:\u003c\/strong\u003e Ensures secure fit within ABB Infi 90 systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProtective Function:\u003c\/strong\u003e Safeguards internal components from dust and mechanical stress\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLow Maintenance:\u003c\/strong\u003e Long service life with minimal upkeep requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52049902731573,"sku":"IMBLK01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMBLK01.jpg?v=1765433635"},{"product_id":"abb-ntdi01-symphony-plus-digital-input-termination-unit","title":"ABB NTDI01 Symphony Plus Digital Input Termination Unit","description":"\u003ch3 class=\"\" data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTDI01\u003c\/strong\u003e serves as a dedicated digital input termination assembly for the Symphony Plus and Harmony rack-based control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It functions as the primary physical bridge between discrete field devices and the system's I\/O processing modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit is designed to organize high-density field wiring,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing a secure and electrically stable environment for critical signal transmission in large-scale distributed control system (DCS) architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\" data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,0,0\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,1,0\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTDI01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,2,0\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,3,0\"\u003eSignal Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Discrete Digital Input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,4,0\"\u003eCapacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,5,0\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard DIN Rail or Cabinet Baseplate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,6,0\"\u003eTermination Style\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compression-style screw terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,7,0\"\u003ePhysical Weight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e45 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,8,0\"\u003eInterface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-pin cable connector for I\/O module linking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"5,9,0\"\u003eEnvironmental Rating\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard industrial cabinet deployment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\" data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"7,0,0\"\u003eSimplified Field Connectivity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Offers organized terminal blocks that facilitate clean cable management and reduce the risk of wiring errors during commissioning.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"7,1,0\"\u003ePassive Design Integrity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered with high-quality passive components to ensure long-term reliability and minimal maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb class=\"\" data-index-in-node=\"0\" data-path-to-node=\"7,2,0\"\u003eEfficient Troubleshooting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features distinct labeling and accessible test points,\u003c\/span\u003e\u003cspan\u003e allowing technicians to verify field signals without disconnecting the system logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,3,0\"\u003eUniversal Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed to interface with a variety of digital input modules within the ABB Harmony and Symphony Plus families.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,4,0\"\u003eRuggedized Terminals\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to maintain gas-tight connections in industrial environments prone to vibration and thermal cycling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-index-in-node=\"0\" data-path-to-node=\"7,5,0\"\u003eSpace-Saving Footprint\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Compact design allows for high-density mounting within standard control enclosures,\u003c\/span\u003e\u003cspan\u003e maximizing available cabinet space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095465357621,"sku":"NTDI01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTDI01.jpg?v=1766634747"},{"product_id":"abb-bailey-ntr002-a-temperature-sensor-rtd-interface-module","title":"ABB Bailey NTR002-A Temperature Sensor RTD Interface Module","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB \u003cstrong\u003eNTR002-A\u003c\/strong\u003e is a dedicated temperature sensor interface engineered for the Bailey INFI 90 and Symphony Plus control platforms. It acts as a high-precision bridge between field-mounted Resistance Temperature Detectors (RTDs) and the system's input processing logic. This module is essential for converting low-level resistance signals into accurate digital data, ensuring reliable thermal monitoring for boilers, turbines, and chemical reactors. By providing specialized signal conditioning and noise rejection, the NTR002-A maintains tight process control in demanding industrial environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: NTR002-A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eInput Compatibility\u003c\/b\u003e: Supports 2-wire, 3-wire, and 4-wire RTD configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eSupported Sensors\u003c\/b\u003e: Platinum (Pt100), Copper (Cu10), and Nickel (Ni120) types\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eSignal Conditioning\u003c\/b\u003e: Integrated linearization and resistance compensation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Standard Bailey modular rack assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e: 0.52 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003ePower Requirements\u003c\/b\u003e: Low-power consumption via system backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eIsolation\u003c\/b\u003e: Optical and galvanic isolation between field and logic circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003ePrecision Linearization\u003c\/b\u003e: Automatically corrects sensor-specific non-linearity to deliver high-accuracy temperature data across a broad measurement spectrum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eLead Wire Compensation\u003c\/b\u003e: Utilizes 3-wire and 4-wire techniques to eliminate measurement errors caused by long-distance field cabling resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eFault Detection Capabilities\u003c\/b\u003e: Includes built-in diagnostics to identify sensor failures, open circuits, or shorted leads, alerting the control system immediately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIndustrial Noise Immunity\u003c\/b\u003e: Optimized filtering circuitry prevents electromagnetic interference (EMI) from corrupting sensitive thermal signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eDynamic Range Support\u003c\/b\u003e: Capable of handling a wide variety of temperature ranges through software-configurable gain and offset parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eDurable Construction\u003c\/b\u003e: Designed with industrial-grade components to ensure a long operational lifespan within harsh control cabinet environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095472369973,"sku":"NTR002-A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTR002-A.jpg?v=1766635106"},{"product_id":"abb-bailey-imfec12-symphony-plus-analog-input-slave-module","title":"ABB Bailey IMFEC12 Symphony Plus Analog Input Slave Module","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB\u003cstrong\u003e IMFEC12\u003c\/strong\u003e is a high-performance analog input slave module designed for the Bailey INFI 90 and Symphony Plus distributed control systems. It functions as a precision interface for collecting continuous field data from transmitters, sensors, and other linear devices. This module is capable of processing multiple standard signal types, including 4-20 mA current loops and various voltage ranges, converting them into digital values for the system's controller modules. Built for mission-critical process automation, the IMFEC12 ensures high data throughput and signal fidelity in complex industrial environments such as power plants and chemical processing facilities.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: IMFEC12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eInput Type\u003c\/b\u003e: Analog Input (Slave Module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eChannel Density\u003c\/b\u003e: 15 independent channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eInput Signal Range\u003c\/b\u003e: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC, or 4 to 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eAnalog to Digital Resolution\u003c\/b\u003e: 12-bit binary conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003ePower Requirements\u003c\/b\u003e: +5 VDC and +\/-15 VDC provided via cabinet backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003eMounting Configuration\u003c\/b\u003e: Single slot occupancy in standard Module Mounting Unit (MMU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eNet Weight\u003c\/b\u003e: 0.55 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e: 0 to 70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eMulti-Channel Processing\u003c\/b\u003e: Efficiently handles up to 15 analog signals, providing a high-density solution for large-scale I\/O requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eVersatile Signal Compatibility\u003c\/b\u003e: Offers the flexibility to interface with various industrial standard input ranges through hardware jumpers or software settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eIntelligent Data Scaling\u003c\/b\u003e: Includes on-board processing to perform signal validation, engineering unit conversion, and digital filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eSystem Bus Isolation\u003c\/b\u003e: Features robust electrical isolation to protect sensitive internal logic from field-side transients and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eReal-Time Self-Diagnostics\u003c\/b\u003e: Continuously monitors hardware integrity and signal status, reporting errors or out-of-range conditions to the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSynchronized Data Transfer\u003c\/b\u003e: Optimized for high-speed communication across the Slave Expander Bus, ensuring low-latency updates for critical control loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095474368821,"sku":"IMFEC12","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMFEC12.jpg?v=1766635394"},{"product_id":"abb-bailey-imdso14-digital-slave-output-module-16-channel","title":"ABB Bailey IMDSO14 Digital Slave Output Module 16-Channel","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMDSO14 \u003c\/strong\u003eis a high-reliability digital slave output module designed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It acts as a command interface that translates digital logic signals from a master controller into discrete outputs used to drive field equipment.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is typically deployed to manage the switching states of relays,\u003c\/span\u003e\u003cspan class=\"\"\u003e motor starters,\u003c\/span\u003e\u003cspan class=\"\"\u003e solenoid valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e and indicator lamps.\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered for precision and longevity,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMDSO14 ensures deterministic control execution within complex industrial automation frameworks,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it a staple in power generation and heavy manufacturing environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMDSO14\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Digital Slave Output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Quantity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Independent Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eLogic Voltage\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (from backplane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Rating\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Designed for use with external termination units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e48 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Density Control\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provides 16 discrete output channels in a compact modular form factor,\u003c\/span\u003e\u003cspan class=\"\"\u003e maximizing I\/O capacity per rack.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eSlave Bus Integration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Communicates seamlessly with Harmony Area Controllers via the Expander Bus for high-speed logic synchronization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eOn-Board Intelligence\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Utilizes an internal microprocessor to monitor module health and verify the integrity of output commands.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eOptical Isolation\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features built-in electrical isolation to safeguard the system’s sensitive internal bus from field-side electrical noise and transients.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eFail-Safe States\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Supports configurable default output states (on,\u003c\/span\u003e\u003cspan\u003e off,\u003c\/span\u003e\u003cspan\u003e or hold) in the event of a communication loss with the master controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eAdvanced Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously performs self-testing and reports status via front-panel LED indicators,\u003c\/span\u003e\u003cspan\u003e facilitating rapid fault identification and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095662850357,"sku":"IMDSO14","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMDSO14.jpg?v=1766646811"},{"product_id":"abb-bailey-ntmp01-multi-function-processor-termination-unit","title":"ABB Bailey NTMP01 Multi-Function Processor Termination Unit","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB \u003cstrong\u003eNTMP01\u003c\/strong\u003e is a dedicated interface assembly designed for Bailey INFI 90 Multi-Function Processors (MFP). It provides the essential physical connection points for system communication and redundant processor linking. Engineered for reliability in Symphony Plus architectures, this unit simplifies field wiring and ensures stable data transmission for high-demand industrial automation controllers.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: NTMP01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eComponent Type\u003c\/b\u003e: MFP Termination Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Standard N-type Termination Base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eInterface\u003c\/b\u003e: Multi-pin headers for processor and redundant links\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e: 0 to 70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e: 0.38 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eProcessor Support\u003c\/b\u003e: Connects IMMFP series processors to the system expander bus and I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eRedundancy Management\u003c\/b\u003e: Features dedicated ports to support high-availability redundant processor pairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSimplified Service\u003c\/b\u003e: Enables module replacement without disconnecting permanent system cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003ePassive Integrity\u003c\/b\u003e: Built with high-quality passive circuitry for long-term maintenance-free operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eIndustrial Hardening\u003c\/b\u003e: Designed for high-EMC environments typical of power and process facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eEfficient Footprint\u003c\/b\u003e: Optimized layout for high-density cabinet mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095704105269,"sku":"NTMP01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTMP01__1.jpg?v=1766647056"},{"product_id":"abb-bailey-innis01-network-interface-slave-module","title":"ABB Bailey INNIS01 Network Interface Slave Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eINNIS01 \u003c\/strong\u003eis a critical communication bridge designed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It functions as the interface between the high-speed Cnet (Control Network) and the local module bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e enabling seamless data exchange between the network and individual functional modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e This slave module works in conjunction with a Network Interface Master (INCPM) to coordinate reliable real-time messaging across the DCS architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring high-speed process control synchronization and system-wide data transparency in utility and industrial power environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INNIS01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Interface Slave (Cnet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eData Transfer Rate\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed synchronous communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC via the system backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eBus Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Expander Bus and Cnet link\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Occupies one slot in a standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eStatus Monitoring\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Front-panel LED indicators for operational health\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e54 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Integration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Acts as the primary gateway for data traffic between the Plant Loop\/Cnet and the local processing rack.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDual-Bus Communication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Manages concurrent data flow across both the Controlway and the Slave Expander Bus for maximum efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eIntelligent Buffer Management\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features on-board memory to buffer incoming and outgoing packets,\u003c\/span\u003e\u003cspan\u003e preventing data loss during peak network loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eHardware Self-Testing\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously executes internal diagnostic routines to verify the integrity of the communication hardware and local bus links.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eSeamless Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Engineered to integrate with both legacy INFI 90 hardware and modern Symphony Plus system upgrades.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eHot-Swap Support\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for replacement in a live system environment when paired with redundant masters to maintain network availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095704531253,"sku":"INNIS01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INNIS01_f8ce409a-415a-4110-9114-d6946c2998f2.jpg?v=1766647598"},{"product_id":"abb-bailey-ntcl01-infi-net-communication-link-termination-unit","title":"ABB Bailey NTCL01 INFI-Net Communication Link Termination Unit","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTCL01\u003c\/strong\u003e is a specialized termination unit designed to facilitate the physical connection of the INFI-Net communication link within the Bailey INFI 90 and Symphony Plus architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e It serves as the bridge between the network interface modules and the twin-axial or coaxial plant loop cables.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit is essential for maintaining high-speed data backbone integrity,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing a secure and organized termination point that supports the high-availability requirements of large-scale distributed control systems (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e Its robust design ensures reliable data throughput across complex industrial networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTCL01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eSystem Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI-Net \/ Plant Loop\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Unit Mounting Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eCable Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Support for twin-axial or coaxial networking cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eConnection Ports\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-pin headers for interface module cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e42 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eEnvironmental Protection\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Industrial-grade PCB coating for corrosion resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Backbone Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provides the critical physical interface for the primary INFI-Net communication ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundant Link Capability\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features dedicated connection paths to support dual-redundant network configurations for maximum system uptime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eOptimized Signal Path\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered with high-quality termination resistors and shielded paths to minimize signal reflection and electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eModular Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for quick installation into standard Bailey termination bases,\u003c\/span\u003e\u003cspan\u003e allowing for efficient cabinet layout.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003ePassive Circuitry\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Employs a passive hardware design to ensure long-term reliability without additional power consumption.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eEasy Maintenance\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Facilitates network testing and cable inspections without the need to disturb the associated interface modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095706169653,"sku":"NTCL01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTCL01.jpg?v=1766647809"},{"product_id":"abb-bailey-ntai06-analog-input-termination-unit-for-harmony-infi-90","title":"ABB Bailey NTAI06 Analog Input Termination Unit for Harmony \/ INFI 90","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e NTAI06 \u003c\/strong\u003eis a high-density analog input termination unit designed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It provides the essential physical connection points for 16 analog field signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e facilitating the transmission of data to the system's input slave modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit is specifically engineered to handle standard industrial current and voltage signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e offering a robust and organized wiring interface that simplifies both installation and routine maintenance in process control environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTAI06\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Capacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Analog Input Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eSupported Signal Types\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 4-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e 1-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e 0-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e 0-10 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Unit Mounting Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface Connector\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 24-pin multi-pin header for I\/O module cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eWiring Termination\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Screw terminal blocks for field connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e44 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eMulti-Channel Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports up to 16 independent analog inputs on a single card,\u003c\/span\u003e\u003cspan class=\"\"\u003e optimizing cabinet space usage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eVersatile Signal Handling\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compatible with a wide range of standard industrial analog signals through appropriate module configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003ePassive Safety Design\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Built with high-reliability passive components to ensure long-term signal integrity without external power.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eStandardized Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for seamless connectivity with IMASI and IMFEC series analog input modules via specialized interface cables.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eStreamlined Maintenance\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Individual field wires can remain terminated during module swaps,\u003c\/span\u003e\u003cspan\u003e significantly reducing system downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eEnvironmental Hardening\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Conformal coating options typically available to protect against corrosive industrial atmospheres and humidity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095707939125,"sku":"NTAI06","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTAI06.jpg?v=1766648005"},{"product_id":"abb-bailey-6640635a1-hydraulic-servo-control-interface-module","title":"ABB Bailey 6640635A1 Hydraulic Servo Control Interface Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003e6640635A1 \u003c\/strong\u003eis a high-precision hydraulic servo control module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This specialized hardware component is responsible for regulating the operation of hydraulic actuators and servo valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e commonly found in steam turbine governor systems and large-scale industrial positioning applications.\u003c\/span\u003e\u003cspan class=\"\"\u003e By processing feedback from LVDT or RVDT sensors and generating high-accuracy drive currents,\u003c\/span\u003e\u003cspan class=\"\"\u003e the 6640635A1 ensures rapid and deterministic response times for critical motion control loops.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its design prioritizes signal stability and thermal resilience,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it a vital part of power generation and heavy process automation infrastructures.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 6640635A1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunction\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Hydraulic Servo Positioning and Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Modular Rack-Mount PCB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eFeedback Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Support for LVDT \/ RVDT position sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Voltage\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provided via system backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Servo valve drive signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eAmbient Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e45 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eAdvanced Servo Control\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Delivers closed-loop regulation of hydraulic actuators with high resolution and minimal deadband.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Conditioning\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Includes on-board circuitry for filtering and stabilizing feedback signals from field-mounted sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eReal-Time Processing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Utilizes dedicated logic to execute positioning algorithms at high scan rates for stable turbine control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSystem Bus Integration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Communicates directly with master controller modules via the Bailey expander bus architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\" class=\"\"\u003eIndustrial Reliability\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Built with ruggedized components to maintain precise output levels even in high-vibration power plant environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\" class=\"\"\u003eFault Monitoring\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features integrated diagnostics to detect sensor failure or output signal discrepancies,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring safe process shutdown if necessary.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095711510837,"sku":"6640635A1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/6640635A1__1.jpg?v=1766648299"},{"product_id":"abb-bailey-ntcl01-a-infi-net-communication-link-termination-unit","title":"ABB Bailey NTCL01-A INFI-Net Communication Link Termination Unit","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTCL01-A \u003c\/strong\u003eis a specialized termination assembly designed for the INFI-Net communication network within the Bailey INFI 90 and Symphony Plus architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit provides the physical interface for the plant loop,\u003c\/span\u003e\u003cspan class=\"\"\u003e facilitating the connection between high-speed network communication modules and the central data highway.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is engineered to maintain high signal fidelity and network stability,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring deterministic data exchange between distributed control system (DCS) nodes.\u003c\/span\u003e\u003cspan class=\"\"\u003e The \"A\" revision typically signifies enhanced hardware resilience or updated connector specifications for modern industrial cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTCL01-A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Protocol\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI-Net (Cnet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCable Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Twin-axial or coaxial plant loop support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Unit Mounting Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface Connectors\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-pin headers for redundant communication modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e42 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eRelative Humidity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Speed Network Interfacing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Enables secure physical bridging for the INFI-Net plant loop communication ring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Equipped with secondary ports to facilitate dual-redundant network configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e preventing system-wide downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Integrity Optimization\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e Features integrated impedance matching and noise filtering to minimize data packet loss across the network backbone.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003ePassive Reliability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Utilizes a high-durability passive circuit design that requires no external power and offers a high Mean Time Between Failures (MTBF).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eHot-Swap Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Allows for the connection or disconnection of network interface modules without interrupting the continuity of the communication loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eRuggedized Terminations\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to withstand the electromagnetic interference and thermal stresses common in power plant and refinery control rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095713083701,"sku":"NTCL01-A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTCL01-A.jpg?v=1766649417"},{"product_id":"abb-bailey-ntcl01-a-infi-net-communication-link-termination-unit-副本","title":"ABB Bailey IMDSI14 Digital Slave Input Module 16-Channel","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMDSI14\u003c\/strong\u003e is a high-density digital input slave module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It serves as the primary interface for acquiring discrete status signals from field equipment,\u003c\/span\u003e\u003cspan class=\"\"\u003e such as limit switches,\u003c\/span\u003e\u003cspan class=\"\"\u003e pushbuttons,\u003c\/span\u003e\u003cspan class=\"\"\u003e and relay contacts.\u003c\/span\u003e\u003cspan class=\"\"\u003e The module processes up to 16 independent inputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e converting field-side voltage states into digital data for the master controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e Designed for high-speed logic execution,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMDSI14 provides the essential data required for sequencing,\u003c\/span\u003e\u003cspan class=\"\"\u003e interlocking,\u003c\/span\u003e\u003cspan class=\"\"\u003e and alarm monitoring in critical industrial process environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMDSI14\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Channels\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Independent Discrete Inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eVoltage Rating\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compatible with 24 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e 48 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e or 125 VDC\/120 VAC (via specific termination units)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eIsolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Optical isolation between field signals and system logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Consumption\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5 Watts (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Occupies one slot in a standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Density Monitoring\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports 16 digital input points per module to optimize cabinet space and hardware efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Signal Processing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Ensures rapid updates to the master controller through the high-speed slave expander bus architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Conditioning and Filtering\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Includes integrated debounce and filtering logic to eliminate false triggering from noisy electrical environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eReal-Time Status Indication\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features front-panel LED indicators for each channel to provide immediate visual verification of input states.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eAdvanced Fault Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously monitors internal hardware health and reports module-level errors to the control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eFlexible Termination Options\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Connects to various N-series termination units,\u003c\/span\u003e\u003cspan\u003e allowing for diverse field voltage compatibility and easy wiring management.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095723962677,"sku":"IMDSI14","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMDSI14.jpg?v=1766649622"},{"product_id":"abb-bailey-imhss03-hydraulic-servo-slave-module","title":"ABB Bailey IMHSS03 Hydraulic Servo Slave Module","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB \u003cstrong\u003eIMHSS03\u003c\/strong\u003e is a high-performance hydraulic servo slave module developed for the Bailey INFI 90 and Symphony Plus control systems. This specialized controller interface is designed to manage closed-loop positioning for hydraulic actuators and servo valves, which are critical in steam turbine governing and complex industrial motion tasks. By accurately processing LVDT or RVDT position feedback and generating precise current outputs to drive servo coils, the IMHSS03 ensures high-speed responsiveness and deterministic control. Its modular architecture allows for seamless integration into standard INFI 90 racks, providing reliable operation in demanding power generation environments.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: IMHSS03\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eModule Type\u003c\/b\u003e: Hydraulic Servo Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eFeedback Inputs\u003c\/b\u003e: Support for dual LVDT\/RVDT sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eOutput Current\u003c\/b\u003e: Configurable servo valve drive signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eCommunication Interface\u003c\/b\u003e: Slave Expander Bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003ePower Consumption\u003c\/b\u003e: 7.5 Watts (Typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Single slot in Module Mounting Unit (MMU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e: 0 to 70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e: 0.58 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003ePrecision Motion Control\u003c\/b\u003e: Executes high-resolution positioning algorithms to maintain tight control over hydraulic valve states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDual-Channel Feedback\u003c\/b\u003e: Accommodates redundant position sensors to ensure system availability and safety in the event of a sensor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eRapid Scan Rates\u003c\/b\u003e: Optimized for low-latency processing, meeting the strict timing requirements of turbine speed and load control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eOn-Board Diagnostics\u003c\/b\u003e: Continuously monitors servo loop health, including open-circuit detection and feedback signal validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eGalvanic Isolation\u003c\/b\u003e: Protects internal system logic from electrical noise and potential surges generated by field-side hydraulic equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eFlexible Calibration\u003c\/b\u003e: Supports software-based zero and span adjustments, simplifying the commissioning of hydraulic actuators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095725175093,"sku":"IMHSS03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMHSS03__1.jpg?v=1766649913"},{"product_id":"abb-bailey-imasi23-16-channel-universal-analog-input-module","title":"ABB Bailey IMASI23 16-Channel Universal Analog Input Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e IMASI23\u003c\/strong\u003e is a versatile analog input slave module designed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It provides high-density signal acquisition for up to 16 independent channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e supporting a wide array of field inputs including current loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e thermocouples,\u003c\/span\u003e\u003cspan class=\"\"\u003e and RTDs.\u003c\/span\u003e\u003cspan class=\"\"\u003e The module is engineered for high-accuracy digitization of process variables,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that critical data is precisely communicated to the master controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e With integrated signal conditioning and robust electrical isolation,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMASI23 is a foundational component for reliable temperature,\u003c\/span\u003e\u003cspan class=\"\"\u003e pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e and flow monitoring in complex industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMASI23\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Density\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Analog Input Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Types\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 4-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e 1-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e Thermocouple (multiple types),\u003c\/span\u003e\u003cspan class=\"\"\u003e RTD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eResolution\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 12-bit Analog-to-Digital conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eIsolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Group and individual channel isolation protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Supply\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provided via the system backplane (+5V,\u003c\/span\u003e\u003cspan class=\"\"\u003e +\/-15V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot occupancy in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eUniversal Input Flexibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Capable of interfacing with diverse sensor types through software configuration and appropriate termination units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eOn-Board Signal Linearization\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Automatically applies conversion algorithms for non-linear sensors like thermocouples to ensure data accuracy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eIntegrated Cold Junction Compensation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e Provides precise thermal referencing for thermocouple inputs to eliminate measurement drift.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eHigh-Speed Data Processing\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Delivers rapid signal updates to the system controller via the high-bandwidth slave expander bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eComprehensive Self-Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously monitors internal circuitry and field wiring status,\u003c\/span\u003e\u003cspan\u003e flagging open-circuit or out-of-range conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Noise Rejection\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Equipped with advanced filtering to suppress electromagnetic interference commonly found in power plant environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095727141173,"sku":"IMASI23","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMASI23.jpg?v=1766650077"},{"product_id":"abb-bailey-imdsm04-pulse-input-slave-module-8-channel","title":"ABB Bailey IMDSM04 Pulse Input Slave Module 8-Channel","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMDSM04 \u003c\/strong\u003eis a high-performance pulse input slave module designed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is specifically engineered to count and process high-frequency signals from field devices such as flow meters,\u003c\/span\u003e\u003cspan class=\"\"\u003e tachometers,\u003c\/span\u003e\u003cspan class=\"\"\u003e and encoders.\u003c\/span\u003e\u003cspan class=\"\"\u003e By converting pulse trains into digital values,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMDSM04 allows the master controller to calculate precise flow totals,\u003c\/span\u003e\u003cspan class=\"\"\u003e rotational speeds,\u003c\/span\u003e\u003cspan class=\"\"\u003e and volumetric measurements.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is a critical component for applications requiring accurate dynamic monitoring and accumulation in power generation and liquid processing industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMDSM04\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Capacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 8 Independent Pulse Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Frequency Range\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Up to 50 kHz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eResolution\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16-bit pulse accumulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC via system backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eIsolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Optical isolation for field-side signal protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\" class=\"\"\u003eWeight\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e52 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Frequency Acquisition\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Capable of processing rapid pulse streams up to 50 kHz for precision speed and flow tracking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eFlexible Input Conditioning\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports various signal types including dry contacts,\u003c\/span\u003e\u003cspan class=\"\"\u003e open collectors,\u003c\/span\u003e\u003cspan class=\"\"\u003e and voltage pulses.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eIndependent Accumulation\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Each of the 8 channels features its own dedicated counter to ensure zero data loss during high-speed transitions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIntegrated Debounce Logic\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built-in digital filtering prevents false counts caused by contact bounce or electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eSlave Bus Synchronization\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Transfers processed data to the Harmony Area Controller via a high-speed expander bus for real-time logic execution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eComprehensive Self-Testing\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features continuous hardware diagnostics to monitor board health and communication integrity.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095728386357,"sku":"IMDSM04","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMDSM041.jpg?v=1766650448"},{"product_id":"abb-bailey-tps02-turbine-protection-system-slave-module","title":"ABB Bailey TPS02 Turbine Protection System Slave Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"citation-406 citation-end-406\"\u003eThe ABB \u003cstrong\u003eTPS02\u003c\/strong\u003e is a specialized safety interface module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"citation-405 citation-end-405\"\u003eIt is primarily utilized in power generation for critical turbine protection and overspeed monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module provides a dedicated link between the system’s logic and the turbine trip circuitry,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring rapid and deterministic execution of emergency shutdown commands.\u003c\/span\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"citation-404 citation-end-404 animating\"\u003eBy monitoring essential process parameters and mechanical states, the TPS02 helps prevent catastrophic equipment failure and maintains the integrity of the steam or gas turbine control loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e TPS02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cspan class=\"citation-403 animating\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"animating\"\u003e\u003cspan class=\"citation-403\"\u003eProduct Series\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-403 citation-end-403\"\u003e: INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cspan class=\"citation-402 animating\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"animating\"\u003e\u003cspan class=\"citation-402\"\u003eModule Type\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-402 citation-end-402\"\u003e: Turbine Protection Slave\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Redundant trip inputs and speed sensor signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Emergency trip relay drivers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Supply\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (backplane powered)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cspan class=\"citation-401 animating\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"animating\"\u003e\u003cspan class=\"citation-401\"\u003eHigh-Speed Trip Logic\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-401 citation-end-401\"\u003e: Designed for low-latency signal processing to meet stringent turbine safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compatible with redundant system architectures to ensure protection remains active even during single-component failures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Performance\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Operates on a dedicated slave bus to avoid network congestion and ensure consistent response times.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSafety Isolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features electrical separation between sensitive control logic and high-power turbine trip solenoids.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\" class=\"\"\u003eReal-Time Diagnostics\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Includes internal hardware verification routines that report status and fault conditions to the master controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095731138869,"sku":"TPS02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TPS02__1.jpg?v=1766650692"},{"product_id":"abb-bailey-imfcs01-frequency-counter-slave-module","title":"ABB Bailey IMFCS01 Frequency Counter Slave Module","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB \u003cstrong\u003eIMFCS01\u003c\/strong\u003e is a high-precision frequency counter slave module designed for the Bailey INFI 90 and Symphony Plus distributed control systems. This module is engineered to monitor and process periodic signal inputs from various field devices, such as magnetic pickups, flow meters, and speed sensors. By providing accurate frequency-to-digital conversion, the IMFCS01 enables real-time tracking of rotational speeds and flow velocities. It operates within a modular rack environment, communicating critical timing data to the master controller to ensure precise regulation of dynamic industrial processes.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: IMFCS01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eModule Type\u003c\/b\u003e: Frequency Counter Slave\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eInput Channels\u003c\/b\u003e: Multi-channel frequency acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eSignal Compatibility\u003c\/b\u003e: Pulse, Sine Wave, and Square Wave inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eInterface\u003c\/b\u003e: Slave Expander Bus (Internal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eFrequency Range\u003c\/b\u003e: Broad spectrum for speed and flow monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e: +5 VDC (Backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Single slot in Module Mounting Unit (MMU)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eAccurate Velocity Monitoring\u003c\/b\u003e: Specialized for calculating rotational speed (RPM) and volumetric flow rates based on input signal frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eBroad Signal Sensitivity\u003c\/b\u003e: Capable of detecting low-voltage AC signals from magnetic pickups as well as standard digital pulse trains.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eIntegrated Signal Filtering\u003c\/b\u003e: Features hardware-based noise suppression to maintain count accuracy in high-EMI industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eSeamless Bus Integration\u003c\/b\u003e: Transmits processed data across the local expander bus for low-latency synchronization with Harmony controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eReal-Time Health Monitoring\u003c\/b\u003e: Includes internal diagnostic routines to verify circuit integrity and report hardware status via LED indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eRuggedized Construction\u003c\/b\u003e: Designed to maintain performance stability within the demanding thermal and electrical environments of power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095731990837,"sku":"IMFCS01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMFCS01.jpg?v=1766654216"},{"product_id":"abb-bailey-ntai05-analog-input-termination-unit","title":"ABB Bailey NTAI05 Analog Input Termination Unit","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTAI05\u003c\/strong\u003e is a specialized analog input termination assembly developed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit acts as the physical connection bridge for up to 16 analog field signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e including standard 4-20 mA current loops and various voltage inputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is designed to streamline the transition between field wiring and the system’s internal I\/O slave modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e Built with industrial-grade reliability,\u003c\/span\u003e\u003cspan class=\"\"\u003e the NTAI05 ensures signal integrity through organized routing and secure screw-terminal connections,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it essential for precision monitoring in power generation and heavy process industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTAI05\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eChannel Capacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Analog Inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCompatible Signals\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 4-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e 1-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e 0-10 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Unit Mounting Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface Ports\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-pin headers for connection to IMASI or IMFEC modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eConnection Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Rugged screw-terminal blocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eRelative Humidity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Density Signal Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Consolidates 16 independent analog channels into a single modular footprint to maximize cabinet space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003ePassive Circuit Reliability\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Utilizes high-quality passive components for long-term maintenance-free operation without external power requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSimplified Maintenance\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Field wiring remains intact during I\/O module replacement,\u003c\/span\u003e\u003cspan\u003e reducing the risk of wiring errors and minimizing downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eRedundant Logic Support\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Compatible with redundant I\/O configurations to ensure continuous data availability for mission-critical loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eAdvanced Noise Suppression\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Integrated electrical architecture helps mitigate electromagnetic interference to preserve analog signal precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSystem Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Engineered for seamless physical and electrical synchronization with Harmony Area Controllers and associated Slave Expander Bus hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095826428213,"sku":"NTAI05","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTAI05__1.jpg?v=1766654803"},{"product_id":"abb-bailey-ntdi21-a-digital-input-termination-unit","title":"ABB Bailey NTDI21-A Digital Input Termination Unit","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTDI21-A\u003c\/strong\u003e is a high-density digital input termination unit designed for use within the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It acts as the physical junction for field-level discrete signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e facilitating the connection of status contacts to the system's digital input modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit is specifically engineered to handle 24 VDC logic levels and provides organized routing for up to 16 input channels.\u003c\/span\u003e\u003cspan class=\"\"\u003e By consolidating field wiring into a standardized interface,\u003c\/span\u003e\u003cspan class=\"\"\u003e the NTDI21-A ensures reliable signal transmission and simplifies the overall cabinet architecture in demanding industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTDI21-A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Channels\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Discrete Points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Voltage\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 24 VDC nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Unit Mounting Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface Connector\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-pin header for I\/O module cables\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eWiring Terminal Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compression-style screw terminals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperational Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eCoating\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard industrial PCB protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eEfficient Signal Routing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Distributes 16 independent digital inputs across a compact modular footprint to maximize enclosure space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eStreamlined Maintenance\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Allows for the replacement of digital slave modules without the need to disconnect or label individual field wires.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003ePassive Circuit Architecture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e Features a high-reliability passive design that eliminates the need for external power at the termination level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eLogic Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Optimized for use with 24 VDC discrete signals common in motor control and switchgear monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eRobust Hardware Interface\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Equipped with heavy-duty terminal blocks to ensure secure mechanical and electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSystem Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for direct compatibility with IMDSI series digital input slave modules via standard system cabling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095827607861,"sku":"NTDI21-A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTDI21-A.jpg?v=1766655263"},{"product_id":"abb-bailey-nths03-hydraulic-servo-termination-unit","title":"ABB Bailey NTHS03 Hydraulic Servo Termination Unit","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTHS03\u003c\/strong\u003e is a specialized termination assembly designed to bridge field-side hydraulic components with the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit provides a robust physical interface for connecting servo valve coils and feedback sensors,\u003c\/span\u003e\u003cspan class=\"\"\u003e such as LVDTs and RVDTs,\u003c\/span\u003e\u003cspan class=\"\"\u003e to the system's control logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is specifically engineered to handle the high-precision signal requirements of turbine governor systems and heavy-duty positioning actuators.\u003c\/span\u003e\u003cspan class=\"\"\u003e By providing organized screw-terminal connections and integrated signal routing,\u003c\/span\u003e\u003cspan class=\"\"\u003e the NTHS03 ensures the electrical stability necessary for critical hydraulic loop performance in power plants and industrial facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTHS03\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eApplication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Hydraulic Servo Loop Termination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eFeedback Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Compatible with LVDT and RVDT position sensors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Unit Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-pin connector for IMHSS series modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eConnection Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Heavy-duty screw terminals for field wiring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eRelative Humidity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eDedicated Servo Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered specifically for the complex wiring requirements of hydraulic positioning and valve control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Integrity Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features on-board pathways designed to minimize electromagnetic interference and signal attenuation in sensitive feedback loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eStreamlined Maintenance\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Individual field wires remain permanently landed on the unit,\u003c\/span\u003e\u003cspan\u003e allowing for the rapid replacement of control modules without re-wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eDual Feedback Channel Support\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Accommodates redundant sensor wiring to enhance system reliability and process safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003ePassive Safety Architecture\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Utilizes high-reliability passive circuitry to maintain signal continuity without requiring secondary local power.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eDurable Industrial Design\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to withstand the harsh thermal and vibration profiles typically found in steam and gas turbine environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095830589749,"sku":"NTHS03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTHS03__1.jpg?v=1766655538"},{"product_id":"abb-bailey-ntr012-a-actuator-and-sensor-termination-unit","title":"ABB Bailey NTR012-A Actuator and Sensor Termination Unit","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eNTR012-A\u003c\/strong\u003e is a specialized termination assembly designed to provide a robust physical interface for actuator control and sensor feedback within the Bailey INFI 90 and Symphony Plus architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit facilitates the organized connection of field-side signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring high-fidelity data transmission between heavy-duty process actuators and the system's I\/O slave modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered for industrial reliability,\u003c\/span\u003e\u003cspan class=\"\"\u003e the NTR012-A handles complex signal routing in a centralized terminal block format,\u003c\/span\u003e\u003cspan class=\"\"\u003e which is essential for precise positioning and monitoring in turbine control or large-scale valve automation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e NTR012-A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Category\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Actuator and Sensor Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting Configuration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard N-type Termination Mounting Base\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eInput\/Output Capacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-channel actuator drive and feedback routing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eWiring Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Industrial-grade screw terminal blocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eBackplane Connector\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 24-pin multi-pin header for slave module cabling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperational Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eRelative Humidity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eIntegrated Signal Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Bridges the gap between sensitive control logic and ruggedized field actuators through a dedicated termination pathway.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003ePassive Reliability\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Built with a passive circuit design that maximizes Mean Time Between Failures (MTBF) by eliminating the need for local active power components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eStreamlined Wiring Architecture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Consolidates multiple actuator and sensor lines into a single modular footprint,\u003c\/span\u003e\u003cspan class=\"\"\u003e reducing cabinet clutter and potential wiring errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eOptimized Maintenance\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Supports efficient troubleshooting and module hot-swapping by keeping field cables permanently landed during service procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eEnhanced Signal Integrity\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Optimized for low-noise performance,\u003c\/span\u003e\u003cspan\u003e protecting critical sensor feedback loops from electromagnetic interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Durability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Specifically designed for long-term deployment in the harsh thermal and electrical conditions of power generation and chemical processing plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095833309493,"sku":"NTR012-A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/NTR012-A.jpg?v=1766655714"},{"product_id":"abb-bailey-innpm22-network-processing-interface-module","title":"ABB Bailey INNPM22 Network Processing Interface Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eINNPM22\u003c\/strong\u003e is a core network processor module designed for the Symphony Plus and INFI 90 distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It functions as the primary intelligence for managing communications between the Harmony control unit and the high-speed INFI-Net plant loop.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is responsible for coordinating data traffic,\u003c\/span\u003e\u003cspan class=\"\"\u003e executing network protocols,\u003c\/span\u003e\u003cspan class=\"\"\u003e and ensuring that process variables are synchronized across the DCS backbone.\u003c\/span\u003e\u003cspan class=\"\"\u003e By offloading communication tasks from the main controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e the INNPM22 maintains system determinism and high-speed data throughput,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it essential for large-scale industrial plants requiring reliable,\u003c\/span\u003e\u003cspan class=\"\"\u003e real-time information exchange between multiple control nodes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INNPM22\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Category\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Communication Processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication Port\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Serial interface for communication modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eBackplane Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Harmony Control Bus \/ Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMemory\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated flash and RAM for protocol buffering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eStatus Indication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-segment front-panel LED display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Powered via standard backplane (+5 VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Speed Throughput\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Optimized for low-latency data processing across the INFI-Net communication highway.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Performance\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Ensures predictable data delivery cycles,\u003c\/span\u003e\u003cspan class=\"\"\u003e which is critical for synchronous control in power and water utilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProtocol Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e Handles complex network layer tasks independently,\u003c\/span\u003e\u003cspan\u003e allowing the main processor to focus exclusively on control logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eRedundant Configuration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Fully supports redundant pairing to eliminate single points of failure within the communication sub-system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eReal-Time Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features comprehensive self-monitoring that reports module health and network traffic statistics to the operator workstation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eBackward Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed to integrate seamlessly with legacy INFI 90 hardware while providing the performance upgrades required for modern Symphony Plus systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095834554677,"sku":"INNPM22","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INNPM22.jpg?v=1766656071"},{"product_id":"abb-bailey-immpi01-multi-function-processor-interface-module","title":"ABB Bailey IMMPI01 Multi-Function Processor Interface Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMMPI01\u003c\/strong\u003e is a high-performance processor interface module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e It functions as a critical communication bridge between Multi-Function Processors (MFP) and auxiliary hardware,\u003c\/span\u003e\u003cspan class=\"\"\u003e enabling the seamless exchange of complex control data and configuration parameters.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is designed to offload specific I\/O processing tasks and serial communication management from the primary controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e thereby enhancing overall loop response times.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is widely utilized in large-scale utility and industrial automation environments where multi-layered processor coordination is essential for maintaining plant stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMMPI01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Role\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-Function Processor Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eProtocol Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Specialized Bailey high-speed serial protocols\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eBus Architecture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus \/ Control Bus compatible\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU) slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Consumption\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Watts (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eDiagnostic Indicators\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Front-panel LEDs for power,\u003c\/span\u003e\u003cspan class=\"\"\u003e status,\u003c\/span\u003e\u003cspan class=\"\"\u003e and error detection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eEnhanced Data Throughput\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provides a dedicated hardware pathway for high-volume data packets,\u003c\/span\u003e\u003cspan class=\"\"\u003e reducing bottlenecking in the main control logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eIntelligent Buffer Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features on-board memory to buffer incoming and outgoing signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring data integrity during peak network traffic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Synchronization\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Maintains precise timing alignment between the processor and connected peripheral modules for synchronous control loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eHardware-Based Error Checking\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Employs rigorous parity and checksum validation to prevent corrupted data from affecting the process control strategy.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eScalable Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Allows for the expansion of system capabilities by facilitating the addition of specialized slave modules to an existing MFP rack.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Hardening\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Engineered with robust electromagnetic shielding to ensure reliable operation near high-voltage switching equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095842713909,"sku":"IMMPI01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMMPI01__1.jpg?v=1766656298"},{"product_id":"abb-bailey-inict03a-infi-net-to-computer-communication-interface","title":"ABB Bailey INICT03A INFI-Net to Computer Communication Interface","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e INICT03A\u003c\/strong\u003e is a high-performance communication interface module designed to bridge the Bailey INFI 90 plant loop (Cnet) with external computer systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module serves as a vital gateway,\u003c\/span\u003e\u003cspan class=\"\"\u003e enabling human-machine interfaces (HMI),\u003c\/span\u003e\u003cspan class=\"\"\u003e engineering workstations,\u003c\/span\u003e\u003cspan class=\"\"\u003e and data historians to access real-time process information.\u003c\/span\u003e\u003cspan class=\"\"\u003e By converting the proprietary INFI-Net protocol into a format compatible with computer-based applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e the INICT03A facilitates comprehensive system monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e remote configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e and advanced data logging.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is a critical component for plant-wide integration,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing the high-speed data throughput necessary for modern industrial supervisory control.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INICT03A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Role\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Cnet-to-Computer Transfer Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI-Net (Plant Loop)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eHost Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e SCSI or Serial (depending on configuration)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eData Rate\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed deterministic transmission\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC backplane power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBi-Directional Communication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports full duplex data transfer for both reading process variables and sending configuration commands from a host PC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Transparency\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Allows external software to interact with all nodes on the INFI-Net loop as if they were locally connected.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eHigh-Speed Buffering\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features integrated memory to manage data packet traffic,\u003c\/span\u003e\u003cspan\u003e preventing information loss during high-demand network cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eSystem Security\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Provides a controlled access point for engineering tools,\u003c\/span\u003e\u003cspan\u003e ensuring that network integrity is maintained during remote diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003ePlug-and-Play Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for straightforward installation into existing Symphony Plus and INFI 90 hardware racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eStatus Monitoring\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Equipped with front-panel indicators that provide immediate visual feedback on network activity and module health.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095843041589,"sku":"INICT03A","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INICT03A__1.jpg?v=1766656578"},{"product_id":"abb-bailey-imcp02-infi-net-multibus-communication-processor-module","title":"ABB Bailey IMCP02 Infi-Net Multibus Communication Processor Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e IMCP02 \u003c\/strong\u003eis a high-performance communication processor module designed to facilitate complex data exchange within the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module acts as a sophisticated gateway between the proprietary high-speed Infi-Net plant loop and Multibus-based hardware architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its primary function is to manage the translation and routing of process data,\u003c\/span\u003e\u003cspan class=\"\"\u003e control commands,\u003c\/span\u003e\u003cspan class=\"\"\u003e and system diagnostics across disparate bus structures.\u003c\/span\u003e\u003cspan class=\"\"\u003e By utilizing dedicated on-board processing power,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMCP02 ensures that high-volume network traffic does not interfere with the deterministic execution of critical control loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it indispensable for large-scale,\u003c\/span\u003e\u003cspan class=\"\"\u003e networked industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMCP02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Communication Processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eArchitecture Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Infi-Net to Multibus Gateway\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eProtocol Handling\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Real-time asynchronous and synchronous data management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMemory Configuration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated RAM and ROM for protocol firmware and buffering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (provided via system backplane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eSlot Requirement\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot occupancy in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eMultibus Integration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Specifically engineered to link Infi-Net communication highways with Multibus-compliant hardware components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Data Transfer\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Employs advanced scheduling algorithms to ensure that time-critical process data receives priority during network transmission.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eAutonomous Processing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Reduces the overhead on main controller modules by independently managing network layer protocols and error correction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eSystem-Wide Connectivity\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Enables transparent access to data points located on different segments of the plant loop for improved supervisory control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eComprehensive Self-Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously audits hardware integrity and communication link status,\u003c\/span\u003e\u003cspan\u003e providing immediate fault reporting to the operator interface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial-Grade Reliability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to withstand the rigorous electrical and thermal demands of power generation and heavy manufacturing facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095845564725,"sku":"IIMCP02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IIMCP02.jpg?v=1766656849"},{"product_id":"abb-bailey-iepas02-ac-power-supply-module-for-infi-90-systems","title":"ABB Bailey IEPAS02 AC Power Supply Module for INFI 90 Systems","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIEPAS02\u003c\/strong\u003e is a high-reliability AC system power supply module engineered specifically for the Bailey INFI 90 and Symphony Plus distributed control system (DCS) architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e This unit is designed to convert standard alternating current (AC) input into the regulated direct current (DC) voltages required to drive various control and I\/O modules within a module mounting unit.\u003c\/span\u003e\u003cspan class=\"\"\u003e It plays a critical role in maintaining system stability by providing a clean,\u003c\/span\u003e\u003cspan class=\"\"\u003e consistent power source capable of withstanding industrial electrical fluctuations.\u003c\/span\u003e\u003cspan class=\"\"\u003e The IEPAS02 is essential for ensuring the continuous operation of processor and communication hardware in demanding utility and process control environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IEPAS02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Voltage\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 120 VAC or 240 VAC (Selectable)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Voltages\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e +15 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e -15 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eCurrent Capacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Optimized for high-density module racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eForm Factor\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard INFI 90 Power Module slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eCooling\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Convection cooled with integrated heat sinks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eProtection Logic\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Overvoltage and short-circuit protection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eMulti-Rail Output\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Delivers all necessary voltage levels (+5V and +\/-15V) to support both digital logic and analog signal conditioning circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Can be installed in parallel configurations to provide N+1 redundancy,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring no loss of control during a power unit failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eIndustrial Noise Isolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features advanced internal filtering to prevent line transients and EMI from affecting sensitive DCS processors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eThermal Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Built with a rugged mechanical frame designed for efficient heat dissipation,\u003c\/span\u003e\u003cspan class=\"\"\u003e extending the life of internal electrolytic components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eFront-Panel Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Equipped with visual status indicators for each voltage rail,\u003c\/span\u003e\u003cspan\u003e allowing for rapid verification of power health at the cabinet level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSeamless Backplane Connection\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Utilizes a heavy-duty connector designed for secure engagement with the power bus bars of the Module Mounting Unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095847399733,"sku":"IEPAS02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IEPAS02.jpg?v=1766657180"},{"product_id":"abb-bailey-iepas02-ac-power-supply-module-for-infi-90-systems-副本","title":"ABB Bailey INIIT03 Infi-Net to Infi-Net Local Transfer Interface Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eINIIT03\u003c\/strong\u003e is a high-speed network communication module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This local transfer interface acts as a vital bridge between two separate Infi-Net communication rings,\u003c\/span\u003e\u003cspan class=\"\"\u003e allowing for the seamless exchange of data packets and process variables across different network segments.\u003c\/span\u003e\u003cspan class=\"\"\u003e By facilitating local network expansion,\u003c\/span\u003e\u003cspan class=\"\"\u003e the INIIT03 enables larger plant architectures to maintain high-speed,\u003c\/span\u003e\u003cspan class=\"\"\u003e deterministic performance while keeping control traffic organized.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is essential for complex industrial facilities that require synchronized communication between multiple localized control loops without compromising the integrity of the primary plant loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INIIT03\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Category\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Local Network Transfer Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eCompatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI-Net (Cnet) Architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eData Transmission Rate\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed synchronous transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eBus Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Harmony Control Bus \/ Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Occupies one slot in a standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Supply\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC via system backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\" class=\"\"\u003eFault Tolerance\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports redundant network loop configurations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eInter-Ring Communication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provides a dedicated hardware gateway to link adjacent Infi-Net segments for unified system monitoring and control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Data Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Employs advanced protocol handling to ensure time-critical process data is transferred with minimal latency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Isolation and Security\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Prevents localized network faults in one ring from propagating to the other,\u003c\/span\u003e\u003cspan class=\"\"\u003e enhancing overall system availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Volume Buffering\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e Integrated memory architecture manages incoming and outgoing data packets to prevent network congestion during peak cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eOn-Board Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features real-time hardware monitoring with front-panel LED indicators to provide immediate feedback on network status and error conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003ePlug-and-Play Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for standard INFI 90 hardware racks,\u003c\/span\u003e\u003cspan\u003e allowing for straightforward integration into existing control cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095870665013,"sku":"INIIT03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INIIT03__1.jpg?v=1766658202"},{"product_id":"abb-bailey-imset01-sequence-of-events-time-keeper-module","title":"ABB Bailey IMSET01 Sequence of Events Time Keeper Module","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB\u003cstrong\u003e IMSET01\u003c\/strong\u003e is a precision time-synchronization module developed for the Bailey INFI 90 and Symphony Plus distributed control systems. Its primary function is to act as the master chronological reference for Sequence of Events (SOE) monitoring across the control network. By maintaining a highly accurate internal clock and distributing time-sync pulses to digital input modules, the IMSET01 ensures that discrete state changes—such as relay trips or valve movements—are timestamped with millisecond resolution. This capability is vital for post-incident root cause analysis and forensic event reconstruction in high-stakes environments like power generation and utility substations.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: IMSET01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eFunction\u003c\/b\u003e: SOE Master Time Keeper\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eTimestamp Resolution\u003c\/b\u003e: 1 millisecond\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eCommunication\u003c\/b\u003e: Slave Expander Bus \/ Plant Loop Synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e: +5 VDC via system backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Single slot occupancy in standard MMU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e: 0 to 70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eIndicators\u003c\/b\u003e: Front-panel LEDs for status and sync verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eHigh-Resolution Synchronization\u003c\/b\u003e: Provides the master temporal reference required to align timestamps across multiple distributed I\/O racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDeterministic Event Logging\u003c\/b\u003e: Enables the system to capture and record the exact chronological order of rapid-fire digital transitions during plant upsets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eNetwork Clock Coordination\u003c\/b\u003e: Synchronizes with higher-level plant clocks or GPS sources to maintain absolute time accuracy across the entire DCS architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIndependent Processor Architecture\u003c\/b\u003e: Features dedicated on-board logic to manage timekeeping tasks without consuming resources from the primary control processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eAdvanced Error Reporting\u003c\/b\u003e: Continuously monitors clock stability and synchronization pulse integrity, reporting any drift or hardware failures to the HMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Durability\u003c\/b\u003e: Designed with high-stability oscillators and robust circuitry to ensure reliable performance in electrically noisy industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095875318069,"sku":"IMSET01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMSET01.jpg?v=1766658640"},{"product_id":"abb-bailey-imsed01-sequence-of-events-digital-input-module","title":"ABB Bailey IMSED01 Sequence of Events Digital Input Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e IMSED01\u003c\/strong\u003e is a specialized digital input module engineered for high-speed discrete signal monitoring within the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e Unlike standard digital input cards,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMSED01 is specifically designed for Sequence of Events (SOE) applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e where the exact timing of status changes is critical.\u003c\/span\u003e\u003cspan class=\"\"\u003e It captures and timestamps state transitions from field devices such as circuit breakers,\u003c\/span\u003e\u003cspan class=\"\"\u003e protective relays,\u003c\/span\u003e\u003cspan class=\"\"\u003e and emergency stop switches with millisecond precision.\u003c\/span\u003e\u003cspan class=\"\"\u003e By interfacing with a master time-keeper module,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMSED01 ensures that rapid-fire event sequences are accurately recorded for diagnostic analysis and fault reconstruction in power generation and mission-critical industrial processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMSED01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e SOE Digital Input Slave\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eChannel Capacity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Discrete Input Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eTimestamp Resolution\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 1.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Millisecond\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Voltage\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Typically 24 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e 48 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e or 125 VDC (depending on termination)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (Backplane Powered)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Speed Event Capture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered to detect and lock in state changes that occur too rapidly for standard controller scan cycles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003ePrecise Chronological Logging\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Works in synchronization with the IMSET01 module to provide a unified time base across multiple I\/O racks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eAdvanced Input Filtering\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Utilizes sophisticated hardware debouncing and software filtering to eliminate false triggers caused by electrical noise or contact bounce.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eAutonomous Processing\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Performs local signal conditioning and timestamping,\u003c\/span\u003e\u003cspan\u003e reducing the processing burden on the Harmony area controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eComprehensive Self-Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously monitors internal circuitry and backplane communication integrity,\u003c\/span\u003e\u003cspan\u003e with real-time fault reporting via front-panel LEDs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSystem Scalability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for hot-swappable installation into standard module mounting units,\u003c\/span\u003e\u003cspan\u003e facilitating easy system expansion and maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095884853557,"sku":"IMSED01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMSED01__1.jpg?v=1766659699"},{"product_id":"abb-rmba-01-kit-modbus-rtu-adapter-communication-kit","title":"ABB RMBA-01-KIT Modbus RTU Adapter Communication Kit","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB \u003cstrong\u003eRMBA-01-KIT\u003c\/strong\u003e is a specialized serial communication interface designed to integrate ABB industrial drives into Modbus RTU networks. This adapter kit enables seamless bidirectional data exchange between a master controller, such as a PLC or DCS, and the variable speed drive. It is primarily utilized for remote monitoring, parameter adjustment, and drive control in automated industrial environments. By employing the RMBA-01-KIT, operators can access real-time diagnostic data and operational status without direct physical access to the drive hardware. The kit is engineered for easy installation and reliable performance in high-interference electrical settings common in manufacturing and HVAC applications.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: RMBA-01-KIT\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProtocol\u003c\/b\u003e: Modbus RTU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eInterface Type\u003c\/b\u003e: RS-485 Serial\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eBaud Rates\u003c\/b\u003e: 600 bps to 19.2 kbps (adjustable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eDrive Compatibility\u003c\/b\u003e: ACS550, ACS800, and DCS800 series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Direct drive slot attachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003eTopology\u003c\/b\u003e: Daisy-chain or Point-to-point\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003ePower Supply\u003c\/b\u003e: Powered internally via the drive interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eIsolation\u003c\/b\u003e: Galvanically isolated signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eSimplified Network Integration\u003c\/b\u003e: Provides a standardized Modbus RTU gateway for ABB drives, reducing the need for complex custom gateways.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eReal-Time Control\u003c\/b\u003e: Supports high-speed transmission of control words and reference values for precise motor speed regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eRemote Parameter Access\u003c\/b\u003e: Allows for the reading and writing of drive internal parameters over the RS-485 network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eDiagnostic Transparency\u003c\/b\u003e: Enables the collection of fault history and operational metrics, facilitating predictive maintenance strategies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eGalvanic Protection\u003c\/b\u003e: Built-in electrical isolation protects the drive’s control board from network-side surges and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eCompact Hardware Design\u003c\/b\u003e: The small form factor allows for installation within the drive's existing housing, maintaining a clean cabinet layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095892488501,"sku":"RMBA-01-KIT","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/RMBA-01-KIT__1_bb91b23c-f277-46ee-b5ea-048a39e10a6a.jpg?v=1766659961"},{"product_id":"abb-bailey-ipfld125-distributed-power-system-filter-module","title":"ABB Bailey IPFLD125 Distributed Power System Filter Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e IPFLD125\u003c\/strong\u003e is a high-performance power filtration module engineered for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is specifically designed to manage and clean the 125 VDC power distribution within the system rack,\u003c\/span\u003e\u003cspan class=\"\"\u003e protecting sensitive electronic components from voltage spikes,\u003c\/span\u003e\u003cspan class=\"\"\u003e surges,\u003c\/span\u003e\u003cspan class=\"\"\u003e and electromagnetic interference (EMI).\u003c\/span\u003e\u003cspan class=\"\"\u003e It acts as a specialized power system interface that ensures the integrity of the DC bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing stabilized current to associated I\/O modules and processors.\u003c\/span\u003e\u003cspan class=\"\"\u003e By mitigating electrical noise at the source,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IPFLD125 maintains the high availability and reliability required for mission-critical operations in power generation and heavy industrial processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IPFLD125\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Voltage\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 125 VDC Nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eFunction\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e DC Power Filtration and Distribution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU) slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eProtection Features\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated surge suppression and noise filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eEnvironmental Rating\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Industrial grade for high-temperature stability\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eCooling\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Natural convection within the rack assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Efficiency Noise Suppression\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Attenuates high-frequency interference to prevent data corruption in sensitive control logic and communication buses.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eTransient Voltage Protection\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Shields downstream DCS hardware from damaging voltage transients common in 125 VDC battery-backed systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundant Power Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Designed for integration into redundant power architectures to eliminate single points of failure in the distribution loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIndustrial Hardening\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built with robust components capable of continuous operation in the demanding thermal environments of control cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003ePassive Reliability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features a high-reliability hardware design that provides long-term service with minimal maintenance requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSeamless Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Fully compatible with standard Bailey power bus bars and termination units for rapid field installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095893143861,"sku":"IPFLD125","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IPFLD125.jpg?v=1766660144"},{"product_id":"abb-bailey-inict01-infi-net-to-computer-transfer-interface-module","title":"ABB Bailey INICT01 Infi-Net to Computer Transfer Interface Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eINICT01 \u003c\/strong\u003eis a foundational communication gateway developed for the Bailey INFI 90 distributed control system.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module serves as the primary hardware bridge between the proprietary high-speed Infi-Net (Cnet) plant loop and external host computer systems or human-machine interfaces (HMI).\u003c\/span\u003e\u003cspan class=\"\"\u003e By translating complex network protocols into data formats compatible with PC-based applications,\u003c\/span\u003e\u003cspan class=\"\"\u003e the INICT01 allows operators and engineers to perform real-time monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e system configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e and data acquisition.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is engineered to handle high-volume data traffic while maintaining the deterministic performance required for stable industrial automation and large-scale power utility management.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INICT01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Function\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network-to-Computer Data Transfer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Protocol\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Infi-Net (Cnet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eBackplane Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Harmony Control Bus \/ Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eData Throughput\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed serial\/parallel conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU) slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Supply\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (backplane powered)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eStatus Monitoring\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Front-panel diagnostic LED array\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eSeamless Protocol Conversion\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Bridges the gap between the real-time DCS network and standard supervisory computer systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Data Handling\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Ensures that critical process variables are prioritized during the transfer process to prevent information latency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eIntegrated Hardware Buffer\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features on-board memory to manage data bursts and ensure continuous information flow without packet loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eAdvanced Error Detection\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Performs continuous parity and checksum verification to maintain the integrity of data transferred from the plant loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003ePlug-and-Play Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Specifically designed for legacy INFI 90 architectures,\u003c\/span\u003e\u003cspan\u003e allowing for easy replacement or network expansion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eRugged Industrial Design\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Constructed with heavy-duty components to operate reliably in high-temperature and high-vibration control environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095894094133,"sku":"INICT01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INICT011__1.jpg?v=1766660320"},{"product_id":"abb-bailey-imdso04-digital-slave-output-control-module","title":"ABB Bailey IMDSO04 Digital Slave Output Control Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e IMDSO04 \u003c\/strong\u003eis a high-density digital output interface designed for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module serves as a command execution component,\u003c\/span\u003e\u003cspan class=\"\"\u003e translating logic signals from the master controller into discrete electrical outputs to drive field equipment such as solenoids,\u003c\/span\u003e\u003cspan class=\"\"\u003e relays,\u003c\/span\u003e\u003cspan class=\"\"\u003e and motor starters.\u003c\/span\u003e\u003cspan class=\"\"\u003e Operating as a slave module on the expander bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMDSO04 provides isolated control channels that safeguard the primary processor from field-side electrical noise and transients.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is engineered for industrial-grade reliability,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring consistent switching performance in critical process automation and utility control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMDSO04\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Digital Slave Output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Channels\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 16 Discrete Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eIsolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Opto-isolated between system logic and field circuitry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU) slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Consumption\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Powered via +5 VDC system backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eIsolated Signal Routing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Utilizes optical isolation to prevent field-side surges from damaging sensitive backplane electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Switching\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Provides rapid response times for discrete control loops,\u003c\/span\u003e\u003cspan\u003e essential for synchronized plant operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSlave Bus Architecture\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Seamlessly integrates with Multi-Function Processors (MFP) or Harmony Area Controllers (HAC) via the local expander bus.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eOn-Board Intelligence\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features localized logic to manage output states and report channel-specific health status back to the controller.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eDiagnostic Feedback\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Front-panel LED indicators provide real-time visual confirmation of output states and module status.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Durability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for long-term deployment in high-vibration and thermally variable control room environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095901237557,"sku":"IMDSO04","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMDSO04.jpg?v=1766660494"},{"product_id":"abb-bailey-6637830g1-infi-90-system-bus-monitor-module","title":"ABB Bailey 6637830G1 INFI 90 System Bus Monitor Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e 6637830G1 \u003c\/strong\u003eis a specialized diagnostic instrument designed for real-time surveillance of the INFI 90 and Symphony Plus communication backplanes.\u003c\/span\u003e\u003cspan class=\"\"\u003e This Bus Monitor module functions as a critical auditing tool,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing engineers and maintenance personnel with deep visibility into the Control Bus and Slave Expander Bus traffic.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its primary role is to intercept and analyze data packets without interfering with active control processes,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it essential for identifying communication bottlenecks,\u003c\/span\u003e\u003cspan class=\"\"\u003e protocol errors,\u003c\/span\u003e\u003cspan class=\"\"\u003e or hardware collisions within a module mounting unit.\u003c\/span\u003e\u003cspan class=\"\"\u003e By monitoring signal integrity at the physical and data link layers,\u003c\/span\u003e\u003cspan class=\"\"\u003e the 6637830G1 ensures that the deterministic nature of the Distributed Control System (DCS) remains uncompromised during complex plant operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 6637830G1\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Role\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e System Bus Analysis and Monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eBus Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Harmony Control Bus \/ Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard INFI 90 Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Source\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Powered via the system backplane (+5 VDC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Front-panel diagnostic ports for external analyzer connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eStorage Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e -40 to 85 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003ePassive Monitoring Architecture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Observes all backplane traffic in a non-intrusive manner,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that primary control logic execution is never delayed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eReal-Time Fault Detection\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Identifies intermittent communication failures and protocol timing violations that can lead to system-wide resets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eStreamlined Troubleshooting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Minimizes plant downtime by pinpointing the specific module or bus segment responsible for data integrity issues.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Speed Data Capture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Engineered to keep pace with the high-frequency packet rates characteristic of the INFI 90 Cnet and local bus environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eModular Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Standard card-edge design allows for rapid insertion into any vacant slot within the Harmony rack for immediate diagnostic sessions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Hardening\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to the rigorous standards of power generation facilities,\u003c\/span\u003e\u003cspan\u003e providing reliable operation in high-EMI environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095910215989,"sku":"6637830G1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/6637830G1__1.jpg?v=1766660669"},{"product_id":"abb-bailey-atmb-01c-temperature-measurement-interface-board","title":"ABB Bailey ATMB-01C Temperature Measurement Interface Board","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eATMB-01C\u003c\/strong\u003e is a high-precision temperature measuring board engineered to provide accurate thermal data acquisition for industrial control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This specialized circuit board acts as an interface between field-side temperature sensors and the primary control logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that analog thermal readings are converted and stabilized for processing.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is primarily utilized in environments requiring rigorous thermal monitoring,\u003c\/span\u003e\u003cspan class=\"\"\u003e such as motor windings,\u003c\/span\u003e\u003cspan class=\"\"\u003e bearings,\u003c\/span\u003e\u003cspan class=\"\"\u003e or heat exchange processes within power generation and chemical manufacturing facilities.\u003c\/span\u003e\u003cspan class=\"\"\u003e The ATMB-01C is designed to handle sensitive millivolt signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing the necessary filtering and amplification to maintain data integrity in electrically noisy industrial settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ATMB-01C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Temperature Measuring Board\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports standard RTD and Thermocouple profiles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Conditioning\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated high-frequency noise filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Direct internal mounting for drive or controller enclosures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eCalibration\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Factory-calibrated for linear temperature response\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eRelative Humidity\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003ePrecision Signal Conversion\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Optimized for low-level signal detection,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing high-resolution temperature feedback to the DCS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eCold Junction Compensation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features integrated circuitry to ensure measurement accuracy across varying ambient terminal temperatures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eGalvanic Isolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Protects internal control electronics from field-side electrical surges and ground loop interference.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eThermal Stability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built with high-grade components that resist drift,\u003c\/span\u003e\u003cspan\u003e ensuring long-term measurement consistency without frequent recalibration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eCompact Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed with a space-saving footprint for seamless installation into existing ABB drive assemblies or control modules.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eRobust Hardware Architecture\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Specifically hardened against the vibration and electromagnetic profiles found in heavy industrial motor control centers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095922766133,"sku":"ATMB-01C","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/ATMB-01C.jpg?v=1766660826"},{"product_id":"abb-bailey-innis11-infi-net-network-interface-slave-module","title":"ABB Bailey INNIS11 Infi-Net Network Interface Slave Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eINNIS11\u003c\/strong\u003e is a high-speed communication module designed to facilitate the transfer of data between the plant-wide Infi-Net (Cnet) loop and the local Harmony control bus.\u003c\/span\u003e\u003cspan class=\"\"\u003e Serving as the primary interface for distributed control processors,\u003c\/span\u003e\u003cspan class=\"\"\u003e this module manages the buffering and routing of network traffic to ensure that control instructions and process variables are delivered with deterministic precision.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is a critical component for the Symphony Plus and INFI 90 architectures,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing the essential link required for multi-node synchronization and system-wide data transparency.\u003c\/span\u003e\u003cspan class=\"\"\u003e The INNIS11 is engineered for continuous duty in industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e offering high throughput and robust error-checking capabilities to maintain the integrity of the DCS communication backbone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INNIS11\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Interface Slave (NIS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eNetwork Protocol\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Infi-Net (Cnet) Proprietary Loop\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eLocal Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed expander bus connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Occupies one slot in a standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC at 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 Amps (Typical)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eData Transfer Rate\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports standard Infi-Net 2.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 Mbps or 10 Mbps rates\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eIntelligent Data Routing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Independently manages network layer protocols,\u003c\/span\u003e\u003cspan class=\"\"\u003e allowing the main processor module to focus exclusively on control strategy execution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Fully compatible with redundant hardware configurations to ensure uninterrupted network access during module maintenance or failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eOn-Board Buffer Memory\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Features high-speed RAM to manage burst data traffic,\u003c\/span\u003e\u003cspan class=\"\"\u003e preventing packet loss during peak network utilization.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\" class=\"\"\u003eHardware Self-Testing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Performs comprehensive power-up and runtime diagnostics,\u003c\/span\u003e\u003cspan\u003e reporting hardware health status directly to the system operator.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eDeterministic Performance\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Maintains consistent communication timing cycles,\u003c\/span\u003e\u003cspan\u003e which is essential for synchronized control in power generation and large process loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eBackward Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed to integrate seamlessly with both legacy INFI 90 hardware and modern Symphony Plus system components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095934267701,"sku":"INNIS11","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INNIS11.jpg?v=1766661182"},{"product_id":"abb-bailey-imrio02-remote-i-o-slave-communication-module","title":"ABB Bailey IMRIO02 Remote I\/O Slave Communication Module","description":"\u003ch3 data-path-to-node=\"2\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003eThe ABB \u003cstrong\u003eIMRIO02\u003c\/strong\u003e is a high-performance remote I\/O slave module designed for the Bailey INFI 90 and Symphony Plus distributed control systems. This module functions as a critical communication link that allows a master controller to interface with I\/O modules located in remote cabinets. By utilizing the IMRIO02, industrial facilities can extend their control architecture over longer distances without the need for extensive hardwiring, significantly reducing installation costs. It manages the serialization and de-serialization of data packets across the remote I\/O link, ensuring that field data is transmitted with the speed and determinism required for real-time process regulation. This module is essential for large-scale decentralized automation in power plants, water treatment facilities, and refineries.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e: ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\"\u003eModel Number\u003c\/b\u003e: IMRIO02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\"\u003eProduct Series\u003c\/b\u003e: INFI 90 \/ Symphony Plus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\"\u003eModule Type\u003c\/b\u003e: Remote I\/O Slave Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003eCommunication Link\u003c\/b\u003e: High-speed serial remote I\/O bus\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\"\u003eCompatibility\u003c\/b\u003e: Works with IMHSS, IMASO, and IMDSO series modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\"\u003eMounting\u003c\/b\u003e: Standard Module Mounting Unit (MMU) slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\"\u003ePower Consumption\u003c\/b\u003e: 5 VDC via system backplane\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\"\u003eOperating Temperature\u003c\/b\u003e: 0 to 70 degrees Celsius\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\"\u003eRelative Humidity\u003c\/b\u003e: 5% to 95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\"\u003eExtended Control Reach\u003c\/b\u003e: Facilitates the distribution of I\/O racks across large physical plant areas while maintaining a centralized control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\"\u003eDeterministic Data Exchange\u003c\/b\u003e: Optimized for low-latency transmission, ensuring that remote signals are processed within the necessary control loop scan times.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSlave Bus Management\u003c\/b\u003e: Efficiently coordinates data traffic between the remote link and the local expander bus within the satellite rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eSystem Redundancy Support\u003c\/b\u003e: Designed to operate in redundant configurations to provide high system availability and fault tolerance for critical loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eIntegrated Diagnostics\u003c\/b\u003e: Features comprehensive self-test routines and status LEDs that provide immediate feedback on the health of the remote communication link.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eHardware Robustness\u003c\/b\u003e: Specifically built to withstand the electromagnetic interference (EMI) often encountered in long-distance industrial cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095961760053,"sku":"IMRIO02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMRIO02-removebg-preview.png?v=1766661460"},{"product_id":"abb-bailey-immfp12-multi-function-processor-control-module","title":"ABB Bailey IMMFP12 Multi-Function Processor Control Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMMFP12\u003c\/strong\u003e is a high-capacity processing engine designed as the central intelligence unit for the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This multi-function processor is engineered to execute complex control logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e ranging from simple PID loops to sophisticated sequential and batch control strategies.\u003c\/span\u003e\u003cspan class=\"\"\u003e By utilizing a dedicated microprocessor architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMMFP12 manages all data acquisition from I\/O modules via the slave expander bus and communicates with the broader plant loop through network interface modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is the primary vehicle for running user-defined functional block programs,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing the computational power necessary for the stable and efficient operation of power plants,\u003c\/span\u003e\u003cspan class=\"\"\u003e refineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e and large-scale manufacturing processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMMFP12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eProcessor Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed 32-bit architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInstruction Set\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports comprehensive function block library\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Harmony Control Bus and Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMemory\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated Non-volatile RAM and Flash for logic storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single-width module for standard rack assembly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Supply\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (backplane integrated)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Environment\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eAdvanced Logic Execution\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Capable of processing thousands of function blocks per second to maintain tight control over volatile process variables.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Management\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports high-availability configurations where a secondary module can take over control seamlessly upon hardware failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003ePeer-to-Peer Networking\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Facilitates direct data exchange with other controllers on the Infi-Net loop for coordinated plant-wide strategies.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eComprehensive Self-Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously monitors internal memory,\u003c\/span\u003e\u003cspan\u003e processing cycles,\u003c\/span\u003e\u003cspan\u003e and bus integrity to ensure operational safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eDynamic Configuration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Allows for logic adjustments and parameter tuning without requiring a total system shutdown.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Reliability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Hardened against electromagnetic interference and high-vibration conditions common in industrial control rooms.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095968444725,"sku":"IMMFP12","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMMFP12.jpg?v=1766661666"},{"product_id":"abb-bailey-imaso11-analog-output-module","title":"ABB Bailey IMASO11 Analog Output Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB IMASO11 is a high-precision analog output module designed for use within the Bailey INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e Functioning as a slave module on the expander bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e it converts digital commands from the primary controller into continuous analog signals required to drive field equipment.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is essential for the precise modulation of control valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e variable speed drives,\u003c\/span\u003e\u003cspan class=\"\"\u003e and other positioning actuators.\u003c\/span\u003e\u003cspan class=\"\"\u003e The IMASO11 is engineered to maintain high signal integrity over 14 independent channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that process variables are adjusted with the accuracy necessary for complex industrial loops.\u003c\/span\u003e\u003cspan class=\"\"\u003e It features robust isolation and diagnostic capabilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e making it a reliable choice for critical control applications in power generation,\u003c\/span\u003e\u003cspan class=\"\"\u003e water treatment,\u003c\/span\u003e\u003cspan class=\"\"\u003e and chemical processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMASO11\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eOutput Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Analog Slave Output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eChannel Density\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 14 Isolated Output Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Range\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 4-20 mA DC (Standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eResolution\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 12-bit Digital-to-Analog conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Slave Expander Bus Interface\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC via system backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eMulti-Channel Precision\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Manages 14 discrete analog outputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing a high-density solution for multi-valve control from a single rack slot.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eGalvanic Signal Isolation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Protects the system's internal logic from field-side electrical interference and ground loop issues.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Response\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan\u003e Optimized for real-time control,\u003c\/span\u003e\u003cspan\u003e providing consistent signal updates in synchronization with the master processor's scan cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eIntegrated Self-Monitoring\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continuously audits the status of internal digital-to-analog converters and reports hardware health to the HMI.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eFailure Mode Configuration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Allows for the pre-definition of output states (Hold Last Value or Reset) in the event of a communication loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eIndustrial Hardening\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Built to withstand the rigorous electromagnetic and thermal conditions typical of heavy industrial control cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095970771253,"sku":"IMASO11","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMASO11.jpg?v=1766661822"},{"product_id":"abb-bailey-innis21-infi-net-network-interface-slave-module","title":"ABB Bailey INNIS21 Infi-Net Network Interface Slave Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB\u003cstrong\u003e INNIS21\u003c\/strong\u003e is a high-performance network interface component specifically engineered for the INFI 90 and Symphony Plus distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e Functioning as a specialized communications processor,\u003c\/span\u003e\u003cspan class=\"\"\u003e this module serves as the essential bridge between the high-speed Infi-Net (Cnet) plant loop and the local controller backplane.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its primary objective is to manage the complex protocols of the network layer,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that process data,\u003c\/span\u003e\u003cspan class=\"\"\u003e control commands,\u003c\/span\u003e\u003cspan class=\"\"\u003e and system messages are synchronized across different nodes without burdening the main control processor.\u003c\/span\u003e\u003cspan class=\"\"\u003e The INNIS21 provides the deterministic,\u003c\/span\u003e\u003cspan class=\"\"\u003e real-time data throughput required for large-scale industrial automation environments where network reliability is paramount.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INNIS21\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eComponent Type\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Interface Slave (NIS)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eConnectivity Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Infi-Net (Cnet) to Harmony Control Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eData Transfer Protocol\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Proprietary Synchronous Network Protocol\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (sourced via system backplane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eSlot Consumption\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single slot in standard Module Mounting Unit (MMU)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature Range\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eDiagnostic Indicators\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Front-panel LED array for network status monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eAdvanced Network Routing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Efficiently directs traffic between the plant-wide loop and local rack controllers to ensure low-latency data availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundant Loop Capability\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Built to support dual-path communication architectures,\u003c\/span\u003e\u003cspan class=\"\"\u003e providing automatic failover to maintain system uptime during network cable damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eDedicated Protocol Handling\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Offloads all network management tasks from the processing module,\u003c\/span\u003e\u003cspan\u003e optimizing the CPU cycles available for control logic execution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eAutonomous Error Correction\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Implements hardware-based checksums and parity checks to guarantee the integrity of data packets transmitted across the industrial network.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eHardware Compatibility\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed for seamless integration into both legacy Bailey INFI 90 racks and modern Symphony Plus hardware cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eOn-Board Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Continually performs internal health checks and monitors network signal quality,\u003c\/span\u003e\u003cspan\u003e providing immediate notification of potential communication bottlenecks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095973654837,"sku":"INNIS21","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INNIS21.jpg?v=1766662049"},{"product_id":"abb-bailey-innpm12-infi-net-network-processing-module","title":"ABB Bailey INNPM12 Infi-Net Network Processing Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eINNPM12\u003c\/strong\u003e is a high-performance network processing unit designed to manage communication within the Bailey INFI 90 and Symphony Plus distributed control system (DCS) architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module serves as the primary intelligence for an Infi-Net node,\u003c\/span\u003e\u003cspan class=\"\"\u003e coordinating the flow of process data,\u003c\/span\u003e\u003cspan class=\"\"\u003e control signals,\u003c\/span\u003e\u003cspan class=\"\"\u003e and diagnostic information between the plant-wide loop and local controller modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e By working in tandem with a Network Interface Slave (NIS) module,\u003c\/span\u003e\u003cspan class=\"\"\u003e the INNPM12 facilitates the sophisticated routing and protocol translation necessary for large-scale industrial networking.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is engineered to maintain deterministic communication timing,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring that time-critical process variables are updated across the system without latency,\u003c\/span\u003e\u003cspan class=\"\"\u003e which is vital for the safe and efficient operation of power and process industries.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INNPM12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Role\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Network Communication Processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eProcessor Architecture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e High-speed dedicated microprocessor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface Compatibility\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Harmony Control Bus \/ Infi-Net (Cnet)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMemory\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e On-board RAM and Non-volatile Flash memory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU) occupancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Consumption\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (Typical) via backplane\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eNode Intelligence\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Acts as the master controller for an Infi-Net node,\u003c\/span\u003e\u003cspan class=\"\"\u003e managing all local and global data exchange requests.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eDeterministic Throughput\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Specifically optimized to handle high-frequency data packets while ensuring consistent transmission intervals across the DCS loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundant Configuration Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports primary\/backup pairing to provide seamless network failover and maximum system availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eAdvanced Protocol Translation\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Handles complex network layer tasks,\u003c\/span\u003e\u003cspan\u003e offloading processing requirements from the main multi-function processors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eComprehensive System Auditing\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Includes built-in diagnostic routines that monitor node health and communication link integrity in real-time.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eScalable Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Compatible with various generations of Bailey hardware,\u003c\/span\u003e\u003cspan\u003e allowing for gradual system upgrades and network expansions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095973916981,"sku":"INNPM12","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INNPM12.jpg?v=1766662227"},{"product_id":"abb-bailey-immfp02-distributed-control-multi-function-processor","title":"ABB Bailey IMMFP02 Distributed Control Multi-Function Processor","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMMFP02\u003c\/strong\u003e is a high-reliability central processing unit designed for the Bailey INFI 90 distributed control system (DCS).\u003c\/span\u003e\u003cspan class=\"\"\u003e This module serves as the primary execution engine for complex automation strategies,\u003c\/span\u003e\u003cspan class=\"\"\u003e managing data acquisition and control calculations across the system backplane.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is engineered to process a wide array of function blocks,\u003c\/span\u003e\u003cspan class=\"\"\u003e enabling it to handle continuous control,\u003c\/span\u003e\u003cspan class=\"\"\u003e batch processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e and sequential logic simultaneously.\u003c\/span\u003e\u003cspan class=\"\"\u003e By interfacing with various I\/O modules via the slave expander bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e the IMMFP02 maintains deterministic control over industrial plant equipment.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its robust architecture is specifically tailored for the demanding environments of power generation,\u003c\/span\u003e\u003cspan class=\"\"\u003e pulp and paper,\u003c\/span\u003e\u003cspan class=\"\"\u003e and petrochemical processing facilities where system uptime is critical.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e IMMFP02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eProcessor Function\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Multi-Function Control Processor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eLogic Execution\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Supports extensive Function Block programming\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication Interface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Control Bus and Slave Expander Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eMemory Architecture\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrated RAM with battery backup for database retention\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eInstallation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Single-slot module mounting unit occupancy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Requirements\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e +5 VDC (Backplane supplied)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eHigh-Speed Logic Processing\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Delivers the computational power required for high-frequency PID loops and complex logic interlocking.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundant Operation Support\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Can be configured in a primary\/backup pair to ensure continuous process control in the event of a module hardware failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\"\u003eSeamless System Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Facilitates direct communication with other Harmony controllers and network modules via the high-speed plant loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eOn-Board Fault Detection\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features advanced self-diagnostic routines that verify the integrity of the CPU,\u003c\/span\u003e\u003cspan\u003e memory,\u003c\/span\u003e\u003cspan\u003e and bus communications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eNon-Volatile Storage\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Ensures that critical control configurations and tuning parameters are preserved during power interruptions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eField-Proven Reliability\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Designed with industrial-grade components to resist electromagnetic interference and thermal stress in control room environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095974932789,"sku":"IMMFP02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMMFP02-removebg-preview.png?v=1766662421"},{"product_id":"abb-bailey-tas01-automatic-synchronizer-control-module","title":"ABB Bailey TAS01 Automatic Synchronizer Control Module","description":"\u003ch3 data-path-to-node=\"2\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"3\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eTAS01 \u003c\/strong\u003eis a precision-engineered automatic synchronization module designed for the Bailey INFI 90 and Symphony Plus control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its primary function is to manage the safe and efficient paralleling of AC generators with the main power grid or other live bus systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e The module continuously monitors the voltage,\u003c\/span\u003e\u003cspan class=\"\"\u003e frequency,\u003c\/span\u003e\u003cspan class=\"\"\u003e and phase angle of both the incoming source and the energized bus,\u003c\/span\u003e\u003cspan class=\"\"\u003e calculating the optimal moment to issue a circuit breaker closure command.\u003c\/span\u003e\u003cspan class=\"\"\u003e By automating the synchronization process,\u003c\/span\u003e\u003cspan class=\"\"\u003e the TAS01 prevents significant mechanical stress and electrical surges associated with out-of-phase closing,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring the stability of power generation assets.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is widely utilized in hydroelectric,\u003c\/span\u003e\u003cspan class=\"\"\u003e steam turbine,\u003c\/span\u003e\u003cspan class=\"\"\u003e and industrial co-generation facilities where reliable grid synchronization is a critical operational requirement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"4\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e TAS01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Series\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e INFI 90 \/ Symphony Plus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eFunctional Role\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Automatic Synchronizer \/ Generator Control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Voltage Monitoring\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Dual AC voltage inputs (Generator and Bus)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eFrequency Range\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 50\/60 Hz nominal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003ePhase Angle Tolerance\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e User-configurable for precise closure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eInterface\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Integrates with Multi-Function Processor (MFP) via expander bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003eMounting\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Standard Module Mounting Unit (MMU) slot\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eOperating Temperature\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e 0 to 70 degrees Celsius\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"7\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,0,0\"\u003e\u003cb data-path-to-node=\"7,0,0\" data-index-in-node=\"0\" class=\"\"\u003eAutomated Phase Matching\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Synchronizes generators by adjusting speed and voltage regulators automatically to match grid parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,1,0\"\u003e\u003cb data-path-to-node=\"7,1,0\" data-index-in-node=\"0\" class=\"\"\u003eFail-Safe Operation\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Incorporates advanced synch-check logic to prevent breaker closure if parameters fall outside of safe safety limits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,2,0\"\u003e\u003cb data-path-to-node=\"7,2,0\" data-index-in-node=\"0\" class=\"\"\u003ePrecise Timing Logic\u003c\/b\u003e\u003cspan class=\"\"\u003e:\u003c\/span\u003e\u003cspan class=\"\"\u003e Accounts for circuit breaker closure time delays to ensure exact zero-degree phase coincidence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,3,0\"\u003e\u003cb data-path-to-node=\"7,3,0\" data-index-in-node=\"0\"\u003eHigh-Speed Processing\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Real-time signal analysis of AC waveforms to provide instantaneous correction signals to the governor and exciter systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,4,0\"\u003e\u003cb data-path-to-node=\"7,4,0\" data-index-in-node=\"0\"\u003eIntegrated Diagnostics\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Features internal monitoring to detect signal loss or hardware failure,\u003c\/span\u003e\u003cspan\u003e immediately inhibiting synchronization if a fault is found.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"7,5,0\"\u003e\u003cb data-path-to-node=\"7,5,0\" data-index-in-node=\"0\"\u003eSeamless DCS Integration\u003c\/b\u003e\u003cspan\u003e:\u003c\/span\u003e\u003cspan\u003e Fully compatible with the Harmony control architecture,\u003c\/span\u003e\u003cspan\u003e allowing for remote monitoring and setpoint adjustment via the HMI.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52095976472885,"sku":"TAS01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/TAS01-removebg-preview.png?v=1766662599"},{"product_id":"abb-imfec11-bailey-infi-90-analog-input-fsk-slave-module","title":"ABB IMFEC11 Bailey INFI 90 Analog Input \/ FSK Slave Module","description":"\u003ch3 data-start=\"215\" data-end=\"236\"\u003e\u003cstrong data-start=\"219\" data-end=\"234\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"237\" data-end=\"684\"\u003eThe ABB\u003cstrong data-start=\"241\" data-end=\"256\"\u003e IMFEC11\u003c\/strong\u003e Bailey INFI 90 Analog Input \/ FSK Slave Module is a high-performance analog signal interface designed for precision data acquisition and control. It converts analog signals into digital data for seamless integration within the Bailey INFI 90 Distributed Control System. Engineered with industrial-grade components, the module ensures reliable operation and accurate signal processing under demanding environmental conditions.\u003c\/p\u003e\n\u003ch3 data-start=\"686\" data-end=\"710\"\u003e\u003cstrong data-start=\"690\" data-end=\"708\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"711\" data-end=\"1330\"\u003e\n\u003cli data-start=\"711\" data-end=\"729\"\u003e\n\u003cp data-start=\"713\" data-end=\"729\"\u003e\u003cstrong data-start=\"713\" data-end=\"723\"\u003eBrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"730\" data-end=\"756\"\u003e\n\u003cp data-start=\"732\" data-end=\"756\"\u003e\u003cstrong data-start=\"732\" data-end=\"742\"\u003eModel:\u003c\/strong\u003e IMFEC11\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"757\" data-end=\"805\"\u003e\n\u003cp data-start=\"759\" data-end=\"805\"\u003e\u003cstrong data-start=\"759\" data-end=\"784\"\u003eSystem Compatibility:\u003c\/strong\u003e Bailey INFI 90 DCS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"806\" data-end=\"864\"\u003e\n\u003cp data-start=\"808\" data-end=\"864\"\u003e\u003cstrong data-start=\"808\" data-end=\"821\"\u003eFunction:\u003c\/strong\u003e Analog input and FSK slave communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"865\" data-end=\"918\"\u003e\n\u003cp data-start=\"867\" data-end=\"918\"\u003e\u003cstrong data-start=\"867\" data-end=\"882\"\u003eInput Type:\u003c\/strong\u003e Current or voltage analog signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"960\"\u003e\n\u003cp data-start=\"921\" data-end=\"960\"\u003e\u003cstrong data-start=\"921\" data-end=\"936\"\u003eResolution:\u003c\/strong\u003e 12-bit A\/D conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"961\" data-end=\"1021\"\u003e\n\u003cp data-start=\"963\" data-end=\"1021\"\u003e\u003cstrong data-start=\"963\" data-end=\"990\"\u003eCommunication Protocol:\u003c\/strong\u003e FSK (Frequency Shift Keying)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1087\"\u003e\n\u003cp data-start=\"1024\" data-end=\"1087\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1042\"\u003eSampling Rate:\u003c\/strong\u003e Optimized for real-time process monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1088\" data-end=\"1124\"\u003e\n\u003cp data-start=\"1090\" data-end=\"1124\"\u003e\u003cstrong data-start=\"1090\" data-end=\"1107\"\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1125\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1127\" data-end=\"1168\"\u003e\u003cstrong data-start=\"1127\" data-end=\"1153\"\u003eOperating Temperature:\u003c\/strong\u003e 0°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1226\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1226\"\u003e\u003cstrong data-start=\"1171\" data-end=\"1189\"\u003eMounting Type:\u003c\/strong\u003e Plug-in module for INFI 90 chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1227\" data-end=\"1264\"\u003e\n\u003cp data-start=\"1229\" data-end=\"1264\"\u003e\u003cstrong data-start=\"1229\" data-end=\"1244\"\u003eDimensions:\u003c\/strong\u003e 270 × 170 × 25 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1265\" data-end=\"1296\"\u003e\n\u003cp data-start=\"1267\" data-end=\"1296\"\u003e\u003cstrong data-start=\"1267\" data-end=\"1278\"\u003eWeight:\u003c\/strong\u003e Approx. 0.45 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1297\" data-end=\"1330\"\u003e\n\u003cp data-start=\"1299\" data-end=\"1330\"\u003e\u003cstrong data-start=\"1299\" data-end=\"1310\"\u003eOrigin:\u003c\/strong\u003e Made in Singapore\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1332\" data-end=\"1350\"\u003e\u003cstrong data-start=\"1336\" data-end=\"1348\"\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1351\" data-end=\"1891\"\u003e\n\u003cli data-start=\"1351\" data-end=\"1442\"\u003e\n\u003cp data-start=\"1353\" data-end=\"1442\"\u003e\u003cstrong data-start=\"1353\" data-end=\"1372\"\u003eHigh Precision:\u003c\/strong\u003e Provides accurate analog-to-digital conversion for process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1443\" data-end=\"1544\"\u003e\n\u003cp data-start=\"1445\" data-end=\"1544\"\u003e\u003cstrong data-start=\"1445\" data-end=\"1472\"\u003eReliable Communication:\u003c\/strong\u003e FSK slave interface ensures stable and noise-resistant data exchange.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1545\" data-end=\"1632\"\u003e\n\u003cp data-start=\"1547\" data-end=\"1632\"\u003e\u003cstrong data-start=\"1547\" data-end=\"1572\"\u003eSeamless Integration:\u003c\/strong\u003e Fully compatible with Bailey INFI 90 system architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1633\" data-end=\"1726\"\u003e\n\u003cp data-start=\"1635\" data-end=\"1726\"\u003e\u003cstrong data-start=\"1635\" data-end=\"1664\"\u003eSelf-Diagnostic Function:\u003c\/strong\u003e Built-in monitoring enhances system reliability and uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1727\" data-end=\"1806\"\u003e\n\u003cp data-start=\"1729\" data-end=\"1806\"\u003e\u003cstrong data-start=\"1729\" data-end=\"1747\"\u003eRugged Design:\u003c\/strong\u003e Designed to perform under harsh industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1807\" data-end=\"1891\"\u003e\n\u003cp data-start=\"1809\" data-end=\"1891\"\u003e\u003cstrong data-start=\"1809\" data-end=\"1830\"\u003eEasy Maintenance:\u003c\/strong\u003e Modular structure simplifies installation and replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096812024117,"sku":"IMFEC11","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMFEC11.png?v=1766712022"},{"product_id":"abb-iisac01-analog-control-station-industrial-control-interface","title":"ABB IISAC01 Analog Control Station Industrial Control Interface","description":"\u003ch3 data-start=\"207\" data-end=\"228\"\u003e\u003cstrong data-start=\"211\" data-end=\"226\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"229\" data-end=\"734\"\u003eThe \u003cstrong data-start=\"233\" data-end=\"248\"\u003eABB IISAC01\u003c\/strong\u003e Analog Control Station is a robust control interface designed for industrial automation systems, offering reliable and accurate control over analog devices. This station allows operators to manage process control equipment, providing real-time feedback and manual adjustments in critical systems. With a durable design and intuitive interface, the \u003cstrong data-start=\"597\" data-end=\"608\"\u003eIISAC01\u003c\/strong\u003e is engineered to handle demanding environments, ensuring continuous performance and ease of use in industrial applications.\u003c\/p\u003e\n\u003ch3 data-start=\"736\" data-end=\"760\"\u003e\u003cstrong data-start=\"740\" data-end=\"758\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"761\" data-end=\"1412\"\u003e\n\u003cli data-start=\"761\" data-end=\"779\"\u003e\n\u003cp data-start=\"763\" data-end=\"779\"\u003e\u003cstrong data-start=\"763\" data-end=\"773\"\u003eBrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"780\" data-end=\"806\"\u003e\n\u003cp data-start=\"782\" data-end=\"806\"\u003e\u003cstrong data-start=\"782\" data-end=\"792\"\u003eModel:\u003c\/strong\u003e \u003cstrong data-start=\"793\" data-end=\"804\"\u003eIISAC01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"807\" data-end=\"856\"\u003e\n\u003cp data-start=\"809\" data-end=\"856\"\u003e\u003cstrong data-start=\"809\" data-end=\"826\"\u003eControl Type:\u003c\/strong\u003e Analog input\/output control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"932\"\u003e\n\u003cp data-start=\"859\" data-end=\"932\"\u003e\u003cstrong data-start=\"859\" data-end=\"877\"\u003eFunctionality:\u003c\/strong\u003e Real-time operator control for industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"933\" data-end=\"988\"\u003e\n\u003cp data-start=\"935\" data-end=\"988\"\u003e\u003cstrong data-start=\"935\" data-end=\"950\"\u003eInput Type:\u003c\/strong\u003e Analog signals (voltage or current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"989\" data-end=\"1035\"\u003e\n\u003cp data-start=\"991\" data-end=\"1035\"\u003e\u003cstrong data-start=\"991\" data-end=\"1004\"\u003eMounting:\u003c\/strong\u003e Wall or panel-mounted design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1036\" data-end=\"1105\"\u003e\n\u003cp data-start=\"1038\" data-end=\"1105\"\u003e\u003cstrong data-start=\"1038\" data-end=\"1055\"\u003ePower Supply:\u003c\/strong\u003e 24 VDC or AC supply, depending on configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1106\" data-end=\"1147\"\u003e\n\u003cp data-start=\"1108\" data-end=\"1147\"\u003e\u003cstrong data-start=\"1108\" data-end=\"1130\"\u003eTemperature Range:\u003c\/strong\u003e –10°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1148\" data-end=\"1185\"\u003e\n\u003cp data-start=\"1150\" data-end=\"1185\"\u003e\u003cstrong data-start=\"1150\" data-end=\"1165\"\u003eDimensions:\u003c\/strong\u003e 250 × 180 × 90 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1186\" data-end=\"1216\"\u003e\n\u003cp data-start=\"1188\" data-end=\"1216\"\u003e\u003cstrong data-start=\"1188\" data-end=\"1199\"\u003eWeight:\u003c\/strong\u003e Approx. 2.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1217\" data-end=\"1277\"\u003e\n\u003cp data-start=\"1219\" data-end=\"1277\"\u003e\u003cstrong data-start=\"1219\" data-end=\"1240\"\u003eProtection Class:\u003c\/strong\u003e IP65 for dust and water resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1278\" data-end=\"1357\"\u003e\n\u003cp data-start=\"1280\" data-end=\"1357\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1307\"\u003eCommunication Protocol:\u003c\/strong\u003e No communication interface (local control only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1358\" data-end=\"1412\"\u003e\n\u003cp data-start=\"1360\" data-end=\"1412\"\u003e\u003cstrong data-start=\"1360\" data-end=\"1374\"\u003eMaterials:\u003c\/strong\u003e High-grade steel or durable plastic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1414\" data-end=\"1432\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1430\"\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1433\" data-end=\"2123\"\u003e\n\u003cli data-start=\"1433\" data-end=\"1532\"\u003e\n\u003cp data-start=\"1435\" data-end=\"1532\"\u003e\u003cstrong data-start=\"1435\" data-end=\"1463\"\u003eUser-Friendly Interface:\u003c\/strong\u003e Easy-to-use analog controls for manual adjustments and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1533\" data-end=\"1647\"\u003e\n\u003cp data-start=\"1535\" data-end=\"1647\"\u003e\u003cstrong data-start=\"1535\" data-end=\"1560\"\u003eReliable Performance:\u003c\/strong\u003e Engineered for stability in harsh industrial environments with long-term durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1648\" data-end=\"1748\"\u003e\n\u003cp data-start=\"1650\" data-end=\"1748\"\u003e\u003cstrong data-start=\"1650\" data-end=\"1675\"\u003eFlexible Integration:\u003c\/strong\u003e Compatible with most analog control systems and automation frameworks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1749\" data-end=\"1890\"\u003e\n\u003cp data-start=\"1751\" data-end=\"1890\"\u003e\u003cstrong data-start=\"1751\" data-end=\"1775\"\u003eRobust Construction:\u003c\/strong\u003e Designed with an IP65 rating for protection against dust and water, making it suitable for factory environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1891\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1893\" data-end=\"2005\"\u003e\u003cstrong data-start=\"1893\" data-end=\"1918\"\u003eMaintenance Friendly:\u003c\/strong\u003e Easy to install and replace with minimal downtime, enhancing operational efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2006\" data-end=\"2123\"\u003e\n\u003cp data-start=\"2008\" data-end=\"2123\"\u003e\u003cstrong data-start=\"2008\" data-end=\"2031\"\u003eReal-Time Feedback:\u003c\/strong\u003e Provides real-time control over process variables for accurate adjustments and operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096840728885,"sku":"IISAC01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IISAC01.jpg?v=1766712424"},{"product_id":"abb-incit01-infi-net-to-computer-transfer-module-industrial-data-communication","title":"ABB INCIT01 INFI-Net to Computer Transfer Module – Industrial Data Communication","description":"\u003ch3 data-start=\"150\" data-end=\"171\"\u003e\u003cstrong data-start=\"154\" data-end=\"169\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"172\" data-end=\"703\"\u003eThe\u003cstrong\u003e \u003c\/strong\u003eABB\u003cstrong data-start=\"176\" data-end=\"191\"\u003e INCIT01\u003c\/strong\u003e INFI-Net to Computer Transfer Module is designed to enable seamless communication between INFI-Net networks and computer systems in industrial environments. This high-performance module acts as a bridge, allowing efficient and secure data transfer from distributed control systems (DCS) to PC-based platforms for real-time monitoring and control. With advanced communication protocols, the INCIT01 ensures that critical data is transferred reliably, supporting effective process management and automation.\u003c\/p\u003e\n\u003ch3 data-start=\"705\" data-end=\"729\"\u003e\u003cstrong data-start=\"709\" data-end=\"727\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"730\" data-end=\"1353\"\u003e\n\u003cli data-start=\"730\" data-end=\"748\"\u003e\n\u003cp data-start=\"732\" data-end=\"748\"\u003e\u003cstrong data-start=\"732\" data-end=\"742\"\u003eBrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"749\" data-end=\"775\"\u003e\n\u003cp data-start=\"751\" data-end=\"775\"\u003e\u003cstrong data-start=\"751\" data-end=\"761\"\u003eModel:\u003c\/strong\u003e\u003cstrong\u003e \u003c\/strong\u003eINCIT01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"776\" data-end=\"810\"\u003e\n\u003cp data-start=\"778\" data-end=\"810\"\u003e\u003cstrong data-start=\"778\" data-end=\"787\"\u003eType:\u003c\/strong\u003e Data transfer module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"811\" data-end=\"888\"\u003e\n\u003cp data-start=\"813\" data-end=\"888\"\u003e\u003cstrong data-start=\"813\" data-end=\"831\"\u003eFunctionality:\u003c\/strong\u003e Facilitates INFI-Net communication to computer systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"889\" data-end=\"961\"\u003e\n\u003cp data-start=\"891\" data-end=\"961\"\u003e\u003cstrong data-start=\"891\" data-end=\"918\"\u003eCommunication Protocol:\u003c\/strong\u003e INFI-Net, supports multiple data formats\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"962\" data-end=\"1043\"\u003e\n\u003cp data-start=\"964\" data-end=\"1043\"\u003e\u003cstrong data-start=\"964\" data-end=\"988\"\u003eData Transfer Speed:\u003c\/strong\u003e High-speed communication for real-time data handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1044\" data-end=\"1072\"\u003e\n\u003cp data-start=\"1046\" data-end=\"1072\"\u003e\u003cstrong data-start=\"1046\" data-end=\"1063\"\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1073\" data-end=\"1118\"\u003e\n\u003cp data-start=\"1075\" data-end=\"1118\"\u003e\u003cstrong data-start=\"1075\" data-end=\"1101\"\u003eOperating Temperature:\u003c\/strong\u003e –10°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1119\" data-end=\"1156\"\u003e\n\u003cp data-start=\"1121\" data-end=\"1156\"\u003e\u003cstrong data-start=\"1121\" data-end=\"1136\"\u003eDimensions:\u003c\/strong\u003e 150 × 120 × 45 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1157\" data-end=\"1187\"\u003e\n\u003cp data-start=\"1159\" data-end=\"1187\"\u003e\u003cstrong data-start=\"1159\" data-end=\"1170\"\u003eWeight:\u003c\/strong\u003e Approx. 0.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1188\" data-end=\"1233\"\u003e\n\u003cp data-start=\"1190\" data-end=\"1233\"\u003e\u003cstrong data-start=\"1190\" data-end=\"1203\"\u003eMounting:\u003c\/strong\u003e Panel or DIN rail mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1234\" data-end=\"1277\"\u003e\n\u003cp data-start=\"1236\" data-end=\"1277\"\u003e\u003cstrong data-start=\"1236\" data-end=\"1257\"\u003eProtection Class:\u003c\/strong\u003e IP20 (Indoor use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1278\" data-end=\"1353\"\u003e\n\u003cp data-start=\"1280\" data-end=\"1353\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1298\"\u003eCompatibility:\u003c\/strong\u003e Fully integrates with INFI-Net network-based systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1355\" data-end=\"1373\"\u003e\u003cstrong data-start=\"1359\" data-end=\"1371\"\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1374\" data-end=\"2177\"\u003e\n\u003cli data-start=\"1374\" data-end=\"1516\"\u003e\n\u003cp data-start=\"1376\" data-end=\"1516\"\u003e\u003cstrong data-start=\"1376\" data-end=\"1406\"\u003eSeamless Data Integration:\u003c\/strong\u003e Transfers critical data between INFI-Net networks and computer systems, ensuring efficient data management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1517\" data-end=\"1658\"\u003e\n\u003cp data-start=\"1519\" data-end=\"1658\"\u003e\u003cstrong data-start=\"1519\" data-end=\"1546\"\u003eReliable Communication:\u003c\/strong\u003e Ensures stable data transmission over the INFI-Net, providing uninterrupted connectivity for process control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1659\" data-end=\"1787\"\u003e\n\u003cp data-start=\"1661\" data-end=\"1787\"\u003e\u003cstrong data-start=\"1661\" data-end=\"1686\"\u003eFlexible Integration:\u003c\/strong\u003e Easy integration with computer systems and compatible with various industrial automation software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1788\" data-end=\"1901\"\u003e\n\u003cp data-start=\"1790\" data-end=\"1901\"\u003e\u003cstrong data-start=\"1790\" data-end=\"1809\"\u003eDurable Design:\u003c\/strong\u003e Industrial-grade materials and construction for reliable operation in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1902\" data-end=\"2037\"\u003e\n\u003cp data-start=\"1904\" data-end=\"2037\"\u003e\u003cstrong data-start=\"1904\" data-end=\"1929\"\u003eReal-Time Monitoring:\u003c\/strong\u003e Supports real-time data monitoring and control for industrial processes, improving system responsiveness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2038\" data-end=\"2177\"\u003e\n\u003cp data-start=\"2040\" data-end=\"2177\"\u003e\u003cstrong data-start=\"2040\" data-end=\"2067\"\u003eEfficient Installation:\u003c\/strong\u003e Simple mounting options and easy-to-follow installation procedures reduce system downtime and simplify setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096843546933,"sku":"INCIT01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/INCIT01.png?v=1766712855"},{"product_id":"abb-iimlm01-multibus-loop-module-industrial-control-system","title":"ABB IIMLM01 Multibus Loop Module – Industrial Control System","description":"\u003ch3 data-start=\"193\" data-end=\"214\"\u003e\u003cstrong data-start=\"197\" data-end=\"212\"\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"215\" data-end=\"780\"\u003eThe ABB \u003cstrong data-start=\"219\" data-end=\"234\"\u003eIIMLM01\u003c\/strong\u003e Multibus Loop Module is a high-performance interface designed to facilitate communication between multiple industrial control systems and networks. This module is ideal for environments requiring precise control and real-time data exchange between devices. Offering reliable integration and support for multiple communication protocols, the IIMLM01 ensures smooth operation and data flow in demanding industrial automation applications. Its robust design guarantees long-term stability and high reliability for continuous system performance.\u003c\/p\u003e\n\u003ch3 data-start=\"782\" data-end=\"806\"\u003e\u003cstrong data-start=\"786\" data-end=\"804\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"807\" data-end=\"1490\"\u003e\n\u003cli data-start=\"807\" data-end=\"825\"\u003e\n\u003cp data-start=\"809\" data-end=\"825\"\u003e\u003cstrong data-start=\"809\" data-end=\"819\"\u003eBrand:\u003c\/strong\u003e ABB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"826\" data-end=\"852\"\u003e\n\u003cp data-start=\"828\" data-end=\"852\"\u003e\u003cstrong data-start=\"828\" data-end=\"838\"\u003eModel:\u003c\/strong\u003e IIMLM01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"853\" data-end=\"901\"\u003e\n\u003cp data-start=\"855\" data-end=\"901\"\u003e\u003cstrong data-start=\"855\" data-end=\"864\"\u003eType:\u003c\/strong\u003e Multibus loop communication module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"902\" data-end=\"988\"\u003e\n\u003cp data-start=\"904\" data-end=\"988\"\u003e\u003cstrong data-start=\"904\" data-end=\"922\"\u003eFunctionality:\u003c\/strong\u003e Facilitates communication between different industrial networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"989\" data-end=\"1100\"\u003e\n\u003cp data-start=\"991\" data-end=\"1100\"\u003e\u003cstrong data-start=\"991\" data-end=\"1012\"\u003eProtocol Support:\u003c\/strong\u003e Supports multiple communication protocols, ensuring flexibility in system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1101\" data-end=\"1180\"\u003e\n\u003cp data-start=\"1103\" data-end=\"1180\"\u003e\u003cstrong data-start=\"1103\" data-end=\"1120\"\u003eInput\/Output:\u003c\/strong\u003e Digital input\/output interface for seamless data exchange\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1181\" data-end=\"1217\"\u003e\n\u003cp data-start=\"1183\" data-end=\"1217\"\u003e\u003cstrong data-start=\"1183\" data-end=\"1200\"\u003ePower Supply:\u003c\/strong\u003e 24 VDC nominal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1218\" data-end=\"1263\"\u003e\n\u003cp data-start=\"1220\" data-end=\"1263\"\u003e\u003cstrong data-start=\"1220\" data-end=\"1246\"\u003eOperating Temperature:\u003c\/strong\u003e –10°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1264\" data-end=\"1301\"\u003e\n\u003cp data-start=\"1266\" data-end=\"1301\"\u003e\u003cstrong data-start=\"1266\" data-end=\"1281\"\u003eDimensions:\u003c\/strong\u003e 200 × 150 × 70 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1302\" data-end=\"1332\"\u003e\n\u003cp data-start=\"1304\" data-end=\"1332\"\u003e\u003cstrong data-start=\"1304\" data-end=\"1315\"\u003eWeight:\u003c\/strong\u003e Approx. 0.8 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1333\" data-end=\"1374\"\u003e\n\u003cp data-start=\"1335\" data-end=\"1374\"\u003e\u003cstrong data-start=\"1335\" data-end=\"1353\"\u003eMounting Type:\u003c\/strong\u003e DIN rail mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1375\" data-end=\"1418\"\u003e\n\u003cp data-start=\"1377\" data-end=\"1418\"\u003e\u003cstrong data-start=\"1377\" data-end=\"1398\"\u003eProtection Class:\u003c\/strong\u003e IP20 (Indoor use)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1419\" data-end=\"1490\"\u003e\n\u003cp data-start=\"1421\" data-end=\"1490\"\u003e\u003cstrong data-start=\"1421\" data-end=\"1439\"\u003eCompatibility:\u003c\/strong\u003e Works with various industrial automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1492\" data-end=\"1510\"\u003e\u003cstrong data-start=\"1496\" data-end=\"1508\"\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1511\" data-end=\"2206\"\u003e\n\u003cli data-start=\"1511\" data-end=\"1638\"\u003e\n\u003cp data-start=\"1513\" data-end=\"1638\"\u003e\u003cstrong data-start=\"1513\" data-end=\"1540\"\u003eMulti-Protocol Support:\u003c\/strong\u003e Compatible with a wide range of communication protocols, enabling versatile system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1639\" data-end=\"1755\"\u003e\n\u003cp data-start=\"1641\" data-end=\"1755\"\u003e\u003cstrong data-start=\"1641\" data-end=\"1668\"\u003eReliable Communication:\u003c\/strong\u003e Provides consistent, high-speed data transfer for industrial control and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1756\" data-end=\"1880\"\u003e\n\u003cp data-start=\"1758\" data-end=\"1880\"\u003e\u003cstrong data-start=\"1758\" data-end=\"1779\"\u003eEasy Integration:\u003c\/strong\u003e Modular design simplifies integration into existing control systems, minimizing installation time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1881\" data-end=\"1990\"\u003e\n\u003cp data-start=\"1883\" data-end=\"1990\"\u003e\u003cstrong data-start=\"1883\" data-end=\"1908\"\u003eDurable Construction:\u003c\/strong\u003e Built with high-quality materials to withstand demanding industrial conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1991\" data-end=\"2093\"\u003e\n\u003cp data-start=\"1993\" data-end=\"2093\"\u003e\u003cstrong data-start=\"1993\" data-end=\"2018\"\u003eEnhanced Flexibility:\u003c\/strong\u003e Supports multiple input\/output configurations for flexible system setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2094\" data-end=\"2206\"\u003e\n\u003cp data-start=\"2096\" data-end=\"2206\"\u003e\u003cstrong data-start=\"2096\" data-end=\"2116\"\u003eLow Maintenance:\u003c\/strong\u003e Designed for easy installation and maintenance, reducing downtime in operational systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096847675701,"sku":"IIMLM01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IIMLM01__1_8bf489e8-4015-4e28-95b0-db64b27c5b8e.jpg?v=1766713095"},{"product_id":"abb-iemmu01-bailey-infi-90-module-mounting-unit-mmu","title":"ABB IEMMU01 Bailey Infi 90 Module Mounting Unit (MMU)","description":"\u003ch3 data-path-to-node=\"1\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003eThe ABB IEMMU01 is a foundational 12-slot chassis engineered for the Bailey Infi 90 and Network 90 Distributed Control Systems (DCS). It serves as the mechanical and electrical framework, providing a high-integrity backplane that facilitates power distribution and bus communication for all connected process control and I\/O modules.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\"\u003eBrand:\u003c\/b\u003e ABB Bailey\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\"\u003eModel Number:\u003c\/b\u003e IEMMU01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\"\u003eSlot Capacity:\u003c\/b\u003e 12 module slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\"\u003eMounting Type:\u003c\/b\u003e Standard 19-inch rack mount\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\"\u003eProduct Net Weight:\u003c\/b\u003e 4.25 kg (9.37 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\"\u003eGross Weight:\u003c\/b\u003e 5.10 kg (11.24 lbs)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\"\u003eProduct Height:\u003c\/b\u003e 177.8 mm (7.0 inches \/ 4U)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\"\u003eProduct Width:\u003c\/b\u003e 482.6 mm (19.0 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\"\u003eProduct Depth:\u003c\/b\u003e 280.0 mm (11.0 inches)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,9,0\"\u003e\u003cb data-path-to-node=\"4,9,0\" data-index-in-node=\"0\"\u003eCommunication Interface:\u003c\/b\u003e Controlway and Slave Bus backplane integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\"\u003eHigh-Density Housing:\u003c\/b\u003e Accommodates up to 12 modules within a compact 4U rack space to maximize cabinet efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\"\u003eIntegrated Backplane:\u003c\/b\u003e Provides reliable signal routing and power distribution, reducing the need for external point-to-point wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\"\u003eRugged Construction:\u003c\/b\u003e Built with industrial-grade materials to ensure structural rigidity and protection against electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\"\u003eHot-Swap Support:\u003c\/b\u003e Enables efficient module replacement and system maintenance without disrupting the entire mounting unit infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eStandardized Compatibility:\u003c\/b\u003e Fully compatible with legacy Infi 90 cabinetry and various generations of ABB controller modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096850329909,"sku":"IEMMU01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IEMMU01.jpg?v=1766713424"},{"product_id":"abb-imamm03-master-module-analog","title":"ABB IMAMM03 Bailey Infi 90 Analog Master Module","description":"\u003ch3 data-path-to-node=\"1\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"\"\u003eThe ABB IMAMM03 is a high-performance Analog Master Module engineered for the Bailey Infi 90 distributed control system.\u003c\/span\u003e\u003cspan class=\"\"\u003e It functions as a primary interface for sophisticated analog signal processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e managing the data flow between field instruments and the central control architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module is essential for high-speed control loops and precision monitoring in complex industrial automation environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand:\u003c\/b\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number:\u003c\/b\u003e\u003cspan class=\"\"\u003e IMAMM03\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Type:\u003c\/b\u003e\u003cspan class=\"\"\u003e Analog Master Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSeries:\u003c\/b\u003e\u003cspan class=\"\"\u003e Infi 90 \/ Network 90\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Net Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e62 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e37 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\" class=\"\"\u003eGross Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e78 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e72 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Height:\u003c\/b\u003e\u003cspan class=\"\"\u003e 177.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 mm (7.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 inches)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Width:\u003c\/b\u003e\u003cspan class=\"\"\u003e 35.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 mm (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 inches)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Depth:\u003c\/b\u003e\u003cspan class=\"\"\u003e 298.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm (11.\u003c\/span\u003e\u003cspan class=\"\"\u003e75 inches)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,9,0\"\u003e\u003cb data-path-to-node=\"4,9,0\" data-index-in-node=\"0\" class=\"\"\u003eSystem Interface:\u003c\/b\u003e\u003cspan class=\"\"\u003e Compatible with MMU backplane via Controlway or Slave Bus\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\" class=\"\"\u003eAdvanced Data Acquisition:\u003c\/b\u003e\u003cspan class=\"\"\u003e High-speed processing of analog variables ensures real-time responsiveness for critical control applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\" class=\"\"\u003eMaster Logic Control:\u003c\/b\u003e\u003cspan class=\"\"\u003e Acts as a central coordination point for multiple slave I\/O units,\u003c\/span\u003e\u003cspan class=\"\"\u003e optimizing data throughput across the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\" class=\"\"\u003eRedundancy Support:\u003c\/b\u003e\u003cspan class=\"\"\u003e Designed to operate within redundant configurations to enhance system availability and prevent single points of failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\" class=\"\"\u003eOnboard Diagnostics:\u003c\/b\u003e\u003cspan class=\"\"\u003e Features integrated self-test capabilities that monitor module health and signal integrity,\u003c\/span\u003e\u003cspan\u003e reporting errors directly to the DCS.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\"\u003eIndustrial Reliability:\u003c\/b\u003e\u003cspan\u003e Built to withstand electromagnetic interference and thermal fluctuations typically found in power generation and chemical processing plants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096852853045,"sku":"IMAMM03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMAMM03__1.jpg?v=1766713644"},{"product_id":"abb-imasm02-analog-input-slave-module","title":"ABB IMASM02 Bailey Infi 90 Analog Input Slave Module","description":"\u003ch3 data-path-to-node=\"1\" class=\"\"\u003eDescription\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"\"\u003eThe ABB \u003cstrong\u003eIMASM02\u003c\/strong\u003e is a high-precision Analog Input Slave module designed for the Bailey Infi 90 and Network 90 distributed control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e This module functions as a critical bridge between field instruments and the master controller,\u003c\/span\u003e\u003cspan class=\"\"\u003e specialized in converting analog field signals into digital data for process monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e It is engineered to maintain high signal fidelity and reliable communication across the system's slave bus architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\" class=\"\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul data-path-to-node=\"4\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,0,0\"\u003e\u003cb data-path-to-node=\"4,0,0\" data-index-in-node=\"0\" class=\"\"\u003eBrand:\u003c\/b\u003e\u003cspan class=\"\"\u003e ABB Bailey\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,1,0\"\u003e\u003cb data-path-to-node=\"4,1,0\" data-index-in-node=\"0\" class=\"\"\u003eModel Number:\u003c\/b\u003e\u003cspan class=\"\"\u003e IMASM02\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,2,0\"\u003e\u003cb data-path-to-node=\"4,2,0\" data-index-in-node=\"0\" class=\"\"\u003eProduct Type:\u003c\/b\u003e\u003cspan class=\"\"\u003e Analog Input Slave Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,3,0\"\u003e\u003cb data-path-to-node=\"4,3,0\" data-index-in-node=\"0\" class=\"\"\u003eSeries:\u003c\/b\u003e\u003cspan class=\"\"\u003e Infi 90 \/ Network 90\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,4,0\"\u003e\u003cb data-path-to-node=\"4,4,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Channels:\u003c\/b\u003e\u003cspan class=\"\"\u003e 15 analog input channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,5,0\"\u003e\u003cb data-path-to-node=\"4,5,0\" data-index-in-node=\"0\" class=\"\"\u003eNet Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e54 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e19 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,6,0\"\u003e\u003cb data-path-to-node=\"4,6,0\" data-index-in-node=\"0\" class=\"\"\u003eGross Weight:\u003c\/b\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e68 kg (1.\u003c\/span\u003e\u003cspan class=\"\"\u003e50 lbs)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,7,0\"\u003e\u003cb data-path-to-node=\"4,7,0\" data-index-in-node=\"0\" class=\"\"\u003eDimensions (H x W x D):\u003c\/b\u003e\u003cspan class=\"\"\u003e 177.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 mm x 35.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 mm x 298.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,8,0\"\u003e\u003cb data-path-to-node=\"4,8,0\" data-index-in-node=\"0\" class=\"\"\u003eAnalog-to-Digital Resolution:\u003c\/b\u003e\u003cspan class=\"\"\u003e 12-bit or higher depending on configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"4,9,0\"\u003e\u003cb data-path-to-node=\"4,9,0\" data-index-in-node=\"0\" class=\"\"\u003eCommunication Interface:\u003c\/b\u003e\u003cspan class=\"\"\u003e Slave Bus (interconnects with IMAMM Master Modules)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"5\" class=\"\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-path-to-node=\"6\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,0,0\"\u003e\u003cb data-path-to-node=\"6,0,0\" data-index-in-node=\"0\" class=\"\"\u003eMulti-Channel Acquisition:\u003c\/b\u003e\u003cspan class=\"\"\u003e Provides simultaneous monitoring for up to 15 analog inputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e optimizing rack space efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,1,0\"\u003e\u003cb data-path-to-node=\"6,1,0\" data-index-in-node=\"0\" class=\"\"\u003eSignal Versatility:\u003c\/b\u003e\u003cspan class=\"\"\u003e Capable of processing a variety of signal ranges,\u003c\/span\u003e\u003cspan class=\"\"\u003e typically including 1-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e 0-5 VDC,\u003c\/span\u003e\u003cspan class=\"\"\u003e and 0-10 VDC inputs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,2,0\"\u003e\u003cb data-path-to-node=\"6,2,0\" data-index-in-node=\"0\" class=\"\"\u003eSlave Bus Integration:\u003c\/b\u003e\u003cspan class=\"\"\u003e Seamlessly communicates with Master Modules via the mounting unit backplane for centralized data processing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,3,0\"\u003e\u003cb data-path-to-node=\"6,3,0\" data-index-in-node=\"0\" class=\"\"\u003eRobust Isolation:\u003c\/b\u003e\u003cspan class=\"\"\u003e Features built-in protection to prevent field-side electrical surges from damaging the sensitive control system backplane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"6,4,0\"\u003e\u003cb data-path-to-node=\"6,4,0\" data-index-in-node=\"0\" class=\"\"\u003eDiagnostic Reporting:\u003c\/b\u003e\u003cspan class=\"\"\u003e Includes local LED indicators and system-level error detection to streamline maintenance and troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52096853868853,"sku":"IMASM02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IMASM02__1.jpg?v=1766713867"}],"url":"https:\/\/www.5gplc.com\/collections\/abb-bailey-infi-90-net-90.oembed?page=7\u0026type=grid","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}